1.Compact Fundus Imaging System Using Shack-Hartmann Wavefront Sensing for High-speed Auto-focus
Zhe-Kai LIN ; Long CHEN ; Geng-Yong ZHENG ; Jin-Tian HUANG ; Jia-Xin DONG ; Shang-Pan YANG ; Wen-Zheng DING ; Ding-An HAN ; Xue-Hua WANG ; Ya-Guang ZENG
Progress in Biochemistry and Biophysics 2026;53(4):1076-1086
ObjectiveThe widespread adoption of portable fundus cameras for primary care and community screening is hindered by limitations in current autofocus(AF) technologies. Image-based methods relying on sharpness evaluation require iterative searches, resulting in slow convergence, while projection-based techniques are susceptible to optical artifacts and calibration errors. To address these challenges, this study introduces a novel AF system based on direct wavefront sensing, designed to deliver simultaneous high speed, high precision, and operational robustness within the compact form factor essential for portable ophthalmic devices. MethodsOur approach fundamentally reimagines the AF process by directly measuring the ocular wavefront aberration. We developed a custom portable fundus camera integrating a miniaturized Shack-Hartmann wavefront sensor (SHWS) into the optical path. An 850 nm laser diode projects a point source onto the retina via oblique illumination to minimize corneal reflections. Light scattered from this spot carries the eye’s refractive error through the imaging optics and is directed to the SHWS, positioned at a plane optically conjugate to the primary color CMOS imaging sensor. A microlens array within the SHWS samples the incident wavefront, generating a pattern of focal spots on a CCD. Real-time centroid analysis of these spots provides a map of local wavefront slopes. These measurements are processed through a singular value decomposition (SVD) algorithm to fit a Zernike polynomial basis set, enabling real-time reconstruction of the wavefront phase. The defocus component (S) is extracted from the second-order Zernike coefficients, providing a direct, quantitative measure of the refractive error in diopters. This value serves as a precise error signal in a closed-loop control system, which commands a voice-coil actuated focusing lens to its null position in a single, deterministic step, eliminating the need for iterative search algorithms. ResultsComprehensive evaluation demonstrated the system’s high performance. Testing on a calibrated model eye (OEMI-7) established a highly linear relationship between the computed defocus S and the focusing lens position across a ±20 Diopter (D) compensation range, achievable within a 5 mm mechanical travel. The system achieved a focusing precision of 0.08 D, corresponding to an 18-fold improvement over a conventional projection spot-size method tested under identical conditions. The total focus acquisition time, encompassing wavefront measurement, computation, and lens actuation, averaged under 0.5 s. Clinical validation with 25 human volunteers (50 eyes, refractive range -15 D to +10 D) confirmed practical efficacy. The wavefront-sensing AF succeeded in 92% of attempts with a mean time of 0.5 s, substantially outperforming a projection-based benchmark which achieved only a 32% success rate with an average time of 4.25 s. The system provided instantaneous directional guidance and maintained stability during minor ocular movements. Objective assessment of image quality, via amplitude contrast of retinal vasculature, showed consistent and significant enhancement following AF correction across the entire tested diopter range. ConclusionThis work successfully implements and validates a direct wavefront-sensing autofocus paradigm for portable fundus cameras. By directly quantifying and compensating for the optical defocus aberration, this method bypasses the fundamental limitations of image-processing and projection-based techniques, enabling rapid, precise, and deterministic diopter compensation. The developed system delivers an exceptional combination of a wide operational range (±20 D), high accuracy (0.08 D), fast convergence (0.5 s), and a compact physical footprint. This technology provides a practical and high-performance focusing solution capable of enhancing the reliability, throughput, and diagnostic utility of portable retinal imaging in large-scale screening applications. Future efforts will be directed towards system cost optimization and performance adaptation for diverse ocular conditions.
