1.Application of dental implant robot technology in postgraduate dental implant education
Xueya WANG ; Quanchen XU ; Zhiqiang QI ; Xiaoqi SU ; Zhongxi SUN ; Xuehan LI ; Guowei WANG ; Xiaojing WANG
Chinese Journal of Stomatology 2025;60(4):403-408
Objective:To explore the effectiveness of robotic implant technology in the postgraduate education of implant dentistry.Methods:The teaching method that combines of theory and model manipulation was used to teach 20 postgraduate students. After completing the theoretical course of implant dentistry, all students performed free hand, digital template, and dental implant robot implant surgery on the simulation jaw models. At the end of the course, an error analysis of the three and a feedback questionnaire distributed to the students were conducted in order to assess the effectiveness of the dental implant robot.Results:Compared to the freehand [2.45(1.1) mm,2.80(0.88) mm,4.95°(2.68°)] and digital template group [1.25(0.68) mm,2.00(0.90) mm, 3.35°(1.60°)], the dental robot implant group had smaller values for implant platform deviation, apical deviation and angular deviation [0.29(0.08) mm,0.26(0.20) mm,0.72°(0.13°)], and the difference was statistically significant ( P<0.001). The results of the questionnaire showed that dental implant robot helps to ensure the accuracy and safety of the implanting process and stimulates students′ interest in learning. Conclusions:At postgraduate level, the safety and accuracy of the implantation process was effectively improved and good teaching result achieved by introducing dental implant robot into the process of dental implant training.
2.Evaluation for real-world application of domestic and imported medical devices in Liaoning province
Hongling LI ; Han LI ; Shuang LI ; Yanxia LI ; Lijuan WANG ; Guowei PAN ; Wei SUN
China Medical Equipment 2025;22(6):108-112
Objective:To investigate the current status of real time application of domestic and imported medical device in the real-world in Liaoning province,and provide data support for the promotion and application of domestic medical device.Methods:Data of the usage of medical device were collected from 77 medical institutions at all levels in 9 urban-rural demonstration regions with representativeness in Liaoning Province from November 2017 to June 2020.Descriptive analysis was used to characterize the distribution of medical device,which data were collected in urban-rural medical institutions at all levels in Liaoning Province.The total amount of receiving test of medical device,and the tested amount of each device in each month in urban-rural medical institutions at all levels were calculated.The median value of monthly average number of persons who received test of various kind of domestic and imported medical device in each month in hospitals with third level and secondary level were also calculated.Results:The total number of device that were collected from 77 medical institutions in 9 demonstration regions in Liaoning province was 325,among of which there were 153 domestic device(accounting for 47.1%)and 172 imported devices(accounting for 52.9%).A total of 6,261,000 person-time valid records were collected from 77 medical institutions,which average test number was 5,562 person-time in each device and each month.The total number of person-times of domestic device in diagnosis and treatment was 1,380,000 person-times(accounting for 22.0%),and that of imported devices was 4,881,000 person-times(accounting for 78.0%).The average test number of each device of domestic device in each month was 2,334 person-times(accounting for 42.0%),and that of imported device in each month was 3,228 person-times(accounting for 58.0%).In urban regions,imported device were dominant,while domestic medical device were dominant in rural regions in Liaoning province.The overall usage frequency of imported medical device was higher in hospitals with third level or secondary level,while the usage frequency of domestic medical device was higher in grassroots medical institutions.Conclusion:There are differences in the real time usage between domestic and imported medical device among 77 medical institutions at all levels in 9 demonstration regions in Liaoning province.Urban regions mainly tend to use imported device,while rural regions more tent to use domestic device.
