1.Preliminary efficacy observation of 3D printed functional spinal external fixation brace combined with McKenzie therapy in the treatment of lumbar disc herniation.
Ning-Xia WANG ; Ping CHEN ; Hai-Dong WANG ; Jing JI ; Fang-Hong NIAN ; Xin LIU ; Chong-Fei JIN ; Duo-Ming ZHAO ; Hao-Lin LI ; Wei-Gang CHENG ; Gui-Lin LAI ; Guo-Biao WU
China Journal of Orthopaedics and Traumatology 2025;38(10):1047-1054
OBJECTIVE:
To observe the clinical efficacy of 3D printing spinal external fixator combined with McKenzie therapy for patients with lumbar dics herniation (LDH).
METHODS:
Sixty patients with LDH between January 2022 and January 2023 were enrolled. Among them, 30 patients were given McKinsey training. According to different treatment methods, all patients were divided into McKenzie group and McKenzie + 3D printing group, 30 patients in each group. The McKenzie group provided McKenzie therapy. The McKenzie + 3D printing group were treated with 3D printing spinal external fixation brace on the basis of McKenzie therapy. Patients in both groups were between 25 and 60 years of age and had their first illness. In the McKenzie group, there were 19 males and 11 females, with an average age of (48.57±5.86) years old, and the disease duration was (7.03 ±2.39) months. The McKenzie + 3D printing group, there were 21 males and 9 females, with an average age of (48.80±5.92) years old, and the disease duration was(7.30±2.56) months. Pain was evaluated using the visual analogue scale (VAS), and lumbar spine function was assessed using the Oswestry disability index (ODI) and the Japanese Orthopaedic Association (JOA) score. VAS, ODI and JOA scores were compared between two groups before treatment and at 1, 3, 6, 9 and 12 months after treatment.
RESULTS:
All patients were followed up for 12 months. The VAS for the McKenzie combined with 3D printing group before treatment and at 1, 3, 6, 9, and 12 months post-treatment were(6.533±0.860), (5.133±1.008), (3.933±0.868), (2.900±0.759), (2.067±0.640), (1.433±0.504), respectively. In the McKenzie group, the corresponding scores were (6.467±0.860), (5.067±1.048), (4.600±0.968), (3.533±1.008), (2.567±0.728), (1.967±0.809), respectively. The ODI of the McKenzie group before treatment and at 1, 3, 6, 9, and 12 months post-treatment were (41.033±6.810)%, (37.933±6.209)%, (35.467±6.962)%, (27.567±10.081)%, (20.800±7.531)%, (13.533±5.158)%, respectively. For the McKenzie combined with 3D printing group, the corresponding ODI were(38.033±5.605)%, (33.000±6.192)%, (28.767±7.045)%, (22.200±5.517)%, (17.700±4.836)%, (11.900±2.771)%, respectively. The JOA scores of the McKenzie combined with 3D printing group before treatment and at 1, 3, 6, 9, and 12 months post-treatment were(8.900±2.074), (13.133±2.330), (15.700±3.583), (20.400±3.480), (22.267±3.084), (24.833±2.640), respectively. In the McKenzie group, the corresponding scores were(9.200±2.091), (12.267±2.406), (15.333±3.198), (18.467±2.240), (20.133±2.751), (22.467±2.849), respectively. Before the initiation of treatment, no statistically significant differences were observed in the VAS, ODI, and JOA scores between two groups (P>0.05). At 3, 6, 9, and 12 months post-treatment, the VAS in the McKenzie combined with 3D printing group was significantly lower than that in the McKenzie group, and the difference was statistically significant (P<0.05). The comparison of ODI between two groups at 1, 3, 6, 9, and 12 months post-treatment revealed statistically significant differences (P<0.05). At 6, 9, and 12 months post-treatment, the JOA score in the McKenzie combined with 3D printing group was significantly higher than that in the McKenzie-only group, and the difference was statistically significant (P<0.05).
