1.Applications of Optical Technology in Non-invasive Hemoglobin Detection
Yao PENG ; Xian-Long WANG ; Bi-Tie LAN ; Jian-Hai YU
Progress in Biochemistry and Biophysics 2026;53(6):1561-1580
Hemoglobin (Hb) concentration is a key clinical biomarker for diagnosing and managing anemia, ischemic stroke, perioperative blood loss, and chronic diseases such as renal failure. Traditional venous blood sampling remains the gold standard due to its high accuracy, but its invasive nature limits frequent testing, real time monitoring, and large scale screening. This has driven growing interest in non-invasive Hb detection technologies over the past decade. Among these, optical methods are the most promising because of their safety, potential for continuous monitoring, and compatibility with portable or wearable devices. This paper systematically reviews major advances in optical non invasive Hb detection from the last ten years. We focus on near-infrared spectroscopy branches—photoplethysmography (PPG) and dynamic spectrum (DS)—and also cover color analysis/RGB imaging, Raman spectroscopy, and photoacoustic spectroscopy. For each technology, we explain its detection principles, analyze advantages and limitations, and summarize optimization strategies reported in recent literature. PPG, based on pulsatile blood volume changes, underpins many commercial continuous monitors. However, its accuracy is constrained by motion artifacts, individual physiological variations (e.g., skin tone, tissue thickness), and low AC signal to noise ratio. In contrast, DS—an advanced derivative of PPG—uses a differential principle to extract absorbance changes between systolic and diastolic peaks. This theoretically eliminates interference from static tissues (skin, bone, venous blood) and common mode noise (e.g., ambient light), positioning DS as a more robust framework for high precision Hb quantification. Beyond spectral methods, color analysis/RGB imaging offers a hardware minimalist approach. By analyzing images of vascular rich, thin tissues (e.g., conjunctiva, nail beds, palms), it enables Hb estimation using smartphone cameras. Recent advances have shifted from manual RGB feature extraction to deep learning models and spectral super resolution that reconstruct hyperspectral data from RGB inputs, significantly improving screening accuracy. Our academic perspective emphasizes critical and integrative analysis. We highlight persistent challenges that hinder clinical translation: profound individual biological variability (skin optics, microvascular architecture), sensitivity to measurement conditions (pressure, ambient light), and a lack of standardized validation protocols and multi center trials. A central thesis is that no single optical method is universally superior; each involves trade offs between accuracy, complexity, cost, and practicality. Looking forward, we posit that the next performance leap will come from multimodal information fusion—combining PPG, electrocardiogram (ECG), bioimpedance, or different optical modalities to compensate for individual differences and environmental noise. AI and deep learning are essential not only for image analysis but also for automated, end to end feature extraction from complex waveforms like PPG sequences. Advancing hardware (tunable lasers, quantum dot LEDs, novel sensor designs) is crucial to improve signal fidelity and portability. Finally, we advocate for clinical scenario specific optimization and rigorous standardized evaluation frameworks to gain regulatory approval (e.g., FDA, NMPA) and achieve widespread clinical acceptance. In conclusion, this review synthesizes a decade of progress. Optical non-invasive Hb detection has evolved from proof of concept studies to emerging products and validated screening tools, but the journey toward reliable, clinic ready quantitative devices continues. The convergence of smarter algorithms, fused sensing modalities, and focused clinical validation offers the most promising path to transform this potential into routine medical practice, ultimately enabling personalized, continuous, and accessible hematological management.
2.Technical features and latest advances in robot-assisted radical cystectomy with orthotopic neobladder reconstruction
Journal of Modern Urology 2026;31(3):201-206
Robot-assisted radical cystectomy(RARC)combined with orthotopic neobladder(ONB)reconstruction represents a key function-preserving surgical approach for the treatment of muscle-invasive bladder cancer(MIBC). This review systematically summarizes current techniques and standardized operative procedures for ONB reconstruction, including the modified Studer, Bordeaux, and conventional Y-shaped methods, with a focus on the innovative totally intracorporeal modified Y-shaped orthotopic neobladder technique developed by our department. Based on perioperative data of 5 bladder cancer patients treated during Jan. and Dec. 2024, the comprehensive impacts of this technique on functional outcomes, oncological efficacy and patients' quality of life were evaluated. The review aims to provide evidence-based support for the standardized adoption of this technique and a three-dimensional anatomical teaching paradigm.
