1.Quantitative evaluation of left ventricular remodeling in left bundle branch block induced cardiomyopathy by multimodal imaging
Xiaoxian WANG ; Changqing MIAO ; Beibei GE ; Mingxia LI ; Fen CHEN ; Fang XU ; Ning ZHANG ; Guanjun GUO ; Wei XU ; Wenzhi SHEN ; Yingming ZHAO ; Jing YAO
Chinese Journal of Ultrasonography 2025;34(1):26-32
Objective:To quantitatively evaluate the effects of left bundle branch block(LBBB)on left ventricular structure,function and myocardial perfusion using left ventricular pressure-strain loop and single photon emission computed tomography(SPECT),and to investigate the relationship between myocardial work,myocardial perfusion and pathological changes of left ventricular remodeling in left bundle branch block induced cardiomyopathy(LBBB-CM).Methods:Fourteen male beagle dogs were selected,and the main trunk of the left bundle branch was ablated to create an LBBB dog model. Electrocardiogram(ECG),transesophageal echocardiography and arterial blood pressure data of LBBB dogs were collected before and 12 months after the ablation of left bundle branch trunk. Global and segmental myocardial work parameters were obtained by left ventricular pressure-strain loop. The differences of above parameters between baseline and 12 months after the ablation of left bundle branch were compared. SPECT was performed in LBBB dogs 12 months after the creation of LBBB. The hearts were harvested for anatomy observation and histopathological analysis in LBBB dogs and another 7 male beagle dogs(normal control group)matched by age and weight. The correlation between myocardial perfusion(percentage of regional tracer uptake)and myocardial work parameters,myocardial fibrosis in LBBB dogs were analyzed.Results:Compared with baseline,the left ventricular end-diastolic volume of 12 months after the ablation increased[(20.78 ± 5.32)ml vs(26.71 ± 7.94)ml, P = 0.003],left ventricular ejection fraction decreased[(59.17 ± 5.67)% vs(47.69 ± 5.45)%, P<0.001];left ventricular global/segmental longitudinal strain,global/segmental constructive work and global/segmental work efficiency decreased(all P<0.05),left ventricular global/segmental wasted work increased(all P<0.001). Heterogenous perfusion defect was observed in LBBB dogs by SPECT,compared with lateral wall segments,the percentage of regional tracer uptake of septum was decreased(all P<0.05). Gross anatomical and myocardial pathological changes were manifested as cardiomegaly,flaky or focal grayish thickening of endocardium,cardiomyocyte degeneration and fibrosis. Compared with normal control group,the collagen fiber volume fraction(CVF)in all segmental endocardium and partial segmental myocardium of LBBB dogs were significantly increased(all P<0.05). Percentage of regional tracer uptake was positively correlated with segmental myocardial work(SMW)and segmental myocardial efficiency(SWE)( r s = 0.49,0.31;both P<0.001),and negatively correlated with CVF and segmental wasted work(SWW)( r s = -0.51,-0.49;both P<0.001). Conclusions:Isolated LBBB is not benign,which can result in left ventricular remodeling,decreased cardiac constructive function,abnormal myocardial perfusion,endocardial fibrosis and myocardial fibrosis.The parameters of myocardial work assecsed by echocardiograpgy and myocardial perfusion,as non-invasive examination,can to some extent reflect the degree of left ventricular remodeling in LBBB-CM.
2.Right heart contrast-enhanced echocardiographic diagnosis of a left superior vena cava aneurysm
Hui CHEN ; Aijuan FANG ; Ning ZHANG ; Guanjun GUO ; Lei LIU ; Jing YAO
Chinese Journal of Ultrasonography 2025;34(4):352-353
Permanent left superior vena cava aneurysm is a rare mediastinal venous lesion,the majority of the literature is in the form of case reports. In this article,a 50-year-old female with an incidental permanent left superior vena cava aneurysm discovered on echocardiography in Nanjing Gulou Hospital,and the right heart contrast-enhanced echocardiographic played an important role in the process of clear diagnosis. The patient was observed without intervention. No complications were attributable to the permanent left superior vena cava aneurysm during follow-up.