CONCLUSION
The combination of 3D printed functional spinal external fixation brace with McKenzie therapy can significantly improve and maintain lumbar function in patients with LDH.
Humans
;
Male
;
Female
;
Middle Aged
;
Printing, Three-Dimensional
;
Intervertebral Disc Displacement/surgery*
;
External Fixators
;
Lumbar Vertebrae/surgery*
;
Adult
;
Braces
;
Treatment Outcome
2.WW domain-containing ubiquitin E3 ligase 1 regulates immune infiltration in tumor microenvironment of ovarian cancer.
Xiaojuan GUO ; Ruijuan DU ; Liping CHEN ; Kelei GUO ; Biao ZHOU ; Hua BIAN ; Li HAN
Journal of Southern Medical University 2025;45(5):1063-1073
OBJECTIVES:
To explore the association of the expression of WW domain-containing ubiquitin E3 ligase 1 (WWP1) with immune infiltration in tumor microenvironment (TME) of ovarian cancer.
METHODS:
Ovarian cancer patient data from The Cancer Genome Atlas (TCGA) were used to analyze the association of WWP1 expression with patient prognosis. TISCH2 was utilized to analyze the changes in immune cell subtypes in TME of metastatic tumor and after chemotherapy. The impact of WWP1 on immune cell infiltration, somatic copy number alterations of WWP1 and evolution of immune cell subtypes was evaluated using TIMER and TIGER pseudo-time analysis. A deep learning model was used to analyze TCGA pathological images to investigate the effect of WWP1 on TME of ovarian cancer. RNA-seq analysis was conducted to identify the differentially expressed genes in WWP1-overexpressing SKOV3 cells and validate immune infiltration. Multicolor immunofluorescence assay was used to analyze the immune markers in SKOV3 and SKOV3/DDP cell xenografts in nude mice.
RESULTS:
The patients with high WWP1 expression levels had significantly lower overall survival rate (P=0.0012). High WWP1 expression levels and Stage IV disease were both associated with a poor prognosis (P<0.05). In metastatic ovarian cancer or after chemotherapy, the percentages of malignant tumor cells and tumor-associated fibroblasts increased in the TME, accompanied by elevated WWP1 levels. WWP1 expression level was positively correlated with pro-tumorigenic immunosuppressive cells (r=0.1323-0.3955, P<0.05) and negatively with tumor-inhibiting immune cells (r=-0.1949- -0.1333, P<0.05). Specific copy number alterations of WWP1 also influenced CD8+ T cell percentage and neutrophil infiltration levels in the TME. RNA-seq analysis of WWP1-overexpressing SKOV3 cells and immunofluorescence assay of the tumor-bearing mice yielded findings consistent with those of bioinformatics analysis.
CONCLUSIONS
WWP1 may serve as a prognostic biomarker and a potential target for immune regulation in the TME of ovarian cancer.
Female
;
Ovarian Neoplasms/genetics*
;
Humans
;
Ubiquitin-Protein Ligases/metabolism*
;
Tumor Microenvironment/immunology*
;
Animals
;
Mice
;
Cell Line, Tumor
;
Mice, Nude
;
Prognosis
;
Gene Expression Regulation, Neoplastic
3.Expert consensus on clinical application of 177Lu-prostate specific membrane antigen radio-ligand therapy in prostate cancer
Guobing LIU ; Weihai ZHUO ; Yushen GU ; Zhi YANG ; Yue CHEN ; Wei FAN ; Jianming GUO ; Jian TAN ; Xiaohua ZHU ; Li HUO ; Xiaoli LAN ; Biao LI ; Weibing MIAO ; Shaoli SONG ; Hao XU ; Rong TIAN ; Quanyong LUO ; Feng WANG ; Xuemei WANG ; Aimin YANG ; Dong DAI ; Zhiyong DENG ; Jinhua ZHAO ; Xiaoliang CHEN ; Yan FAN ; Zairong GAO ; Xingmin HAN ; Ningyi JIANG ; Anren KUANG ; Yansong LIN ; Fugeng LIU ; Cen LOU ; Xinhui SU ; Lijun TANG ; Hui WANG ; Xinlu WANG ; Fuzhou YANG ; Hui YANG ; Xinming ZHAO ; Bo YANG ; Xiaodong HUANG ; Jiliang CHEN ; Sijin LI ; Jing WANG ; Yaming LI ; Hongcheng SHI
Chinese Journal of Clinical Medicine 2024;31(5):844-850,封3
177Lu-prostate specific membrane antigen(PSMA)radio-ligand therapy has been approved abroad for advanced prostate cancer and has been in several clinical trials in China.Based on domestic clinical practice and experimental data and referred to international experience and viewpoints,the expert group forms a consensus on the clinical application of 177Lu-PSMA radio-ligand therapy in prostate cancer to guide clinical practice.