2.Expert Consensus on the Ethical Requirements for Generative AI-Assisted Academic Writing
You-Quan BU ; Yong-Fu CAO ; Zeng-Yi CHANG ; Hong-Yu CHEN ; Xiao-Wei CHEN ; Yuan-Yuan CHEN ; Zhu-Cheng CHEN ; Rui DENG ; Jie DING ; Zhong-Kai FAN ; Guo-Quan GAO ; Xu GAO ; Lan HU ; Xiao-Qing HU ; Hong-Ti JIA ; Ying KONG ; En-Min LI ; Ling LI ; Yu-Hua LI ; Jun-Rong LIU ; Zhi-Qiang LIU ; Ya-Ping LUO ; Xue-Mei LV ; Yan-Xi PEI ; Xiao-Zhong PENG ; Qi-Qun TANG ; You WAN ; Yong WANG ; Ming-Xu WANG ; Xian WANG ; Guang-Kuan XIE ; Jun XIE ; Xiao-Hua YAN ; Mei YIN ; Zhong-Shan YU ; Chun-Yan ZHOU ; Rui-Fang ZHU
Chinese Journal of Biochemistry and Molecular Biology 2025;41(6):826-832
With the rapid development of generative artificial intelligence(GAI)technologies,their widespread application in academic research and writing is continuously expanding the boundaries of sci-entific inquiry.However,this trend has also raised a series of ethical and regulatory challenges,inclu-ding issues related to authorship,content authenticity,citation accuracy,and accountability.In light of the growing involvement of AI in generating academic content,establishing an open,controllable,and trustworthy ethical governance framework has become a key task for safeguarding research integrity and maintaining trust within the academic community.This expert consensus outlines ethical requirements across key stages of AI-assisted academic writing-including topic selection,data management,citation practices,and authorship attribution.It aims to clarify the boundaries and ethical obligations surrounding AI use in academic writing,ensuring that technological tools enhance efficiency without compromising in-tegrity.The goal is to provide guidance and institutional support for building a responsible and sustainable research ecosystem.
3.Expert consensus on visualized tele-round and quality control management based on the improvement of clinical practice ability
Wanhong YIN ; Xiaoting WANG ; Ran ZHOU ; Dawei LIU ; Yan KANG ; Yaoqing TANG ; Xiaochun MA ; Jianguo LI ; Zhenjie HU ; Haitao ZHANG ; Wei HE ; Lixia LIU ; Wenjin CHEN ; Ran ZHU ; Jun WU ; Hongmin ZHANG ; Lina ZHANG ; Wenzhao CHAI ; Shihong ZHU ; Wangbin XU ; Rongqing SUN ; Xiangyou YU ; Tianjiao SONG ; Ying ZHU ; Hong REN ; Ai SHANMU ; Qing ZHANG ; Wei FANG ; Xiuling SHANG ; Liwen LYU ; Shuhan CAI ; Xin DING ; Heng ZHANG ; Guang FENG ; Lipeng ZHANG ; Bo HU ; Dong ZHANG ; Weidong WU ; Feng SHEN ; Xiaojun YANG ; Zhenguo ZENG ; Qibing HUANG ; Xueying ZENG ; Tongjuan ZOU ; Milin PENG ; Yulong YAO ; Mingming CHEN ; Hui LIAN ; Jingmei WANG ; Yong LI ; Feng QU ; Gang YE ; Rongli YANG ; Xiukai CHEN ; Suwei LI ; Juxiang WANG ; Yangong CHAO
Chinese Journal of Internal Medicine 2025;64(2):101-109
Turning to critical illness is a common stage of various diseases and injuries before death. Patients usually have complex health conditions, while the treatment process involves a wide range of content, along with high requirements for doctor′s professionalism and multi-specialty teamwork, as well as a great demand for time-sensitive treatments. However, this is not matched with critical care professionals and the current state of medical care in China. Telemedicine, which shortens the distance of medical professionals and the gap of disease diagnosis and treatments in various regions through electronic information, can effectively solve the current problem. Therefore, there is an urgent need to develop a standardized, high-quality visualization telemedicine round system .Therefore, experts have been organized to search domestic and foreign literature on telemedicine round for critically ill patients and to form this consensus based on clinical experiences so as to further improve the level of critical care treatments in regions.
