1.Ultrafast MRI for Pediatric Brain Assessment in Routine Clinical Practice
Hee Eun MOON ; Ji Young HA ; Jae Won CHOI ; Seung Hyun LEE ; Jae-Yeon HWANG ; Young Hun CHOI ; Jung-Eun CHEON ; Yeon Jin CHO
Korean Journal of Radiology 2025;26(1):75-87
Objective:
To assess the feasibility of ultrafast brain magnetic resonance imaging (MRI) in pediatric patients.
Materials and Methods:
We retrospectively reviewed 194 pediatric patients aged 0 to 19 years (median 10.2 years) who underwent both ultrafast and conventional brain MRI between May 2019 and August 2020. Ultrafast MRI sequences included T1 and T2-weighted images (T1WI and T2WI), fluid-attenuated inversion recovery (FLAIR), T2*-weighted image (T2*WI), and diffusion-weighted image (DWI). Qualitative image quality and lesion evaluations were conducted on 5-point Likert scales by two blinded radiologists, with quantitative assessment of lesion count and size on T1WI, T2WI, and FLAIR sequences for each protocol. Wilcoxon signed-rank tests and intraclass correlation coefficient (ICC) analyses were used for comparison.
Results:
The total scan times for equivalent image contrasts were 1 minute 44 seconds for ultrafast MRI and 15 minutes 30 seconds for conventional MRI. Overall, image quality was lower in ultrafast MRI than in conventional MRI, with mean quality scores ranging from 2.0 to 4.8 for ultrafast MRI and 4.8 to 5.0 for conventional MRI across sequences (P < 0.001 for T1WI, T2WI, FLAIR, and T2*WI for both readers; P = 0.018 [reader 1] and 0.031 [reader 2] for DWI). Lesion detection rates on ultrafast MRI relative to conventional MRI were as follows: T1WI, 97.1%; T2WI, 99.6%; FLAIR, 92.9%; T2*WI, 74.1%; and DWI, 100%. The ICC (95% confidence interval) for lesion size measurements between ultrafast and conventional MRI was as follows: T1WI, 0.998 (0.996–0.999); T2WI, 0.998 (0.997–0.999); and FLAIR, 0.99 (0.985–0.994).
Conclusion
Ultrafast MRI significantly reduces scan time and provides acceptable results, albeit with slightly lower image quality than conventional MRI, for evaluating intracranial abnormalities in pediatric patients.
2.Occupational disease monitoring by the Korea Occupational Disease Surveillance Center: a narrative review
Dong-Wook LEE ; Inah KIM ; Jungho HWANG ; Sunhaeng CHOI ; Tae-Won JANG ; Insung CHUNG ; Hwan-Cheol KIM ; Jaebum PARK ; Jungwon KIM ; Kyoung Sook JEONG ; Youngki KIM ; Eun-Soo LEE ; Yangwoo KIM ; Inchul JEONG ; Hyunjeong OH ; Hyeoncheol OH ; Jea Chul HA ; Jeehee MIN ; Chul Gab LEE ; Heon KIM ; Jaechul SONG
The Ewha Medical Journal 2025;48(1):e9-
This review examines the challenges associated with occupational disease surveillance in Korea, particularly emphasizing the limitations of current data sources such as the Industrial Accident Compensation Insurance (IACI) statistics and special health examinations. The IACI system undercounts cases due to its emphasis on severe diseases and restrictions on approvals. Special health examinations, although they cover a broad workforce, are constrained by their annual scheduling, which leads to missed acute illnesses and subclinical conditions. The paper also explores the history of occupational disease surveillance in Korea, highlighting the fragmented and disease-specific approach of earlier systems. The authors introduce the newly established Korea Occupational Disease Surveillance Center (KODSC), a comprehensive nationwide system designed to gather, analyze, and interpret data on occupational diseases through a network of regional centers. By incorporating hospital-based surveillance and focusing on acute poisonings and other sentinel events, the KODSC aims to overcome the limitations of previous systems and promote collaboration with various agencies. Although it is still in the early stages of implementation, the KODSC demonstrates potential for improving data accuracy and contributing valuable insights for public health policy.