4.Deep neural networks analysis of 18F-FDG PET imaging in postoperative patients with temporal lobe epilepsy
Huanhua WU ; Shaobo CHEN ; Jingjie SHANG ; Hailing ZHOU ; Biao WU ; Jian GONG ; Xueying LING ; Qiang GUO ; Hao XU
Chinese Journal of Nuclear Medicine and Molecular Imaging 2024;44(4):220-224
Objective:To predict the short-term postoperative recurrence status of patients with refractory temporal lobe epilepsy (TLE) by analyzing preoperative 18F-FDG PET images and patients′ clinical characteristics based on deep residual neural network (ResNet). Methods:Retrospective analysis was conducted on preoperative 18F-FDG PET images and clinical data of 220 patients with refractory TLE (132 males and 88 females, age 23.0(20.0, 30.2) years)) in the First Affiliated Hospital of Jinan University between January 2014 and June 2020. ResNet was used to perform high-throughput feature extraction on preprocessed PET images and clinical features, and to perform a postoperative recurrence prediction task for differentiating patients with TLE. The predictive performance of ResNet model was evaluated by ROC curve analysis, and the AUC was compared with that of classical Cox proportional risk model using Delong test. Results:Based on PET images combined with clinical feature training, AUCs of the ResNet in predicting 12-, 24-, and 36-month postoperative recurrence were 0.895±0.073, 0.861±0.058 and 0.754±0.111, respectively, which were 0.717±0.093, 0.697±0.081 and 0.645±0.087 for Cox proportional hazards model respectively ( z values: -3.00, -2.98, -1.09, P values: 0.011, 0.018, 0.310). The ResNet showed best predictive effect for recurrence events within 12 months after surgery. Conclusion:The ResNet model is expected to be used in clinical practice for postoperative follow-up of patients with TLE, helping for risk stratification and individualized management of postoperative patients.
5.A multicenter study of neonatal stroke in Shenzhen,China
Li-Xiu SHI ; Jin-Xing FENG ; Yan-Fang WEI ; Xin-Ru LU ; Yu-Xi ZHANG ; Lin-Ying YANG ; Sheng-Nan HE ; Pei-Juan CHEN ; Jing HAN ; Cheng CHEN ; Hui-Ying TU ; Zhang-Bin YU ; Jin-Jie HUANG ; Shu-Juan ZENG ; Wan-Ling CHEN ; Ying LIU ; Yan-Ping GUO ; Jiao-Yu MAO ; Xiao-Dong LI ; Qian-Shen ZHANG ; Zhi-Li XIE ; Mei-Ying HUANG ; Kun-Shan YAN ; Er-Ya YING ; Jun CHEN ; Yan-Rong WANG ; Ya-Ping LIU ; Bo SONG ; Hua-Yan LIU ; Xiao-Dong XIAO ; Hong TANG ; Yu-Na WANG ; Yin-Sha CAI ; Qi LONG ; Han-Qiang XU ; Hui-Zhan WANG ; Qian SUN ; Fang HAN ; Rui-Biao ZHANG ; Chuan-Zhong YANG ; Lei DOU ; Hui-Ju SHI ; Rui WANG ; Ping JIANG ; Shenzhen Neonatal Data Network
Chinese Journal of Contemporary Pediatrics 2024;26(5):450-455
Objective To investigate the incidence rate,clinical characteristics,and prognosis of neonatal stroke in Shenzhen,China.Methods Led by Shenzhen Children's Hospital,the Shenzhen Neonatal Data Collaboration Network organized 21 institutions to collect 36 cases of neonatal stroke from January 2020 to December 2022.The incidence,clinical characteristics,treatment,and prognosis of neonatal stroke in Shenzhen were analyzed.Results The incidence rate of neonatal stroke in 21 hospitals from 2020 to 2022 was 1/15 137,1/6 060,and 1/7 704,respectively.Ischemic stroke accounted for 75%(27/36);boys accounted for 64%(23/36).Among the 36 neonates,31(86%)had disease onset within 3 days after birth,and 19(53%)had convulsion as the initial presentation.Cerebral MRI showed that 22 neonates(61%)had left cerebral infarction and 13(36%)had basal