1.Analysis of diagnosis and treatment of Epstein-Barr virus-negative diffuse large B-cell lymphoma (GCB type) after kidney transplantation
Yan LI ; Xiaoyan ZHANG ; Xiang REN ; Tong XU ; Guohui WANG ; Ruochen QI ; Dongjuan WU ; Kepu LIU ; Weijun QIN ; Shuaijun MA
Organ Transplantation 2026;17(2):257-265
Objective To analyze the clinical and therapeutic characteristics of Epstein-Barr virus (EBV)-negative posttransplant lymphoproliferative disease (PTLD) with diffuse large B-cell lymphoma (DLBCL) in the context of specific cases and literature. Methods A case of EBV-negative DLBCL (GCB type) after kidney transplantation is reported. The patient was a 45-year-old male who underwent living-related kidney transplantation in 2016 and has been receiving triple immunosuppressive therapy with tacrolimus, mycophenolate mofetil and methylprednisolone since then. In 2024, the patient presented with intermittent fever, night sweats and gastrointestinal symptoms. The diagnosis was confirmed by endoscopic pathology, immunohistochemical staining and positron emission tomography/computed tomography. The R-CDOP regimen (rituximab + cyclophosphamide + liposomal doxorubicin + vincristine + dexamethasone) was used for treatment. Results The patient was diagnosed with EBV-negative DLBCL (GCB type, Ann Arbor stage Ⅳ B). After 4 cycles of R-CDOP chemotherapy, the efficacy assessment was partial remission, and the transplant kidney function remained stable. Conclusions For EBV-negative PTLD after kidney transplantation, it is necessary to break through the "virus-dependent" diagnostic thinking. In clinical practice, the focus should be on protecting the transplant kidney, and individualized treatment plans should be developed for patients.
2.Report of 4 cases of IgG4-related urinary diseases and literature review
Fanchao WEI ; Zhaoxiang WANG ; Mengwei XU ; Ruochen QI ; Guohui WANG ; Xiaoyan ZHANG ; Tong XU ; Jingliang ZHANG ; Shuaijun MA ; Weijun QIN ; Lijun YANG ; Shichao HAN
Journal of Modern Urology 2025;30(1):59-63
[Objective] To explore the clinical features of IgG4-related urinary diseases so as to provide reference for the diagnosis and treatment of such diseases. [Methods] The clinical data of 4 cases of IgG4-related urinary system diseases diagnosed and treated in Xijing Hospital of Air Force Medical University during Aug.2019 and Dec.2023 were retrospectively collected.Here, we report on the diagnosis and treatment of these patients, analysing their symptoms, serology, imaging and pathology as well as their treatment and outcomes. [Results] The patients included 2 male and 2 female.The lesions were involved with the retroperitoneum and urinary system.Three patients had symptoms of lumbar pain.The imaging manifestations were complex, including retroperitoneal mass involving urinary system organs in 2 cases, tabdense shadow of the right kidney in 1 case, and simple cystic mass of kidney in 1 case.Serum IgG4 value was not detected before surgery.All patients underwent radical surgical treatment.Postoperative pathology showed fibrous tissue hyperplasia with a large number of plasma cells, lymphocytes, a few neutrophil infiltrates, and lymphoid follicles and obliterated vasculitis in some specimens.The number of IgG4+ plasma cells was more than 10 in all tissues under high power microscope.After surgery, 3 patients had symptoms improved, and serum IgG4 value was within the normal range; 1 patient (patem 3) had elevated IgG4 value during follow-up, received subsequent hormone therapy, and the serum IgG 4 level remained stable. [Conclusion] The symptoms of IgG4-related diseases involving the urinary system are non-specific, and the imaging findings are various, easily confused with other diseases.Early detection of serum IgG4 and biopsy pathology can help clinicians make correct diagnosis in the early stage.
