1.Unilateral biportal endoscopy assisted bilateral decompression in the treatment of lumbar disc herniation with imaging herniation on one side and clinical symptoms on the contralateral side
Weiliang SU ; Yongfeng DOU ; Dong LIU ; Guohua DAI ; Min ZHANG ; Jianqiang XING ; Dawei WANG ; Peng HU ; Xiaopeng GENG
Chinese Journal of Orthopaedics 2025;45(1):44-50
Objective:To observe the clinical efficacy of unilateral biportal endoscopy (UBE) assisted bilateral decompression in the treatment of lumbar disc herniation with imaging herniation on one side and clinical symptoms on the contralateral side.Methods:A total of 20 patients with lumbar disc herniation with imaging herniation on one side and clinical symptoms on the contralateral side treated with UBE from January 2022 to January 2024 in the Affiliated Hospital of Binzhou Medical University were retrospectively analyzed. There were 9 males and 11 females, aged 50.4±14.0 years (range, 23-72 years). The intervertebral disc herniation level included L 3-4 in 1 case, L 4-5 in 15 cases, and L 5S 1 in 4 cases. There were 10 cases on the left side and 10 cases on the right side. The duration of symptoms was 24.1±33.7 months (range, 1-120 months). Visual analogue scale (VAS) and Oswestry disability index (ODI) were used to evaluate postoperative pain relief and functional recovery. The clinical efficacy was evaluated by modified MacNab criteria at 6 months after operation. Results:All patients successfully completed the operation. The operation time was 90.3±24.6 min (range, 55-134 mins). The VAS scores of patients at 3 days, 1 month, 3 months and 6 months after operation were 3.6±0.9, 2.2±0.7, 1.2±0.5 and 1.0±0.6, respectively, which were lower than those before operation (6.4±0.8), and the differences were statistically significant ( F=668.728, P<0.001). The ODI at 3 days, 1 month, 3 months and 6 months after operation were 34.2%±4.7%, 28.7%±2.8%, 24.3%±2.1% and 20.5%±2.0%, respectively, which were lower than 69.4%±5.2% before operation, and the differences were statistically significant ( F=515.578, P<0.001). The clinical efficacy was evaluated by modified MacNab criteria at 6 months after operation. Among 20 patients, 18 cases were excellent, 1 case was good, and 1 case was fair. All patients were followed up for 9.1±2.1 months (range, 6-14 months). One patient had a dural tear during the operation, but the range was small and there was no defect, and no further treatment was performed. Numbness of the lower limbs occurred 1 day after operation, and the symptoms disappeared after symptomatic treatment. There was no recurrence of lower limb symptoms, lumbar instability, intervertebral space infection or other complications at the last follow-up. Conclusion:Bilateral decompression with UBE is effective in the treatment of lumbar disc herniation with imaging herniation on one side and clinical symptoms on the contralateral side, which can improve the lumbar pain and function of patients.
2.A Comparative Study of Digital 3D Technology Assisted Versus Traditional One-hole Split Endoscopic Surgery for Lumbar Spinal Stenosis With Degenerative Scoliosis
Weiliang SU ; Min ZHANG ; Guohua DAI ; Kuishuai XU ; Dawei WANG ; Xiaopeng GENG ; Dong LIU ; Yongfeng DOU
Chinese Journal of Minimally Invasive Surgery 2025;25(10):615-622
Objective To compare the clinical efficacy of digital 3D technology assisted and traditional one-hole split endoscopic surgery for lumbar spinal stenosis with degenerative scoliosis(LSS-DS).Methods Clinical data of 42 patients with LSS-DS who underwent one-hole split endoscopic surgery from January 2022 to December 2023 were retrospectively analyzed.Among them,20 cases were treated with digital 3D technology assisted one-hole split endoscopic surgery(3D group),and 22 cases were treated with traditional one-hole split endoscopic surgery(traditional group).The operation time,intraoperative blood loss,lateral articular surface preservation rate,Visual Analogue Scale(VAS)of lower extremity pain,Oswestry Disability Index(ODI)and modified MacNab criteria at the last follow-up were compared between the two groups.Results Both groups of patients were operated successfully.The operation time of the 3D group and the traditional group was(73.3±24.0)min and(65.7±23.8)min,respectively,with no significant difference(t=1.020,P=0.314).The intraoperative blood loss was(65.3±14.7)ml and(66.7±17.1)ml,respectively,with no significant difference(t=-0.298,P=0.767).The retention rate of lateral articular surface in the 3D group[(88.2±6.3)%]was significantly higher than that in the traditional group[(82.7±4.6)%,t=3.201,P=0.003].One patient in the traditional group had dural tear and was cured after conservative treatment.There were 3 cases of calf muscle venous thrombosis in the 3D group and 4 cases in the traditional group.All the 7 patients were given anticoagulant therapy and appropriately delayed time of ambulation.In the3D group,20 cases were followed up for6-13 months,with a mean of(8.2±2.0)months;in the traditional group,22 cases were followed up for 6-12 months,with a mean of(7.7±1.7)months.According to the modified MacNab criteria,the excellent and good rate was 95.0%(19/20)in the 3D group and 90.1%(20/22)in the traditional group at the last follow-up,and there was no significant difference between the two groups(Z=-0.311,P=0.756).The VAS score and ODI of the two groups were significantly improved at 3 months and 6 months after operation(all P=0.000),but there was no significant difference between the two groups at each time point(P>0.05).Conclusion The short-term efficacy of digital 3D technology assisted one-hole split endoscopic surgery in the treatment of LSS-DS is definite,and the symptoms of patients are significantly improved.