ganglia infarction.Magnetic resonance angiography was performed for 12 neonates,among whom 9(75%)had involvement of the middle cerebral artery.Electroencephalography was performed for 29 neonates,with sharp waves in 21 neonates(72%)and seizures in 10 neonates(34%).Symptomatic/supportive treatment varied across different hospitals.Neonatal Behavioral Neurological Assessment was performed for 12 neonates(33%,12/36),with a mean score of(32±4)points.The prognosis of 27 neonates was followed up to around 12 months of age,with 44%(12/27)of the neonates having a good prognosis.Conclusions Ischemic stroke is the main type of neonatal stroke,often with convulsions as the initial presentation,involvement of the middle cerebral artery,sharp waves on electroencephalography,and a relatively low neurodevelopment score.Symptomatic/supportive treatment is the main treatment method,and some neonates tend to have a poor prognosis.
6.Safety and efficacy of domestically produced novel bioabsorbable vascular scaff old in the treatment of complex coronary artery lesions for 3 years
Deng-Shuang ZHOU ; Qiong YOU ; Hai-Liang MO ; Zi-Jun WU ; Yu-Biao LIN ; Lu-Jun CHEN ; Jun-Yu FAN ; Yong-Jian LIN ; Rui-Sheng ZHANG ; Pei-Shan WAN ; Wei-Guo ZHOU ; Keng WU
Chinese Journal of Interventional Cardiology 2024;32(9):509-515
Objective To investigate the safety and efficacy of novel bioabsorbable vascular scaffold(BVS)in the treatment of patients with complex coronary artery disease.Methods This was a retrospective,matched,single-center observational study.45 patients with coronary atherosclerotic cardiopathy received BVS treatment in the cardiovascular medicine department Department of the Affiliated Hospital of Guangdong Medical University from June 2020 to June 2021(BVS),and 45 patients treated with drug-eluting stents(DES)group were selected according to matching study requirements during the same period.Baseline,surgical,and follow-up data were compared between the two groups to evaluate safety and efficacy.The main measures of safety were:surgical time,intraoperative adverse events,etc.,and the end point of efficacy was target lesion failure(TLF),including cardiac death,target vessel myocardial infarction,and ischa-driven target lesion revascularization.Results A total of 90 patients were enrolled in this study,all of whom were followed up for at least 3 years.There were 20 cases of bifurcation lesions and 25 cases of diffuse long lesions in the two groups,and 50 cases of imaging were reviewed among the 90 patients.The proportion of stable coronary heart disease,history of diabetes,history of hypertension,history of smoking,pre-dilated balloon pressure and postoperative diastolic blood pressure in BVS group was higher than that in DES group,and the proportion of family history was lower than that in DES group(all P<0.05).There were no statistically significant differences in the rates of cardiac death,target vessel myocardial infarction,and ischemia-driven revascularization of target lesions between the two groups(all P>0.05).Binary Logistic regression model analysis showed that the diameter stenosis ratio of target lesions was an independent risk factor for intrastent restenosis(OR 2.786,95%CI 1.096-7.081,P=0.031).Conclusions Compared with traditional DES,BVS implantation has consistent safety and efficacy in the treatment of complex coronary artery disease within 3 years.The diameter stenosis ratio of target lesions was an independent risk factor for intrastent restenosis.