3.Microcirculatory Dysfunction After Percutaneous Coronary Intervention Predicts the Early Prognosis of Patients With ST-segment Elevation Myocardial Infarction
Guohui CHEN ; Yuxuan ZHANG ; Abuduwufuer YIDILISI ; Yiyue ZHENG ; Delong CHEN ; Jiacheng FANG ; Zining CHEN ; Rui JI ; Jiamu CHEN ; Tiesheng NIU ; Jun PU ; Jian'an WANG ; Jun JIANG
Chinese Circulation Journal 2025;40(9):892-897
Objectives:To explore the predictive value of angiography-derived index of microcirculatory resistance(Angio-IMR)for early prognosis in patients with acute ST-segment elevation myocardial infarction(STEMI)after percutaneous coronary intervention(PCI).Methods:This multicenter study enrolled 1 629 consecutive STEMI patients who underwent successful PCI at three grade A tertiary hospitals(The Second Affiliated Hospital,Zhejiang University School of Medicine;Shengjing Hospital of China Medical University;Renji Hospital,Shanghai Jiao Tong University School of Medicine)from June 1,2017,to May 31,2020.According to postoperative Angio-IMR,patients was stratified into two groups:the Angio-IMR>40 group(n=508)and the Angio-IMR≤40 group(n=1 121).The incidence of major adverse cardiovascular events(MACE;defined as a composite endpoint including cardiac death,heart failure rehospitalization,cardiogenic shock,malignant arrhythmia,cardiopulmonary resuscitation and stent thrombosis)within 1-month post-PCI was compared between the two groups.Results:The median Angio-IMR after PCI was 32.4(22.3,42.6).The cumulative incidence of early-term MACE was significantly higher in patients with Angio-IMR>40,compared to those with Angio-IMR≤40(5.5%vs.2.3%,log-rank P<0.001).Multivariate Cox regression analysis showed that Angio-IMR>40 was an independent predictor of early-term MACE(HR=2.07,95%CI:1.20-3.58,P=0.009).The addition of Angio-IMR enhanced the predicting performance of the clinical risk model to predict early adverse outcomes(AUC:0.820 vs.0.794,P=0.043).Conclusions:In patients with STEMI after PCI,Angio-IMR can predict the occurrence of early-term MACE.The incorporation of Angio-IMR to clinical models significantly improves the model ability to predict early adverse outcomes in these patients.
4.Clinical Study on Acupoint Automatic Positioning Moxibustion Therapy Robot for Treatment of Lumbar Disc Herniation
Shuangyue LI ; Juntao YAN ; Fanfu FANG ; Yuxin ZHENG ; Chengbing CAO ; Yuan YUAN ; Feiran ZHAO ; Qing XU ; Xiaojie SU ; Guohui ZHANG
Chinese Journal of Information on Traditional Chinese Medicine 2025;32(5):154-161
Objective To investigate the clinical advantages and safety of an acupoint auto-positioning moxibustion robot combined with massage techniques in the treatment of lumbar disc herniation.Methods Totally 114 patients with lumbar disc herniation treated between June 2021 and December 2023 at Yueyang Hospital of Integrated Traditional Chinese and Western Medicine,Shanghai University of Traditional Chinese Medicine,the Outpatient Department of Rehabilitation Medicine,Changhai Hospital and Shanghai Third Rehabilitation Hospital were divided into control group and experimental group with random number table method,with 57 cases in each group.The control group received conventional moxibustion combined with massage techniques,while the experimental group was treated using an acupoint auto-positioning moxibustion robot combined with massage techniques.Both groups underwent treatment once every three days,totaling 10 sessions over one month.Clinical efficacy was observed between the two groups by comparing pre-treatment and post-treatment(after 3,6 and 10 sessions)scores on the visual analogue scale(VAS)for pain,the Japanese Orthopaedic Association(JOA)lower back pain score,and lumbar range of motion(LROM).Adverse reactions during the intervention were recorded.Satisfaction with the moxibustion robot in the experimental group was assessed using a Likert scale.Additionally,20 healthy subjects were recruited to evaluate the accuracy of the robot's acupoint auto-positioning function.Results The overall effective rate was 91.23%(52/57)in the experimental group and 94.74%(54/57)in the control group,without statistical significance between the two groups(P>0.05).Compared to pre-treatment,both groups showed significant improvements in VAS scores,JOA scores and LROM across all measured directions after 3,6,and 10 treatment sessions(P<0.001).In the Likert scale assessment,86.96%of subjects agreed that the device was convenient to use,87.72%agreed that the device was safer than conventional moxibustion therapy,and 94.74%were willing to recommend the device to other patients.The accuracy evaluation of the acupoint auto-positioning moxibustion robot demonstrated that the average deviation between robot-positioned acupoints and standard acupoints was(1.68±0.46)mm,achieving a positioning accuracy rate exceeding 95%.No adverse reactions were reported during the intervention.Conclusion The combination of an acupoint auto-positioning moxibustion robot with massage techniques is as effective as conventional moxibustion combined with massage techniques in improving clinical symptoms,alleviating pains,enhancing lumbar function and increasing lumbar mobility in patients with lumbar disc herniation.Participants have exhibited a high willingness to use the device,and the robot achieved a high accuracy rate in acupoint positioning.