3.Chinese interpretation of PROBAST+AI: An updated quality, risk of bias, and applicability assessment tool for prediction models using regression or artificial intelligence methods
Xingmeng WANG ; Guohua DAI ; Wulin GAO ; Hui GUAN ; Lili REN ; Chen CHEN ; Xiaoyang TAN ; Yiming LIN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(12):1686-1695
The development and validation of clinical prediction models based on artificial intelligence (AI) and machine learning methods have become increasingly widespread. However, the prediction model bias risk and applicability evaluation tool developed in 2019 (i.e., PROBAST-2019) has shown significant limitations. Therefore, an expanded and updated version of the PROBAST-2019 tool was released in 2025, known as the PROBAST+AI tool. The tool is divided into two parts including model development and model evaluation. It aims to comprehensively and systematically evaluate potential methodological quality issues in model development, bias risks in model evaluation, and the applicability of models, regardless of the modeling method used. This paper provides a systematic interpretation of the PROBAST+AI tool's items and case analyses, with the aim of guiding and assisting researchers engaged in related studies and promoting the high-quality development of clinical predictive model research.
4.A Comparative Study of Digital 3D Technology Assisted Versus Traditional One-hole Split Endoscopic Surgery for Lumbar Spinal Stenosis With Degenerative Scoliosis
Weiliang SU ; Min ZHANG ; Guohua DAI ; Kuishuai XU ; Dawei WANG ; Xiaopeng GENG ; Dong LIU ; Yongfeng DOU
Chinese Journal of Minimally Invasive Surgery 2025;25(10):615-622
Objective To compare the clinical efficacy of digital 3D technology assisted and traditional one-hole split endoscopic surgery for lumbar spinal stenosis with degenerative scoliosis(LSS-DS).Methods Clinical data of 42 patients with LSS-DS who underwent one-hole split endoscopic surgery from January 2022 to December 2023 were retrospectively analyzed.Among them,20 cases were treated with digital 3D technology assisted one-hole split endoscopic surgery(3D group),and 22 cases were treated with traditional one-hole split endoscopic surgery(traditional group).The operation time,intraoperative blood loss,lateral articular surface preservation rate,Visual Analogue Scale(VAS)of lower extremity pain,Oswestry Disability Index(ODI)and modified MacNab criteria at the last follow-up were compared between the two groups.Results Both groups of patients were operated successfully.The operation time of the 3D group and the traditional group was(73.3±24.0)min and(65.7±23.8)min,respectively,with no significant difference(t=1.020,P=0.314).The intraoperative blood loss was(65.3±14.7)ml and(66.7±17.1)ml,respectively,with no significant difference(t=-0.298,P=0.767).The retention rate of lateral articular surface in the 3D group[(88.2±6.3)%]was significantly higher than that in the traditional group[(82.7±4.6)%,t=3.201,P=0.003].One patient in the traditional group had dural tear and was cured after conservative treatment.There were 3 cases of calf muscle venous thrombosis in the 3D group and 4 cases in the traditional group.All the 7 patients were given anticoagulant therapy and appropriately delayed time of ambulation.In the3D group,20 cases were followed up for6-13 months,with a mean of(8.2±2.0)months;in the traditional group,22 cases were followed up for 6-12 months,with a mean of(7.7±1.7)months.According to the modified MacNab criteria,the excellent and good rate was 95.0%(19/20)in the 3D group and 90.1%(20/22)in the traditional group at the last follow-up,and there was no significant difference between the two groups(Z=-0.311,P=0.756).The VAS score and ODI of the two groups were significantly improved at 3 months and 6 months after operation(all P=0.000),but there was no significant difference between the two groups at each time point(P>0.05).Conclusion The short-term efficacy of digital 3D technology assisted one-hole split endoscopic surgery in the treatment of LSS-DS is definite,and the symptoms of patients are significantly improved.