3.Preliminary study on the construction of an echocardiogram image quality control system based on artificial intelligence
Zhanru QI ; Hanlin CHENG ; Chunjie SHAN ; Ruiyang CHEN ; Hexiang WENG ; Yue DU ; Guanjun GUO ; Xiaoxian WANG ; Jing YAO ; Shouhua LUO ; Aijuan FANG ; Hui CHEN ; Zhongqing SHI
Chinese Journal of Ultrasonography 2025;34(2):107-113
Object:To explore the feasibility of using artificial intelligence for quality control of echocardiographic images.Methods:Retrospectively,5 000 two-dimensional echocardiographic video images within the period from 2021 to 2023 were randomly retrieved from the echocardiography database of Nanjing Drum Tower Hospital,Affiliated Hospital of Medical School,Nanjing University. Among these selected images,1 559 of them were apical views. The physician team formulated the scoring rules,which specifically included four scoring criteria:gain,scaling ratio,cardiac axis angle,and structure. Subsequently,the data were labeled with view classification and image quality scores. The labeled data were further partitioned into the training set( n = 643),the validation set( n = 276),and the test set( n = 640). The training and validation sets were utilized for constructing the models for view classification and quality assessment,while the test set was employed to verify the models' effectiveness. The view classification module was implemented using the SlowFast model,and the quality assessment module involved algorithms such as ResNet,Video Swin Transformer,SSD,and U-Net. Results:The average accuracy,precision,recall rate and F1 score of the classification model in identifying each apical view were 0.987 1,0.983 0,0.987 1 and 0.984 9 respectively,and the inference time was(333.4 ± 105.4)ms. The average accuracies of the quality assessment module in terms of gain,scaling ratio,cardiac axis angle and display of main structures were 0.915 1,0.928 2,0.938 7 and 0.965 6 respectively,and the overall scoring accuracy was 0.912 7.Conclusions:The echocardiogram quality control system developed in this research can effectively classify and evaluate the quality of two-dimensional images of the apical views in echocardiograms. Moreover,it guarantees the objectivity,timeliness and high-efficiency of quality control,which has reference value for the establishment of the echocardiogram quality control system.
4.Preliminary study on the construction of an echocardiogram image quality control system based on artificial intelligence
Zhanru QI ; Hanlin CHENG ; Chunjie SHAN ; Ruiyang CHEN ; Hexiang WENG ; Yue DU ; Guanjun GUO ; Xiaoxian WANG ; Jing YAO ; Shouhua LUO ; Aijuan FANG ; Hui CHEN ; Zhongqing SHI
Chinese Journal of Ultrasonography 2025;34(2):107-113
Object:To explore the feasibility of using artificial intelligence for quality control of echocardiographic images.Methods:Retrospectively,5 000 two-dimensional echocardiographic video images within the period from 2021 to 2023 were randomly retrieved from the echocardiography database of Nanjing Drum Tower Hospital,Affiliated Hospital of Medical School,Nanjing University. Among these selected images,1 559 of them were apical views. The physician team formulated the scoring rules,which specifically included four scoring criteria:gain,scaling ratio,cardiac axis angle,and structure. Subsequently,the data were labeled with view classification and image quality scores. The labeled data were further partitioned into the training set( n = 643),the validation set( n = 276),and the test set( n = 640). The training and validation sets were utilized for constructing the models for view classification and quality assessment,while the test set was employed to verify the models' effectiveness. The view classification module was implemented using the SlowFast model,and the quality assessment module involved algorithms such as ResNet,Video Swin Transformer,SSD,and U-Net. Results:The average accuracy,precision,recall rate and F1 score of the classification model in identifying each apical view were 0.987 1,0.983 0,0.987 1 and 0.984 9 respectively,and the inference time was(333.4 ± 105.4)ms. The average accuracies of the quality assessment module in terms of gain,scaling ratio,cardiac axis angle and display of main structures were 0.915 1,0.928 2,0.938 7 and 0.965 6 respectively,and the overall scoring accuracy was 0.912 7.Conclusions:The echocardiogram quality control system developed in this research can effectively classify and evaluate the quality of two-dimensional images of the apical views in echocardiograms. Moreover,it guarantees the objectivity,timeliness and high-efficiency of quality control,which has reference value for the establishment of the echocardiogram quality control system.
