1.Study on the identification of the characteristic peptides of the Galli Gigerii Endothelium Corneum crude drugs and preparations
Guowei LI ; Peizhen TONG ; Qiping HU ; Yunjing QIU ; Liye PAN ; Jiaying HE ; Xiangdong CHEN ; Dongmei SUN
International Journal of Traditional Chinese Medicine 2025;47(5):676-681
Objective:To establish a mass spectrometry method for the determination of characteristic peptides of Galli Gigerii Endothelium Corneum that can identify the authenticity of Galli Gigerii Endothelium Corneum as well as its preparations; To evaluate their quality.Methods:Ultra performance chromatography-electrospray tandem mass spectrometry (UPLC-MS/MS) with the mode of multiple reaction monitoring quantification (MRM) was employed to monitor the ion pairs of m/z 379.21(charge: +2)→571.36, m/z 379.21(charge: +2)→385.26, m/z 785.41(charge: +2)→941.51 and m/z 785.41(charge: +2)→245.08, in order to detect the Galli Gigerii Endothelium Corneum crude drug and its preparations. Results:Chicken specific peptide I and chicken specific peptide Ⅱ could be detected in the 18 batches of Galli Gigerii Endothelium Corneum from different regions, their corresponding extractions and 4 batches of prescription preparations, while the chicken specific peptides were not detected in the 8 batches of endothelium corneums from ducks, geese and pigeons.Conclusions:The method established in this study can effectively supplement the deficiencies in standards of Galli Gigerii Endothelium Corneum and its decoction pieces, improve the quality control standard, and provide a reference for the safety and effectiveness of Galli Gigerii Endothelium Corneum in clinical medication.
2.Characteristic ion Identification of Different Original Haliotidis Concha and Its Counterfeits
Xiaojie LIANG ; Guowei LI ; Lin ZHOU ; Qiping HU ; Muxiang LUO ; Jiehao TANG ; Xiangdong CHEN ; Liye PAN ; Dongmei SUN
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(11):263-269
ObjectiveTo establish a method for the identification of Haliotidis Concha and its counterfeits, and to improve its quality evaluation method. MethodsA total of 17 batches of Haliotis discus hannai, 4 batches of H. ruber, 3 batches of H. laevigata, 3 batches of H. ovina, 3 batches of H. diversicolor, 3 batches of H. asinina, 3 batches of H. iris were collected. Ultra-high performance liquid chromatography-quadrupole/electrostatic field orbitrap high-resolution mass spectrometry(UPLC-Q-Exactive-Orbitrap-MS/MS) was used to analyze the hydrolysates of different original Haliotidis Concha and its counterfeits, and the potential characteristic ions of each species were screened by Venn diagram. UPLC-triple quadrupole tandem mass spectrometry(UPLC-QqQ-MS/MS) was used to validate the characteristic ions, and the specific detection method of the characteristic ions was established. ResultsA total of 1 182, 167, 47, 89, 104, 203, 424 potential characteristic ions were screened from H. discus hannai, H. ruber, H. laevigata, H. ovina, H. diversicolor, H. asinina and H. iris, respectively. And 9 characteristic ions were selected. The precision, stability and repeatability of the 9 characteristic ions in the established identification method met the requirements. Different original Haliotidis Concha and its counterfeits could detect their own characteristic ions, including m/z 631.83-886.48(double charge) and m/z 631.83-443.74(double charge) of H. discus hannai, m/z 699.28-232.11(double charge) and m/z 699.28-544.27(double charge) of H. ruber, m/z 535.76-752.37(double charge) and m/z 535.76-548.28(double charge) of H. laevigata, m/z 708.35-442.28(double charge) and m/z 708.35-215.14(double charge) of H. ovina, m/z 561.33-614.86(triple charge), m/z 561.33-468.28(triple charge), m/z 608.29-618.32(double charge) and m/z 608.29-390.21(double charge) of H. diversicolor, m/z 769.85-274.10(double charge), m/z 769.85-532.75(double charge), m/z 827.43-646.36(single charge), m/z 827.43-257.12(single charge) of H. asinina, and m/z 468.24-576.29(double charge) and m/z 468.24-505.26(double charge) of H. iris. ConclusionIn this study, a total of 9 characteristic ions are screened from 6 kinds of original Haliotidis Concha and its counterfeits, and a specific identification method is established, which is helpful to solve the limitations of the existing quality evaluation methods of Haliotidis Concha, and provide a basis for the production, circulation and medication quality.