5.Unilateral biportal endoscopy assisted bilateral decompression in the treatment of lumbar disc herniation with imaging herniation on one side and clinical symptoms on the contralateral side
Weiliang SU ; Yongfeng DOU ; Dong LIU ; Guohua DAI ; Min ZHANG ; Jianqiang XING ; Dawei WANG ; Peng HU ; Xiaopeng GENG
Chinese Journal of Orthopaedics 2025;45(1):44-50
Objective:To observe the clinical efficacy of unilateral biportal endoscopy (UBE) assisted bilateral decompression in the treatment of lumbar disc herniation with imaging herniation on one side and clinical symptoms on the contralateral side.Methods:A total of 20 patients with lumbar disc herniation with imaging herniation on one side and clinical symptoms on the contralateral side treated with UBE from January 2022 to January 2024 in the Affiliated Hospital of Binzhou Medical University were retrospectively analyzed. There were 9 males and 11 females, aged 50.4±14.0 years (range, 23-72 years). The intervertebral disc herniation level included L 3-4 in 1 case, L 4-5 in 15 cases, and L 5S 1 in 4 cases. There were 10 cases on the left side and 10 cases on the right side. The duration of symptoms was 24.1±33.7 months (range, 1-120 months). Visual analogue scale (VAS) and Oswestry disability index (ODI) were used to evaluate postoperative pain relief and functional recovery. The clinical efficacy was evaluated by modified MacNab criteria at 6 months after operation. Results:All patients successfully completed the operation. The operation time was 90.3±24.6 min (range, 55-134 mins). The VAS scores of patients at 3 days, 1 month, 3 months and 6 months after operation were 3.6±0.9, 2.2±0.7, 1.2±0.5 and 1.0±0.6, respectively, which were lower than those before operation (6.4±0.8), and the differences were statistically significant ( F=668.728, P<0.001). The ODI at 3 days, 1 month, 3 months and 6 months after operation were 34.2%±4.7%, 28.7%±2.8%, 24.3%±2.1% and 20.5%±2.0%, respectively, which were lower than 69.4%±5.2% before operation, and the differences were statistically significant ( F=515.578, P<0.001). The clinical efficacy was evaluated by modified MacNab criteria at 6 months after operation. Among 20 patients, 18 cases were excellent, 1 case was good, and 1 case was fair. All patients were followed up for 9.1±2.1 months (range, 6-14 months). One patient had a dural tear during the operation, but the range was small and there was no defect, and no further treatment was performed. Numbness of the lower limbs occurred 1 day after operation, and the symptoms disappeared after symptomatic treatment. There was no recurrence of lower limb symptoms, lumbar instability, intervertebral space infection or other complications at the last follow-up. Conclusion:Bilateral decompression with UBE is effective in the treatment of lumbar disc herniation with imaging herniation on one side and clinical symptoms on the contralateral side, which can improve the lumbar pain and function of patients.
6.Re-admission risk prediction models for patients with heart failure after discharge: A systematic review
Ruilei GAO ; Dan WANG ; Guohua DAI ; Wulin GAO ; Hui GUAN ; Xueyan DONG
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(05):677-684
Objective To systematically evaluate the predictive models for re-admission in patients with heart failure (HF) in China. Methods Studies related to the risk prediction model for HF patient re-admission published in The Cochrane Library, PubMed, EMbase, CNKI, and other databases were searched from their inception to April 30, 2024. The prediction model risk of bias assessment tool was used to assess the risk of bias and applicability of the included literature, relevant data were extracted to evaluate the model quality. Results Nineteen studies were included, involving a total of 38 predictive models for HF patient re-admission. Comorbidities such as diabetes, N-terminal pro B-type natriuretic peptide/brain natriuretic peptide, chronic renal insufficiency, left ventricular ejection fraction, New York Heart Association cardiac function classification, and medication adherence were identified as primary predictors. The area under the receiver operating characteristic curve ranged from 0.547 to 0.962. Thirteen studies conducted internal validation, one study conducted external validation, and five studies performed both internal and external validation. Seventeen studies evaluated model calibration, while five studies assessed clinical feasibility. The presentation of the models was primarily in the form of nomograms. All studies had a high overall risk of bias. Conclusion Most predictive models for HF patient re-admission in China demonstrate good discrimination and calibration. However, the overall research quality is suboptimal. There is a need to externally validate and calibrate existing models and develop more stable and clinically applicable predictive models to assess the risk of HF patient re-admission and identify relevant patients for early intervention.
