1.Comparative study of Fast BLADE sequence and conventional BLADE sequence in liver T2WI imaging
Danni WANG ; Xingrui DU ; Guijin LI ; Ling YANG
Journal of Chinese Physician 2025;27(9):1361-1365
Objective:To qualitatively and quantitatively compare and evaluate the application of the Fast BLADE sequence and the conventional BLADE sequence in 3T magnetic resonance (MR) liver T2-weighted imaging (T2WI).Methods:A total of 72 patients who underwent liver MR examination at the Chongqing People′s Hospital from December 2023 to July 2024 were selected. All patients underwent liver magnetic resonance imaging (MRI) scanning using a 3T MR scanner, including both the Fast BLADE sequence and the conventional BLADE sequence. The total imaging time of the two sequences was recorded. Two observers used a " 5-point scale" to evaluate the overall image quality, motion artifacts, and radial artifacts of the Fast BLADE and conventional BLADE sequences respectively, and measured the image signal-to-noise ratio (SNR) at the same spatial position in the two groups of images. Statistical analysis was used to evaluate the differences in imaging time and image quality between the Fast BLADE sequence and the conventional BLADE sequence in liver T2WI imaging.Results:The imaging time of the Fast BLADE sequence in liver T2WI imaging was significantly shorter than that of the conventional BLADE sequence ( P<0.01), and the image SNR was significantly higher than that of the conventional BLADE sequence ( P<0.01). The overall image quality, motion artifact reduction, and radial artifact reduction of the Fast BLADE sequence were all superior to those of the conventional BLADE sequence (all P<0.05). The Kappa coefficients for the consistency of the two observers′ evaluations on overall image quality, motion artifacts, and radial artifacts were 0.78, 0.66, and 0.71 respectively. Conclusions:The Fast BLADE sequence can shorten the imaging time and provide images with higher SNR, and thus can replace the conventional BLADE sequence for liver T2WI imaging.
2.Comparative study of Fast BLADE sequence and conventional BLADE sequence in liver T2WI imaging
Danni WANG ; Xingrui DU ; Guijin LI ; Ling YANG
Journal of Chinese Physician 2025;27(9):1361-1365
Objective:To qualitatively and quantitatively compare and evaluate the application of the Fast BLADE sequence and the conventional BLADE sequence in 3T magnetic resonance (MR) liver T2-weighted imaging (T2WI).Methods:A total of 72 patients who underwent liver MR examination at the Chongqing People′s Hospital from December 2023 to July 2024 were selected. All patients underwent liver magnetic resonance imaging (MRI) scanning using a 3T MR scanner, including both the Fast BLADE sequence and the conventional BLADE sequence. The total imaging time of the two sequences was recorded. Two observers used a " 5-point scale" to evaluate the overall image quality, motion artifacts, and radial artifacts of the Fast BLADE and conventional BLADE sequences respectively, and measured the image signal-to-noise ratio (SNR) at the same spatial position in the two groups of images. Statistical analysis was used to evaluate the differences in imaging time and image quality between the Fast BLADE sequence and the conventional BLADE sequence in liver T2WI imaging.Results:The imaging time of the Fast BLADE sequence in liver T2WI imaging was significantly shorter than that of the conventional BLADE sequence ( P<0.01), and the image SNR was significantly higher than that of the conventional BLADE sequence ( P<0.01). The overall image quality, motion artifact reduction, and radial artifact reduction of the Fast BLADE sequence were all superior to those of the conventional BLADE sequence (all P<0.05). The Kappa coefficients for the consistency of the two observers′ evaluations on overall image quality, motion artifacts, and radial artifacts were 0.78, 0.66, and 0.71 respectively. Conclusions:The Fast BLADE sequence can shorten the imaging time and provide images with higher SNR, and thus can replace the conventional BLADE sequence for liver T2WI imaging.