5.Quantitative evaluation of left ventricular remodeling in left bundle branch block induced cardiomyopathy by multimodal imaging
Xiaoxian WANG ; Changqing MIAO ; Beibei GE ; Mingxia LI ; Fen CHEN ; Fang XU ; Ning ZHANG ; Guanjun GUO ; Wei XU ; Wenzhi SHEN ; Yingming ZHAO ; Jing YAO
Chinese Journal of Ultrasonography 2025;34(1):26-32
Objective:To quantitatively evaluate the effects of left bundle branch block(LBBB)on left ventricular structure,function and myocardial perfusion using left ventricular pressure-strain loop and single photon emission computed tomography(SPECT),and to investigate the relationship between myocardial work,myocardial perfusion and pathological changes of left ventricular remodeling in left bundle branch block induced cardiomyopathy(LBBB-CM).Methods:Fourteen male beagle dogs were selected,and the main trunk of the left bundle branch was ablated to create an LBBB dog model. Electrocardiogram(ECG),transesophageal echocardiography and arterial blood pressure data of LBBB dogs were collected before and 12 months after the ablation of left bundle branch trunk. Global and segmental myocardial work parameters were obtained by left ventricular pressure-strain loop. The differences of above parameters between baseline and 12 months after the ablation of left bundle branch were compared. SPECT was performed in LBBB dogs 12 months after the creation of LBBB. The hearts were harvested for anatomy observation and histopathological analysis in LBBB dogs and another 7 male beagle dogs(normal control group)matched by age and weight. The correlation between myocardial perfusion(percentage of regional tracer uptake)and myocardial work parameters,myocardial fibrosis in LBBB dogs were analyzed.Results:Compared with baseline,the left ventricular end-diastolic volume of 12 months after the ablation increased[(20.78 ± 5.32)ml vs(26.71 ± 7.94)ml, P = 0.003],left ventricular ejection fraction decreased[(59.17 ± 5.67)% vs(47.69 ± 5.45)%, P<0.001];left ventricular global/segmental longitudinal strain,global/segmental constructive work and global/segmental work efficiency decreased(all P<0.05),left ventricular global/segmental wasted work increased(all P<0.001). Heterogenous perfusion defect was observed in LBBB dogs by SPECT,compared with lateral wall segments,the percentage of regional tracer uptake of septum was decreased(all P<0.05). Gross anatomical and myocardial pathological changes were manifested as cardiomegaly,flaky or focal grayish thickening of endocardium,cardiomyocyte degeneration and fibrosis. Compared with normal control group,the collagen fiber volume fraction(CVF)in all segmental endocardium and partial segmental myocardium of LBBB dogs were significantly increased(all P<0.05). Percentage of regional tracer uptake was positively correlated with segmental myocardial work(SMW)and segmental myocardial efficiency(SWE)( r s = 0.49,0.31;both P<0.001),and negatively correlated with CVF and segmental wasted work(SWW)( r s = -0.51,-0.49;both P<0.001). Conclusions:Isolated LBBB is not benign,which can result in left ventricular remodeling,decreased cardiac constructive function,abnormal myocardial perfusion,endocardial fibrosis and myocardial fibrosis.The parameters of myocardial work assecsed by echocardiograpgy and myocardial perfusion,as non-invasive examination,can to some extent reflect the degree of left ventricular remodeling in LBBB-CM.
