1.Anterior Segment Swept-Source Optical Coherence Tomography–based Assessment of Corneal Refractive Profiles in Stevens-Johnson Syndrome/Toxic Epidermal Necrolysis Patients: A Controlled Comparative Study
Dong Hee HA ; Seung Hyeun LEE ; Kyoung Woo KIM
Korean Journal of Ophthalmology 2025;39(2):103-113
Purpose:
To analyze anterior, posterior, and total corneal refractive profiles and thickness using anterior segment (AS) sweptsource optical coherence tomography (SS-OCT) in Stevens-Johnson syndrome (SJS) or toxic epidermal necrolysis (TEN) patients.
Methods:
This retrospective study compared 23 eyes from 14 patients with SJS/TEN with 23 eyes from 14 age- and sexmatched controls. AS SS-OCT measured corneal refractive profiles and pachymetry. Parameters included anterior, posterior, and total corneal power values, posterior to anterior curvature ratio, maximal corneal power, and thickness profiles. The SJS/TEN group was subdivided based on corneal opacity presence (subgroup A) or absence (subgroup B).
Results:
The SJS/TEN group showed significantly higher corneal astigmatism and maximal corneal power values for both anterior and posterior curvatures. Steep total corneal power and total corneal astigmatism were higher in the SJS/TEN group. The thinnest corneal thickness was lower, and its distance from the corneal vertex was greater in the SJS/TEN group. Subgroup analysis revealed that these differences were primarily attributed to the presence of corneal opacity. Additionally, automated keratometry of the anterior corneal surface showed significantly higher values, including steep, flat, and average keratometry and corneal astigmatism, in the SJS/TEN group.
Conclusions
AS SS-OCT shows significant alterations in both anterior and posterior corneal curvatures in patients with SJS/TEN. These findings emphasize the importance of considering posterior corneal curvature changes in pre-cataract surgery assessments and contact lens prescriptions for patients with SJS/TEN.
2.Effect of 50-Hz Filters on Pattern Electroretinogram
Dong Hee HA ; Nam Ju MOON ; Ungsoo Samuel KIM
Korean Journal of Ophthalmology 2025;39(3):241-245
Purpose:
Pattern electroretinogram (PERG) is used to evaluate the function of retinal ganglion cells. However, the amplitude of PERG is quite small, making the examination challenging to perform. Waveform noise may be minimized by applying various filters. We aimed to investigate the effect of 50-Hz filters on PERG test results.
Methods:
This is the retrospective observational study. PERG tests were performed using the RETI-scan system according to the International Society for Clinical Electrophysiology of Vision guidelines. Three types of 50-Hz filters (soft, middle, and hard) were applied. The differences in parameters (N35 peak time, P50 peak time, N95 peak time, P50 amplitude, N95 amplitude, and N95 to P50 ratio) were analyzed. Based on the provided normal range, the changes from normal to abnormal range or vice versa were investigated.
Results:
A total of 24 waveforms were analyzed. After filtering, the P50 and N95 amplitudes showed a significant reduction of 8% to 15% (P50 amplitude: 5.1 ± 2.7 μV without filter, 4.6 ± 2.3 μV with 50-Hz soft filter, 4.3 ± 2.1 μV with 50-Hz middle filter, 4.3 ± 2.1 μV with 50-Hz hard filter; N95 amplitude: 7.2 ± 4.2 μV without filter, 6.6 ± 3.8 μV with 50-Hz soft filter, 6.3 ± 3.6 μV with 50-Hz middle filter, 6.1 ± 3.6 μV with 50-Hz hard filter). This pattern was more prominent in normal subjects. All latencies except the N35 peak time exhibited no differences between the tests. The N95 to P50 ratio decreased after 50-Hz middle and hard filtering. Considering the normative data, switching between normal and abnormal results was rare.
Conclusions
Although peak time was not significantly affected, amplitude was significantly reduced after using 50-Hz filters. Thus, 50-Hz filters can smoothen the waveform. Nevertheless, caution must be exercised while taking readings.
