1.Compact Fundus Imaging System Using Shack-Hartmann Wavefront Sensing for High-speed Auto-focus
Zhe-Kai LIN ; Long CHEN ; Geng-Yong ZHENG ; Jin-Tian HUANG ; Jia-Xin DONG ; Shang-Pan YANG ; Wen-Zheng DING ; Ding-An HAN ; Xue-Hua WANG ; Ya-Guang ZENG
Progress in Biochemistry and Biophysics 2026;53(4):1076-1086
ObjectiveThe widespread adoption of portable fundus cameras for primary care and community screening is hindered by limitations in current autofocus(AF) technologies. Image-based methods relying on sharpness evaluation require iterative searches, resulting in slow convergence, while projection-based techniques are susceptible to optical artifacts and calibration errors. To address these challenges, this study introduces a novel AF system based on direct wavefront sensing, designed to deliver simultaneous high speed, high precision, and operational robustness within the compact form factor essential for portable ophthalmic devices. MethodsOur approach fundamentally reimagines the AF process by directly measuring the ocular wavefront aberration. We developed a custom portable fundus camera integrating a miniaturized Shack-Hartmann wavefront sensor (SHWS) into the optical path. An 850 nm laser diode projects a point source onto the retina via oblique illumination to minimize corneal reflections. Light scattered from this spot carries the eye’s refractive error through the imaging optics and is directed to the SHWS, positioned at a plane optically conjugate to the primary color CMOS imaging sensor. A microlens array within the SHWS samples the incident wavefront, generating a pattern of focal spots on a CCD. Real-time centroid analysis of these spots provides a map of local wavefront slopes. These measurements are processed through a singular value decomposition (SVD) algorithm to fit a Zernike polynomial basis set, enabling real-time reconstruction of the wavefront phase. The defocus component (S) is extracted from the second-order Zernike coefficients, providing a direct, quantitative measure of the refractive error in diopters. This value serves as a precise error signal in a closed-loop control system, which commands a voice-coil actuated focusing lens to its null position in a single, deterministic step, eliminating the need for iterative search algorithms. ResultsComprehensive evaluation demonstrated the system’s high performance. Testing on a calibrated model eye (OEMI-7) established a highly linear relationship between the computed defocus S and the focusing lens position across a ±20 Diopter (D) compensation range, achievable within a 5 mm mechanical travel. The system achieved a focusing precision of 0.08 D, corresponding to an 18-fold improvement over a conventional projection spot-size method tested under identical conditions. The total focus acquisition time, encompassing wavefront measurement, computation, and lens actuation, averaged under 0.5 s. Clinical validation with 25 human volunteers (50 eyes, refractive range -15 D to +10 D) confirmed practical efficacy. The wavefront-sensing AF succeeded in 92% of attempts with a mean time of 0.5 s, substantially outperforming a projection-based benchmark which achieved only a 32% success rate with an average time of 4.25 s. The system provided instantaneous directional guidance and maintained stability during minor ocular movements. Objective assessment of image quality, via amplitude contrast of retinal vasculature, showed consistent and significant enhancement following AF correction across the entire tested diopter range. ConclusionThis work successfully implements and validates a direct wavefront-sensing autofocus paradigm for portable fundus cameras. By directly quantifying and compensating for the optical defocus aberration, this method bypasses the fundamental limitations of image-processing and projection-based techniques, enabling rapid, precise, and deterministic diopter compensation. The developed system delivers an exceptional combination of a wide operational range (±20 D), high accuracy (0.08 D), fast convergence (0.5 s), and a compact physical footprint. This technology provides a practical and high-performance focusing solution capable of enhancing the reliability, throughput, and diagnostic utility of portable retinal imaging in large-scale screening applications. Future efforts will be directed towards system cost optimization and performance adaptation for diverse ocular conditions.
2.Observation on the therapeutic effect of a modified Devine procedure with subcutaneous sliding fixation method for concealed penis.