3.Characteristic ion Identification of Different Original Haliotidis Concha and Its Counterfeits
Xiaojie LIANG ; Guowei LI ; Lin ZHOU ; Qiping HU ; Muxiang LUO ; Jiehao TANG ; Xiangdong CHEN ; Liye PAN ; Dongmei SUN
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(11):263-269
ObjectiveTo establish a method for the identification of Haliotidis Concha and its counterfeits, and to improve its quality evaluation method. MethodsA total of 17 batches of Haliotis discus hannai, 4 batches of H. ruber, 3 batches of H. laevigata, 3 batches of H. ovina, 3 batches of H. diversicolor, 3 batches of H. asinina, 3 batches of H. iris were collected. Ultra-high performance liquid chromatography-quadrupole/electrostatic field orbitrap high-resolution mass spectrometry(UPLC-Q-Exactive-Orbitrap-MS/MS) was used to analyze the hydrolysates of different original Haliotidis Concha and its counterfeits, and the potential characteristic ions of each species were screened by Venn diagram. UPLC-triple quadrupole tandem mass spectrometry(UPLC-QqQ-MS/MS) was used to validate the characteristic ions, and the specific detection method of the characteristic ions was established. ResultsA total of 1 182, 167, 47, 89, 104, 203, 424 potential characteristic ions were screened from H. discus hannai, H. ruber, H. laevigata, H. ovina, H. diversicolor, H. asinina and H. iris, respectively. And 9 characteristic ions were selected. The precision, stability and repeatability of the 9 characteristic ions in the established identification method met the requirements. Different original Haliotidis Concha and its counterfeits could detect their own characteristic ions, including m/z 631.83-886.48(double charge) and m/z 631.83-443.74(double charge) of H. discus hannai, m/z 699.28-232.11(double charge) and m/z 699.28-544.27(double charge) of H. ruber, m/z 535.76-752.37(double charge) and m/z 535.76-548.28(double charge) of H. laevigata, m/z 708.35-442.28(double charge) and m/z 708.35-215.14(double charge) of H. ovina, m/z 561.33-614.86(triple charge), m/z 561.33-468.28(triple charge), m/z 608.29-618.32(double charge) and m/z 608.29-390.21(double charge) of H. diversicolor, m/z 769.85-274.10(double charge), m/z 769.85-532.75(double charge), m/z 827.43-646.36(single charge), m/z 827.43-257.12(single charge) of H. asinina, and m/z 468.24-576.29(double charge) and m/z 468.24-505.26(double charge) of H. iris. ConclusionIn this study, a total of 9 characteristic ions are screened from 6 kinds of original Haliotidis Concha and its counterfeits, and a specific identification method is established, which is helpful to solve the limitations of the existing quality evaluation methods of Haliotidis Concha, and provide a basis for the production, circulation and medication quality.