6.Right heart contrast-enhanced echocardiographic diagnosis of a left superior vena cava aneurysm
Hui CHEN ; Aijuan FANG ; Ning ZHANG ; Guanjun GUO ; Lei LIU ; Jing YAO
Chinese Journal of Ultrasonography 2025;34(4):352-353
Permanent left superior vena cava aneurysm is a rare mediastinal venous lesion,the majority of the literature is in the form of case reports. In this article,a 50-year-old female with an incidental permanent left superior vena cava aneurysm discovered on echocardiography in Nanjing Gulou Hospital,and the right heart contrast-enhanced echocardiographic played an important role in the process of clear diagnosis. The patient was observed without intervention. No complications were attributable to the permanent left superior vena cava aneurysm during follow-up.
7.Effect of LncRNA SNHG1 on homocysteine-induced podocytespyrophosis
Zhenghao ZHANG ; Fang MA ; Qing ZHANG ; Tongtong XIA ; Honglin LIU ; Zhigang BAI ; Guanjun LU ; Jingwen ZHANG ; Hongjian PENG ; Yideng JIANG ; Shengchao MA
The Journal of Practical Medicine 2024;40(4):476-482
Objective To investigate the role of lncRNA SNHG1 in homocysteine-induced pyroptosis of podocyte.Methods Cbs+/-mice were randomly divided into two groups:a normal diet group(ND)and a high me-thionine diet group(HMD).Western blotting was used to detect the protein expression levels of Caspase-1,Cleaved Caspase-1,and NLRP3.Mouse renal glomerular podocytes were cultured in vitro,and then assigned into a control group(Control,0 μmol/L Hcy)and a homocysteine intervention group(Hcy,80 μmol/L Hcy).Western blotting was used to detect the protein expression levels of Caspase-1,Cleaved Caspase-1,and NLRP3.Mouse renal glomerular podocyion group(OE-NC + Hcy)and the lncSNHG1 overexpression + homocysteine intervention group(OE-SNHG1 + Hcy)were also established.After 48 hours of intervention,Real-time fluorescence quantita-tive PCR was used to detect the expression of lncSNHG1 in podocytes after Hcy intervention.Western blot was used to detect the expressions of Caspase-1,Cleaved Caspase-3 and NLRP3.Immunofluorescence was used to de-tect the expression levels of GSDMD and GSDMD-N.ELISA was used to detect the contents of IL-1β and IL-18.Results(1)In the animal experiments,the expression levels of pyroptosis-related proteins Caspase-1,Cleaved Caspase-1,NLRP3,GSDMD,and GSDMD-N were all increased in the HMD group compared with the ND group.(2)In the cellular experiments,the expression levels of Caspase-1,Cleaved Caspase-1,NLRP3,GSDMD,and GSDMD-N were all increased in the Hcy group compared with the Control group,and the contents of pyroptosis-mediated inflammatory factors IL-1β and IL-18 were increased as well.(3)In the cellular experiments,the expres-sion of lncSNHG1 was increased in the Hcy group compared with the control group.After transduction with lnc-SNHG1 lentivirus,the expression of lncSNHG1 was increased in the OE-SNHG1 group,compared with the control group and the OE-NC group.(4)In the cellular experiments,the expressions of pyroptosis-related proteins Cas-pase-1,Cleaved Caspase-1,NLRP3,GSDMD,and GSDMD-N were increased compared with the OE-NC+Hcy group,and the contents of pyroptosis-mediated inflammatory factors IL-1β and IL-18 were increased in the OE-SNHG1+Hcy group.Conclusion These results indicate that lncSNHG1 may play a role in promoting Hcy induced podocytepyroptosis.