3.Radiofrequency Ablation for Recurrent Thyroid Cancers:2025 Korean Society of Thyroid Radiology Guideline
Eun Ju HA ; Min Kyoung LEE ; Jung Hwan BAEK ; Hyun Kyung LIM ; Hye Shin AHN ; Seon Mi BAEK ; Yoon Jung CHOI ; Sae Rom CHUNG ; Ji-hoon KIM ; Jae Ho SHIN ; Ji Ye LEE ; Min Ji HONG ; Hyun Jin KIM ; Leehi JOO ; Soo Yeon HAHN ; So Lyung JUNG ; Chang Yoon LEE ; Jeong Hyun LEE ; Young Hen LEE ; Jeong Seon PARK ; Jung Hee SHIN ; Jin Yong SUNG ; Miyoung CHOI ; Dong Gyu NA ;
Korean Journal of Radiology 2025;26(1):10-28
Radiofrequency ablation (RFA) is a minimally invasive treatment modality used as an alternative to surgery in patients with benign thyroid nodules, recurrent thyroid cancers (RTCs), and primary thyroid microcarcinomas. The Korean Society of Thyroid Radiology (KSThR) initially developed recommendations for the optimal use of RFA for thyroid tumors in 2009 and revised them in 2012 and 2017. As new meaningful evidence has accumulated since 2017 and in response to a growing global interest in the use of RFA for treating malignant thyroid lesions, the task force committee members of the KSThR decided to update the guidelines on the use of RFA for the management of RTCs based on a comprehensive analysis of current literature and expert consensus.
4.Occupational disease monitoring by the Korea Occupational Disease Surveillance Center: a narrative review
Dong-Wook LEE ; Inah KIM ; Jungho HWANG ; Sunhaeng CHOI ; Tae-Won JANG ; Insung CHUNG ; Hwan-Cheol KIM ; Jaebum PARK ; Jungwon KIM ; Kyoung Sook JEONG ; Youngki KIM ; Eun-Soo LEE ; Yangwoo KIM ; Inchul JEONG ; Hyunjeong OH ; Hyeoncheol OH ; Jea Chul HA ; Jeehee MIN ; Chul Gab LEE ; Heon KIM ; Jaechul SONG
The Ewha Medical Journal 2025;48(1):e9-
This review examines the challenges associated with occupational disease surveillance in Korea, particularly emphasizing the limitations of current data sources such as the Industrial Accident Compensation Insurance (IACI) statistics and special health examinations. The IACI system undercounts cases due to its emphasis on severe diseases and restrictions on approvals. Special health examinations, although they cover a broad workforce, are constrained by their annual scheduling, which leads to missed acute illnesses and subclinical conditions. The paper also explores the history of occupational disease surveillance in Korea, highlighting the fragmented and disease-specific approach of earlier systems. The authors introduce the newly established Korea Occupational Disease Surveillance Center (KODSC), a comprehensive nationwide system designed to gather, analyze, and interpret data on occupational diseases through a network of regional centers. By incorporating hospital-based surveillance and focusing on acute poisonings and other sentinel events, the KODSC aims to overcome the limitations of previous systems and promote collaboration with various agencies. Although it is still in the early stages of implementation, the KODSC demonstrates potential for improving data accuracy and contributing valuable insights for public health policy.
5.Anterior Segment Swept-Source Optical Coherence Tomography–based Assessment of Corneal Refractive Profiles in Stevens-Johnson Syndrome/Toxic Epidermal Necrolysis Patients: A Controlled Comparative Study
Dong Hee HA ; Seung Hyeun LEE ; Kyoung Woo KIM
Korean Journal of Ophthalmology 2025;39(2):103-113
Purpose:
To analyze anterior, posterior, and total corneal refractive profiles and thickness using anterior segment (AS) sweptsource optical coherence tomography (SS-OCT) in Stevens-Johnson syndrome (SJS) or toxic epidermal necrolysis (TEN) patients.