3.MRI features of primary hepatic neuroendocrine tumor
Yongnan PIAO ; Haiyi WANG ; Lu MA ; Guo YU ; Guijin DU ; Huiyi YE ; Guifang LIU
Chinese Journal of Radiology 2018;52(2):125-130
Objective To investigate the MRI features of primary hepatic neuroendocrine tumor (PHNET). Methods Clinical information and MR imaging features of 13 histopathologically confirmed PHNET patients were retrospectively reviewed. All patients underwent routine MRI examination including T2WI and chemical shift imaging, diffusion weighted imaging (DWI) and dynamic contrast-enhanced imaging. All lesions were divided into two groups according to the maximum diameter (≥ 30 mm for large lesion group and<30 mm for small lesion group). The following MRI features of lesions were evaluated:location, size, growth pattern, signal intensity (T1WI, T2WI, DWI, in-and opposed-phase) and dynamic contrast-enhancement pattern. The pathologic features were also analyzed. Results The PHNET can be single lesion(n=7)or multiple lesions(n=6)in which 4 cases showed diffuse pattern.One hundred and six lesions in 13 patients were detected.The median diameter of all lesions was 20 mm(ranging from 3 to 200 mm).Fourteen lesions were found in≥30 mm group and 92 lesions in<30 mm group.(1)In≥30 mm group,all lesions had well-defined margin,heterogeneous hyperintensity on T2WI,heterogeneous hypointensity on T1WI and halo sign on DWI. All lesions showed cystic degeneration, necrosis and pseudo-capsule. Three lesions showed dilation of bile duct around the lesion, and three lesions hemorrhaged and three lesions signal dropped on out-of-phase.On arterial phase,7 lesions showed ring-like enhancement,and the other 7 lesions showed heterogeneous enhancement;then on portal venous phase and delayed phase, 8 lesions showed persistent enhancement and the other 6 lesions showed"wash-out"appearance.Three cases showed lymphadenopathy in the peritoneum and liver hilum. (2) In<30 mm group, 76 lesions showed well-circumscribed edge and the other 16 lesions had ill-defined margin. Eighty two lesions showed relatively homogeneous hyperintensity on T2WI and relatively homogeneous hypointensity on T1WI. One lesion showed heterogeneous hyperintensity on T2WI and heterogeneous hypointensity on T1WI.Nine lesions showed halo and nodular hyperintensity and the other 83 lesions nodular hyperintensity on DWI.Ten lesions demonstrated cystic degeneration and necrosis. Ten lesions showed pseudocapsule. All lesions showed no dilation of bile duct, hemorrhage and signal drop on out-of-phase. On arterial phase, 31 lesions showed ring-like enhancement, 3 lesions showed heterogeneous enhancement and 58 lesions showed homogeneous enhancement;on portal venous phase and delayed phase,62 lesions showed persistent enhancement and 30 lesions showed"wash-out"sign. No lymphadenopathy was found in this group. In the pathologic analysis, hemorrhage and central necrosis were detected in the gross specimens.And in the 13 cases of PHNET,1,3 and 9 cases were classified into G1, G2 and G3 grade, respectively. Conclusions The PHNET can be single or multiple with various sizes. The large lesions often show heterogeneous signal intensity on T2WI and T1WI with cystic degeneration, necrosis, hemorrhage, pseudo-capsule and dilated bile duct, peripheral hyperintensity on DWI, ring-enhancement or heterogeneous slight enhancement in arterial phase, while small lesions often show ring-enhancement or homogeneous obvious enhancement in arterial phase.
4.Behavioral study of internet gaming addiction in adolescents
Xiaodong LI ; Yongxin YANG ; Yunting ZHANG ; Quan ZHANG ; Linxiang LIU ; Guijin DU ; Songtao ZHAO ; Baotao LU
Chinese Journal of Behavioral Medicine and Brain Science 2011;20(6):535-537
Objective To explore the facilitative mechanism of the behavioral improvement resulting from gaming experience in internet gaming addicts. Methods Seventeen gaming addicts and twenty normal subjects were involved in the study, and their behavioral performance were evaluated by using the revised paradigm of event-related design. Results 1. Mean reaction times (RTs) under valid and invalid cue conditions were ( (614.27 ± 85.25)ms,(645.4±80.24)ms)and ((710.24 ± 131.42)ms,(765.53 ± 142. 53)ms) respectively. There were statistically significant differences of mean RTs within each group (P < 0. 05 ) and between the two groups (P < 0.01 ). 2. There were statistically significant differences of mean RTs on three cue levels between addiction group (online game picture(643.65 ±90.82) ms,neutral face picture(616. 73 ±82. 19)ms,neutral picture(629. 21 ± 78.20)ms) and control group(game picture (744. 54 ± 140. 42) ms, neutral face picture ( 727. 98 ± 142.26)ms, neutral picture(741. 13 ±138. 21)ms, P<0.05).3. There were statistically significant differences on trends of mean RTs on three cue levels of addiction group between valid cue condition ( online game picture (619. 02 ± 91.00) ms,neutral face picture (604.90 ±90. 71 )ms,neutral picture (618.87 ±77.85)ms) and invalid cue con-dition( online game picture ( 668. 28 ± 86. 27 ) ms, neutral face picture ( 628. 56 ± 73. 53 ) ms, neutral picture (639.54 ±79. 54) ms, P<0. 05). Conclusion Both exogenous and endogenous attention orientation are improved in internet gaming addicts. Enhancement of endogenous attention function resulting from gaming experience might be greater than that of exogenous attention.
5.The Determination of Serum IL-6 in Cholangiocarcinoma Significance
Guijin HE ; Huailin DU ; Zhenlong XIA ; Xianwei DAI ; Bai SONG
Journal of China Medical University 2001;30(2):145-146
Objective: To explore the clinical significance. Methods: The double-antibody sandwich ELISA technique. Result: The serum interleukin-6(IL-6) levels of patients with cholangiocarcinoma are significantly higher than those in benign biliary disease and normal controls (P<0.05). Conclusion: Serum IL-6 levels of patients with cholangiocarcinoma are significantly increased ,it is one of the important parameters for clinical evaluation in patients of cholangiocarcinoma.

Result Analysis
Print
Save
E-mail