1.Integrated Optical and Magnetic Navigation for Simplified Percutaneous Transforaminal Endoscopic Lumbar Discectomy: A Novel Approach
Xing-Chen YAO ; Jun-Peng LIU ; Xin-Ru DU ; Li GUAN ; Yong HAI ; Jincai YANG ; Aixing PAN
Neurospine 2025;22(1):297-307
Objective:
This study aims to evaluate the clinical benefits of the integrated optical and magnetic surgical navigation system in assisting transforaminal endoscopic lumbar discectomy (TELD) for the treatment of lumbar disc herniation (LDH).
Methods:
A retrospective analysis was conducted on patients who underwent TELD for LDH at Beijing Chaoyang Hospital, Capital Medical University from November 2022 to December 2023. Patients treated with the integrated optical and magnetic surgical navigation system were defined as the navigation-guided TELD (Ng-TELD) group (30 cases), while those treated with the conventional x-ray fluoroscopy method were defined as the control group (31 cases). Record and compare baseline characteristics, surgical parameters, efficacy indicators, and adverse events between the 2 patient groups.
Results:
The average follow-up duration for the 61 patients was 11.8 months. Postoperatively, both groups exhibited significant relief from back and leg pain, which continued to improve over time. At the final follow-up, patients’ lumbar function and quality of life had significantly improved compared to preoperative levels (p < 0.05). The Ng-TELD group had significantly shorter total operation time (58.43 ± 12.37 minutes vs. 83.23 ± 25.90 minutes), catheter placement time (5.83 ± 1.09 minutes vs. 15.94 ± 3.00 minutes), decompression time (47.17 ± 11.98 minutes vs. 67.29 ± 24.23 minutes), and fewer intraoperative fluoroscopies (3.20 ± 1.45 vs. 16.58 ± 4.25) compared to the control group (p < 0.05). There were no significant differences between the groups in terms of efficacy evaluation indicators and hospital stay. At the final follow-up, the excellent and good rate of surgical outcomes assessed by the MacNab criteria was 98.4%, and the overall adverse event rate was 8.2%, with no statistically significant differences between the groups (p > 0.05).
Conclusion
This study demonstrates that the integrated optical and magnetic surgical navigation system can reduce the complexity of TELD, shorten operation time, and minimize radiation exposure for the surgeon, highlighting its promising clinical potential.
2.Integrated Optical and Magnetic Navigation for Simplified Percutaneous Transforaminal Endoscopic Lumbar Discectomy: A Novel Approach
Xing-Chen YAO ; Jun-Peng LIU ; Xin-Ru DU ; Li GUAN ; Yong HAI ; Jincai YANG ; Aixing PAN
Neurospine 2025;22(1):297-307
Objective:
This study aims to evaluate the clinical benefits of the integrated optical and magnetic surgical navigation system in assisting transforaminal endoscopic lumbar discectomy (TELD) for the treatment of lumbar disc herniation (LDH).
Methods:
A retrospective analysis was conducted on patients who underwent TELD for LDH at Beijing Chaoyang Hospital, Capital Medical University from November 2022 to December 2023. Patients treated with the integrated optical and magnetic surgical navigation system were defined as the navigation-guided TELD (Ng-TELD) group (30 cases), while those treated with the conventional x-ray fluoroscopy method were defined as the control group (31 cases). Record and compare baseline characteristics, surgical parameters, efficacy indicators, and adverse events between the 2 patient groups.
Results:
The average follow-up duration for the 61 patients was 11.8 months. Postoperatively, both groups exhibited significant relief from back and leg pain, which continued to improve over time. At the final follow-up, patients’ lumbar function and quality of life had significantly improved compared to preoperative levels (p < 0.05). The Ng-TELD group had significantly shorter total operation time (58.43 ± 12.37 minutes vs. 83.23 ± 25.90 minutes), catheter placement time (5.83 ± 1.09 minutes vs. 15.94 ± 3.00 minutes), decompression time (47.17 ± 11.98 minutes vs. 67.29 ± 24.23 minutes), and fewer intraoperative fluoroscopies (3.20 ± 1.45 vs. 16.58 ± 4.25) compared to the control group (p < 0.05). There were no significant differences between the groups in terms of efficacy evaluation indicators and hospital stay. At the final follow-up, the excellent and good rate of surgical outcomes assessed by the MacNab criteria was 98.4%, and the overall adverse event rate was 8.2%, with no statistically significant differences between the groups (p > 0.05).
Conclusion
This study demonstrates that the integrated optical and magnetic surgical navigation system can reduce the complexity of TELD, shorten operation time, and minimize radiation exposure for the surgeon, highlighting its promising clinical potential.