3.Impact of general self-efficacy on work immersion experience of intern nursing students: the mediating effect of resilience
Xiaoying ZHANG ; Tingting LIANG ; Guowei WANG ; Baoping SUN
Chinese Journal of Modern Nursing 2025;31(13):1783-1788
Objective:To explore the impact of general self-efficacy on the work immersion experience and the mediating effect of resilience in intern nursing students, so as to provide a basis for the development of interventions.Methods:Convenience sampling was used to select 210 intern nursing students in the Shandong Provincial Third Hospital from January to September 2024 for the study. Nursing students were surveyed using the General Information Questionnaire, Work Immersion Experience Scale, Medical Staff Resilience Scale, and General Self-Efficacy Scale. The mediating effects test was performed using the Process plug-in in SPSS 26.0.Results:A total of 210 questionnaires were distributed and 204 valid questionnaires were recovered, with a valid recovery rate of 97.14%. The total scores of the Work Immersion Experience Scale, Medical Staff Resilience Scale, and General Self-Efficacy Scale were (107.33±17.06) , (63.12±12.96) and (25.65±4.60) , respectively. General self-efficacy was a positive predictor of the work immersion experience ( β=0.321) of intern nursing students. Resilience partially mediated the effect between general self-efficacy and the work immersion experience of intern nursing students, with an effect size of 0.126 and a 95% confidence interval of (0.050, 0.211) , which accounted for 28.19% (0.126/0.447) of the total effect. Conclusions:Intern nursing students with high general self-efficacy have good work immersion experiences, and resilience partially mediates the effect between self-efficacy and work immersion experiences. Nursing educators and administrators can improve the work immersion experience of intern nursing students by designing targeted training courses, providing adequate practice opportunities, and conducting psychotherapy to enhance their self-efficacy and resilience.
4.Evaluation for real-world application of domestic and imported medical devices in Liaoning province
Hongling LI ; Han LI ; Shuang LI ; Yanxia LI ; Lijuan WANG ; Guowei PAN ; Wei SUN
China Medical Equipment 2025;22(6):108-112
Objective:To investigate the current status of real time application of domestic and imported medical device in the real-world in Liaoning province,and provide data support for the promotion and application of domestic medical device.Methods:Data of the usage of medical device were collected from 77 medical institutions at all levels in 9 urban-rural demonstration regions with representativeness in Liaoning Province from November 2017 to June 2020.Descriptive analysis was used to characterize the distribution of medical device,which data were collected in urban-rural medical institutions at all levels in Liaoning Province.The total amount of receiving test of medical device,and the tested amount of each device in each month in urban-rural medical institutions at all levels were calculated.The median value of monthly average number of persons who received test of various kind of domestic and imported medical device in each month in hospitals with third level and secondary level were also calculated.Results:The total number of device that were collected from 77 medical institutions in 9 demonstration regions in Liaoning province was 325,among of which there were 153 domestic device(accounting for 47.1%)and 172 imported devices(accounting for 52.9%).A total of 6,261,000 person-time valid records were collected from 77 medical institutions,which average test number was 5,562 person-time in each device and each month.The total number of person-times of domestic device in diagnosis and treatment was 1,380,000 person-times(accounting for 22.0%),and that of imported devices was 4,881,000 person-times(accounting for 78.0%).The average test number of each device of domestic device in each month was 2,334 person-times(accounting for 42.0%),and that of imported device in each month was 3,228 person-times(accounting for 58.0%).In urban regions,imported device were dominant,while domestic medical device were dominant in rural regions in Liaoning province.The overall usage frequency of imported medical device was higher in hospitals with third level or secondary level,while the usage frequency of domestic medical device was higher in grassroots medical institutions.Conclusion:There are differences in the real time usage between domestic and imported medical device among 77 medical institutions at all levels in 9 demonstration regions in Liaoning province.Urban regions mainly tend to use imported device,while rural regions more tent to use domestic device.