3.Clinical efficacy of open reduction and internal fixation with plates versus minimally invasive Kirschner wire fixation for osteoporotic Colles' fractures.
Jun-Wei ZHANG ; Jin-Yong HOU ; Zhao-Hui LI ; Zhen-Yuan MA ; Xiang GAO ; Hong-Zheng BI ; Ling-Ling CHEN ; Hai-Tao WANG ; Wei-Zhi NIE ; Yong-Zhong CHENG ; Xiao-Bing XI
China Journal of Orthopaedics and Traumatology 2025;38(1):18-24
OBJECTIVE:
To compare the short-term clinical efficacy and safety of closed reduction with Kirschner wire fixation versus open reduction with plate fixation for treating osteoporotic Colles' fractures in middle-aged and elderly patients.
METHODS:
Between January 2018 and January 2023, 119 patients with Colles fractures were retrospectively analyzed, including 39 males and 80 females, aged from 48 to 74 years old with an average of(60.58±6.71) years old. The time from injury to operation ranged 1 to 13 days with an average of (5.29±2.52) days. According to the surgical method, they were divided into Kirschner wire fixation group (Kirschner wire group) and plate internal fixation group (plate group). In Kirschner wire group, there were a total of 68 patients, comprising 21 males and 47 females. The average age was (61.15±6.24) years old, ranged from 49 to 74 years old. Among them, 41 cases involved the left side while 27 cases involved the right side. In the plate group, there were a total of 51 patients, including 18 males and 33 females. The average age was (59.78±5.71) years old ranged from 48 to 72 years old. Among them, there were 31 cases on the left side and 20 cases on the right side. The following parameters were recorded before and after the operation:operation time, intraoperative blood loss, hospitalization days, hospitalization expenses, postoperative complications, and radiographic parameters of distal radius (distal radius height, ulnar deviation angle, palmar tilt angle). The clinical efficacy was evaluated at 3 and 12 months after the operation using Gartland-Werley and disabilites of the arm shoulder and hand (DASH) scores.
RESULTS:
The patients in both groups were followed up for a duration from 12 to 19 months with an average of(13.32±2.02) months. The Kirschner wire group exhibited significantly shorter operation time compared to the plate group 27.91(13.00, 42.00) min vs 67.52(29.72, 105.32) min, Z=-8.74, P=0.00. Intraoperative blood loss was also significantly lower in the Kirschner wire group than in the plate group 3.24(1.08, 5.40) ml vs 21.91(17.38, 26.44) ml, Z=-9.31, P=0.00. Furthermore, patients in the Kirschner wire group had a shorter length of hospital stay compared to those in the plate group (8.38±2.63) days vs (11.40±2.78) days, t=-3.12, P=0.00. Additionally, hospitalization cost was significantly lower in the Kirschner wire group than in the plate group 10 111.29(6 738.98, 13 483.60) yuan vs 15 871.11(11 690.40, 20 051.82) yuan, Z=-5.62, P=0.00. The incidence of complications was 2 cases in the Kirschner wire group and 1 case in the plate group, with no statistically significant difference(P>0.05). At 3 months postoprative, the radial height of the Kirschner wire group was found to be significantly smaller than that of the plate group, with measurements of (11.45±1.69) mm and (12.11±1.78) mm respectively (t=-2.06, P=0.04). However, there were no statistically significant differences observed in ulnar deviation angle and palmar tilt angle between the two groups (P>0.05). The DASH score and Gartland-Werley score in the Kirschner group were significantly higher than those in the plate group at 3 months post-operation (19.10±9.89) vs (13.47±3.51), t=4.34, P=0.00;(11.15±3.61) vs (6.41±2.75), t=8.13, P=0.00). However, there was no significant difference between the two groups at 12 months post-operation (P>0.05).
CONCLUSION
Compared to plate internal fixation, closed reduction with Kirschner wire support fixation yields a slightly inferior recovery of radial height;however, there is no significant disparity in the functional score of the affected limb at 12 months post-operation. Nonetheless, this technique offers advantages such as shorter operation time, reduced intraoperative blood loss, decreased hospitalization duration, and lower cost.