3.Integrated Optical and Magnetic Navigation for Simplified Percutaneous Transforaminal Endoscopic Lumbar Discectomy: A Novel Approach
Xing-Chen YAO ; Jun-Peng LIU ; Xin-Ru DU ; Li GUAN ; Yong HAI ; Jincai YANG ; Aixing PAN
Neurospine 2025;22(1):297-307
Objective:
This study aims to evaluate the clinical benefits of the integrated optical and magnetic surgical navigation system in assisting transforaminal endoscopic lumbar discectomy (TELD) for the treatment of lumbar disc herniation (LDH).
Methods:
A retrospective analysis was conducted on patients who underwent TELD for LDH at Beijing Chaoyang Hospital, Capital Medical University from November 2022 to December 2023. Patients treated with the integrated optical and magnetic surgical navigation system were defined as the navigation-guided TELD (Ng-TELD) group (30 cases), while those treated with the conventional x-ray fluoroscopy method were defined as the control group (31 cases). Record and compare baseline characteristics, surgical parameters, efficacy indicators, and adverse events between the 2 patient groups.
Results:
The average follow-up duration for the 61 patients was 11.8 months. Postoperatively, both groups exhibited significant relief from back and leg pain, which continued to improve over time. At the final follow-up, patients’ lumbar function and quality of life had significantly improved compared to preoperative levels (p < 0.05). The Ng-TELD group had significantly shorter total operation time (58.43 ± 12.37 minutes vs. 83.23 ± 25.90 minutes), catheter placement time (5.83 ± 1.09 minutes vs. 15.94 ± 3.00 minutes), decompression time (47.17 ± 11.98 minutes vs. 67.29 ± 24.23 minutes), and fewer intraoperative fluoroscopies (3.20 ± 1.45 vs. 16.58 ± 4.25) compared to the control group (p < 0.05). There were no significant differences between the groups in terms of efficacy evaluation indicators and hospital stay. At the final follow-up, the excellent and good rate of surgical outcomes assessed by the MacNab criteria was 98.4%, and the overall adverse event rate was 8.2%, with no statistically significant differences between the groups (p > 0.05).
Conclusion
This study demonstrates that the integrated optical and magnetic surgical navigation system can reduce the complexity of TELD, shorten operation time, and minimize radiation exposure for the surgeon, highlighting its promising clinical potential.
4.Integrated Optical and Magnetic Navigation for Simplified Percutaneous Transforaminal Endoscopic Lumbar Discectomy: A Novel Approach
Xing-Chen YAO ; Jun-Peng LIU ; Xin-Ru DU ; Li GUAN ; Yong HAI ; Jincai YANG ; Aixing PAN
Neurospine 2025;22(1):297-307
Objective:
This study aims to evaluate the clinical benefits of the integrated optical and magnetic surgical navigation system in assisting transforaminal endoscopic lumbar discectomy (TELD) for the treatment of lumbar disc herniation (LDH).
Methods:
A retrospective analysis was conducted on patients who underwent TELD for LDH at Beijing Chaoyang Hospital, Capital Medical University from November 2022 to December 2023. Patients treated with the integrated optical and magnetic surgical navigation system were defined as the navigation-guided TELD (Ng-TELD) group (30 cases), while those treated with the conventional x-ray fluoroscopy method were defined as the control group (31 cases). Record and compare baseline characteristics, surgical parameters, efficacy indicators, and adverse events between the 2 patient groups.
Results:
The average follow-up duration for the 61 patients was 11.8 months. Postoperatively, both groups exhibited significant relief from back and leg pain, which continued to improve over time. At the final follow-up, patients’ lumbar function and quality of life had significantly improved compared to preoperative levels (p < 0.05). The Ng-TELD group had significantly shorter total operation time (58.43 ± 12.37 minutes vs. 83.23 ± 25.90 minutes), catheter placement time (5.83 ± 1.09 minutes vs. 15.94 ± 3.00 minutes), decompression time (47.17 ± 11.98 minutes vs. 67.29 ± 24.23 minutes), and fewer intraoperative fluoroscopies (3.20 ± 1.45 vs. 16.58 ± 4.25) compared to the control group (p < 0.05). There were no significant differences between the groups in terms of efficacy evaluation indicators and hospital stay. At the final follow-up, the excellent and good rate of surgical outcomes assessed by the MacNab criteria was 98.4%, and the overall adverse event rate was 8.2%, with no statistically significant differences between the groups (p > 0.05).
Conclusion
This study demonstrates that the integrated optical and magnetic surgical navigation system can reduce the complexity of TELD, shorten operation time, and minimize radiation exposure for the surgeon, highlighting its promising clinical potential.