Mohammed Abdulkarem AL-QAISI ; Hai-Fu TIAN ; Jia-Jin FENG ; Ke-Ming CHEN ; Jin ZHANG ; Yun-Shang TUO ; Xue-Hao WANG ; Bin-Cheng HUANG ; Muhammad Arslan Ul HASSAN ; Rui HE ; Guang-Yong LI
Asian Journal of Andrology 2025;27(4):470-474
To evaluate the therapeutic effect of a modified Devine procedure with a subcutaneous sliding fixation method for the treatment of congenital concealed penis, we retrospectively selected 45 patients with congenital concealed penises who were admitted to General Hospital of Ningxia Medical University (Yinchuan, China) between September 2020 and November 2023. In all cases, the penis was observed to be short, and retracting the skin at the base revealed a normal penile body, which immediately returned to its original position upon release. All patients underwent the modified Devine procedure with subcutaneous sliding fixation and completed a 12-week postoperative follow-up. A statistically significant increase in penile length was observed postoperatively, with the median length increasing from 4.0 (interquartile range [IQR]: 3.5-4.8; 95% confidence interval [CI]: 3.9-4.4) cm to 8.0 (IQR: 7.8-8.0; 95% CI: 7.7-7.9) cm, with P < 0.001. The parents were satisfied with the outcomes, including increased penile length, improved hygiene, and enhanced esthetics. Except for mild foreskin edema in all cases, no complications (such as infections, skin necrosis, or penile retraction) were observed. The edema was resolved within 4 weeks after the operation. This study demonstrates that the modified Devine procedure utilizing the subcutaneous sliding fixation method yields excellent outcomes with minimal postoperative complications, reduced penile retraction, and high satisfaction rates among patients and their families.
Humans
;
Male
;
Penis/abnormalities*
;
Retrospective Studies
;
Urologic Surgical Procedures, Male/methods*
;
Treatment Outcome
;
Child
;
Plastic Surgery Procedures/methods*
3.Expert consensus on visualized tele-round and quality control management based on the improvement of clinical practice ability
Wanhong YIN ; Xiaoting WANG ; Ran ZHOU ; Dawei LIU ; Yan KANG ; Yaoqing TANG ; Xiaochun MA ; Jianguo LI ; Zhenjie HU ; Haitao ZHANG ; Wei HE ; Lixia LIU ; Wenjin CHEN ; Ran ZHU ; Jun WU ; Hongmin ZHANG ; Lina ZHANG ; Wenzhao CHAI ; Shihong ZHU ; Wangbin XU ; Rongqing SUN ; Xiangyou YU ; Tianjiao SONG ; Ying ZHU ; Hong REN ; Ai SHANMU ; Qing ZHANG ; Wei FANG ; Xiuling SHANG ; Liwen LYU ; Shuhan CAI ; Xin DING ; Heng ZHANG ; Guang FENG ; Lipeng ZHANG ; Bo HU ; Dong ZHANG ; Weidong WU ; Feng SHEN ; Xiaojun YANG ; Zhenguo ZENG ; Qibing HUANG ; Xueying ZENG ; Tongjuan ZOU ; Milin PENG ; Yulong YAO ; Mingming CHEN ; Hui LIAN ; Jingmei WANG ; Yong LI ; Feng QU ; Gang YE ; Rongli YANG ; Xiukai CHEN ; Suwei LI ; Juxiang WANG ; Yangong CHAO
Chinese Journal of Internal Medicine 2025;64(2):101-109
Turning to critical illness is a common stage of various diseases and injuries before death. Patients usually have complex health conditions, while the treatment process involves a wide range of content, along with high requirements for doctor′s professionalism and multi-specialty teamwork, as well as a great demand for time-sensitive treatments. However, this is not matched with critical care professionals and the current state of medical care in China. Telemedicine, which shortens the distance of medical professionals and the gap of disease diagnosis and treatments in various regions through electronic information, can effectively solve the current problem. Therefore, there is an urgent need to develop a standardized, high-quality visualization telemedicine round system .Therefore, experts have been organized to search domestic and foreign literature on telemedicine round for critically ill patients and to form this consensus based on clinical experiences so as to further improve the level of critical care treatments in regions.