5.Clinical Study on Acupoint Automatic Positioning Moxibustion Therapy Robot for Treatment of Lumbar Disc Herniation
Shuangyue LI ; Juntao YAN ; Fanfu FANG ; Yuxin ZHENG ; Chengbing CAO ; Yuan YUAN ; Feiran ZHAO ; Qing XU ; Xiaojie SU ; Guohui ZHANG
Chinese Journal of Information on Traditional Chinese Medicine 2025;32(5):154-161
Objective To investigate the clinical advantages and safety of an acupoint auto-positioning moxibustion robot combined with massage techniques in the treatment of lumbar disc herniation.Methods Totally 114 patients with lumbar disc herniation treated between June 2021 and December 2023 at Yueyang Hospital of Integrated Traditional Chinese and Western Medicine,Shanghai University of Traditional Chinese Medicine,the Outpatient Department of Rehabilitation Medicine,Changhai Hospital and Shanghai Third Rehabilitation Hospital were divided into control group and experimental group with random number table method,with 57 cases in each group.The control group received conventional moxibustion combined with massage techniques,while the experimental group was treated using an acupoint auto-positioning moxibustion robot combined with massage techniques.Both groups underwent treatment once every three days,totaling 10 sessions over one month.Clinical efficacy was observed between the two groups by comparing pre-treatment and post-treatment(after 3,6 and 10 sessions)scores on the visual analogue scale(VAS)for pain,the Japanese Orthopaedic Association(JOA)lower back pain score,and lumbar range of motion(LROM).Adverse reactions during the intervention were recorded.Satisfaction with the moxibustion robot in the experimental group was assessed using a Likert scale.Additionally,20 healthy subjects were recruited to evaluate the accuracy of the robot's acupoint auto-positioning function.Results The overall effective rate was 91.23%(52/57)in the experimental group and 94.74%(54/57)in the control group,without statistical significance between the two groups(P>0.05).Compared to pre-treatment,both groups showed significant improvements in VAS scores,JOA scores and LROM across all measured directions after 3,6,and 10 treatment sessions(P<0.001).In the Likert scale assessment,86.96%of subjects agreed that the device was convenient to use,87.72%agreed that the device was safer than conventional moxibustion therapy,and 94.74%were willing to recommend the device to other patients.The accuracy evaluation of the acupoint auto-positioning moxibustion robot demonstrated that the average deviation between robot-positioned acupoints and standard acupoints was(1.68±0.46)mm,achieving a positioning accuracy rate exceeding 95%.No adverse reactions were reported during the intervention.Conclusion The combination of an acupoint auto-positioning moxibustion robot with massage techniques is as effective as conventional moxibustion combined with massage techniques in improving clinical symptoms,alleviating pains,enhancing lumbar function and increasing lumbar mobility in patients with lumbar disc herniation.Participants have exhibited a high willingness to use the device,and the robot achieved a high accuracy rate in acupoint positioning.