Methods:
This retrospective study compared 23 eyes from 14 patients with SJS/TEN with 23 eyes from 14 age- and sexmatched controls. AS SS-OCT measured corneal refractive profiles and pachymetry. Parameters included anterior, posterior, and total corneal power values, posterior to anterior curvature ratio, maximal corneal power, and thickness profiles. The SJS/TEN group was subdivided based on corneal opacity presence (subgroup A) or absence (subgroup B).
Results:
The SJS/TEN group showed significantly higher corneal astigmatism and maximal corneal power values for both anterior and posterior curvatures. Steep total corneal power and total corneal astigmatism were higher in the SJS/TEN group. The thinnest corneal thickness was lower, and its distance from the corneal vertex was greater in the SJS/TEN group. Subgroup analysis revealed that these differences were primarily attributed to the presence of corneal opacity. Additionally, automated keratometry of the anterior corneal surface showed significantly higher values, including steep, flat, and average keratometry and corneal astigmatism, in the SJS/TEN group.
Conclusions
AS SS-OCT shows significant alterations in both anterior and posterior corneal curvatures in patients with SJS/TEN. These findings emphasize the importance of considering posterior corneal curvature changes in pre-cataract surgery assessments and contact lens prescriptions for patients with SJS/TEN.
6.Effect of 50-Hz Filters on Pattern Electroretinogram
Dong Hee HA ; Nam Ju MOON ; Ungsoo Samuel KIM
Korean Journal of Ophthalmology 2025;39(3):241-245
Purpose:
Pattern electroretinogram (PERG) is used to evaluate the function of retinal ganglion cells. However, the amplitude of PERG is quite small, making the examination challenging to perform. Waveform noise may be minimized by applying various filters. We aimed to investigate the effect of 50-Hz filters on PERG test results.
Methods:
This is the retrospective observational study. PERG tests were performed using the RETI-scan system according to the International Society for Clinical Electrophysiology of Vision guidelines. Three types of 50-Hz filters (soft, middle, and hard) were applied. The differences in parameters (N35 peak time, P50 peak time, N95 peak time, P50 amplitude, N95 amplitude, and N95 to P50 ratio) were analyzed. Based on the provided normal range, the changes from normal to abnormal range or vice versa were investigated.
Results:
A total of 24 waveforms were analyzed. After filtering, the P50 and N95 amplitudes showed a significant reduction of 8% to 15% (P50 amplitude: 5.1 ± 2.7 μV without filter, 4.6 ± 2.3 μV with 50-Hz soft filter, 4.3 ± 2.1 μV with 50-Hz middle filter, 4.3 ± 2.1 μV with 50-Hz hard filter; N95 amplitude: 7.2 ± 4.2 μV without filter, 6.6 ± 3.8 μV with 50-Hz soft filter, 6.3 ± 3.6 μV with 50-Hz middle filter, 6.1 ± 3.6 μV with 50-Hz hard filter). This pattern was more prominent in normal subjects. All latencies except the N35 peak time exhibited no differences between the tests. The N95 to P50 ratio decreased after 50-Hz middle and hard filtering. Considering the normative data, switching between normal and abnormal results was rare.
Conclusions
Although peak time was not significantly affected, amplitude was significantly reduced after using 50-Hz filters. Thus, 50-Hz filters can smoothen the waveform. Nevertheless, caution must be exercised while taking readings.