5.Study on the identification of the characteristic peptides of the Galli Gigerii Endothelium Corneum crude drugs and preparations
Guowei LI ; Peizhen TONG ; Qiping HU ; Yunjing QIU ; Liye PAN ; Jiaying HE ; Xiangdong CHEN ; Dongmei SUN
International Journal of Traditional Chinese Medicine 2025;47(5):676-681
Objective:To establish a mass spectrometry method for the determination of characteristic peptides of Galli Gigerii Endothelium Corneum that can identify the authenticity of Galli Gigerii Endothelium Corneum as well as its preparations; To evaluate their quality.Methods:Ultra performance chromatography-electrospray tandem mass spectrometry (UPLC-MS/MS) with the mode of multiple reaction monitoring quantification (MRM) was employed to monitor the ion pairs of m/z 379.21(charge: +2)→571.36, m/z 379.21(charge: +2)→385.26, m/z 785.41(charge: +2)→941.51 and m/z 785.41(charge: +2)→245.08, in order to detect the Galli Gigerii Endothelium Corneum crude drug and its preparations. Results:Chicken specific peptide I and chicken specific peptide Ⅱ could be detected in the 18 batches of Galli Gigerii Endothelium Corneum from different regions, their corresponding extractions and 4 batches of prescription preparations, while the chicken specific peptides were not detected in the 8 batches of endothelium corneums from ducks, geese and pigeons.Conclusions:The method established in this study can effectively supplement the deficiencies in standards of Galli Gigerii Endothelium Corneum and its decoction pieces, improve the quality control standard, and provide a reference for the safety and effectiveness of Galli Gigerii Endothelium Corneum in clinical medication.
6.Identification of Qianghuo ( Notopterygii Rhizoma et Radix) dispensing granules with specific PCR
Yijing LUO ; Ye SONG ; Yuqin LUO ; Guowei LI ; Siyin TAN ; Xinya WAN ; Dongmei SUN ; Xiangdong CHEN
International Journal of Traditional Chinese Medicine 2025;47(12):1726-1731
Objective:To establish a method for the identification of Qianghuo (Notopterygii Rhizoma et Radix) dispensing granules with PCR for the identification of dispensing granules.Methods:The collected samples were identified by DNA bar code, and the methods of extracting genomic DNA from Notopterygii Rhizoma et Radix, Qianghuo standard decoction and dispensing granules were established. Specific differential primers were designed based on ITS2 sequence, and the PCR amplification system and reaction conditions were optimized.Results:The PCR amplification system and reaction conditions were determined. The target bands of about 216 bp were obtained by amplification of Notopterygii Rhizoma et Radix, Qianghuo standard decoction and dispensing granules, and there was no interference from counterfeit products and blank.Conclusions:The specific PCR identification method of Qianghuo (Notopterygii Rhizoma et Radix) dispensing granules is established, which has good specificity. The detection limit of Notopterygii Rhizoma et Radix is 0.91 ng, and the detection limit of dispensing granules is 7.36 ng, which also provides a reference for the identification of other kinds of TCM dispensing granules.
7.The relationship between preoperative pulmonary vascular resistance and prognosis in patients undergoing left ventricular assist device implantation: a single-center report
Junjiang LIU ; Dingqian LIU ; Guangwei HAO ; Zhe LUO ; Kefang GUO ; Lili DONG ; Xin LI ; Guowei TU ; Chunsheng WANG ; Xiaoning SUN
Chinese Journal of Thoracic and Cardiovascular Surgery 2025;41(9):556-560
Objective:To compare the impact of preoperative pulmonary vascular resistance(PVR) levels on the prognosis of patients undergoing left ventricular assist device(LVAD)implantation.Methods:A retrospective analysis was conducted on the clinical data of 33 patients among September 2021 and June 2024, who underwent LVAD implantation at Zhongshan Hospital, Fudan University. 29 males and 4 females, with a mean age of(53.61±9.65)years old. The cohort included 30 cases of dilated cardiomyopathy, 2 cases of ischemic cardiomyopathy, and 1 case of noncompaction cardiomyopathy. Patients were grouped based on a preoperative PVR threshold of 3 WU, Preoperative data from Swan-Ganz catheterization, liver and renal function indicators, as well as other relevant clinical parameters were recorded. Patients were followed up to assess differences in survival outcomes.Results:Preoperative PVR was elevated in 18 cases(60%)of the patients, with a mean preoperative PVR of(3.16±1.71)WU. Immediate postoperative right heart catheterization was performed in 20 patients, showing a significant reduction in PVR from(3.85±1.72)WU preoperatively to(1.80±1.38)WU postoperatively( P<0.05). The cardiac index improved significantly from(1.95±0.63)L·min -1·m -2 preoperatively to(4.25±1.26)L·min -1·m -2 postoperatively( P<0.001). The mean follow-up duration was(14.78±12.06)months, no significant difference in postoperative survival was observed between the two groups(100% vs. 80%, P=0.667). Conclusion:Increased pulmonary resistance is often secondary to left heart dysfunction. After the implantation of a LVAD, pulmonary resistance can be improved. For patients with relatively normal right heart function before surgery, elevated pulmonary resistance does not affect the short-term outcomes of the implantation.
