1.Quality evaluation of Gegen Formula Granules
Dai-liang ZHANG ; Chun-xia WANG ; Lei SHI ; Yu-kang LIU ; Yong-qiang LIN ; Yu-zhuo WANG ; Jing-hua ZHANG ; Jin-xin LI ; Gui-yun CAO ; Zhao-qing MENG
Chinese Traditional Patent Medicine 2025;47(5):1421-1431
AIM To evaluate the quality of Gegen Formula Granules.METHODS Linear calibration with two reference substances(LCTRS)was adopted in the predicting of retention time with puerarin and daidzein as internal standards.UPLC characteristic chromatograms were established.The contents of 3'-hydroxy puerarin,puerarin(internal standard),3'-methoxy puerarin,puerarin 6"-O-xyloside,puerarin apioside and daidzin were determined by quantitative determination analysis multi-components by a single marker(QAMS),after which their transfer rates were calculated.RESULTS Compared with relative retention time method,LCTRS demonstrated higher positional accuracy for characteristic peaks and wider application range for columns.There were 9 characteristic peaks in the characteristic chromatograms for 14 batches of formula granules and 15 batches of standard decoctions with the similarities of more than 0.95.The contents and transfer rates of various constituents in formula granules and standard decoctions were basically consistent.CONCLUSION The chemical constituents in formula granules and their standard decoctions of Puerariae lobatae Radix display good consistency,reliable preparation process is observable in the former.
2.Application Value of Vertebral CT Values in Fresh and Old Fractures Vertebral Bodies of Patients with Osteoporotic Vertebral Compression Fractures
Feng WANG ; Wei-sheng PENG ; Gui-liu CHEN ; Na DENG ; Xiao-bing HAN ; Hui-liang CAI ; Qiu-xiang CHEN
Progress in Modern Biomedicine 2025;25(19):3179-3185
Objective:To explore the value of using computed tomography(CT)values to distinguish fresh and old fractures vertebral bodies in osteoporotic vertebral compression fractures(OVCF).Methods:Retrospective analysis of clinical data of 101 OVCF patients in our hospital from September 2022 to September 2023.Kappa test for consistency between magnetic resonance imaging(MRI)and vertebral CT values in distinguished fresh or old OVCF.The difference of CT values between fresh,old fractures and adjacent normal vertebral bodies were compared.The diagnostic efficiency was analyed by receiver operating characteristic(ROC)curve.Results:There was a high consistency between vertebral CT values and MRI in the diagnosis of OVCF in fresh and old fractures(Kappa value=0.934).There was a difference in difference of CT values between adjacent normal vertebral bodies and fresh fractures vertebral bodies(P<0.05).There was a difference in difference of CT values of fresh fractures vertebral bodies and old fractures vertebral bodies(P<0.05).The ROC curve analysis results showed that,the combined measurement of CT values of fresh and old fractured vertebral bodies has an area under the curve(AUC)of 0.723,which was higher than alone measurement of the CT values of fresh fractured vertebral bodies and old fractured vertebral bodies of 0.536 and 0.610(Z=2.548,2.605,2.841,P<0.05).Conclusion:CT values of vertebral bodies show high consistency in distinguish fresh and old fractures of OVCF compared to MRI findings,and the diagnostic efficiency of combine detection is relatively high.