7.Radiofrequency Ablation for Recurrent Thyroid Cancers:2025 Korean Society of Thyroid Radiology Guideline
Eun Ju HA ; Min Kyoung LEE ; Jung Hwan BAEK ; Hyun Kyung LIM ; Hye Shin AHN ; Seon Mi BAEK ; Yoon Jung CHOI ; Sae Rom CHUNG ; Ji-hoon KIM ; Jae Ho SHIN ; Ji Ye LEE ; Min Ji HONG ; Hyun Jin KIM ; Leehi JOO ; Soo Yeon HAHN ; So Lyung JUNG ; Chang Yoon LEE ; Jeong Hyun LEE ; Young Hen LEE ; Jeong Seon PARK ; Jung Hee SHIN ; Jin Yong SUNG ; Miyoung CHOI ; Dong Gyu NA ;
Korean Journal of Radiology 2025;26(1):10-28
Radiofrequency ablation (RFA) is a minimally invasive treatment modality used as an alternative to surgery in patients with benign thyroid nodules, recurrent thyroid cancers (RTCs), and primary thyroid microcarcinomas. The Korean Society of Thyroid Radiology (KSThR) initially developed recommendations for the optimal use of RFA for thyroid tumors in 2009 and revised them in 2012 and 2017. As new meaningful evidence has accumulated since 2017 and in response to a growing global interest in the use of RFA for treating malignant thyroid lesions, the task force committee members of the KSThR decided to update the guidelines on the use of RFA for the management of RTCs based on a comprehensive analysis of current literature and expert consensus.
8.Occupational disease monitoring by the Korea Occupational Disease Surveillance Center: a narrative review
Dong-Wook LEE ; Inah KIM ; Jungho HWANG ; Sunhaeng CHOI ; Tae-Won JANG ; Insung CHUNG ; Hwan-Cheol KIM ; Jaebum PARK ; Jungwon KIM ; Kyoung Sook JEONG ; Youngki KIM ; Eun-Soo LEE ; Yangwoo KIM ; Inchul JEONG ; Hyunjeong OH ; Hyeoncheol OH ; Jea Chul HA ; Jeehee MIN ; Chul Gab LEE ; Heon KIM ; Jaechul SONG
The Ewha Medical Journal 2025;48(1):e9-
This review examines the challenges associated with occupational disease surveillance in Korea, particularly emphasizing the limitations of current data sources such as the Industrial Accident Compensation Insurance (IACI) statistics and special health examinations. The IACI system undercounts cases due to its emphasis on severe diseases and restrictions on approvals. Special health examinations, although they cover a broad workforce, are constrained by their annual scheduling, which leads to missed acute illnesses and subclinical conditions. The paper also explores the history of occupational disease surveillance in Korea, highlighting the fragmented and disease-specific approach of earlier systems. The authors introduce the newly established Korea Occupational Disease Surveillance Center (KODSC), a comprehensive nationwide system designed to gather, analyze, and interpret data on occupational diseases through a network of regional centers. By incorporating hospital-based surveillance and focusing on acute poisonings and other sentinel events, the KODSC aims to overcome the limitations of previous systems and promote collaboration with various agencies. Although it is still in the early stages of implementation, the KODSC demonstrates potential for improving data accuracy and contributing valuable insights for public health policy.
9.A Study on the Healthcare Workforce and Care for Acute Stroke: Results From the Survey of Hospitals Included in the National Acute Stroke Quality Assessment Program
Jong Young LEE ; Jun Kyeong KO ; Hak Cheol KO ; Hae-Won KOO ; Hyon-Jo KWON ; Dae-Won KIM ; Kangmin KIM ; Myeong Jin KIM ; Hoon KIM ; Keun Young PARK ; Kuhyun YANG ; Jae Sang OH ; Won Ki YOON ; Dong Hoon LEE ; Ho Jun YI ; Heui Seung LEE ; Jong-Kook RHIM ; Dong-Kyu JANG ; Youngjin JUNG ; Sang Woo HA ; Seung Hun SHEEN
Journal of Korean Medical Science 2025;40(16):e44-
Background:
With growing elderly populations, management of patients with acute stroke is increasingly important. In South Korea, the Acute Stroke Quality Assessment Program (ASQAP) has contributed to improving the quality of stroke care and practice behavior in healthcare institutions. While the mortality of hemorrhagic stroke remains high, there are only a few assessment indices associated with hemorrhagic stroke. Considering the need to develop assessment indices to improve the actual quality of care in the field of acute stroke treatment, this study aims to investigate the current status of human resources and practices related to the treatment of patients with acute stroke through a nationwide survey.