6.The inhibitory impact of natural antibacterial biomaterials on Streptococcus mutans and its associated biofilm formation
Xingtao CHANG ; Jiaxin HU ; Jiangling SUN ; Jiqin ZHANG ; Xianrun CHEN ; Guohui BAI ; Yi LUO
STOMATOLOGY 2025;45(3):235-240
In recent years,natural antimicrobial biomaterials have received widespread attention due to their rich sources,broad anti-microbial spectrum,high antimicrobial activity,good biocompatibility,etc.They play an important role in caries prevention and treat-ment by inhibiting the formation of biofilm and removing the formed biofilm.In this paper,we summarize the inhibitory effects of differ-ent natural antimicrobial biomaterials on Streptococcus mutans,the main caries-causing organism,and its biofilm,with a view to provi-ding theoretical references for caries prevention and treatment.
7.Prenatal ultrasound for diagnosing fetal intracranial arachnoid cyst and predicting outcomes
Guohui ZHANG ; Lijuan SUN ; Cuixia GUO ; Yuanjie CUI
Chinese Journal of Medical Imaging Technology 2025;41(3):372-376
Objective To observe the value of prenatal ultrasound for diagnosing fetal intracranial arachnoid cyst(IAC)and predicting outcomes.Methods A total of 240 fetuses with IAC confirmed by fetal brain MR examination or clinical follow-up were retrospectively enrolled,and the prenatal ultrasonic manifestations were observed.The outcomes of pregnancy were recorded,and the neurological development and treatment after birth were regularly followed up,then the fetuses were classified into good outcome or poor outcome groups.Univariate and binary logistic regression were used to analyze clinical data and prenatal ultrasonic findings,and the impact factors of outcomes of fetal IAC were screened.Results Among 240 fetuses,IAC located in the supratentorial area in 192(192/240,80.00%)and in the infratentorial area in 48(48/240,20.00%)fetuses.The size of IAC was 0.3-6.2 cm,with an average of(1.4±0.9)cm.Single lesion was found in 230 fetuses(230/240,95.83%),while multiple lesions were detected in 10 fetuses(10/240,4.17%).IAC presented as thin-walled cystic echoes with clear intracranial boundaries and good intracapsular sound transmission in all 240 fetuses,including 150(150/240,62.50%)with simple IAC and 90(90/240,37.50%)complicated with intracranial or other system malformations.Totally 189 fetuses were delivered successfully,while 51 underwent induction of labor.The newborns were followed up to 6-84 months.Among 240 fetuses with IAC,171(171/240,71.25%)had good outcome and 69(69/240,28.75%)had poor outcome.The size,number of lesion and whether combined with malformations or not on prenatal ultrasound and gender were all independent impact factors of outcomes of fetal IAC(OR=1.558,6.323,0.911,2.662,all P<0.05).Conclusion Prenatal ultrasound could accurately diagnose and predict the outcomes of fetal IAC.
8.Microcirculatory Dysfunction After Percutaneous Coronary Intervention Predicts the Early Prognosis of Patients With ST-segment Elevation Myocardial Infarction
Guohui CHEN ; Yuxuan ZHANG ; Abuduwufuer YIDILISI ; Yiyue ZHENG ; Delong CHEN ; Jiacheng FANG ; Zining CHEN ; Rui JI ; Jiamu CHEN ; Tiesheng NIU ; Jun PU ; Jian'an WANG ; Jun JIANG
Chinese Circulation Journal 2025;40(9):892-897
Objectives:To explore the predictive value of angiography-derived index of microcirculatory resistance(Angio-IMR)for early prognosis in patients with acute ST-segment elevation myocardial infarction(STEMI)after percutaneous coronary intervention(PCI).Methods:This multicenter study enrolled 1 629 consecutive STEMI patients who underwent successful PCI at three grade A tertiary hospitals(The Second Affiliated Hospital,Zhejiang University School of Medicine;Shengjing Hospital of China Medical University;Renji Hospital,Shanghai Jiao Tong University School of Medicine)from June 1,2017,to May 31,2020.According to postoperative Angio-IMR,patients was stratified into two groups:the Angio-IMR>40 group(n=508)and the Angio-IMR≤40 group(n=1 121).The incidence of major adverse cardiovascular events(MACE;defined as a composite endpoint including cardiac death,heart failure rehospitalization,cardiogenic shock,malignant arrhythmia,cardiopulmonary resuscitation and stent thrombosis)within 1-month post-PCI was compared between the two groups.Results:The median Angio-IMR after PCI was 32.4(22.3,42.6).The cumulative incidence of early-term MACE was significantly higher in patients with Angio-IMR>40,compared to those with Angio-IMR≤40(5.5%vs.2.3%,log-rank P<0.001).Multivariate Cox regression analysis showed that Angio-IMR>40 was an independent predictor of early-term MACE(HR=2.07,95%CI:1.20-3.58,P=0.009).The addition of Angio-IMR enhanced the predicting performance of the clinical risk model to predict early adverse outcomes(AUC:0.820 vs.0.794,P=0.043).Conclusions:In patients with STEMI after PCI,Angio-IMR can predict the occurrence of early-term MACE.The incorporation of Angio-IMR to clinical models significantly improves the model ability to predict early adverse outcomes in these patients.