4.Construction and evaluation of spleen-deficiency hyperlipidemia mouse models
Lijuan CHEN ; Xinxue GAO ; Jin WU ; Ying DU ; Meijun LYU ; Guoyuan SUI ; Lianqun JIA ; Guowei PAN
Chinese Journal of Tissue Engineering Research 2025;29(29):6237-6242
BACKGROUND:Traditional Chinese medicine has unique advantages in preventing and treating spleen-deficiency and hyperlipidemia.In basic studies,models of spleen-deficiency and hyperlipidemia are commonly found in rats,pigs,and other animals.This has limitations for medical research that can only use mouse models.It is urgent to establish and evaluate mouse models of spleen-deficiency and hyperlipidemia to support basic research on traditional Chinese medicine in preventing and treating spleen-deficiency and hyperlipidemia.OBJECTIVE:To establish a mouse model of spleen-deficiency hyperlipidemia.METHODS:Totally 24 C57BL/6J mice were randomly divided into normal group(n=12)and spleen-deficiency hyperlipemia group(n=12).Mice in normal group were fed basic diet.Mice in the spleen-deficiency hyperlipemia group were prepared with a diet disorder+fatigue internal injury+high-fat feeding method to establish a spleen-deficiency high-fat model.In the first 2 weeks,the mice were forced to swim to their endurance limit on a single day and were only fed cabbage,with free access to water.They were also gavaged with refined lard+high-fat feed on two-day intervals.After 2 weeks,the mice were fed a high-fat diet every day and the diet continued until 12 weeks.The mice were fed with a high-fat diet for 4 and 12 weeks,and their body weight,food intake,gripping strength,fecal water content,small intestinal charcoal propulsion rate,serum D-xylose and gastrin levels,spleen index and thymus index,blood lipid level,total body fat mass,body fat percentage,and liver lipid deposition were tested.RESULTS AND CONCLUSION:(1)Compared with the normal group,the body weight,fecal water content,total body fat mass,body fat percentage,triglyceride and total cholesterol levels of the mice in the spleen-deficiency hyperlipemia group fed with high-fat diet for 4 and 12 weeks were increased(P<0.05);the daily food intake,gripping force,and D-xylose level of the mice fed with high-fat diet for 4 and 12 weeks were decreased(P<0.05);the spleen index of the mice fed with high-fat diet for 4 weeks was increased(P<0.05);the small intestinal carbon propulsion rate,gastrin level,spleen index,and thymus index of the mice fed with high-fat diet for 12 weeks were decreased(P<0.05);the low-density lipoprotein cholesterol level of the mice fed with high-fat diet for 12 weeks was increased(P<0.05).(2)The results of liver oil red O staining showed that the lipid deposition in the spleen-deficiency hyperlipemia group after 4 weeks of high-fat diet feeding was slightly more than that in the normal group,and the lipid deposition in the high-fat diet feeding for 12 weeks was significantly more than that in the normal group.(3)The results show that a stable spleen deficiency and hyperlipidemia mouse model can be prepared by the compound method of eating disorders,exhaustion,and high-fat feeding.
5.Investigation and evaluation for the popularization and demonstration of domestically innovative medical devices in Liaoning province
Shengyuan HAO ; Jinyi ZHANG ; Li LIU ; Huihui YU ; Qing TONG ; Guowei PAN ; Wei SUN
China Medical Equipment 2025;22(3):102-107
Objective:To investigate and assess the situation of popularization and promotion of domestically innovative medical devices in Liaoning Province,so as to provide a basis for promoting the allocation policy of domestically innovation medical devices.Methods:Self-made questionnaire and on-site filling survey were conducted to implement investigation and analysis for the allocation situation of newly medical equipment of 188 medical institutions in 9 demonstration regions of the Project on Regional Application and Demonstration of Innovative Medical Equipment in Liaoning Province from 2015 to 2020.The allocation data of medical equipment between before(from 2015 to 2017)and after the demonstration projects were implemented(from 2018 to 2020)were compared.The occupancy rate of domestically medical devices(referred as"occupancy ratio of domestic device")was used as an evaluation indicator to assess the status of equipment allocation and application before and after the projects of application and demonstration were implemented in the region of innovative equipment for diagnosis and treatment.Results:In the 9 demonstrational regions of Liaoning province,the number of newly added domestic medical devices during the period from 2018 to 2020 increased from 1,608 units between 2015 and 2017 to 1,703 units.The occupancy ratio of newly added domestic devices increased from 72.7%to 84.9%.The occupancy ratio of domestic devices of newly added key equipment increased from 63.0%to 83.4%,and the growth rate reached 20.4%.In different districts and different grades of medical institution,the increase and application of domestically medical devices appeared difference.Conclusion:The occupancy rate of newly added domestically medical devices in 9 demonstration regions in Liaoning province has generally increased.However,there are still imbalances between different regions and different grades of medical institutions.The manufacturers of domestically medical devices still need strengthen brand building and marketing promotion,so as to further enhance market competitiveness of domestically medical devices.