3.Diagnostic Value of Conventional CT Combined with Enhanced CT Scan in Bone Metastases
Feng WANG ; Gui-liu CHEN ; Wei-sheng PENG ; Na DENG ; Xiao-bing HAN ; Hui-liang CAI ; Qiu-xiang CHEN
Progress in Modern Biomedicine 2025;25(20):3337-3344
Objective:To explore the diagnostic value of conventional computed tomography(CT)combined with enhanced CT scan in bone metastases.Methods:This study was a retrospective observational study,84 suspected bone metastases patients admitted to our hospital from January 2022 to August 2024 were selected,All patients underwent conventional CT and enhanced CT scan and pathological examination,Using pathological examination results as the"gold standard"for diagnosis.The imaging manifestations of bone metastases using conventional CT combined with enhanced CT scan examination were observed;The detection rate and bone metastases types of conventional CT and enhanced CT scan were analyzed;The bone metastases location in different types of malignant tumors were analyzed;The detection results of bone metastases between conventional CT and enhanced CT scan were compared;the diagnostic efficacy of conventional CT and enhanced CT scan alone and in combination for bone metastases were analyzed by Receiver operating characteristic(ROC)curve.Results:The detection rate of osteogenic,osteolytic,cystic and mixed bone metastases by conventional CT combined with enhanced CT scan was supered to that of conventional CT and enhanced CT scan alone(P<0.05).Bone metastases from lung cancer,breast cancer and other tumors mainly occur in the spine,limbs and ribs,while esophageal cancer,gastric cancer,liver cancer,prostate cancer,thyroid cancer,renal cancer,and nasopharyngeal cancer had relatively fewer bone metastases.The positive detection cases of bone metastases used conventional CT combined with enhanced CT scan were supered to those used conventional CT and enhanced CT scan alone.The sensitivity,specificity and accuracy of conventional CT combined with enhanced CT scan for the diagnosis of bone metastases were 94.00%,94.11%and 94.04%,respectively,and the positive/negative predictive values were 95.91%and 91.42%,respectively.The sensitivity,specificity and accuracy of conventional CT scan were 84.00%,78.78%and 80.95%,respectively,and the positive/negative predictive values were 85.71%and 74.28%,respectively.The sensitivity,specificity and accuracy of enhanced CT were 89.79%,85.71%and 88.09%,respectively.and the positive and negative predictive values were 89.79%and 85.71%,respectively.The diagnostic efficacy of conventional CT combined with enhanced CT scan for bone metastases was significantly better than that of conventional CT and enhanced CT scan alone.Conclusions:Conventional CT combined with enhanced CT scan can significantly improve the diagnostic efficiency of bone metastases,and provide an important basis for clinical treatment.
4.Application Value of Vertebral CT Values in Fresh and Old Fractures Vertebral Bodies of Patients with Osteoporotic Vertebral Compression Fractures
Feng WANG ; Wei-sheng PENG ; Gui-liu CHEN ; Na DENG ; Xiao-bing HAN ; Hui-liang CAI ; Qiu-xiang CHEN
Progress in Modern Biomedicine 2025;25(19):3179-3185
Objective:To explore the value of using computed tomography(CT)values to distinguish fresh and old fractures vertebral bodies in osteoporotic vertebral compression fractures(OVCF).Methods:Retrospective analysis of clinical data of 101 OVCF patients in our hospital from September 2022 to September 2023.Kappa test for consistency between magnetic resonance imaging(MRI)and vertebral CT values in distinguished fresh or old OVCF.The difference of CT values between fresh,old fractures and adjacent normal vertebral bodies were compared.The diagnostic efficiency was analyed by receiver operating characteristic(ROC)curve.Results:There was a high consistency between vertebral CT values and MRI in the diagnosis of OVCF in fresh and old fractures(Kappa value=0.934).There was a difference in difference of CT values between adjacent normal vertebral bodies and fresh fractures vertebral bodies(P<0.05).There was a difference in difference of CT values of fresh fractures vertebral bodies and old fractures vertebral bodies(P<0.05).The ROC curve analysis results showed that,the combined measurement of CT values of fresh and old fractured vertebral bodies has an area under the curve(AUC)of 0.723,which was higher than alone measurement of the CT values of fresh fractured vertebral bodies and old fractured vertebral bodies of 0.536 and 0.610(Z=2.548,2.605,2.841,P<0.05).Conclusion:CT values of vertebral bodies show high consistency in distinguish fresh and old fractures of OVCF compared to MRI findings,and the diagnostic efficiency of combine detection is relatively high.