3.Ultrafast MRI for Pediatric Brain Assessment in Routine Clinical Practice
Hee Eun MOON ; Ji Young HA ; Jae Won CHOI ; Seung Hyun LEE ; Jae-Yeon HWANG ; Young Hun CHOI ; Jung-Eun CHEON ; Yeon Jin CHO
Korean Journal of Radiology 2025;26(1):75-87
Objective:
To assess the feasibility of ultrafast brain magnetic resonance imaging (MRI) in pediatric patients.
Materials and Methods:
We retrospectively reviewed 194 pediatric patients aged 0 to 19 years (median 10.2 years) who underwent both ultrafast and conventional brain MRI between May 2019 and August 2020. Ultrafast MRI sequences included T1 and T2-weighted images (T1WI and T2WI), fluid-attenuated inversion recovery (FLAIR), T2*-weighted image (T2*WI), and diffusion-weighted image (DWI). Qualitative image quality and lesion evaluations were conducted on 5-point Likert scales by two blinded radiologists, with quantitative assessment of lesion count and size on T1WI, T2WI, and FLAIR sequences for each protocol. Wilcoxon signed-rank tests and intraclass correlation coefficient (ICC) analyses were used for comparison.
Results:
The total scan times for equivalent image contrasts were 1 minute 44 seconds for ultrafast MRI and 15 minutes 30 seconds for conventional MRI. Overall, image quality was lower in ultrafast MRI than in conventional MRI, with mean quality scores ranging from 2.0 to 4.8 for ultrafast MRI and 4.8 to 5.0 for conventional MRI across sequences (P < 0.001 for T1WI, T2WI, FLAIR, and T2*WI for both readers; P = 0.018 [reader 1] and 0.031 [reader 2] for DWI). Lesion detection rates on ultrafast MRI relative to conventional MRI were as follows: T1WI, 97.1%; T2WI, 99.6%; FLAIR, 92.9%; T2*WI, 74.1%; and DWI, 100%. The ICC (95% confidence interval) for lesion size measurements between ultrafast and conventional MRI was as follows: T1WI, 0.998 (0.996–0.999); T2WI, 0.998 (0.997–0.999); and FLAIR, 0.99 (0.985–0.994).
Conclusion
Ultrafast MRI significantly reduces scan time and provides acceptable results, albeit with slightly lower image quality than conventional MRI, for evaluating intracranial abnormalities in pediatric patients.
4.Occupational disease monitoring by the Korea Occupational Disease Surveillance Center: a narrative review
Dong-Wook LEE ; Inah KIM ; Jungho HWANG ; Sunhaeng CHOI ; Tae-Won JANG ; Insung CHUNG ; Hwan-Cheol KIM ; Jaebum PARK ; Jungwon KIM ; Kyoung Sook JEONG ; Youngki KIM ; Eun-Soo LEE ; Yangwoo KIM ; Inchul JEONG ; Hyunjeong OH ; Hyeoncheol OH ; Jea Chul HA ; Jeehee MIN ; Chul Gab LEE ; Heon KIM ; Jaechul SONG
The Ewha Medical Journal 2025;48(1):e9-
This review examines the challenges associated with occupational disease surveillance in Korea, particularly emphasizing the limitations of current data sources such as the Industrial Accident Compensation Insurance (IACI) statistics and special health examinations. The IACI system undercounts cases due to its emphasis on severe diseases and restrictions on approvals. Special health examinations, although they cover a broad workforce, are constrained by their annual scheduling, which leads to missed acute illnesses and subclinical conditions. The paper also explores the history of occupational disease surveillance in Korea, highlighting the fragmented and disease-specific approach of earlier systems. The authors introduce the newly established Korea Occupational Disease Surveillance Center (KODSC), a comprehensive nationwide system designed to gather, analyze, and interpret data on occupational diseases through a network of regional centers. By incorporating hospital-based surveillance and focusing on acute poisonings and other sentinel events, the KODSC aims to overcome the limitations of previous systems and promote collaboration with various agencies. Although it is still in the early stages of implementation, the KODSC demonstrates potential for improving data accuracy and contributing valuable insights for public health policy.