4.Expert consensus on visualized tele-round and quality control management based on the improvement of clinical practice ability
Wanhong YIN ; Xiaoting WANG ; Ran ZHOU ; Dawei LIU ; Yan KANG ; Yaoqing TANG ; Xiaochun MA ; Jianguo LI ; Zhenjie HU ; Haitao ZHANG ; Wei HE ; Lixia LIU ; Wenjin CHEN ; Ran ZHU ; Jun WU ; Hongmin ZHANG ; Lina ZHANG ; Wenzhao CHAI ; Shihong ZHU ; Wangbin XU ; Rongqing SUN ; Xiangyou YU ; Tianjiao SONG ; Ying ZHU ; Hong REN ; Ai SHANMU ; Qing ZHANG ; Wei FANG ; Xiuling SHANG ; Liwen LYU ; Shuhan CAI ; Xin DING ; Heng ZHANG ; Guang FENG ; Lipeng ZHANG ; Bo HU ; Dong ZHANG ; Weidong WU ; Feng SHEN ; Xiaojun YANG ; Zhenguo ZENG ; Qibing HUANG ; Xueying ZENG ; Tongjuan ZOU ; Milin PENG ; Yulong YAO ; Mingming CHEN ; Hui LIAN ; Jingmei WANG ; Yong LI ; Feng QU ; Gang YE ; Rongli YANG ; Xiukai CHEN ; Suwei LI ; Juxiang WANG ; Yangong CHAO
Chinese Journal of Internal Medicine 2025;64(2):101-109
Turning to critical illness is a common stage of various diseases and injuries before death. Patients usually have complex health conditions, while the treatment process involves a wide range of content, along with high requirements for doctor′s professionalism and multi-specialty teamwork, as well as a great demand for time-sensitive treatments. However, this is not matched with critical care professionals and the current state of medical care in China. Telemedicine, which shortens the distance of medical professionals and the gap of disease diagnosis and treatments in various regions through electronic information, can effectively solve the current problem. Therefore, there is an urgent need to develop a standardized, high-quality visualization telemedicine round system .Therefore, experts have been organized to search domestic and foreign literature on telemedicine round for critically ill patients and to form this consensus based on clinical experiences so as to further improve the level of critical care treatments in regions.
5.Clinical efficacy and safety of a domestic calcipotriol/betamethasone dipropionate ointment in the treatment of stable plaque psoriasis: a multicenter, randomized, double-blind, controlled study
Lixin XIA ; Guang XIANG ; Qingchun DIAO ; Kun HUANG ; Shoumin ZHANG ; Shanshan LI ; Yumei LI ; Zhiqiang SONG ; Qing SUN ; Xiumin YANG ; Meng PAN ; Yuling SHI ; Shuping GUO ; Huiping WANG ; Tiechi LEI ; Xiaoyong ZHOU ; Songmei GENG ; Suchun HOU ; Juan SU ; Yong CUI ; Rixin CHEN ; Yanyan FENG ; Hongxia FENG ; Rushan XIA ; Zudong MENG ; Fang YIN ; Jingjing WANG ; Xinghua GAO
Chinese Journal of Dermatology 2025;58(11):1020-1026
Objective:To evaluate the clinical equivalence between a domestic calcipotriol/betamethasone dipropionate ointment and the originator product in the treatment of stable plaque psoriasis.Methods:A multicenter, randomized, double-blind, three-arm, parallel-group, active- and placebo-controlled study was conducted, and 449 patients aged 18 - 65 years with stable plaque psoriasis were enrolled from 25 hospitals (such as the First Affiliated Hospital of China Medical University). Eligible patients had a baseline physician's global assessment (PGA) score of ≥ 3 points, baseline body surface area (BSA) involvement of 5% - 30%, and a target lesion psoriasis area and severity index (TL-PASI) for plaque elevation of ≥ 3 points. Participants were randomly assigned in a 2:2:1 ratio to the test group ( n = 179), reference group ( n = 180), and placebo group ( n = 90), and applied the domestic calcipotriol/betamethasone dipropionate ointment, originator product, and ointment base respectively, once daily in the evening for 4 weeks. Efficacy and safety were assessed