5.Integrated Optical and Magnetic Navigation for Simplified Percutaneous Transforaminal Endoscopic Lumbar Discectomy: A Novel Approach
Xing-Chen YAO ; Jun-Peng LIU ; Xin-Ru DU ; Li GUAN ; Yong HAI ; Jincai YANG ; Aixing PAN
Neurospine 2025;22(1):297-307
Objective:
This study aims to evaluate the clinical benefits of the integrated optical and magnetic surgical navigation system in assisting transforaminal endoscopic lumbar discectomy (TELD) for the treatment of lumbar disc herniation (LDH).
Methods:
A retrospective analysis was conducted on patients who underwent TELD for LDH at Beijing Chaoyang Hospital, Capital Medical University from November 2022 to December 2023. Patients treated with the integrated optical and magnetic surgical navigation system were defined as the navigation-guided TELD (Ng-TELD) group (30 cases), while those treated with the conventional x-ray fluoroscopy method were defined as the control group (31 cases). Record and compare baseline characteristics, surgical parameters, efficacy indicators, and adverse events between the 2 patient groups.
Results:
The average follow-up duration for the 61 patients was 11.8 months. Postoperatively, both groups exhibited significant relief from back and leg pain, which continued to improve over time. At the final follow-up, patients’ lumbar function and quality of life had significantly improved compared to preoperative levels (p < 0.05). The Ng-TELD group had significantly shorter total operation time (58.43 ± 12.37 minutes vs. 83.23 ± 25.90 minutes), catheter placement time (5.83 ± 1.09 minutes vs. 15.94 ± 3.00 minutes), decompression time (47.17 ± 11.98 minutes vs. 67.29 ± 24.23 minutes), and fewer intraoperative fluoroscopies (3.20 ± 1.45 vs. 16.58 ± 4.25) compared to the control group (p < 0.05). There were no significant differences between the groups in terms of efficacy evaluation indicators and hospital stay. At the final follow-up, the excellent and good rate of surgical outcomes assessed by the MacNab criteria was 98.4%, and the overall adverse event rate was 8.2%, with no statistically significant differences between the groups (p > 0.05).
Conclusion
This study demonstrates that the integrated optical and magnetic surgical navigation system can reduce the complexity of TELD, shorten operation time, and minimize radiation exposure for the surgeon, highlighting its promising clinical potential.
6.Electroacupuncture at Sensitized Acupoints Relieves Somatic Referred Pain in Colitis Rats by Inhibiting Sympathetic-Sensory Coupling to Interfere with 5-HT Signaling Pathway.
Ying YANG ; Jin-Yu QU ; Hua GUO ; Hai-Ying ZHOU ; Xia RUAN ; Ying-Chun PENG ; Xue-Fang SHEN ; Jin XIONG ; Yi-Li WANG
Chinese journal of integrative medicine 2024;30(2):152-162
OBJECTIVE:
To investigate whether electroacupuncture (EA) at sensitized acupoints could reduce sympathetic-sensory coupling (SSC) and neurogenic inflammatory response by interfering with 5-hydroxytryptamine (5-HT)ergic neural pathways to relieve colitis and somatic referred pain, and explore the underlying mechanisms.
METHODS:
Rats were treated with 5% dextran sodium sulfate (DSS) solution for 7 days to establish a colitis model. Twelve rats were randomly divided into the control and model groups according to a random number table (n=6). According to the "Research on Rat Acupoint Atlas", sensitized acupoints and non-sensitized acupoints were determined. Rats were randomly divided into the control, model, Zusanli-EA (ST 36), Dachangshu-EA (BL 25), and Xinshu (BL 15) groups (n=6), as well as the control, model, EA, and EA + GR113808 (a 5-HT inhibitor) groups (n=6). The rats in the control group received no treatment. Acupuncture was administered on 2 days after modeling using the stimulation pavameters: 1 mA, 2 Hz, for 30 min, with sparse and dense waves, for 14 consecutive days. GR113808 was injected into the tail vein at 5 mg/kg before EA for 10 min for 7 consecutive days. Mechanical sensitivity was assessed with von Frey filaments. Body weight and disease activity index (DAI) scores of rats were determined. Hematoxylin and eosin staining was performed to observe colon histopathology. SSC was analyzed by immunofluorescence staining. Immunohistochemical staining was performed to detect 5-HT and substance P (SP) expressions. The calcitonin gene-related peptide (CGRP) in skin tissue and tyrosine hydroxylase (TH) protein levels in DRG were detected by Western blot. The levels of hyaluronic acid (HA), bradykinin (BK), prostaglandin I2 (PGI2) in skin tissue, 5-HT, tryptophan hydroxylase 1 (TPH1), serotonin transporters (SERT), 5-HT 3 receptor (5-HT3R), and 5-HT 4 receptor (5-HT4R) in colon tissue were measured by enzyme-linked immunosorbent assay (ELISA).