6.Study on artificial intelligence-based ultrasound diagnosis and auxiliary decision-making for ovarian tumors
Chunli QIU ; Yanlin CHEN ; Yuanji ZHANG ; Haotian LIN ; Xiaoyi PAN ; Siying LIANG ; Xiang CONG ; Xin LIU ; Zhen MA ; Cai ZANG ; Xin YANG ; Dong NI ; Guowei TAO
Chinese Journal of Ultrasonography 2025;34(7):608-615
Objective:To apply artificial intelligence(AI)in classifying ovarian tumors on ultrasound images,and compare the diagnostic results of several sonographers with varying seniority levels.Methods:A total of 645 patients diagnosed with adnexal masses via gynecological ultrasound examination at Qilu Hospital of Shandong University from January 2021 to December 2024 were enrolled. Three deep learning architectures,i.e.,Alexnet,Densenet121,and Resnet50 were developed and used to internally test the classification effectiveness of ovarian tumors,while the optimal model was selected for external testing. Two junior sonographers and two senior sonographers were recruited to independently diagnose ovarian tumors in the external test dataset. Subsequently,the benign and malignant results of the model's predictions were disclosed to each sonographer,and their revised diagnoses on the same external test data in combination with the best AI model were recorded.Results:The optimal model achieved an accuracy of 0.941,sensitivity of 0.936,and specificity of 0.944 on the internal test dataset,and maintained robust performance on the external test dataset with accuracy of 0.891,sensitivity of 0.880,and specificity of 0.907. Compared to junior sonographers,the optimal model demonstrated significantly higher sensitivity in discriminating benign from malignant ovarian tumors(0.880 vs. 0.723,0.602;all P<0.05). No statistically significant difference was observed in diagnostic accuracy between the optimal model and senior sonographer 1( P=0.05). With assistance from the optimal model,junior sonographers achieved significant improvements in both sensitivity and specificity(sensitivity:0.723 vs. 0.843,0.602 vs. 0.819;specificity:0.778 vs. 0.833,0.685 vs. 0.741;all P<0.05). Conclusions:The optimal model achieves comparable performance to that of senior sonographers in ovarian tumor classification. With model assistance,the diagnostic performance of junior sonographers is significantly improved.
7.Construction and evaluation of spleen-deficiency hyperlipidemia mouse models
Lijuan CHEN ; Xinxue GAO ; Jin WU ; Ying DU ; Meijun LYU ; Guoyuan SUI ; Lianqun JIA ; Guowei PAN
Chinese Journal of Tissue Engineering Research 2025;29(29):6237-6242
BACKGROUND:Traditional Chinese medicine has unique advantages in preventing and treating spleen-deficiency and hyperlipidemia.In basic studies,models of spleen-deficiency and hyperlipidemia are commonly found in rats,pigs,and other animals.This has limitations for medical research that can only use mouse models.It is urgent to establish and evaluate mouse models of spleen-deficiency and hyperlipidemia to support basic research on traditional Chinese medicine in preventing and treating spleen-deficiency and hyperlipidemia.OBJECTIVE:To establish a mouse model of spleen-deficiency hyperlipidemia.METHODS:Totally 24 C57BL/6J mice were randomly divided into normal group(n=12)and spleen-deficiency hyperlipemia group(n=12).Mice in normal group were fed basic diet.Mice in the spleen-deficiency hyperlipemia group were prepared with a diet disorder+fatigue internal injury+high-fat feeding method to establish a spleen-deficiency high-fat model.In the first 2 weeks,the mice were forced to swim to their endurance limit on a single day and were only fed cabbage,with free access to water.They were also gavaged with refined lard+high-fat feed on two-day intervals.After 2 weeks,the mice were fed a high-fat diet every day and the diet continued until 12 weeks.The mice were fed with a high-fat diet for 4 and 12 weeks,and their body weight,food intake,gripping strength,fecal water content,small intestinal charcoal propulsion rate,serum D-xylose and gastrin levels,spleen index and thymus index,blood lipid