at weeks 1, 2, and 4. The primary efficacy endpoints were the treatment success rates and clinical success rates in each group at week 4. The per-protocol set (PPS) was used for the primary efficacy analysis, and the intention-to-treat (ITT) set for supplementary efficacy analysis. Equivalence between the test and reference preparations was tested using the Cochran-Mantel-Haenszel method adjusted for randomization strata. Superiority of the test and reference preparations over the placebo was also tested. Measurement data were compared among the 3 groups using analysis of variance or non-parametric tests, while treatment success rates, clinical success rates, and incidence rates of adverse reactions were compared using the chi-square test. Results:The ITT, PPS, and safety sets included 447, 420, and 448 patients, respectively. In the ITT set, patients were aged 43.6 ± 12.8 years, including 320 (71.6%) males and 127 (28.4%) females, and the disease duration was 11.21 ± 9.05 years; 316 (70.7%) had a PGA score of 3 points and 131 (29.3%) had a PGA score of 4 - 5 points. No significant differences in the baseline characteristics (including age, sex, disease duration and disease severity) were observed among the 3 groups (all P > 0.05). Based on the PPS analysis, the treatment success rates were 57.9% (99/171) in the test group, 50.3% (86/171) in the reference group, and 7.7% (6/78) in the placebo group, and the clinical success rates were 57.9% (99/171), 50.3% (86/171), and 10.3% (8/78), respectively; both the test and reference groups were superior to the placebo group in both treatment and clinical success rates (all P < 0.001) ; the rate differences for treatment success (90% confidence interval [ CI]: -1.3% - 16.4%) and clinical success (90% CI: -1.3% - 16.3%) between the test and reference groups were entirely within the pre-defined equivalence margin (-20% - 20%). Subgroup analyses by baseline PGA scores: for patients with a baseline PGA score of 3 points, the treatment success rates in the test, reference, and placebo groups were 60.8% (73/120), 52.1% (62/119), and 11.1% (6/54), respectively, and the corresponding clinical success rates were 61.7% (74/120), 53.8% (64/119), and 13% (7/54), respectively; the test and reference groups did not differ significantly in treatment or clinical success rates (both P > 0.05), but both showed higher success rates than the placebo group (all P < 0.001) ; the results of statistical comparisons among the 3 groups in patients with a baseline PGA score of 4 - 5 points were consistent with those observed in patients with a baseline PGA score of 3 points. The percentage reductions in PGA and TL-PASI scores from baseline to weeks 1, 2, and 4 showed significant differences among the 3 groups, which were significantly higher in the test and reference groups than in the placebo group (all P < 0.001), but did not differ between the test and reference groups (all P > 0.05). The primary adverse reactions were local skin reactions, such as pruritus, pain, and erythema. The incidence rates of adverse reactions were 8.9% (16/179) in the test group, 7.3% (13/179) in the reference group, and 7.8% (7/90) in the placebo group, with no significant difference among the 3 groups ( P > 0.05) . Conclusions:The domestic calcipotriol/betamethasone dipropionate ointment demonstrated clinical equivalence to the originator product in the treatment of stable plaque psoriasis, and the two agents exhibited comparable efficacy for patients with varying degrees of disease severity, and were comparable in the speed and degree of clinical improvement, with similar favorable safety profiles.