Methods:
For the healthcare institutions included in the Ninth ASQAP of the Health Insurance Review and Assessment Service (HIRA), data from January 2022 to December 2022 were collected through a survey on the current status and practice of healthcare providers related to the treatment of patients with acute stroke. The questionnaire consisted of 19 items, including six items on healthcare providers involved in stroke care and 10 items on the care of patients with acute stroke.
Results:
In the treatment of patients with hemorrhagic stroke among patients with acute stroke, neurosurgeons were the most common providers. The contribution of neurosurgeons in the treatment of ischemic stroke has also been found to be equivalent to that of neurologists. However, a number of institutions were found to be devoid of healthcare providers who perform definitive treatments, such as intra-arterial thrombectomy for patients with ischemic stroke or cerebral aneurysm clipping for subarachnoid hemorrhage. The intensity of the workload of healthcare providers involved in the care of patients with acute stroke, especially those involved in definitive treatment, was also found to be quite high.
Conclusion
Currently, there are almost no assessment indices specific to hemorrhagic stroke in the ASQAP for acute stroke. Furthermore, it does not reflect the reality of the healthcare providers and practices that provide definitive treatment for acute stroke. The findings of this study suggest the need for the development of appropriate assessment indices that reflect the realities of acute stroke care.
10.A Study on the Healthcare Workforce and Care for Acute Stroke: Results From the Survey of Hospitals Included in the National Acute Stroke Quality Assessment Program
Jong Young LEE ; Jun Kyeong KO ; Hak Cheol KO ; Hae-Won KOO ; Hyon-Jo KWON ; Dae-Won KIM ; Kangmin KIM ; Myeong Jin KIM ; Hoon KIM ; Keun Young PARK ; Kuhyun YANG ; Jae Sang OH ; Won Ki YOON ; Dong Hoon LEE ; Ho Jun YI ; Heui Seung LEE ; Jong-Kook RHIM ; Dong-Kyu JANG ; Youngjin JUNG ; Sang Woo HA ; Seung Hun SHEEN
Journal of Korean Medical Science 2025;40(16):e44-
Background:
With growing elderly populations, management of patients with acute stroke is increasingly important. In South Korea, the Acute Stroke Quality Assessment Program (ASQAP) has contributed to improving the quality of stroke care and practice behavior in healthcare institutions. While the mortality of hemorrhagic stroke remains high, there are only a few assessment indices associated with hemorrhagic stroke. Considering the need to develop assessment indices to improve the actual quality of care in the field of acute stroke treatment, this study aims to investigate the current status of human resources and practices related to the treatment of patients with acute stroke through a nationwide survey.
Methods:
For the healthcare institutions included in the Ninth ASQAP of the Health Insurance Review and Assessment Service (HIRA), data from January 2022 to December 2022 were collected through a survey on the current status and practice of healthcare providers related to the treatment of patients with acute stroke. The questionnaire consisted of 19 items, including six items on healthcare providers involved in stroke care and 10 items on the care of patients with acute stroke.
Results:
In the treatment of patients with hemorrhagic stroke among patients with acute stroke, neurosurgeons were the most common providers. The contribution of neurosurgeons in the treatment of ischemic stroke has also been found to be equivalent to that of neurologists. However, a number of institutions were found to be devoid of healthcare providers who perform definitive treatments, such as intra-arterial thrombectomy for patients with ischemic stroke or cerebral aneurysm clipping for subarachnoid hemorrhage. The intensity of the workload of healthcare providers involved in the care of patients with acute stroke, especially those involved in definitive treatment, was also found to be quite high.
Conclusion
Currently, there are almost no assessment indices specific to hemorrhagic stroke in the ASQAP for acute stroke. Furthermore, it does not reflect the reality of the healthcare providers and practices that provide definitive treatment for acute stroke. The findings of this study suggest the need for the development of appropriate assessment indices that reflect the realities of acute stroke care.

Result Analysis
Print
Save
E-mail