level,total body fat mass,body fat percentage,and liver lipid deposition were tested.RESULTS AND CONCLUSION:(1)Compared with the normal group,the body weight,fecal water content,total body fat mass,body fat percentage,triglyceride and total cholesterol levels of the mice in the spleen-deficiency hyperlipemia group fed with high-fat diet for 4 and 12 weeks were increased(P<0.05);the daily food intake,gripping force,and D-xylose level of the mice fed with high-fat diet for 4 and 12 weeks were decreased(P<0.05);the spleen index of the mice fed with high-fat diet for 4 weeks was increased(P<0.05);the small intestinal carbon propulsion rate,gastrin level,spleen index,and thymus index of the mice fed with high-fat diet for 12 weeks were decreased(P<0.05);the low-density lipoprotein cholesterol level of the mice fed with high-fat diet for 12 weeks was increased(P<0.05).(2)The results of liver oil red O staining showed that the lipid deposition in the spleen-deficiency hyperlipemia group after 4 weeks of high-fat diet feeding was slightly more than that in the normal group,and the lipid deposition in the high-fat diet feeding for 12 weeks was significantly more than that in the normal group.(3)The results show that a stable spleen deficiency and hyperlipidemia mouse model can be prepared by the compound method of eating disorders,exhaustion,and high-fat feeding.
8.Evaluation for real-world application of domestic and imported medical devices in Liaoning province
Hongling LI ; Han LI ; Shuang LI ; Yanxia LI ; Lijuan WANG ; Guowei PAN ; Wei SUN
China Medical Equipment 2025;22(6):108-112
Objective:To investigate the current status of real time application of domestic and imported medical device in the real-world in Liaoning province,and provide data support for the promotion and application of domestic medical device.Methods:Data of the usage of medical device were collected from 77 medical institutions at all levels in 9 urban-rural demonstration regions with representativeness in Liaoning Province from November 2017 to June 2020.Descriptive analysis was used to characterize the distribution of medical device,which data were collected in urban-rural medical institutions at all levels in Liaoning Province.The total amount of receiving test of medical device,and the tested amount of each device in each month in urban-rural medical institutions at all levels were calculated.The median value of monthly average number of persons who received test of various kind of domestic and imported medical device in each month in hospitals with third level and secondary level were also calculated.Results:The total number of device that were collected from 77 medical institutions in 9 demonstration regions in Liaoning province was 325,among of which there were 153 domestic device(accounting for 47.1%)and 172 imported devices(accounting for 52.9%).A total of 6,261,000 person-time valid records were collected from 77 medical institutions,which average test number was 5,562 person-time in each device and each month.The total number of person-times of domestic device in diagnosis and treatment was 1,380,000 person-times(accounting for 22.0%),and that of imported devices was 4,881,000 person-times(accounting for 78.0%).The average test number of each device of domestic device in each month was 2,334 person-times(accounting for 42.0%),and that of imported device in each month was 3,228 person-times(accounting for 58.0%).In urban regions,imported device were dominant,while domestic medical device were dominant in rural regions in Liaoning province.The overall usage frequency of imported medical device was higher in hospitals with third level or secondary level,while the usage frequency of domestic medical device was higher in grassroots medical institutions.Conclusion:There are differences in the real time usage between domestic and imported medical device among 77 medical institutions at all levels in 9 demonstration regions in Liaoning province.Urban regions mainly tend to use imported device,while rural regions more tent to use domestic device.