6.Clinical efficacy and safety of a domestic calcipotriol/betamethasone dipropionate ointment in the treatment of stable plaque psoriasis: a multicenter, randomized, double-blind, controlled study
Lixin XIA ; Guang XIANG ; Qingchun DIAO ; Kun HUANG ; Shoumin ZHANG ; Shanshan LI ; Yumei LI ; Zhiqiang SONG ; Qing SUN ; Xiumin YANG ; Meng PAN ; Yuling SHI ; Shuping GUO ; Huiping WANG ; Tiechi LEI ; Xiaoyong ZHOU ; Songmei GENG ; Suchun HOU ; Juan SU ; Yong CUI ; Rixin CHEN ; Yanyan FENG ; Hongxia FENG ; Rushan XIA ; Zudong MENG ; Fang YIN ; Jingjing WANG ; Xinghua GAO
Chinese Journal of Dermatology 2025;58(11):1020-1026
Objective:To evaluate the clinical equivalence between a domestic calcipotriol/betamethasone dipropionate ointment and the originator product in the treatment of stable plaque psoriasis.Methods:A multicenter, randomized, double-blind, three-arm, parallel-group, active- and placebo-controlled study was conducted, and 449 patients aged 18 - 65 years with stable plaque psoriasis were enrolled from 25 hospitals (such as the First Affiliated Hospital of China Medical University). Eligible patients had a baseline physician's global assessment (PGA) score of ≥ 3 points, baseline body surface area (BSA) involvement of 5% - 30%, and a target lesion psoriasis area and severity index (TL-PASI) for plaque elevation of ≥ 3 points. Participants were randomly assigned in a 2:2:1 ratio to the test group ( n = 179), reference group ( n = 180), and placebo group ( n = 90), and applied the domestic calcipotriol/betamethasone dipropionate ointment, originator product, and ointment base respectively, once daily in the evening for 4 weeks. Efficacy and safety were assessed at weeks 1, 2, and 4. The primary efficacy endpoints were the treatment success rates and clinical success rates in each group at week 4. The per-protocol set (PPS) was used for the primary efficacy analysis, and the intention-to-treat (ITT) set for supplementary efficacy analysis. Equivalence between the test and reference preparations was tested using the Cochran-Mantel-Haenszel method adjusted for randomization strata. Superiority of the test and reference preparations over the placebo was also tested. Measurement data were compared among the 3 groups using analysis of variance or non-parametric tests, while treatment success rates, clinical success rates, and incidence rates of adverse reactions were compared using the chi-square test. Results:The ITT, PPS, and safety sets included 447, 420, and 448 patients, respectively. In the ITT set, patients were aged 43.6 ± 12.8 years, including 320 (71.6%) males and 127 (28.4%) females, and the disease duration was 11.21 ± 9.05 years; 316 (70.7%) had a PGA score of 3 points and 131 (29.3%) had a PGA score of 4 - 5 points. No significant differences in the baseline characteristics (including age, sex, disease duration and disease severity) were observed among the 3 groups (all P > 0.05). Based on the PPS analysis, the treatment success rates were 57.9% (99/171) in the test group, 50.3% (86/171) in the reference group, and 7.7% (6/78) in the placebo group, and the clinical success rates were 57.9% (99/171), 50.3% (86/171), and 10.3% (8/78), respectively; both the test and reference groups were superior to the placebo group in both treatment and clinical success rates (all P < 0.001) ; the rate differences for treatment success (90% confidence interval [ CI]: -1.3% - 16.4%) and clinical success (90% CI: -1.3% - 16.3%) between the test and reference groups were entirely within the pre-defined equivalence margin (-20% - 20%). Subgroup analyses by baseline PGA scores: for patients with a baseline PGA score of 3 points, the treatment success rates in the test, reference, and placebo groups were 60.8% (73/120), 52.1% (62/119), and 11.1% (6/54), respectively, and the corresponding clinical success rates were 61.7% (74/120), 53.8% (64/119), and 13% (7/54), respectively; the test and reference groups did not differ significantly in treatment or clinical success rates (both P > 0.05), but both showed higher success rates than the placebo group (all P < 0.001) ; the results of statistical comparisons among the 3 groups in patients with a baseline PGA score of 4 - 5 points were consistent with those observed in patients with a baseline PGA score of 3 points. The percentage reductions in PGA and TL-PASI scores from baseline to weeks 1, 2, and 4 showed significant differences among the 3 groups, which were significantly higher in the test and reference groups than in the placebo group (all P < 0.001), but did not differ between the test and reference groups (all P > 0.05). The primary adverse reactions were local skin reactions, such as pruritus, pain, and erythema. The incidence rates of adverse reactions were 8.9% (16/179) in the test group, 7.3% (13/179) in the reference group, and 7.8% (7/90) in the placebo group, with no significant difference among the 3 groups ( P > 0.05) . Conclusions:The domestic calcipotriol/betamethasone dipropionate ointment demonstrated clinical equivalence to the originator product in the treatment of stable plaque psoriasis, and the two agents exhibited comparable efficacy for patients with varying degrees of disease severity, and were comparable in the speed and degree of clinical improvement, with similar favorable safety profiles.