7.Therapeutic effect of reinfusion of tumor-infiltrating lymphocyte with CRISPR/CAS9 knockout PD-1 on colon cancer in mice
Ziwei QU ; Xiaohui LI ; Jianhui GUO ; Huatao CHEN ; Biao WU ; Qingbin MENG
Chinese Journal of Immunology 2024;40(6):1189-1196
Objective:To investigate therapeutic effect of reinfusion of tumor-infiltrating lymphocyte(TIL)with clustered regularly interspaced short palindromic repeats/CRISPR-associated 9(CRISPR/CAS9)knockout programmed death-1(PD-1)on colon cancer in mice.Methods:Subcutaneous injection of CT26 was used to establish mouse colon cancer model.TIL was extracted from tumor tissue of three model mice,and peripheral blood lymphocytes were extracted.PD-1 gene was knocked out of TIL.Reinfusion experiments were divided into control group(Control),lymphocyte group(Lym),tumor-bearing mouse TIL group(TIL),lentivirus empty empty group(pVSV-G-PX458-NC)and PX458-PD-1-sgRNA1 group(PD-1-sgRNA1),with 10 mice in each group.Tumor tissue quality and tumor inhibition rate were detected in each group.TUNEL was used to detect cell apoptosis in tumor tissues of mice.ELISA was used to detect contents of TNF-α and IFN-γ in tumor tissues of mice.Immunohistochemistry was used to detect expressions of CD4+T and CD8+T cells in tumor tissue.Immunofluorescence was used to detect expressions of proliferating cell nuclear antigen-67(Ki-67)and vascular endothelial growth factor(VEGF).Western blot was used to detect expressions of PD-1 and its ligand PD-L1 in tumor tissues.Results:PD-1-sgRNA1 could significantly inhibit growth of mouse tumor cells in vivo,inhibit expressions of Ki-67 and VEGF in tumor tissues,as well as expressions of PD-1 and PD-L1,elevate apoptosis rate,contents of TNF-α and IFN-γ in tumor tissues,and expressions of CD4+T and CD8+T cells(all P<0.05).Conclusion:Reinfusion of TIL with CRISPR/CAS9 knockout PD-1 can significantly inhibit expressions of Ki-67 and VEGF in colon cancer mice,enhance infiltration of CD4+T and CD8+T cells,induce tumor cell apoptosis and inhibit tumor growth.
