1.Expert Consensus on Clinical Application of Qinbaohong Zhike Oral Liquid in Treatment of Acute Bronchitis and Acute Attack of Chronic Bronchitis
Jian LIU ; Hongchun ZHANG ; Chengxiang WANG ; Hongsheng CUI ; Xia CUI ; Shunan ZHANG ; Daowen YANG ; Cuiling FENG ; Yubo GUO ; Zengtao SUN ; Huiyong ZHANG ; Guangxi LI ; Qing MIAO ; Sumei WANG ; Liqing SHI ; Hongjun YANG ; Ting LIU ; Fangbo ZHANG ; Sheng CHEN ; Wei CHEN ; Hai WANG ; Lin LIN ; Nini QU ; Lei WU ; Dengshan WU ; Yafeng LIU ; Wenyan ZHANG ; Yueying ZHANG ; Yongfen FAN
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(4):182-188
The Expert Consensus on Clinical Application of Qinbaohong Zhike Oral Liquid in Treatment of Acute Bronchitis and Acute Attack of Chronic Bronchitis (GS/CACM 337-2023) was released by the China Association of Chinese Medicine on December 13th, 2023. This expert consensus was developed by experts in methodology, pharmacy, and Chinese medicine in strict accordance with the development requirements of the China Association of Chinese Medicine (CACM) and based on the latest medical evidence and the clinical medication experience of well-known experts in the fields of respiratory medicine (pulmonary diseases) and pediatrics. This expert consensus defines the application of Qinbaohong Zhike oral liquid in the treatment of cough and excessive sputum caused by phlegm-heat obstructing lung, acute bronchitis, and acute attack of chronic bronchitis from the aspects of applicable populations, efficacy evaluation, usage, dosage, drug combination, and safety. It is expected to guide the rational drug use in medical and health institutions, give full play to the unique value of Qinbaohong Zhike oral liquid, and vigorously promote the inheritance and innovation of Chinese patent medicines.
2.Study on chemical constituents of Rhododendri Mollis Flos.
Peng-Yu GUO ; Yang SONG ; Hai-Qiang WANG ; Shi-Shan YU
China Journal of Chinese Materia Medica 2025;50(14):3938-3943
This study investigated the chemical constituents of Rhododendri Mollis Flos. The n-butanol fraction of 95% ethanol extract of Rhododendri Mollis Flos was separated and purified using chromatographic techniques, including normal-phase silica gel, ODS, and Sephadex LH-20 column chromatography. The structures of the isolated compounds were identified by spectroscopic techniques. Seven compounds were isolated and identified as rhodomollein LXⅦ(1), rhodomollein X(2), nivalenol(3),(3S,6S)-cis-linalool-3,7-oxide-β-D-glucopyranoside(4), thymidine(5), cyclo(Ala-Tyr)(6), and(S)-5-hydroxypyrrolidin-2-one(7). Among them, compound 1 was identified as a new compound, and compound 3 was isolated from this plant for the first time. The analgesic activity of compound 1 was evaluated using the acetic acid-induced writhing test. At a dose of 5.0 mg·kg~(-1), compound 1 showed a 75.4% inhibition rate in the writhing test, indicating significant analgesic activity.
Drugs, Chinese Herbal/isolation & purification*
;
Rhododendron/chemistry*
;
Animals
;
Flowers/chemistry*
;
Mice
;
Male
;
Analgesics/isolation & purification*
;
Molecular Structure
3.Clinical effects of single Kirschner wire assisted reduction in children with Gartland type Ⅲ supracondylar humerus fractures.
Yong HE ; Wei-Ping LI ; Zhi-Long CHEN ; Guo-Peng JIANG ; Shi-Hai CHEN ; Jun ZHAO ; Hua-Ming WANG ; Chen ZHANG
China Journal of Orthopaedics and Traumatology 2025;38(10):1071-1075
OBJECTIVE:
To investigate the clinical efficacy and safety of single Kirschner wire assisted poking and closed reduction in the treatment of Gartland type Ⅲ supracondylar humeral fractures in children.
METHODS:
A retrospective analysis was performed on patients diagnosed with Gravland type Ⅲ supracondylar humeral fractures between January 2022 and June 2023. A total of 46 patients were treated with closed reduction assisted by Kirschner wires and percutaneous Kirschner wire internal fixation.There were 25 males and 21 females. The age ranged from 5 to 10 years old, with an average of (5.8±1.8) years old. The left side was involved in 28 patients and the right side in 18 patients. Record the operative duration for patients, the number of fluoroscopic exposures, fracture healing time, postoperative carrying angle, Baumann angle, elbow joint function score at three months post-operation, and any associated complications.