7.Dual-low dose protocol combined with iterative model reconstruction in CT angiography of ophthalmic artery
Qi GUO ; Xuening ZHANG ; Guohua FAN ; Dai SHI
Chinese Journal of Interventional Imaging and Therapy 2025;22(6):409-412
Objective To observe the value of dual-low dose protocol(low tube voltage and low contrast agents)combined with iterative model reconstruction(IMR)in CT angiography(CTA)of ophthalmic artery.Methods Totally 100 patients who underwent head and neck CTA were retrospectively enrolled and divided into observation group(n=50,dual-low dose protocol+IMR)and control group(n=50,conventional protocol+filtered back projection[FBP]).Subjective and objective evaluations on image quality were performed,radiation doses and dosage of contrast agents were calculated,and the outcomes were compared between groups.Results Signal-to-noise ratio(SNR)and contrast-to-noise ratio(CNR)of ophthalmic artery on CTA were both higher(both P<0.001),while noise(SD)of optic nerve,volume CT dose index(CTDIvol),dose-length product(DLP)and effective dose(ED)in observation group were all lower than those in control group(all P<0.001).No significant difference of subjective scoring of image quality,CT values of ophthalmic artery nor optic nerve was found between groups(all P>0.05).Compared with control group,CTDIvol,DLP,ED,iodine dosage and iodine flow rate in observation group decreased by 69.85%,70.17%,70.28%,43.24%and 43.24%,respectively.Conclusion Dual-low dose protocol combined with IMR could reduce radiation dose and contrast agents dosage in CTA of ophthalmic artery under the condition of ensuring image quality.
8.Dual-low dose protocol combined with iterative model reconstruction in CT angiography of ophthalmic artery
Qi GUO ; Xuening ZHANG ; Guohua FAN ; Dai SHI
Chinese Journal of Interventional Imaging and Therapy 2025;22(6):409-412
Objective To observe the value of dual-low dose protocol(low tube voltage and low contrast agents)combined with iterative model reconstruction(IMR)in CT angiography(CTA)of ophthalmic artery.Methods Totally 100 patients who underwent head and neck CTA were retrospectively enrolled and divided into observation group(n=50,dual-low dose protocol+IMR)and control group(n=50,conventional protocol+filtered back projection[FBP]).Subjective and objective evaluations on image quality were performed,radiation doses and dosage of contrast agents were calculated,and the outcomes were compared between groups.Results Signal-to-noise ratio(SNR)and contrast-to-noise ratio(CNR)of ophthalmic artery on CTA were both higher(both P<0.001),while noise(SD)of optic nerve,volume CT dose index(CTDIvol),dose-length product(DLP)and effective dose(ED)in observation group were all lower than those in control group(all P<0.001).No significant difference of subjective scoring of image quality,CT values of ophthalmic artery nor optic nerve was found between groups(all P>0.05).Compared with control group,CTDIvol,DLP,ED,iodine dosage and iodine flow rate in observation group decreased by 69.85%,70.17%,70.28%,43.24%and 43.24%,respectively.Conclusion Dual-low dose protocol combined with IMR could reduce radiation dose and contrast agents dosage in CTA of ophthalmic artery under the condition of ensuring image quality.