8.Design of dilation incision device for neurosurgical procedures
Yu-Wei HAN ; Li-Gang CHEN ; Xin-Yu YANG ; Shun GONG ; Guo-Biao LIANG ; Hai JIN ; Jie-Yu LAI
Chinese Medical Equipment Journal 2024;45(10):37-40
Objective To design and evaluate a dilation incision device capable of facilitating stable support and flexible adjustment during neurosurgical procedures.Methods The dilation incision device was composed of a support plate,an adjustment assembly,a brain support ring,a rotation assembly,an electric motor,an expansion assembly and a neck support ring.The support plate was made of high-strength stainless steel;the adjustment assembly was made up of a first screw,a lifting groove,a slide bar and a nut;the brain support ring was fixed to the adjustment assembly through a support rod,with an outer layer of medical-grade silicone and an inner layer of stainless steel skeleton;the rotation assembly connected the brain support ring with the expansion assembly and consisted of a rotating shaft,a connecting rod and a rotating lug;a high-precision direct current servo motor was selected for the device;the expansion assembly included a spring,an expansion plate and a moving plate,which realized auto expansion or contraction through spring pressure;the neck support ring had its outer layer made of flexible polyurethane foam and inner layer being a stainless steel skeleton.The device had its stability and safety evaluated by static and dynamic tests at different heights(50,100,150 mm)and angles(0°,30°,60°),which was compared with the traditional fixation device to verify its application effect.Results Static and dynamic tests indicated the device showed high stability and safety in different heights and angles,and gained advantages over the traditional device in stability,convenient operation and surgical field visualization.Conclusion The device developed meets the requirements of neurosurgical procedures,and enhances the safety and portability of neurosurgical procedures.[Chinese Medical Equipment Journal,2024,45(10):37-40]
9.Establishment and practice of a teaching case system based on standardized residency training process management
Huaiwei HE ; Jinxiang ZHANG ; Tao GUO ; Biao CHEN ; Jinghui NAN ; Ye TIAN
Chinese Journal of Medical Education Research 2024;23(11):1567-1571
In order to strengthen standardized residency training process management, Union Hospital Affiliated to Tongji Medical College of Huazhong University of Science and Technology combines informatization with teaching case library and establishes and improves the process of teaching case filling from the three aspects of the module for residency teaching case filling, the module for instructor feedback, and the module for functional department management, thereby establishing a teaching case system centered on residents and based on the standardized residency training process management and supporting the innovation of standardized residency training pattern with an integrated teaching platform, which provides new methods for the connotation construction of standardized residency training.
10.Expert consensus on ethical requirements for artificial intelligence (AI) processing medical data.
Cong LI ; Xiao-Yan ZHANG ; Yun-Hong WU ; Xiao-Lei YANG ; Hua-Rong YU ; Hong-Bo JIN ; Ying-Bo LI ; Zhao-Hui ZHU ; Rui LIU ; Na LIU ; Yi XIE ; Lin-Li LYU ; Xin-Hong ZHU ; Hong TANG ; Hong-Fang LI ; Hong-Li LI ; Xiang-Jun ZENG ; Zai-Xing CHEN ; Xiao-Fang FAN ; Yan WANG ; Zhi-Juan WU ; Zun-Qiu WU ; Ya-Qun GUAN ; Ming-Ming XUE ; Bin LUO ; Ai-Mei WANG ; Xin-Wang YANG ; Ying YING ; Xiu-Hong YANG ; Xin-Zhong HUANG ; Ming-Fei LANG ; Shi-Min CHEN ; Huan-Huan ZHANG ; Zhong ZHANG ; Wu HUANG ; Guo-Biao XU ; Jia-Qi LIU ; Tao SONG ; Jing XIAO ; Yun-Long XIA ; You-Fei GUAN ; Liang ZHU
Acta Physiologica Sinica 2024;76(6):937-942
As artificial intelligence technology rapidly advances, its deployment within the medical sector presents substantial ethical challenges. Consequently, it becomes crucial to create a standardized, transparent, and secure framework for processing medical data. This includes setting the ethical boundaries for medical artificial intelligence and safeguarding both patient rights and data integrity. This consensus governs every facet of medical data handling through artificial intelligence, encompassing data gathering, processing, storage, transmission, utilization, and sharing. Its purpose is to ensure the management of medical data adheres to ethical standards and legal requirements, while safeguarding patient privacy and data security. Concurrently, the principles of compliance with the law, patient privacy respect, patient interest protection, and safety and reliability are underscored. Key issues such as informed consent, data usage, intellectual property protection, conflict of interest, and benefit sharing are examined in depth. The enactment of this expert consensus is intended to foster the profound integration and sustainable advancement of artificial intelligence within the medical domain, while simultaneously ensuring that artificial intelligence adheres strictly to the relevant ethical norms and legal frameworks during the processing of medical data.
Artificial Intelligence/legislation & jurisprudence*
;
Humans
;
Consensus
;
Computer Security/standards*
;
Confidentiality/ethics*
;
Informed Consent/ethics*

Result Analysis
Print
Save
E-mail