7.Efficacy and safety of recombinant human anti-SARS-CoV-2 monoclonal antibody injection(F61 injection)in the treatment of patients with COVID-19 combined with renal damage:a randomized controlled exploratory clinical study
Ding-Hua CHEN ; Chao-Fan LI ; Yue NIU ; Li ZHANG ; Yong WANG ; Zhe FENG ; Han-Yu ZHU ; Jian-Hui ZHOU ; Zhe-Yi DONG ; Shu-Wei DUAN ; Hong WANG ; Meng-Jie HUANG ; Yuan-Da WANG ; Shuo-Yuan CONG ; Sai PAN ; Jing ZHOU ; Xue-Feng SUN ; Guang-Yan CAI ; Ping LI ; Xiang-Mei CHEN
Chinese Journal of Infection Control 2024;23(3):257-264
Objective To explore the efficacy and safety of recombinant human anti-severe acute respiratory syn-drome coronavirus 2(anti-SARS-CoV-2)monoclonal antibody injection(F61 injection)in the treatment of patients with coronavirus disease 2019(COVID-19)combined with renal damage.Methods Patients with COVID-19 and renal damage who visited the PLA General Hospital from January to February 2023 were selected.Subjects were randomly divided into two groups.Control group was treated with conventional anti-COVID-19 therapy,while trial group was treated with conventional anti-COVID-19 therapy combined with F61 injection.A 15-day follow-up was conducted after drug administration.Clinical symptoms,laboratory tests,electrocardiogram,and chest CT of pa-tients were performed to analyze the efficacy and safety of F61 injection.Results Twelve subjects(7 in trial group and 5 in control group)were included in study.Neither group had any clinical progression or death cases.The ave-rage time for negative conversion of nucleic acid of SARS-CoV-2 in control group and trial group were 3.2 days and 1.57 days(P=0.046),respectively.The scores of COVID-19 related target symptom in the trial group on the 3rd and 5th day after medication were both lower than those of the control group(both P<0.05).According to the clinical staging and World Health Organization 10-point graded disease progression scale,both groups of subjects improved but didn't show statistical differences(P>0.05).For safety,trial group didn't present any infusion-re-lated adverse event.Subjects in both groups demonstrated varying degrees of elevated blood glucose,elevated urine glucose,elevated urobilinogen,positive urine casts,and cardiac arrhythmia,but the differences were not statistica-lly significant(all P>0.05).Conclusion F61 injection has initially demonstrated safety and clinical benefit in trea-ting patients with COVID-19 combined with renal damage.As the domestically produced drug,it has good clinical accessibility and may provide more options for clinical practice.