8.The mediating effect of occupational well-being between professional identity and safety behavior among nurses
Xinyan JIANG ; Guowei CHEN ; Haili GUO ; Yuxiu YU ; Sumin LI ; Yuanxin CHEN ; Wei XIONG ; LI SUN ; Ling JIANG
China Occupational Medicine 2025;52(3):276-281
Objective To explore the mediating role of occupational well-being in the relationship between professional identity and safety behavior among nurses. Methods A total of 1 006 nurses from ten tertiary general hospitals in eight provincial administrative regions were selected as the research subjects using convenient sampling method. Their safety behavior, professional identity and occupational well-being were investigated using Nurse Safety Behavior Scale, Nurse Professional Identity Scale and Occupational Well-being Scale. Structural equation modeling was performed using AMOS 26.0 to examine the mediating effect of occupational well-being in the relationship between professional identity and safety behavior among nurses. Results The scores for safety behavior, professional identity, and occupational well-being were (53.0±6.1), (123.7±21.2) and (90.8±13.1), respectively. Safety behavior was positively correlated with both professional identity and occupational well-being (correlation coefficients were 0.50 and 0.50, respectively, both P<0.01). Professional identity was positively correlated with occupational well-being (correlation coefficient was 0.51, P<0.01). The multiple linear regression analysis results showed that the higher the professional identity and occupational well-being of nurses, the higher the level of safety behavior (both P<0.05). The result of mediating effect shows that the total effect of occupational identity on safety behavior was 0.498 [95% confidence interval (CI) was 0.405-0.576], and occupational well-being played a mediating role between professional identity and safety behavior among nurses with the mediation effect of 0.156 (95%CI was 0.112-0.205), accounting for 31.33% of the total effect. Conclusion The safety behavior of nurses is at a moderate level. Both professional identity and occupational well-being can affect the safety behavior of nurses. Professional identity can increase the safety behavior of nurses by affecting occupational well-being.
9.Characteristic ion Identification of Different Original Haliotidis Concha and Its Counterfeits
Xiaojie LIANG ; Guowei LI ; Lin ZHOU ; Qiping HU ; Muxiang LUO ; Jiehao TANG ; Xiangdong CHEN ; Liye PAN ; Dongmei SUN
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(11):263-269
ObjectiveTo establish a method for the identification of Haliotidis Concha and its counterfeits, and to improve its quality evaluation method. MethodsA total of 17 batches of Haliotis discus hannai, 4 batches of H. ruber, 3 batches of H. laevigata, 3 batches of H. ovina, 3 batches of H. diversicolor, 3 batches of H. asinina, 3 batches of H. iris were collected. Ultra-high performance liquid chromatography-quadrupole/electrostatic field orbitrap high-resolution mass spectrometry(UPLC-Q-Exactive-Orbitrap-MS/MS) was used to analyze the hydrolysates of different original Haliotidis Concha and its counterfeits, and the potential characteristic ions of each species were screened by Venn diagram. UPLC-triple quadrupole tandem mass spectrometry(UPLC-QqQ-MS/MS) was used to validate the characteristic ions, and the specific detection method of the characteristic ions was established. ResultsA total of 1 182, 167, 47, 89, 104, 203, 424 potential characteristic ions were screened from H. discus hannai, H. ruber, H. laevigata, H. ovina, H. diversicolor, H. asinina and H. iris, respectively. And 9 characteristic ions were selected. The precision, stability and repeatability of the 9 characteristic ions in the established identification method met the requirements. Different original Haliotidis Concha and its counterfeits could detect their own characteristic ions, including m/z 631.83-886.48(double charge) and m/z 631.83-443.74(double charge) of H. discus hannai, m/z 699.28-232.11(double charge) and m/z 699.28-544.27(double charge) of H. ruber, m/z 535.76-752.37(double charge) and m/z 535.76-548.28(double charge) of H. laevigata, m/z 708.35-442.28(double charge) and m/z 708.35-215.14(double charge) of H. ovina, m/z 561.33-614.86(triple charge), m/z 561.33-468.28(triple charge), m/z 608.29-618.32(double charge) and m/z 608.29-390.21(double charge) of H. diversicolor, m/z 769.85-274.10(double charge), m/z 769.85-532.75(double charge), m/z 827.43-646.36(single charge), m/z 827.43-257.12(single charge) of H. asinina, and m/z 468.24-576.29(double charge) and m/z 468.24-505.26(double charge) of H. iris. ConclusionIn this study, a total of 9 characteristic ions are screened from 6 kinds of original Haliotidis Concha and its counterfeits, and a specific identification method is established, which is helpful to solve the limitations of the existing quality evaluation methods of Haliotidis Concha, and provide a basis for the production, circulation and medication quality.