Humans
;
Female
;
Male
;
Middle Aged
;
Aged
;
Fracture Fixation, Internal/instrumentation*
;
Bone Wires
;
Bone Plates
;
Retrospective Studies
;
Colles' Fracture/surgery*
;
Minimally Invasive Surgical Procedures/methods*
;
Open Fracture Reduction/methods*
;
Osteoporotic Fractures/surgery*
4.Multi-modal magnetic resonance imaging assessment and mechanism exploration of preterm white matter injury in neonatal rats.
Xiao-Tian GAO ; Hai-Mo ZHANG ; Xiao-Zu ZHANG ; Yi-Jing WANG ; Hui-Ning BI ; Miao YU ; Yan LI ; Xiao-Li WANG
Chinese Journal of Contemporary Pediatrics 2025;27(3):366-372
OBJECTIVES:
To evaluate preterm white matter injury (PWMI) in neonatal rats using multimodal magnetic resonance imaging (MRI) combined with histological assessments and to explore its underlying mechanisms.
METHODS:
Healthy 3-day-old Sprague-Dawley neonatal rats were randomly divided into a sham operation group and a PWMI group (n=12 in each group). A PWMI model was established in neonatal rats through hypoxia-ischemia. Laser speckle imaging was used to observe changes in cerebral oxygen saturation and blood flow at different time points post-modeling. Multimodal MRI was employed to assess the condition of white matter injury, while hematoxylin-eosin staining was utilized to observe morphological changes in the striatal area on the injured side. Immunofluorescence staining was performed to detect the proliferation and differentiation of oligodendrocyte precursor cells.
RESULTS:
At 0, 6, 12, 24, and 72 hours post-modeling, the relative blood flow and relative oxygen saturation on the injured side in the PWMI group were significantly lower than those in the sham operation group (P<0.05). At 24 hours post-modeling, T2-weighted imaging showed high signals in the white matter of the injured side in the PWMI group, with relative apparent diffusion coefficient values and Lorenz differential values being lower than those in the sham operation group (P<0.001); additionally, the arrangement of nerve cells in the PWMI group was disordered, and the number of EdU+PDGFR-α+ cells was higher than that in the sham operation group (P<0.001). At 28 days post-modeling, the relative fractional anisotropy values, the number of EdU+Olig2+ cells, and the fluorescence intensity of myelin basic protein and neurofilament protein 200 in the white matter region of the PWMI group were all lower than those in the sham operation group (P<0.001).
CONCLUSIONS
Multimodal MRI can evaluate early and long-term changes in PWMI in neonatal rat models in vivo, providing both imaging and pathological evidence for the diagnosis and treatment of PWMI in neonates. Hypoxia-ischemia inhibits the proliferation and differentiation of oligodendrocyte precursor cells in neonatal rats, leading to PWMI.
Animals
;
Rats, Sprague-Dawley
;
Magnetic Resonance Imaging/methods*
;
Rats
;
White Matter/injuries*
;
Animals, Newborn
;
Female
;
Multimodal Imaging
;
Male
;
Hypoxia-Ischemia, Brain/pathology*
5.Differences in mercury dissolution from HgS-containing traditional medicines under simulated gastrointestinal conditions
Ming ZHANG ; Yuan-can XIAO ; Jing ZHAO ; Hai-ying TONG ; Xiao-yu WANG ; Wen-bin ZHOU ; Hong-tao BI ; Li-xin WEI
Chinese Traditional Patent Medicine 2025;47(8):2607-2611
AIM To investigate the variations in mercury dissolution from HgS-containing traditional medicines in three kinds of simulated gastrointestinal dissolution media.METHODS 39 batches of 15 types of HgS-containing traditional medicines were collected,total mercury content and dissolved mercury concentrations in simulated gastric fluid,simulated intestinal fluid,and L-cysteine-containing simulated intestinal fluid were measured.The maximum daily intake of total mercury and soluble mercury was calculated based on the maximum daily clinical dosage.RESULTS Among the 15 types of medicines,the maximum daily intake of total mercury varied by 156 times,the daily intake of soluble mercury varied by 3 502 times in simulated gastric fluid,313 times in simulated intestinal fluid,and 10 663 times in L-cysteine-containing simulated intestinal fluid,approximately.CONCLUSION For the 15 types of HgS-containing traditional medicines,the daily maximum intake of soluble mercury showed greater variations than that of total mercury.Soluble mercury concentration is more closely correlated with intestinal absorption of mercury and thus represents a more rational quality control indicator for HgS-containing traditional medicines.