5.Ultrafast MRI for Pediatric Brain Assessment in Routine Clinical Practice
Hee Eun MOON ; Ji Young HA ; Jae Won CHOI ; Seung Hyun LEE ; Jae-Yeon HWANG ; Young Hun CHOI ; Jung-Eun CHEON ; Yeon Jin CHO
Korean Journal of Radiology 2025;26(1):75-87
Objective:
To assess the feasibility of ultrafast brain magnetic resonance imaging (MRI) in pediatric patients.
Materials and Methods:
We retrospectively reviewed 194 pediatric patients aged 0 to 19 years (median 10.2 years) who underwent both ultrafast and conventional brain MRI between May 2019 and August 2020. Ultrafast MRI sequences included T1 and T2-weighted images (T1WI and T2WI), fluid-attenuated inversion recovery (FLAIR), T2*-weighted image (T2*WI), and diffusion-weighted image (DWI). Qualitative image quality and lesion evaluations were conducted on 5-point Likert scales by two blinded radiologists, with quantitative assessment of lesion count and size on T1WI, T2WI, and FLAIR sequences for each protocol. Wilcoxon signed-rank tests and intraclass correlation coefficient (ICC) analyses were used for comparison.
Results:
The total scan times for equivalent image contrasts were 1 minute 44 seconds for ultrafast MRI and 15 minutes 30 seconds for conventional MRI. Overall, image quality was lower in ultrafast MRI than in conventional MRI, with mean quality scores ranging from 2.0 to 4.8 for ultrafast MRI and 4.8 to 5.0 for conventional MRI across sequences (P < 0.001 for T1WI, T2WI, FLAIR, and T2*WI for both readers; P = 0.018 [reader 1] and 0.031 [reader 2] for DWI). Lesion detection rates on ultrafast MRI relative to conventional MRI were as follows: T1WI, 97.1%; T2WI, 99.6%; FLAIR, 92.9%; T2*WI, 74.1%; and DWI, 100%. The ICC (95% confidence interval) for lesion size measurements between ultrafast and conventional MRI was as follows: T1WI, 0.998 (0.996–0.999); T2WI, 0.998 (0.997–0.999); and FLAIR, 0.99 (0.985–0.994).
Conclusion
Ultrafast MRI significantly reduces scan time and provides acceptable results, albeit with slightly lower image quality than conventional MRI, for evaluating intracranial abnormalities in pediatric patients.
6.Occupational disease monitoring by the Korea Occupational Disease Surveillance Center: a narrative review
Dong-Wook LEE ; Inah KIM ; Jungho HWANG ; Sunhaeng CHOI ; Tae-Won JANG ; Insung CHUNG ; Hwan-Cheol KIM ; Jaebum PARK ; Jungwon KIM ; Kyoung Sook JEONG ; Youngki KIM ; Eun-Soo LEE ; Yangwoo KIM ; Inchul JEONG ; Hyunjeong OH ; Hyeoncheol OH ; Jea Chul HA ; Jeehee MIN ; Chul Gab LEE ; Heon KIM ; Jaechul SONG
The Ewha Medical Journal 2025;48(1):e9-
This review examines the challenges associated with occupational disease surveillance in Korea, particularly emphasizing the limitations of current data sources such as the Industrial Accident Compensation Insurance (IACI) statistics and special health examinations. The IACI system undercounts cases due to its emphasis on severe diseases and restrictions on approvals. Special health examinations, although they cover a broad workforce, are constrained by their annual scheduling, which leads to missed acute illnesses and subclinical conditions. The paper also explores the history of occupational disease surveillance in Korea, highlighting the fragmented and disease-specific approach of earlier systems. The authors introduce the newly established Korea Occupational Disease Surveillance Center (KODSC), a comprehensive nationwide system designed to gather, analyze, and interpret data on occupational diseases through a network of regional centers. By incorporating hospital-based surveillance and focusing on acute poisonings and other sentinel events, the KODSC aims to overcome the limitations of previous systems and promote collaboration with various agencies. Although it is still in the early stages of implementation, the KODSC demonstrates potential for improving data accuracy and contributing valuable insights for public health policy.