8.Leukocyte cell-derived chemotaxin 2(LECT2)regulates liver ischemia-reperfusion injury
Dong MENG-QI ; Xie YUAN ; Tang ZHI-LIANG ; Zhao XUE-WEN ; Lin FU-ZHEN ; Zhang GUANG-YU ; Huang ZHI-HAO ; Liu ZHI-MIN ; Lin YUAN ; Liu FENG-YONG ; Zhou WEI-JIE
Liver Research 2024;8(3):165-171
Background and aim:Hepatic ischemia-reperfusion injury(IRI)is a significant challenge in liver trans-plantation,trauma,hypovolemic shock,and hepatectomy,with limited effective interventions available.This study aimed to investigate the role of leukocyte cell-derived chemotaxin 2(LECT2)in hepatic IRI and assess the therapeutic potential of Lect2-short hairpin RNA(shRNA)delivered through adeno-associated virus(AAV)vectors. Materials and methods:This study analyzed human liver and serum samples from five patients under-going the Pringle maneuver.Lect2-knockout and C57BL/6J mice were used.Hepatic IRI was induced by clamping the hepatic pedicle.Treatments included recombinant human LECT2(rLECT2)and AAV-Lect2-shRNA.LECT2 expression levels and serum biomarkers including alanine aminotransferase(ALT),aspartate aminotransferase(AST),creatinine,and blood urea nitrogen(BUN)were measured.Histological analysis of liver necrosis and quantitative reverse-transcription polymerase chain reaction were performed. Results:Serum and liver LECT2 levels were elevated during hepatic IRI.Serum LECT2 protein and mRNA levels increased post reperfusion.Lect2-knockout mice had reduced weight loss;hepatic necrosis;and serum ALT,AST,creatinine,and BUN levels.rLECT2 treatment exacerbated weight loss,hepatic necrosis,and serum biomarkers(ALT,AST,creatinine,and BUN).AAV-Lect2-shRNA treatment significantly reduced weight loss,hepatic necrosis,and serum biomarkers(ALT,AST,creatinine,and BUN),indicating thera-peutic potential. Conclusions:Elevated LECT2 levels during hepatic IRI increased liver damage.Genetic knockout or shRNA-mediated knockdown of Lect2 reduced liver damage,indicating its therapeutic potential.AAV-mediated Lect2-shRNA delivery mitigated hepatic IRI,offering a potential new treatment strategy to enhance clinical outcomes for patients undergoing liver-related surgeries or trauma.
9.Evaluation of performance of disposable medical protective clothing for resistance to infective agent penetration
Ke-Yang LIU ; Yan FENG ; Juan ZHANG ; Yue NIU ; Dan QIN ; Yong-Fu HUANG ; Guang-Yong HU
Chinese Medical Equipment Journal 2024;45(5):16-21
Objective To evaluate the performance of the disposable medical protective clothing in blocking the penetration of infectious agents,in order to provide data support for the setting of such performance indexes when the GB 19082 is revised.Methods Totally 10 batches of different brands and models of protective clothing were selected,and tests were carried out for penetration resistance to synthetic blood,phage,wet microorganisms,dry microorganisms and contaminated liquid aerosol and particle filtration efficiency according to YY/T 0700-2008,YY/T 0689-2008,YY/T 0506.6-2009,GB 19082-2009,YY/T 0506.5-2009 and YY/T 1799-2020.Results There were 2 batches of protective clothing with anti-synthetic blood penetration performance level 2,3,4,5 and 6,respectively;all the protective clothing had the highest level 6 for anti-wet microorganisms penetration,part of whom had the levels for the resistance to phage penetration lower than those for preventing anti-synthetic blood penetration;all of the protective clothing had the particle filtration efficiencies higher than 95%,and had the highest level 3 for anti-dry microorganisms penetration;there're 5 batches of protective clothing with the highest level 3 for contaminated liquid aerosol penetration,1 batch with level 2 and the remained 4 batches with undetermined levels,which all had an average logarithmic reduction higher than 4.5 after penetration.Conclusion Particle filtration efficiency and resistance to phage penetration may be involved in the requirements for resistance to infective agent penetration in revised GB 19082 for evaluating the ability of protective clothing materials to block microorganisms in airborne particles and liquid contaminants.[Chinese Medical Equipment Journal,2024,45(5):16-21]
10.Interpretation of YY 1881-2023 Powered air-purifying respirator(PAPR)used in healthcare settings
Ke-Yang LIU ; Yong-Fu HUANG ; Guang-Yong HU
Chinese Medical Equipment Journal 2024;45(8):1-6
The standard YY 1881-2023 Powered air-purifying respirator(PAPR)used in healthcare settings was introduced in terms of development background,foreign and China's standards involved in during its development and settings of related product performance indicators,which was interpreted from the aspects of scope of application,classificantion and marking of targeted products and main performance requirements.References were provided for correct understanding of the standard terms and product development,manufacturing,inspection and etc.[Chinese Medical Equipment Journal,2024,45(8):1-6]

Result Analysis
Print
Save
E-mail