9.Construction and Application of Clinical Experience Knowledge Graph for Renowned TCM Doctors in Treating Coronary Heart Disease
Qun WANG ; Guohua DAI ; Hui GUAN ; Wulin GAO
Chinese Journal of Information on Traditional Chinese Medicine 2024;31(3):64-70
Objective To build a knowledge graph;To visualize the knowledge structure relationships and clinical thinking in the treatment of coronary heart disease by renowned TCM doctors;To provide methodological reference for the inheritance of experience of renowned TCM doctors.Methods Medical records about treatment of coronary heart disease by renowned TCM doctors were retrieved from CNKI from the establishment of the database to 30th,Nov.2022.The characteristics of TCM diagnosis and treatment and the characteristics of the theoretical system of syndrome differentiation and treatment in TCM were analyzed.Concept types and relationships between concepts were sorted out and extracted to form a pattern layer of knowledge graph;based on the characteristics of the pattern layer,Python 3.11(PyCharm 2022.3.2)was used to write rules,and knowledge extraction and data import were implemented through the Pandas library,Openpyxl library and Py2neo library,which were stored in the graph database Neo4j-Community-5.2.0 to complete the construction of the knowledge graph.Implementing query application was realized through Cypher language.Results The data of 643 medical cases of 144 renowned TCM doctors were included,which were entered into the Neo4j graph database,forming a knowledge graph consisting of 2 744 nodes and 23 795 relationships under 8 concepts and 10 relationships,to achieve visual presentation and query application of the diagnosis and treatment process of coronary heart disease by renowned TCM doctors.Conclusion The knowledge graph can intuitively display the relationship of diseases-symptoms-syndromes-treatments-prescriptions-medicine in medical records,develop a knowledge system that is easy to retrieve,and improve the accessibility of domain knowledge,which can provide methodological reference for the inheritance of experience of renowned TCM doctors.
10.Effect of finite element simulation of bilateral lumbar spinal canal decompression under single-channel splintered endoscope on lumbar biomechanics
Jinghe ZHANG ; Yongfeng DOU ; Shidong XU ; Jianqiang XING ; Dong LIU ; Lin TIAN ; Guohua DAI
Chinese Journal of Tissue Engineering Research 2024;28(12):1849-1854
BACKGROUND:As a leading technique in the treatment of primary stenosis by posterior spinal endoscopy through unilateral approach and bilateral decompression using single channel endoscopy,the long-term efficacy needs to be further observed.There are few reports on the scope of intraoperative resection and few relevant studies on biomechanics and finite element analysis. OBJECTIVE:A three-dimensional finite element model was established to evaluate the effects of bilateral lumbar canal decompression under a one-hole split endoscope on lumbar range of motion and intradiscal pressure,to provide suggestions for clinical operation and theoretical basis for further clinical research. METHODS:A complete L3-L5 vertebral body model was reconstructed by CT images of nine healthy volunteers,which was used as the preoperative model M1.The simulated surgical resection range of L4-L5 was performed,and 1/4,1/3 and 1/2 of bilateral facet joints were removed respectively to obtain models M2,M3 and M4.The range of motion and the maximum Von Mises stress of the four models were compared in the six directions of forward bending,backward extension,left and right bending,and left and right rotation. RESULTS AND CONCLUSION:(1)The L3-L5 finite element model established in this study was effective,and the range of motion was within the range of previous solid studies under six motion states.(2)Compared with the M1 model,the L4-L5 lumbar spine range of motion increased with the increase of resection range in M2 with M3 and M4 models under forward bending,left and right bending and left and right rotation loading,and the difference was significant(P<0.05).Under posterior extension loading,there was no significant difference in lumbar range of motion between M1 and M2(P>0.05),but there was a significant difference of M1,M3 and M4(P<0.05).(3)The range of motion of the L3-L4 lumbar spine had no significant change with the increase of bilateral facet arthrotomy(P>0.05).(4)There was a significant difference in the maximum value of L4-L5 Von Mises between M1 and M2(P<0.05),and there was a significant difference in the maximum value of L4-L5 Von Mises between M1 and M3,M4(P<0.01),and the maximum value of L4-L5 lumbar von Mises increased with the increasing range of bilateral facet joint resection.Resection of more than 1/3 was particularly obvious.(5)The maximum value of Von Mises in the L3-L4 lumbar spine was increased with the increase of the resection range under forward bending,left and right bending and left and right rotation loading and the difference was significant(P<0.05).(6)The results exhibited that the L4-L5 lumbar motion and intervertebral disc pressure increased with the increase of the excision range.Intervertebral disc pressure at L3-L4 increased with the increased extent of excision,but the lumbar range of motion was not significantly affected.In conclusion,the stability of the operative segment may be affected by the increase in the scope of facet joint resection.Although the immediate stability of adjacent segments is not affected,it may accelerate disc degeneration.

Result Analysis
Print
Save
E-mail