9.Evaluation for real-world application of domestic and imported medical devices in Liaoning province
Hongling LI ; Han LI ; Shuang LI ; Yanxia LI ; Lijuan WANG ; Guowei PAN ; Wei SUN
China Medical Equipment 2025;22(6):108-112
Objective:To investigate the current status of real time application of domestic and imported medical device in the real-world in Liaoning province,and provide data support for the promotion and application of domestic medical device.Methods:Data of the usage of medical device were collected from 77 medical institutions at all levels in 9 urban-rural demonstration regions with representativeness in Liaoning Province from November 2017 to June 2020.Descriptive analysis was used to characterize the distribution of medical device,which data were collected in urban-rural medical institutions at all levels in Liaoning Province.The total amount of receiving test of medical device,and the tested amount of each device in each month in urban-rural medical institutions at all levels were calculated.The median value of monthly average number of persons who received test of various kind of domestic and imported medical device in each month in hospitals with third level and secondary level were also calculated.Results:The total number of device that were collected from 77 medical institutions in 9 demonstration regions in Liaoning province was 325,among of which there were 153 domestic device(accounting for 47.1%)and 172 imported devices(accounting for 52.9%).A total of 6,261,000 person-time valid records were collected from 77 medical institutions,which average test number was 5,562 person-time in each device and each month.The total number of person-times of domestic device in diagnosis and treatment was 1,380,000 person-times(accounting for 22.0%),and that of imported devices was 4,881,000 person-times(accounting for 78.0%).The average test number of each device of domestic device in each month was 2,334 person-times(accounting for 42.0%),and that of imported device in each month was 3,228 person-times(accounting for 58.0%).In urban regions,imported device were dominant,while domestic medical device were dominant in rural regions in Liaoning province.The overall usage frequency of imported medical device was higher in hospitals with third level or secondary level,while the usage frequency of domestic medical device was higher in grassroots medical institutions.Conclusion:There are differences in the real time usage between domestic and imported medical device among 77 medical institutions at all levels in 9 demonstration regions in Liaoning province.Urban regions mainly tend to use imported device,while rural regions more tent to use domestic device.
10.Investigation and evaluation for the popularization and demonstration of domestically innovative medical devices in Liaoning province
Shengyuan HAO ; Jinyi ZHANG ; Li LIU ; Huihui YU ; Qing TONG ; Guowei PAN ; Wei SUN
China Medical Equipment 2025;22(3):102-107
Objective:To investigate and assess the situation of popularization and promotion of domestically innovative medical devices in Liaoning Province,so as to provide a basis for promoting the allocation policy of domestically innovation medical devices.Methods:Self-made questionnaire and on-site filling survey were conducted to implement investigation and analysis for the allocation situation of newly medical equipment of 188 medical institutions in 9 demonstration regions of the Project on Regional Application and Demonstration of Innovative Medical Equipment in Liaoning Province from 2015 to 2020.The allocation data of medical equipment between before(from 2015 to 2017)and after the demonstration projects were implemented(from 2018 to 2020)were compared.The occupancy rate of domestically medical devices(referred as"occupancy ratio of domestic device")was used as an evaluation indicator to assess the status of equipment allocation and application before and after the projects of application and demonstration were implemented in the region of innovative equipment for diagnosis and treatment.Results:In the 9 demonstrational regions of Liaoning province,the number of newly added domestic medical devices during the period from 2018 to 2020 increased from 1,608 units between 2015 and 2017 to 1,703 units.The occupancy ratio of newly added domestic devices increased from 72.7%to 84.9%.The occupancy ratio of domestic devices of newly added key equipment increased from 63.0%to 83.4%,and the growth rate reached 20.4%.In different districts and different grades of medical institution,the increase and application of domestically medical devices appeared difference.Conclusion:The occupancy rate of newly added domestically medical devices in 9 demonstration regions in Liaoning province has generally increased.However,there are still imbalances between different regions and different grades of medical institutions.The manufacturers of domestically medical devices still need strengthen brand building and marketing promotion,so as to further enhance market competitiveness of domestically medical devices.

Result Analysis
Print
Save
E-mail