RESULTS:
All 46 patients were followed up for a period of 12 to 16 weeks, with an average of (13.74±1.44 )weeks. The operation duration was (30.7±5.1) minutes, the fluoroscopy count was (10.2±2.7) times, the postoperative carrying angle of the elbow joint was (8.7±2.2) degrees, and the Baumann angle was (71.5±2.9) degrees. All fractures achieved successful union in all patients, with a mean healing time of (25.5±1.7) days.At the final follow-up, elbow joint function was assessed using the Flynn criteria, with 43 patients rated as excellent and 3 patients rated as good. No complications were observed, including cubitus varus, nerve injury, or local infection.
CONCLUSION
The use of a single Kirschner wire assisted prying reduction for treating Gartland type Ⅲ supracondylar humeral fractures in children demonstrates excellent clinical efficacy and safety.
Humans
;
Male
;
Female
;
Child
;
Bone Wires
;
Child, Preschool
;
Humeral Fractures/physiopathology*
;
Retrospective Studies
;
Fracture Fixation, Internal/instrumentation*
;
Treatment Outcome
;
Fracture Healing
4.Application of genome tagging technology in elucidating the function of sperm-specific protein 411 (Ssp411).
Xue-Hai ZHOU ; Min-Min HUA ; Jia-Nan TANG ; Bang-Guo WU ; Xue-Mei WANG ; Chang-Gen SHI ; Yang YANG ; Jun WU ; Bin WU ; Bao-Li ZHANG ; Yi-Si SUN ; Tian-Cheng ZHANG ; Hui-Juan SHI
Asian Journal of Andrology 2025;27(1):120-128
The genome tagging project (GTP) plays a pivotal role in addressing a critical gap in the understanding of protein functions. Within this framework, we successfully generated a human influenza hemagglutinin-tagged sperm-specific protein 411 (HA-tagged Ssp411) mouse model. This model is instrumental in probing the expression and function of Ssp411. Our research revealed that Ssp411 is expressed in the round spermatids, elongating spermatids, elongated spermatids, and epididymal spermatozoa. The comprehensive examination of the distribution of Ssp411 in these germ cells offers new perspectives on its involvement in spermiogenesis. Nevertheless, rigorous further inquiry is imperative to elucidate the precise mechanistic underpinnings of these functions. Ssp411 is not detectable in metaphase II (MII) oocytes, zygotes, or 2-cell stage embryos, highlighting its intricate role in early embryonic development. These findings not only advance our understanding of the role of Ssp411 in reproductive physiology but also significantly contribute to the overarching goals of the GTP, fostering groundbreaking advancements in the fields of spermiogenesis and reproductive biology.
Animals
;
Female
;
Humans
;
Male
;
Mice
;
Spermatids/metabolism*
;
Spermatogenesis/physiology*
;
Spermatozoa/metabolism*
;
Thioredoxins/genetics*
5.The impact of different contrast agent concentrations on excimer laser ablation:an in vitro study
Pan HE ; Yang SHI ; Hai-Wei CHEN ; Jun-Jie YANG ; Jun GUO ; Yun-Dai CHEN ; Qi WANG
Chinese Journal of Interventional Cardiology 2024;32(1):39-44
Objective To explore the impact of contrast agent concentration on the excimer laser's effect on plaque ablation.Methods Using a laser catheter with a diameter of 0.9 mm,we conducted plaque model ablation experiments employing a 308-nanometer xenon chloride excimer laser.During the excimer laser ablation process,five groups were formed based on the injected contrast agent concentrations:a saline group,25%concentration group,50%concentration group,75%concentration group,and 100%concentration group.Optical coherence tomography was utilized to assess the changes in plaque lumen area after excimer laser ablation,evaluating the impact of contrast agent concentration on the excimer laser's ablation efficacy.Simultaneously,a water manometer was used to measure the shockwave pressure generated by the excimer laser in liquids with different contrast agent concentrations,aiming to explore the correlation between the shockwave pressure of the excimer laser and its ablative effect.Results The ablation areas in the 75%concentration group and the 100%concentration group were similar(P>0.05),both exceeding those in the 50%concentration contrast agent group,25%concentration group,and saline group(all P<0.001).Specifically,the ablation area in the 50%concentration group was significantly larger than that in the 25%concentration group and saline group(both P<0.001),while the 25%concentration group was larger than the saline group(P<0.001).The influence of contrast agent concentration on the shockwave pressure of the excimer laser exhibited a similar trend.Additionally,there was a significant positive correlation between the shockwave pressure generated by the excimer laser and its ablation area(r=0.9987,P<0.001).Conclusions The intensity of excimer laser ablation on plaque tissue can be modulated by altering the contrast agent concentration.These findings offer guidance for the application of excimer laser in conjunction with contrast agent injection techniques in the treatment of coronary artery disease.