9.Association of the adipokine Chemerin with the development and progression of liver fibrosis
Xinyuan ZHANG ; Nuoqi ZHANG ; Guohui YU ; Wenshuai REN ; Yaling WANG
Journal of Clinical Hepatology 2025;41(1):164-169
Liver fibrosis is the common pathological process in the progression of various chronic liver diseases to liver cirrhosis, and it greatly affects the prognosis of patients with chronic liver diseases. As a novel adipokine, Chemerin participates in the metabolism of glucose and lipids and inflammation, and various studies have shown that the expression level of Chemerin is correlated with the degree of liver fibrosis, suggesting that Chemerin may be involved in the process of liver fibrosis by regulating metabolism and inflammation. Chemerin has shown certain potential in the auxiliary diagnosis of liver fibrosis and the intervention against the progression of liver fibrosis. This article reviews the potential role and mechanism of action of Chemerin in the process of liver fibrosis, in order to provide new ideas for the diagnosis and treatment of liver fibrosis.
10.Hypofractionated radiotherapy combined with transcatheter arterial chemoembolization for the treatment of metachronous hepatic oligometastasis from nasopharyngeal carcinoma:analysis of its clinical effect
Yecai HUANG ; Jie ZHOU ; Peng ZHANG ; Shun LU ; Jingyi LANG ; Guohui XU ; Xuegang YANG
Journal of Interventional Radiology 2025;34(9):992-996
Objective To explore the effectiveness and safety of hypofractionated radiotherapy(HFRT)combined with transcatheter arterial chemoembolization(TACE)for metachronous hepatic oligometastasis from nasopharyngeal carcinoma(NPC).Methods The clinical data of patients with metachronous hepatic oligometastasis from NPC,who received HFRT combined with TACE treatment at the Sichuan Provincial Cancer Hospital of China from January 2012 to October 2022,were retrospectively analyzed.The 3-year and 5-year overall survival(OS),progression-free survival(PFS),local recurrence-free survival(LRFS),no extrahepatic distant metastasis survival(EMFS),and treatment-related adverse reactions were analyzed.Results A total of 55 patients were enrolled in this study,including 36 males and 19 females,the median age at the time of occurring metachronous hepatic oligometastasis was 44(27-75)years.The 3-year and 5-year OS,PFS,LRFS,EMFS were 67.8%and 40.0%,55.8%and 30.0%,72.7%and 56.5%,63.6%and 56.5%,respectively.The subgroup analysis indicated that the treatment course of TACE ≥3 cycles could significantly improve the PFS of patients with oligometastasis.HFRT combined with TACE treatment was well tolerated by all patients,and the incidence of Grade Ⅲ-Ⅳadverse reactions was quite low.Conclusion For the treatment of metachronous hepatic oligometastasis from NPC,HFRT combined with TACE is clinically effective,besides,the patients can well tolerate the therapeutic scheme.

Result Analysis
Print
Save
E-mail