6.Efficacy of transfer learning artificial intelligence model based on ultrasound in evaluating the probability of malignancy of partially cystic thyroid nodule
Ying ZOU ; Jihua LIU ; Jingyi LI ; Hai BI ; Yan SHI ; Xiudi LU ; Qibo ZHANG
The Journal of Practical Medicine 2025;41(6):889-895
Objective To investigate the feasibility and accuracy of an ultrasound-based transfer learning artificial intelligence model in predicting the malignancy probability of partially cystic thyroid nodules(PCTN).Methods A retrospective analysis was conducted on 246 patients with PCTN who had definitive pathological results and were admitted to Weihai Municipal Hospital,Cheeloo College of Medicine,Shandong University from January 2021 to December 2023.Patients were randomly divided into training and test cohorts at a ratio of 7:3.Ultrasonic image features of PCTN were evaluated,and independent risk factors were identified using multivariate logistic regression analysis,with the area under the curve(AUC)subsequently calculated.Additionally,five different pre-trained models-Inception_v3,EfficientNet,VGG19,ResNet50,and DenseNet121-were selected for transfer learning after data preprocessing using the PyTorch framework in Python.The AUC values of these models were calculated and compared.Results Solid portion greater than 50%,eccentric acute angle,ill-defined margin,spiculated or microlobulated margin,rim calcification,and microcalcification exhibited statistically significant differences(P<0.05)in distinguishing between benign and malignant PCTN.The AUC value derived from these independent risk factors was 0.843.Furthermore,among the five transfer learning models evaluated,the ResNet50 model demonstrated the highest diagnostic efficiency,achieving an AUC value of 0.903 2.Conclusion The ultrasound-based transfer learning artificial intelligence model demonstrated superior performance compared to traditional ultrasound image evaluation methods,enabling accurate prediction of the nature of PCTN and thereby reducing unnecessary ultrasound-guided fine needle biopsies.
7.Efficacy of transfer learning artificial intelligence model based on ultrasound in evaluating the probability of malignancy of partially cystic thyroid nodule
Ying ZOU ; Jihua LIU ; Jingyi LI ; Hai BI ; Yan SHI ; Xiudi LU ; Qibo ZHANG
The Journal of Practical Medicine 2025;41(6):889-895
Objective To investigate the feasibility and accuracy of an ultrasound-based transfer learning artificial intelligence model in predicting the malignancy probability of partially cystic thyroid nodules(PCTN).Methods A retrospective analysis was conducted on 246 patients with PCTN who had definitive pathological results and were admitted to Weihai Municipal Hospital,Cheeloo College of Medicine,Shandong University from January 2021 to December 2023.Patients were randomly divided into training and test cohorts at a ratio of 7:3.Ultrasonic image features of PCTN were evaluated,and independent risk factors were identified using multivariate logistic regression analysis,with the area under the curve(AUC)subsequently calculated.Additionally,five different pre-trained models-Inception_v3,EfficientNet,VGG19,ResNet50,and DenseNet121-were selected for transfer learning after data preprocessing using the PyTorch framework in Python.The AUC values of these models were calculated and compared.Results Solid portion greater than 50%,eccentric acute angle,ill-defined margin,spiculated or microlobulated margin,rim calcification,and microcalcification exhibited statistically significant differences(P<0.05)in distinguishing between benign and malignant PCTN.The AUC value derived from these independent risk factors was 0.843.Furthermore,among the five transfer learning models evaluated,the ResNet50 model demonstrated the highest diagnostic efficiency,achieving an AUC value of 0.903 2.Conclusion The ultrasound-based transfer learning artificial intelligence model demonstrated superior performance compared to traditional ultrasound image evaluation methods,enabling accurate prediction of the nature of PCTN and thereby reducing unnecessary ultrasound-guided fine needle biopsies.