5.Diagnostic Value of Conventional CT Combined with Enhanced CT Scan in Bone Metastases
Feng WANG ; Gui-liu CHEN ; Wei-sheng PENG ; Na DENG ; Xiao-bing HAN ; Hui-liang CAI ; Qiu-xiang CHEN
Progress in Modern Biomedicine 2025;25(20):3337-3344
Objective:To explore the diagnostic value of conventional computed tomography(CT)combined with enhanced CT scan in bone metastases.Methods:This study was a retrospective observational study,84 suspected bone metastases patients admitted to our hospital from January 2022 to August 2024 were selected,All patients underwent conventional CT and enhanced CT scan and pathological examination,Using pathological examination results as the"gold standard"for diagnosis.The imaging manifestations of bone metastases using conventional CT combined with enhanced CT scan examination were observed;The detection rate and bone metastases types of conventional CT and enhanced CT scan were analyzed;The bone metastases location in different types of malignant tumors were analyzed;The detection results of bone metastases between conventional CT and enhanced CT scan were compared;the diagnostic efficacy of conventional CT and enhanced CT scan alone and in combination for bone metastases were analyzed by Receiver operating characteristic(ROC)curve.Results:The detection rate of osteogenic,osteolytic,cystic and mixed bone metastases by conventional CT combined with enhanced CT scan was supered to that of conventional CT and enhanced CT scan alone(P<0.05).Bone metastases from lung cancer,breast cancer and other tumors mainly occur in the spine,limbs and ribs,while esophageal cancer,gastric cancer,liver cancer,prostate cancer,thyroid cancer,renal cancer,and nasopharyngeal cancer had relatively fewer bone metastases.The positive detection cases of bone metastases used conventional CT combined with enhanced CT scan were supered to those used conventional CT and enhanced CT scan alone.The sensitivity,specificity and accuracy of conventional CT combined with enhanced CT scan for the diagnosis of bone metastases were 94.00%,94.11%and 94.04%,respectively,and the positive/negative predictive values were 95.91%and 91.42%,respectively.The sensitivity,specificity and accuracy of conventional CT scan were 84.00%,78.78%and 80.95%,respectively,and the positive/negative predictive values were 85.71%and 74.28%,respectively.The sensitivity,specificity and accuracy of enhanced CT were 89.79%,85.71%and 88.09%,respectively.and the positive and negative predictive values were 89.79%and 85.71%,respectively.The diagnostic efficacy of conventional CT combined with enhanced CT scan for bone metastases was significantly better than that of conventional CT and enhanced CT scan alone.Conclusions:Conventional CT combined with enhanced CT scan can significantly improve the diagnostic efficiency of bone metastases,and provide an important basis for clinical treatment.
6.The addition of 5-aminolevulinic acid to HBSS protects testis grafts during hypothermic transportation: a novel preservation strategy.