8.Deep learning models semi-automatic training system for quality control of transthoracic echocardiography
Sunnan QIAN ; Hexiang WENG ; Hanlin CHENG ; Zhongqing SHI ; Xiaoxian WANG ; Guanjun GUO ; Aijuan FANG ; Shouhua LUO ; Jing YAO ; Zhanru QI
Chinese Journal of Medical Imaging Technology 2024;40(8):1140-1145
Objective To explore the value of deep learning(DL)models semi-automatic training system for automatic optimization of clinical image quality control of transthoracic echocardiography(TTE).Methods Totally 1 250 TTE videos from 402 patients were retrospectively collected,including 490 apical four chamber(A4C),310 parasternal long axis view of left ventricle(PLAX)and 450 parasternal short axis view of great vessel(PSAXGv).The videos were divided into development set(245 A4C,155 PLAX,225 PSAXGV),semi-automated training set(98 A4C,62 PLAX,90 PSAXGV)and test set(147 A4C,93 PLAX,135 PSAXGV)at the ratio of 5:2:3.Based on development set and semi-automatic training set,DL model of quality control was semi-automatically iteratively optimized,and a semi-automatic training system was constructed,then the efficacy of DL models for recognizing TTE views and assessing imaging quality of TTE were verified in test set.Results After optimization,the overall accuracy,precision,recall,and F1 score of DL models for recognizing TTE views in test set improved from 97.33%,97.26%,97.26%and 97.26%to 99.73%,99.65%,99.77%and 99.71%,respectively,while the overall accuracy for assessing A4C,PLAX and PSAXGV TTE as standard views in test set improved from 89.12%,83.87%and 90.37%to 93.20%,90.32%and 93.33%,respectively.Conclusion The developed DL models semi-automatic training system could improve the efficiency of clinical imaging quality control of TTE and increase iteration speed.
9.Mises stress analysis of 42A2 type tibial mid segment oblique fracture fixed with external locking plate at different angles
Yunqi YANG ; Xiaoye WANG ; Lei MI ; Guanjun ZHANG ; Ling ZHANG ; Shitao FANG ; Yun WANG
Journal of Chinese Physician 2023;25(5):700-703,708
Objective:To establish a three-dimensional model of locking plate fixation for 42A2 type oblique tibial fractures with different fracture line directions and different angles between the fracture line and the long axis of the tibia. Finite element analysis was used to calculate and analyze the biomechanics of locking plate, screw, and tibia, providing theoretical basis for clinical application.Methods:A healthy adult volunteer, 25 years old, male, with a height of 173 cm and a weight of 69.5 kg, was selected to perform computed tomography (CT) scans on the left tibia. Relevant data were obtained to establish a locking steel plate fixation model for 42A2 type tibia with different oblique fracture line directions and different angles between the fracture line and the long axis of the tibia. Eight hole pure titanium plates were used for fixation, respectively. We compared the Mises stress changes of locking plates, screws, and tibia in different angle fracture models.Results:In the case of a 42A2 type fracture in the left oblique direction with a fracture line from outside to inside, the maximum Mises stress in the tibia was 114 MPa, the maximum Mises stress in the screw was 279.8 MPa, and the maximum Mises stress in the locking steel plate was 302.4 MPa; In the case of a 42A2 type fracture in the right oblique fracture with a fracture line from the bottom to the top, the maximum Mises stress of the tibia was 93.41MPa, the maximum Mises stress of the screw was 353.4 MPa, and the maximum Mises stress of the locking steel plate was 411.8 MPa.Conclusions:Regardless of the oblique fractures in both left and right directions, the maximum stress values are: locking plate>screw>tibia; When the position of the locking steel plate is fixed, the maximum stress values of the locking steel plate and screw are both right oblique fracture>left oblique fracture; And the maximum stress values all increase with the increase of angle.
10.A case of ductus arteriosus occluder displacement
Quanpeng WANG ; Aijuan FANG ; Guanjun GUO ; Jun WANG
Chinese Journal of Cardiology 2019;47(6):492-493

Result Analysis
Print
Save
E-mail