RESULTS:
BL 25 and ST 36 acupoints were determined as sensitized acupoints, and BL 15 acupoint was used as a non-sensitized acupoint. EA at sensitized acupoints improved the DAI score, increased mechanical withdrawal thresholds, and alleviated colonic pathological damage of rats. EA at sensitized acupoints reduced SSC structures and decreased TH and CGRP expression levels (P<0.05). Furthermore, EA at sensitized acupoints reduced BK, PGI2, 5-HT, 5-HT3R and TPH1 levels, and increased HA, 5-HT4R and SERT levels in colitis rats (P<0.05). GR113808 treatment diminished the protective effect of EA at sensitized acupoints in colitis rats (P<0.05).
CONCLUSION
EA at sensitized acupoints alleviated DSS-induced somatic referred pain in colitis rats by interfering with 5-HTergic neural pathway, and reducing SSC inflammatory response.
Rats
;
Animals
;
Electroacupuncture
;
Rats, Sprague-Dawley
;
Serotonin
;
Acupuncture Points
;
Pain, Referred
;
Calcitonin Gene-Related Peptide
;
Signal Transduction
;
Colitis/therapy*
;
Indoles
;
Sulfonamides
7.Construction and characterization of lpxC deletion strain based on CRISPR/Cas9 in Acinetobacter baumannii
Zong-ti SUN ; You-wen ZHANG ; Hai-bin LI ; Xiu-kun WANG ; Jie YU ; Jin-ru XIE ; Peng-bo PANG ; Xin-xin HU ; Tong-ying NIE ; Xi LU ; Jing PANG ; Lei HOU ; Xin-yi YANG ; Cong-ran LI ; Lang SUN ; Xue-fu YOU
Acta Pharmaceutica Sinica 2024;59(5):1286-1294
Lipopolysaccharides (LPS) are major outer membrane components of Gram-negative bacteria. Unlike most Gram-negative bacteria,
8.Biomechanical characteristics of thoracic T10 bone tumor metastasis at different locations:three-dimensional finite element analysis
Guoren XIA ; Hao YU ; Shifeng JIANG ; Xin PENG ; Xiao FU ; Qi CHEN ; Lizhuang YANG ; Tengfei WANG ; Hai LI
Chinese Journal of Tissue Engineering Research 2024;28(36):5759-5765
BACKGROUND:With the innovation of examination technique,the number of patients with spinal metastases in different stages is increasing year by year.Percutaneous vertebroplasty is an important treatment for spinal metastases;however,there is no report on the biomechanical effect in different stages and different activities after operation. OBJECTIVE:To simulate thoracic T10 bone stress and displacement of the different locations of the tumor metastasis based on the three-dimensional finite element model. METHODS:According to thoracic three-dimensional CT images of a 30-year-old healthy male,Mimics software was used to construct a three-dimensional geometric model of thoracic vertebrae(T9-T11),including ribs,ligaments and intervertebral discs.Three-dimensional models of T9-T11 vertebral bodies and different parts of the posterior thoracic vertebrae invaded by thoracic metastatic tumors were simulated,including the control group with intact vertebral structure,unilateral metastasis involving the vertebral body area(experimental group 1),unilateral metastasis involving the vertebral body and pedicle area(experimental group 2),unilateral metastasis involving the vertebral body,pedicle and transverse process area(experimental group 3),and bilateral metastasis involving the vertebral body,pedicle and transverse process area(experimental group 4).Abaqus software was used to create a three-dimensional finite element model.The von Mises stress distribution and the displacement of the model were analyzed under the loading condition,buckling condition,extension condition,and rotation condition. RESULTS AND CONCLUSION:(1)In the study of the maximum total displacement of loading points in different experimental groups under loading,flexion,extension,and rotation conditions,with the increase of metastatic tumor invasion site and invasion surface,the total displacement of loading points increased,and the overall stiffness decreased,especially the total displacement of loading points in experimental group 4 was the largest.(2)Under flexion condition,the maximum Von Mises stress value increased significantly after vertebral body and pedicle destruction,while the maximum Von Mises stress value was almost unchanged when the thoracocostal joint destruction was added.(3)On the basis of finite element analysis and simulation of bone tumor model,the elements in the bone cement region were set as a single set,and the bone cement region was set as the corresponding material properties to simulate bone cement filling.The results showed that the maximum total displacement under loading,flexion,extension,and rotation conditions was less than that of each experimental group.(4)The maximum stress values of the simulated percutaneous vertebroplasty patients in the loading,flexion,extension and rotation conditions were significantly lower than those of the femoral model.(5)It is concluded that the three-dimensional finite element model based on thoracic T9-T11 conducive to the biomechanics characteristics of thoracic vertebrae tumor metastasis,and on the basis of the thoracic vertebrae tumor metastasis model can accurately simulate load point after percutaneous vertebral body under different conditions of total displacement and the maximum Von Mises stress situation.