8.Differences in mercury dissolution from HgS-containing traditional medicines under simulated gastrointestinal conditions
Ming ZHANG ; Yuan-can XIAO ; Jing ZHAO ; Hai-ying TONG ; Xiao-yu WANG ; Wen-bin ZHOU ; Hong-tao BI ; Li-xin WEI
Chinese Traditional Patent Medicine 2025;47(8):2607-2611
AIM To investigate the variations in mercury dissolution from HgS-containing traditional medicines in three kinds of simulated gastrointestinal dissolution media.METHODS 39 batches of 15 types of HgS-containing traditional medicines were collected,total mercury content and dissolved mercury concentrations in simulated gastric fluid,simulated intestinal fluid,and L-cysteine-containing simulated intestinal fluid were measured.The maximum daily intake of total mercury and soluble mercury was calculated based on the maximum daily clinical dosage.RESULTS Among the 15 types of medicines,the maximum daily intake of total mercury varied by 156 times,the daily intake of soluble mercury varied by 3 502 times in simulated gastric fluid,313 times in simulated intestinal fluid,and 10 663 times in L-cysteine-containing simulated intestinal fluid,approximately.CONCLUSION For the 15 types of HgS-containing traditional medicines,the daily maximum intake of soluble mercury showed greater variations than that of total mercury.Soluble mercury concentration is more closely correlated with intestinal absorption of mercury and thus represents a more rational quality control indicator for HgS-containing traditional medicines.
9.Exploration of Thoughts and Possible Therapeutic Mechanism of Treating Male Infertility from the Perspective of Spleen and Kidney by Regulating Intestinal Flora
Nian-Wen HUANG ; Bin WANG ; Ji-Sheng WANG ; Huan-Zhou BI ; Juan-Long FENG ; Long-Ji SUN ; Hai-Song LI
Journal of Guangzhou University of Traditional Chinese Medicine 2024;41(3):776-781
Based on the literature study,the thoughts and possible therapeutic mechanism in treating male infertility from the perspective of spleen and kidney by regulating intestinal flora were explored.Disturbance of intestinal flora is one of the important factors leading to the development of male infertility,and the spleen and kidney have certain similarities to intestinal flora in the physiological function and pathological changes.Moreover,tonifying the kidney and strengthening the spleen can regulate the intestinal flora by fostering the growth of beneficial bacteria,inhibiting the reproduction of pathogenic bacteria,and protecting the barrier of the intestinal mucosa.Therefore,the possible therapeutic mechanisms in treating male infertility with the prescriptions for tonifying the kidney and strengthening the spleen to regulate intestinal flora are as follows:inhibiting the expression of inflammatory factors to reduce the inflammatory reaction of testicular tissues;improving the antioxidant capacity to alleviate the damage of spermatozoa caused by oxidative stress,and improving the bad mood to alleviate the impact of psychological stress on the reproductive system.The exploration of the thoughts for treating male infertility from the perspective of spleen and kidney by regulating intestinal flora may provide a new entry point for modern Chinese medicine clinical treatment of male infertility.
10.ZnO Quantum Dot and SnO2 Quantum Dot Labeling Antibodies and Single Particle Inductively Coupled Plasma Mass Spectrometry Coupled with Magnetic Immunoassay for Detection of Ovarian Cancer Biomarkers CA125 and HE4 in Human Serum
Yu-Pin CAO ; Hai-Ping CHEN ; Jie LIANG ; Bi-Yang DENG
Chinese Journal of Analytical Chemistry 2024;52(10):1562-1572
Ovarian cancer is one of the most fatal of all the gynecological malignancies.The detection of biomarker is one of the diagnostic bases for the disease.The combined detection of carbohydrate antigen 125(CA125)and human epididymis protein 4(HE4)in human serum can improve the accuracy of clinical diagnosis for ovarian cancer.In this study,a new method for analysis of ovarian cancer biomarkers CA125 and HE4 in human serum using zinc oxide quantum dot(ZnO QD)and tin oxide quantum dot(SnO2 QD)labeled antibodies coupled with single particle inductively coupled plasma mass spectrometry(ICP-MS)was developed.CA125 and HE4 antigens were captured by amino-modified magnetic nanoparticles combined with CA125 and HE4 primary antibodies.CA125 and HE4 secondary antibodies were labeled by ZnO QD and SnO2 QD,respectively.The signal frequency of Zn and Sn was determined by ICP-MS to realize the quantitative analysis of CA125 and HE4.The linear detection ranges of CA125 and HE4 were 0.02-200 U/mL and 0.02-100 ng/mL,the detection limits were 0.004 U/mL and 0.006 ng/mL(3σ),and the RSDs were 2.2%and 3.5%(n=6),respectively.This method had many advantages such as high sensitivity,good selectivity and less reagent consumption,and was successfully applied to determine the content of CA125 and HE4 in human serum.

Result Analysis
Print
Save
E-mail