6.Electro-acupuncture for Vascular Cognitive Impairment:A Visualized Data Mining Analysis
Hai-Zhen GUO ; Han WU ; Mei-Kang YAO ; Jiang-Wei SHI ; Tao YU
Journal of Guangzhou University of Traditional Chinese Medicine 2024;41(1):161-168
Objective To summarize the acupoints and parameters commonly used in the treatment of vascular cognitive impairment(VCI)by electro-acupuncture(EA)through the visual data mining technique to provide a reference basis for clinical treatment.Methods The clinical studies of EA on the treatment of VCI were searched in CNKI,Wanfang,VIP,CBM,PubMed,Embase,Cochrane Library,web of science and other major databases.The literature is managed by Note Express and the database is established by Excel.The frequency of selected acupoints,frequency,meridian tropism,parameter frequency and frequency of used acupoints are counted.Factor analysis is carried out by SPSS 21.0 software.SPSS Modeler 18.3 software is used to analyze association rules and co-occurrence network,and the analysis results are visualized by Cytoscape 3.9.1 software.Results Finally,155 papers were included,containing 155 acupoint prescriptions and 157 parameter prescriptions.Acupoint prescriptions involved 100 acupoints with a total frequency of 856 times;parameter prescriptions involved 33 parameters with a total frequency of 788 times.Conclusion At present,there is a big difference between the clinical studies,and there is no recognized acupoint and parameter for EA treatment of VCI.By further summarizing the law of EA acupuncture point and parameter,the study has sorted out the law of commonly used acupoints,meridian tropism,compounding and parameter selection for EA treatment of VCI.It was concluded that the selection of acupoints mainly started from the three aspects of deficiency,phlegm and stasis,focusing on the combination of local and distal selection of acupoints,through the identification of internal organs and meridians,to achieve the simultaneous regulation of the heart,spleen and kidney,and to take into account both the symptoms and the root cause,and to play the roles of opening the orifices to wake up mind,calming mind and benefiting intellect,strengthening the spleen and tonifying the kidneys,and invigorating blood circulation to remove stasis.The parameters of EA are recommended to be sparse and dense wave,low frequency,as tolerated by the patient,30 minutes/times,1 time/day,5 times/week as the main combinations,which can provide a certain reference basis for clinical decision-making.
7.Evaluation of short-term effects on 3D printing patient-matched artificial vertebral body in clinical research and application
Xiaokang LI ; Lei SHI ; Xiangdong LI ; Hai HUANG ; Qi WU ; Xiaodong TANG ; Zheng GUO
Chinese Journal of Orthopaedics 2024;44(6):354-361
Objective:To evaluate the short-term efficacy and safety of 3D printing patient-matched artificial vertebral body in clinical research and application.Methods:A total of 12 patients with spinal tumors were enrolled 7 males (58.33%) and 5 females (41.67%), aged from 18 to 65 years old in The First Affiliated Hospital of Air Force military Medical University (hereinafter referred to as Xijing Hospital) and Peking University people's Hospital from September 2021 to July 2022. The spinal vertebra defect were restored by using 3D printing patient-matched artificial vertebral body after tumor resection. All patients who accepted TES and 3D printing patient-matched artificial vertebral body implantation were included according to the inclusion and exclusion criteria. The bone interface fusion was evaluated by the imaging fusion criteria of Brantigan and Steffee at 3 and 6 months after operation, the curative effect was evaluated by comparing Japanese Orthopaedic Association (JOA) score at 3 and 6 months after operation, visual analogue scale (VAS) 3 months after operation and intervertebral height at 3 and 6 months after operation with those before operation, and the safety was evaluated by adverse event recording.Results:All 12 patients completed the operation successfully, and the operation sites were thoracic vertebrae in 6 cases (50%), thoracolumbar in 3 cases (25%) and lumbar vertebrae in 3 cases (25%). All patients were followed up. The mean follow-up time was 23.92±3.23 months (range, 19-29 months). No tumor recurrence or metastasis was observed during this period. All patients were followed up at 15 days, 3 months and 6 months after operation. During the 6-month follow-up, X ray results showed that interface of bone and the vertebral body were fused in all of the 12 patients, and the effective rate of fusion was 100%. The 95% confidence interval is calculated to be (75.6%-100%). Six months after operation, the improvement rate of JOA score was excellent in 10 cases, good in 1 case, poor in 1 case, and the excellent and good rate was 91.66%. The preoperative VAS score was 4.08 ±2.47, and during the 3-month follow-up, the VAS score was improved to 1.83 ±1.59. Compared with the preoperative VAS score, the difference was statistically significant ( t=2.635, P=0.023). The intervertebral height before operation, 15 days after operation, 3 months after operation and 6 months after operation were 32.75 (25.94, 68.20), 41.09 (30.55, 70.20), 40.70 (30.23, 67.83) and 40.74 (30.23, 67.08), respectively, and there was no statistically significant difference (χ 2=0.768, P=0.857). No implant-related adverse events occurred after operation. Conclusion:The 3D printing patient-matched artificial vertebral body used in this study has satisfactory short-term efficacy and safety in the reconstruction of spinal stability after spinal tumor resection.