9.Bioequivalence study of olmesartan medoxomil tablet in Chinese healthy subjects
Na SHAN ; Da-Hai JIANG ; Lin-Lin MIAO ; Zhen-Li REN ; Peng-Bo JIN ; Pei-Qi HAO ; Li AN ; Hong ZHU ; Yong XIN ; Guang-De YANG ; Feng LIU
The Chinese Journal of Clinical Pharmacology 2024;40(20):3033-3037
Objective To study the bioequivalence of test and reference olmesartan tablet in Chinese healthy subjects after single dose under fasting and fed conditions.Methods A single-center,random,open,single-dose,two-preparations,double-period,crossover study was adopted.A total of 48 healthy adult male and female subjects(24 cases of fasting test and 24 cases of fed test)were included in the random crossover administration.Single oral dose 20 mg of test and reference were taken under fasting and postprandial conditions,respectively.Plasma concentration of olmesartan in plasma were determined by liquid chromatography tandem mass spectrometry.The main pharmacokinetic parameters were calculated by Phoenix WinNonlin 8.0 software.Results The main pharmacokinetic parameters of the test and reference preparations of olmesartan tablets in the fasting group were as follows:Cmax were(653.06±133.53)and(617.37±151.16)ng·mL-1,AUC0-t were(4 201.18±1 035.21)and(4 087.38±889.99)ng·mL-1·h,AUC0-∞ were(4 254.30±1 058.90)and(4 135.69±905.29)ng·mL-1·h.The main pharmacokinetic parameters of the test and reference preparations of olmesartan tablets in the postprandial group were as follows:Cmax were(574.78±177.05)and(579.98±107.74)ng·mL-1,AUC0-t were(3 288.37±866.06)and(3 181.51±801.06)ng·mL-1·h,AUC0-∞ were(3 326.11±874.26)and(3 242.01±823.09)ng·mL-1·h.Under fasting and postprandial conditions,the 90%confidence intervals of the main pharmacokinetic parameters of the test and reference preparations are both 80.00%-125.00%.Conclusion Under fasting and postprandial conditions,a single oral dose of test and reference preparations olmesartan tablets in Chinese healthy adult volunteers showed bioequivalence.
10.Development of biological safety protection third-level laboratory based on folding-modular shelters
Si-Qing ZHAO ; Jian-Qiao XIA ; Zhong-Jie SUN ; Kang OUYANG ; Xiao-Jun JIN ; Kang-Li ZHOU ; Wei XIE ; Hai-Yang LI ; Da-Peng JIANG ; Yan-Yan GAO ; Bei SUN
Chinese Medical Equipment Journal 2024;45(3):41-46
Objective To develop a biological safety protection third-level(BSL-3)laboratory based on folding-modular shelters to solve the problems of the existing laboratories in space and function expansion,large-scale deployment and low-cost transportation.Methods The BSL-3 laboratory was composed of a folding combined shelter module,a ventilation and purification module,a power supply and distribution module,a monitoring and communication module,a control system module and an equipment module.The folding combined shelter module used a leveling base frame as the foundation and a lightweight panel as the enclosure mechanism,and was divided into an auxiliary area and a protection protected area;the ventilation and purification module was made up of an air supply unit and an air exhaust unit,the air supply unit was integrated with a fresh-air air conditioner and the exhaust unit was equipped with a main fan,a standby fan and a bag in/bag out filter;the control system module adopted a supervision mode of decentralized control and centralized management,which executed communication with the data server as the center and Profinet protocol and MODBUS-TCP.Results The BSL-3 laboratory proved to meet the requirements of relevant standards in internal microenvironment,airflow direction,airtightness,working condition and disinfection effect.Conclusion The BSL-3 laboratory is compatible with large-scale transport and deployment and facilitates reliable and safe experiments for epidemic prevention and control and cross-regional support.[Chinese Medical Equipment Journal,2024,45(3):41-46]

Result Analysis
Print
Save
E-mail