7.A Comparison between Keratograph 5M® and IDRA® in Dry Eye Patients
Seo Woo PARK ; Ha-Rim SO ; Ji Won BAEK ; Ho Sik HWANG ; Kyung-Sun NA ; Ho RA ; Nam Yeo KANG ; Hyun Seung KIM ; Eun Chul KIM
Journal of the Korean Ophthalmological Society 2025;66(4):175-180
Purpose:
To evaluate the compatibility and usability of test results obtained from the IDRA and Keratograph 5M in clinical settings by comparing their performance in patients with dry eye disease.
Methods:
From December 27 to 30, 2022, a study was conducted on 30 patients diagnosed with dry eye utilizing both the Keratograph 5M and IDRA devices. The parameters compared and analyzed included lipid layer thickness, tear meniscus height, tear film break-up time, and meibography. A paired t-test was used for statistical comparison. The lipid layer thickness in the Keratograph 5M was graded on a scale from 0 to 4 based on thickness.
Results:
No significant differences were found between the two devices in tear film break-up time, tear meniscus height, and meibography (p = 0.148, 0.072, 0.124, respectively). However, the tear lipid layer thickness measured by IDRA showed a proportional relationship with the grade assigned by the Keratograph 5M (Kendall R = 0.217, p = 0.037; Spearman R = 0.260, p = 0.045).
Conclusions
The IDRA device offers the advantage of performing multiple dry eye tests; simultaneously, thereby saving time compared to the Keratograph 5M. Both devices can be used compatibly with IDRA particularly advantageous for providing a numerical value for tear lipid layer thickness which enhances the convenience of dry eye diagnosis and treatment.
8.Risk-adapted scoring model to identify candidates benefiting from adjuvant chemotherapy after radical nephroureterectomy for localized upper urinary tract urothelial carcinoma: A multicenter study
Sung Jun SOU ; Ja Yoon KU ; Kyung Hwan KIM ; Won Ik SEO ; Hong Koo HA ; Hui Mo GU ; Eu Chang HWANG ; Young Joo PARK ; Chan Ho LEE
Investigative and Clinical Urology 2025;66(2):114-123
Purpose:
Adjuvant chemotherapy (AC) is recommended for muscle-invasive or lymph node-positive upper urinary tract urothelial carcinoma (UTUC) after radical nephroureterectomy (RNU). However, disease recurrences are frequently observed in pT1 disease, and AC may increase the risk of overtreatment in pT2 UTUC patients. This study aimed to validate a risk-adapted scoring model for selecting UTUC patients with ≤pT2 disease who would benefit from AC.
Materials and Methods:
We retrospectively analyzed 443 ≤pT2 UTUC patients who underwent RNU. A risk-adapted scoring model was applied, categorizing patients into low- or high-risk groups. Recurrence-free survival (RFS) and cancer-specific survival (CSS) were analyzed according to risk group.
Results:
Overall, 355 patients (80.1%) and 88 patients (19.9%) were categorized into the low- and high-risk groups, respectively, with the latter having higher pathological stages, concurrent carcinoma in situ, and synchronous bladder tumors. Disease recurrence occurred in 45 patients (10.2%), among whom 19 (5.4%) and 26 (29.5%) belonged to the low- and high-risk groups, respectively (p<0.001). High-risk patients had significantly shorter RFS (64.3% vs. 93.6% at 60 months; hazard ratio [HR] 13.66; p<0.001) and worse CSS (80.7% vs. 91.5% at 60 months; HR 4.25; p=0.002). Multivariate analysis confirmed that pT2 stage and the high-risk group were independent predictors of recurrence and cancer-specific death (p<0.001). Decision curve analysis for RFS showed larger net benefits with our model than with the T stage model.
Conclusions
The risk-adapted scoring model effectively predicts recurrence and identifies optimal candidates for AC post RNU in non-metastatic UTUC.