Meng-Hui MA ; Pei-Gen CHEN ; Jun-Xian HE ; Hai-Cheng CHEN ; Zhen-Han XU ; Lin-Yan LV ; Yan-Qing LI ; Xiao-Yan LIANG ; Gui-Hua LIU
Asian Journal of Andrology 2025;27(4):454-463
The aim of this investigation was to determine the optimal storage medium for testicular hypothermic transportation and identify the ideal concentration for the application of the protective agent 5-aminolevulinic acid (5-ALA). Furthermore, this study aimed to explore the underlying mechanism of the protective effects of 5-ALA. First, we collected and stored mouse testicular fragments in different media, including Hank's balanced salt solution (HBSS; n = 5), Dulbecco's Modified Eagle Medium/Nutrient Mixture F-12 (DMEM/F12; n = 5), and alpha-minimum essential medium (αMEM; n = 5). Storage of testicular tissue in HBSS preserved the integrity of testicular morphology better than that in the DMEM/F12 group ( P < 0.05) and the αMEM group ( P < 0.01). Testicular fragments were subsequently placed in HBSS with various concentrations of 5-ALA (0 [control], 1 mmol l -1 , 2 mmol l -1 , and 5 mmol l -1 ) to determine the most effective concentration of 5-ALA. The 2 mmol l -1 5-ALA group ( n = 3) presented the highest positive rate of spermatogonial stem cells compared with those in the control, 1 mmol l -1 , and 5 mmol l -1 5-ALA groups. Finally, the tissue fragments were preserved in HBSS with control ( n = 3) and 2 mmol l -1 5-ALA ( n = 3) under low-temperature conditions. A comparative analysis was performed against fresh testes ( n = 3) to elucidate the underlying mechanism of 5-ALA. Gene set enrichment analysis (GSEA) for WikiPathways revealed that the p38 mitogen-activated protein kinase (MAPK) signaling pathway was downregulated in the 2 mmol l -1 5-ALA group compared with that in the control group (normalized enrichment score [NES] = -1.57, false discovery rate [FDR] = 0.229, and P = 0.019). In conclusion, these data suggest that using 2 mmol l -1 5-ALA in HBSS effectively protected the viability of spermatogonial stem cells upon hypothermic transportation.
Male
;
Animals
;
Testis/cytology*
;
Aminolevulinic Acid/pharmacology*
;
Mice
;
Organ Preservation/methods*
;
Organ Preservation Solutions/pharmacology*
;
Cryopreservation/methods*
7.Body fat distribution and semen quality in 4304 Chinese sperm donors.
Si-Han LIANG ; Qi-Ling WANG ; Dan LI ; Gui-Fang YE ; Ying-Xin LI ; Wei ZHOU ; Rui-Jun XU ; Xin-Yi DENG ; Lu LUO ; Si-Rong WANG ; Xin-Zong ZHANG ; Yue-Wei LIU
Asian Journal of Andrology 2025;27(4):524-530
Extensive studies have identified potential adverse effects on semen quality of obesity, based on body mass index, but the association between body fat distribution, a more relevant indicator for obesity, and semen quality remains less clear. We conducted a longitudinal study of 4304 sperm donors from the Guangdong Provincial Human Sperm Bank (Guangzhou, China) during 2017-2021. A body composition analyzer was used to measure total and local body fat percentage for each participant. Generalized estimating equations were employed to assess the association between body fat percentage and sperm count, motility, and morphology. We estimated that each 10% increase in total body fat percentage (estimated change [95% confidence interval, 95% CI]) was significantly associated with a 0.18 × 10 6 (0.09 × 10 6 -0.27 × 10 6 ) ml and 12.21 × 10 6 (4.52 × 10 6 -19.91 × 10 6 ) reduction in semen volume and total sperm count, respectively. Categorical analyses and exposure-response curves showed that the association of body fat distribution with semen volume and total sperm count was stronger at higher body fat percentages. In addition, the association still held among normal weight and overweight participants. We observed similar associations for upper limb, trunk, and lower limb body fact distributions. In conclusion, we found that a higher body fat distribution was significantly associated with lower semen quality (especially semen volume) even in men with a normal weight. These findings provide useful clues in exploring body fat as a risk factor for semen quality decline and add to evidence for improving semen quality for those who are expected to conceive.
Humans
;
Male
;
Adult
;
Semen Analysis
;
China
;
Body Fat Distribution
;
Longitudinal Studies
;
Sperm Count
;
Sperm Motility
;
Body Mass Index
;
Tissue Donors
;
Obesity/complications*
;
Spermatozoa
;
Young Adult
;
Middle Aged
;
East Asian People
8.International clinical practice guideline on the use of traditional Chinese medicine for functional dyspepsia (2025).