10.Characteristic ion Identification of Different Original Haliotidis Concha and Its Counterfeits
Xiaojie LIANG ; Guowei LI ; Lin ZHOU ; Qiping HU ; Muxiang LUO ; Jiehao TANG ; Xiangdong CHEN ; Liye PAN ; Dongmei SUN
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(11):263-269
ObjectiveTo establish a method for the identification of Haliotidis Concha and its counterfeits, and to improve its quality evaluation method. MethodsA total of 17 batches of Haliotis discus hannai, 4 batches of H. ruber, 3 batches of H. laevigata, 3 batches of H. ovina, 3 batches of H. diversicolor, 3 batches of H. asinina, 3 batches of H. iris were collected. Ultra-high performance liquid chromatography-quadrupole/electrostatic field orbitrap high-resolution mass spectrometry(UPLC-Q-Exactive-Orbitrap-MS/MS) was used to analyze the hydrolysates of different original Haliotidis Concha and its counterfeits, and the potential characteristic ions of each species were screened by Venn diagram. UPLC-triple quadrupole tandem mass spectrometry(UPLC-QqQ-MS/MS) was used to validate the characteristic ions, and the specific detection method of the characteristic ions was established. ResultsA total of 1 182, 167, 47, 89, 104, 203, 424 potential characteristic ions were screened from H. discus hannai, H. ruber, H. laevigata, H. ovina, H. diversicolor, H. asinina and H. iris, respectively. And 9 characteristic ions were selected. The precision, stability and repeatability of the 9 characteristic ions in the established identification method met the requirements. Different original Haliotidis Concha and its counterfeits could detect their own characteristic ions, including m/z 631.83-886.48(double charge) and m/z 631.83-443.74(double charge) of H. discus hannai, m/z 699.28-232.11(double charge) and m/z 699.28-544.27(double charge) of H. ruber, m/z 535.76-752.37(double charge) and m/z 535.76-548.28(double charge) of H. laevigata, m/z 708.35-442.28(double charge) and m/z 708.35-215.14(double charge) of H. ovina, m/z 561.33-614.86(triple charge), m/z 561.33-468.28(triple charge), m/z 608.29-618.32(double charge) and m/z 608.29-390.21(double charge) of H. diversicolor, m/z 769.85-274.10(double charge), m/z 769.85-532.75(double charge), m/z 827.43-646.36(single charge), m/z 827.43-257.12(single charge) of H. asinina, and m/z 468.24-576.29(double charge) and m/z 468.24-505.26(double charge) of H. iris. ConclusionIn this study, a total of 9 characteristic ions are screened from 6 kinds of original Haliotidis Concha and its counterfeits, and a specific identification method is established, which is helpful to solve the limitations of the existing quality evaluation methods of Haliotidis Concha, and provide a basis for the production, circulation and medication quality.

Result Analysis
Print
Save
E-mail