9.A Comparison between Keratograph 5M® and IDRA® in Dry Eye Patients
Seo Woo PARK ; Ha-Rim SO ; Ji Won BAEK ; Ho Sik HWANG ; Kyung-Sun NA ; Ho RA ; Nam Yeo KANG ; Hyun Seung KIM ; Eun Chul KIM
Journal of the Korean Ophthalmological Society 2025;66(4):175-180
Purpose:
To evaluate the compatibility and usability of test results obtained from the IDRA and Keratograph 5M in clinical settings by comparing their performance in patients with dry eye disease.
Methods:
From December 27 to 30, 2022, a study was conducted on 30 patients diagnosed with dry eye utilizing both the Keratograph 5M and IDRA devices. The parameters compared and analyzed included lipid layer thickness, tear meniscus height, tear film break-up time, and meibography. A paired t-test was used for statistical comparison. The lipid layer thickness in the Keratograph 5M was graded on a scale from 0 to 4 based on thickness.
Results:
No significant differences were found between the two devices in tear film break-up time, tear meniscus height, and meibography (p = 0.148, 0.072, 0.124, respectively). However, the tear lipid layer thickness measured by IDRA showed a proportional relationship with the grade assigned by the Keratograph 5M (Kendall R = 0.217, p = 0.037; Spearman R = 0.260, p = 0.045).
Conclusions
The IDRA device offers the advantage of performing multiple dry eye tests; simultaneously, thereby saving time compared to the Keratograph 5M. Both devices can be used compatibly with IDRA particularly advantageous for providing a numerical value for tear lipid layer thickness which enhances the convenience of dry eye diagnosis and treatment.
10.Ultrafast MRI for Pediatric Brain Assessment in Routine Clinical Practice
Hee Eun MOON ; Ji Young HA ; Jae Won CHOI ; Seung Hyun LEE ; Jae-Yeon HWANG ; Young Hun CHOI ; Jung-Eun CHEON ; Yeon Jin CHO
Korean Journal of Radiology 2025;26(1):75-87
Objective:
To assess the feasibility of ultrafast brain magnetic resonance imaging (MRI) in pediatric patients.
Materials and Methods:
We retrospectively reviewed 194 pediatric patients aged 0 to 19 years (median 10.2 years) who underwent both ultrafast and conventional brain MRI between May 2019 and August 2020. Ultrafast MRI sequences included T1 and T2-weighted images (T1WI and T2WI), fluid-attenuated inversion recovery (FLAIR), T2*-weighted image (T2*WI), and diffusion-weighted image (DWI). Qualitative image quality and lesion evaluations were conducted on 5-point Likert scales by two blinded radiologists, with quantitative assessment of lesion count and size on T1WI, T2WI, and FLAIR sequences for each protocol. Wilcoxon signed-rank tests and intraclass correlation coefficient (ICC) analyses were used for comparison.
Results:
The total scan times for equivalent image contrasts were 1 minute 44 seconds for ultrafast MRI and 15 minutes 30 seconds for conventional MRI. Overall, image quality was lower in ultrafast MRI than in conventional MRI, with mean quality scores ranging from 2.0 to 4.8 for ultrafast MRI and 4.8 to 5.0 for conventional MRI across sequences (P < 0.001 for T1WI, T2WI, FLAIR, and T2*WI for both readers; P = 0.018 [reader 1] and 0.031 [reader 2] for DWI). Lesion detection rates on ultrafast MRI relative to conventional MRI were as follows: T1WI, 97.1%; T2WI, 99.6%; FLAIR, 92.9%; T2*WI, 74.1%; and DWI, 100%. The ICC (95% confidence interval) for lesion size measurements between ultrafast and conventional MRI was as follows: T1WI, 0.998 (0.996–0.999); T2WI, 0.998 (0.997–0.999); and FLAIR, 0.99 (0.985–0.994).
Conclusion
Ultrafast MRI significantly reduces scan time and provides acceptable results, albeit with slightly lower image quality than conventional MRI, for evaluating intracranial abnormalities in pediatric patients.

Result Analysis
Print
Save
E-mail