Sheng-Sheng ZHANG ; Lu-Qing ZHAO ; Xiao-Hua HOU ; Zhao-Xiang BIAN ; Jian-Hua ZHENG ; Hai-He TIAN ; Guan-Hu YANG ; Won-Sook HONG ; Yu-Ying HE ; Li LIU ; Hong SHEN ; Yan-Ping LI ; Sheng XIE ; Jin SHU ; Bin-Fang ZENG ; Jun-Xiang LI ; Zhen LIU ; Zheng-Hua XIAO ; Jing-Dong XIAO ; Pei-Yong ZHENG ; Shao-Gang HUANG ; Sheng-Liang CHEN ; Gui-Jun FEI
Journal of Integrative Medicine 2025;23(5):502-518
Functional dyspepsia (FD), characterized by persistent or recurrent dyspeptic symptoms without identifiable organic, systemic or metabolic causes, is an increasingly recognized global health issue. The objective of this guideline is to equip clinicians and nursing professionals with evidence-based strategies for the management and treatment of adult patients with FD using traditional Chinese medicine (TCM). The Guideline Development Group consulted existing TCM consensus documents on FD and convened a panel of 35 clinicians to generate initial clinical queries. To address these queries, a systematic literature search was conducted across PubMed, EMBASE, the Cochrane Library, China National Knowledge Infrastructure (CNKI), VIP Database, China Biology Medicine (SinoMed) Database, Wanfang Database, Traditional Medicine Research Data Expanded (TMRDE), and the Traditional Chinese Medical Literature Analysis and Retrieval System (TCMLARS). The evidence from the literature was critically appraised using the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) approach. The strength of the recommendations was ascertained through a consensus-building process involving TCM and allopathic medicine experts, methodologists, pharmacologists, nursing specialists, and health economists, leveraging their collective expertise and empirical knowledge. The guideline comprises a total of 43 evidence-informed recommendations that span a range of clinical aspects, including the pathogenesis according to TCM, diagnostic approaches, therapeutic interventions, efficacy assessments, and prognostic considerations. Please cite this article as: Zhang SS, Zhao LQ, Hou XH, Bian ZX, Zheng JH, Tian HH, Yang GH, Hong WS, He YY, Liu L, Shen H, Li YP, Xie S, Shu J, Zeng BF, Li JX, Liu Z, Xiao ZH, Xiao JD, Zheng PY, Huang SG, Chen SL, Fei GJ. International clinical practice guideline on the use of traditional Chinese medicine for functional dyspepsia (2025). J Integr Med. 2025; 23(5):502-518.
Dyspepsia/drug therapy*
;
Humans
;
Medicine, Chinese Traditional/methods*
;
Practice Guidelines as Topic
;
Drugs, Chinese Herbal/therapeutic use*
10.Thermal Ablation of Pulmonary Nodules by Electromagnetic Navigation Bronchoscopy Combined With Real-Time CT-Based 3D Fusion Navigation:Report of One Case.
Yuan XU ; Qun LIU ; Chao GUO ; Yi-Bo WANG ; Xiao-Fang WU ; Chen-Xi MA ; Gui-Ge WANG ; Qian-Shu LIU ; Nai-Xin LIANG ; Shan-Qing LI
Acta Academiae Medicinae Sinicae 2025;47(1):137-141
A nodule in the right middle lobe of the lung was treated by a combination of cone-beam CT,three-dimensional registration for fusion imaging,and electromagnetic navigation bronchoscopy-guided thermal ablation.The procedure lasted for 90 min,with no significant bleeding observed under the bronchoscope.The total radiation dose during the operation was 384 mGy.The patient recovered well postoperatively,with only a small amount of blood in the sputum and no pneumothorax or other complications.A follow-up chest CT on the first day post operation showed that the ablation area completely covered the lesion,and the patient was discharged successfully.
Humans
;
Bronchoscopy/methods*
;
Catheter Ablation/methods*
;
Cone-Beam Computed Tomography
;
Electromagnetic Phenomena
;
Imaging, Three-Dimensional
;
Lung Neoplasms/diagnostic imaging*
;
Tomography, X-Ray Computed

Result Analysis
Print
Save
E-mail