8.Optimization and application of an automatic monitoring module for drug-induced arrhythmias based on population characteristics
Peng LI ; Dai-Hong GUO ; Man ZHU ; Ao GAO ; Hai-Li GUO ; An FU ; An-Qi ZHAO ; Ting-Yong SHI
The Chinese Journal of Clinical Pharmacology 2024;40(9):1345-1349
Objective To develop the functions and optimize the automatic monitoring module for arrhythmias of the adverse drug event active surveillance and assessment system-Ⅱ,in order to continuously improve the performance,enhance the monitoring efficiency,and explore the ways to optimize the module.Methods Expand and optimize the functions of the module,increase the customized configuration,and determine the optimal setting conditions;compare the optimized test data with the results of the evaluation studies on the automatic monitoring of drug-induced arrhythmias in large samples of medicated population previously,and verify the optimization extent as well as the accuracy of the module.Results In the new module optimized according to the characteristics of the monitoring population,the function of"mandatory medical order keywords"was added,and it was determined that the inclusion of 6 electrocardiogram examination-related medical order keywords with a frequency of not less than 2 occurrences was the optimal configuration condition for the optimization of the module;combining the results of the previous automatic monitoring and evaluation researches,the system functions were verified and compared under the conditions of using the whole drugs and 2 kinds of single drug.While there was no loss of true positive cases,the number of cases with system alarms decreased by 30.75%,80.13%and 90.82%,respectively,compared with that before the optimization of the module,and the positive predictive value was significantly improved.Conclusion After the function expansion and optimization,the automatic monitoring module of drug-induced arrhythmias significantly reduces the labor cost of case evaluation and keeps the accuracy of monitoring results constant;the new module can better adapt to the demands of different automatic monitoring modes and operates stably,which is more generalizable and flexible,and provides a new way of considering for the research and development of automatic monitoring modules.
10.Effectiveness and safety of laparoscopic-assisted liposuction for treatment of gynaecomastia
Zhiqiang MA ; Jianxin HE ; Ruonan WANG ; Wei GUO ; Mengyuan CHEN ; Hai LU ; Bingshuai SHI
Chinese Journal of Medical Aesthetics and Cosmetology 2024;30(5):501-505
Objective:To explore the effectiveness and safety of laparoscopic-assisted liposuction in the treatment of gynecomastia.Methods:A retrospective study was conducted on 115 male breast development patients from January 2021 to May 2023 at the First Affiliated Hospital of Henan University and Shaoguan Hospital of Southern Medical University. The patients were divided into two groups based on surgical methods: the laparoscopic combined liposuction technique group (observation group) and the traditional areola incision group (control group). The control group consisted of 59 cases, aged between 18 and 52 years (26.2±5.2); There were 56 cases in the observation group, aged between 18 and 55 years (26.5±5.2). The differences in surgical time, intraoperative blood loss, drainage tube removal time, incidence of surgical complications, postoperative drainage volume, pain visual analog scale (VAS), and patient satisfaction were compared between two groups of patients.Results:The intraoperative bleeding volume, drainage tube removal time, and postoperative drainage volume in the observation group were 12.25±2.23, 2.85±0.53, and 80.52±7.53, respectively, all of which were lower than those in the control group (26.53±2.35, 4.22±0.59, 81.25±8.54, respectively), and the differences were statistically significant (all P<0.05).The incidence of sensory abnormalities in the nipple areola area of the observation group was 1.8% (1/56), which was lower than the 10.2% (6/59) of the control group, and the difference was statistically significant ( P<0.05).The postoperative breast shape, nipple shape, and incision score of the observation group were 81.15±18.52, 77.85±22.15, and 72.58±10.56 points, respectively, all higher than the control group's 69.34±18.48, 78.12±21.75, and 60.35±9.35 points, and the differences were statistically significant (all P<0.05). Conclusions:Laparoscopic combined with liposuction technology for the treatment of gynecomastia can reduce intraoperative bleeding and postoperative drainage volume and shorten the time for removing drainage tubes with better safety.

Result Analysis
Print
Save
E-mail