4.Expert consensus on visualized tele-round and quality control management based on the improvement of clinical practice ability
Wanhong YIN ; Xiaoting WANG ; Ran ZHOU ; Dawei LIU ; Yan KANG ; Yaoqing TANG ; Xiaochun MA ; Jianguo LI ; Zhenjie HU ; Haitao ZHANG ; Wei HE ; Lixia LIU ; Wenjin CHEN ; Ran ZHU ; Jun WU ; Hongmin ZHANG ; Lina ZHANG ; Wenzhao CHAI ; Shihong ZHU ; Wangbin XU ; Rongqing SUN ; Xiangyou YU ; Tianjiao SONG ; Ying ZHU ; Hong REN ; Ai SHANMU ; Qing ZHANG ; Wei FANG ; Xiuling SHANG ; Liwen LYU ; Shuhan CAI ; Xin DING ; Heng ZHANG ; Guang FENG ; Lipeng ZHANG ; Bo HU ; Dong ZHANG ; Weidong WU ; Feng SHEN ; Xiaojun YANG ; Zhenguo ZENG ; Qibing HUANG ; Xueying ZENG ; Tongjuan ZOU ; Milin PENG ; Yulong YAO ; Mingming CHEN ; Hui LIAN ; Jingmei WANG ; Yong LI ; Feng QU ; Gang YE ; Rongli YANG ; Xiukai CHEN ; Suwei LI ; Juxiang WANG ; Yangong CHAO
Chinese Journal of Internal Medicine 2025;64(2):101-109
Turning to critical illness is a common stage of various diseases and injuries before death. Patients usually have complex health conditions, while the treatment process involves a wide range of content, along with high requirements for doctor′s professionalism and multi-specialty teamwork, as well as a great demand for time-sensitive treatments. However, this is not matched with critical care professionals and the current state of medical care in China. Telemedicine, which shortens the distance of medical professionals and the gap of disease diagnosis and treatments in various regions through electronic information, can effectively solve the current problem. Therefore, there is an urgent need to develop a standardized, high-quality visualization telemedicine round system .Therefore, experts have been organized to search domestic and foreign literature on telemedicine round for critically ill patients and to form this consensus based on clinical experiences so as to further improve the level of critical care treatments in regions.
5.Expert Consensus on the Ethical Requirements for Generative AI-Assisted Academic Writing
You-Quan BU ; Yong-Fu CAO ; Zeng-Yi CHANG ; Hong-Yu CHEN ; Xiao-Wei CHEN ; Yuan-Yuan CHEN ; Zhu-Cheng CHEN ; Rui DENG ; Jie DING ; Zhong-Kai FAN ; Guo-Quan GAO ; Xu GAO ; Lan HU ; Xiao-Qing HU ; Hong-Ti JIA ; Ying KONG ; En-Min LI ; Ling LI ; Yu-Hua LI ; Jun-Rong LIU ; Zhi-Qiang LIU ; Ya-Ping LUO ; Xue-Mei LV ; Yan-Xi PEI ; Xiao-Zhong PENG ; Qi-Qun TANG ; You WAN ; Yong WANG ; Ming-Xu WANG ; Xian WANG ; Guang-Kuan XIE ; Jun XIE ; Xiao-Hua YAN ; Mei YIN ; Zhong-Shan YU ; Chun-Yan ZHOU ; Rui-Fang ZHU
Chinese Journal of Biochemistry and Molecular Biology 2025;41(6):826-832
With the rapid development of generative artificial intelligence(GAI)technologies,their widespread application in academic research and writing is continuously expanding the boundaries of sci-entific inquiry.However,this trend has also raised a series of ethical and regulatory challenges,inclu-ding issues related to authorship,content authenticity,citation accuracy,and accountability.In light of the growing involvement of AI in generating academic content,establishing an open,controllable,and trustworthy ethical governance framework has become a key task for safeguarding research integrity and maintaining trust within the academic community.This expert consensus outlines ethical requirements across key stages of AI-assisted academic writing-including topic selection,data management,citation practices,and authorship attribution.It aims to clarify the boundaries and ethical obligations surrounding AI use in academic writing,ensuring that technological tools enhance efficiency without compromising in-tegrity.The goal is to provide guidance and institutional support for building a responsible and sustainable research ecosystem.
6.Full-field Anterior Chamber Angle Measurement Based on Optical Reflection Tomography
Bi-Wang LIU ; Jun-Ping ZHONG ; Hai-Na LIN ; Ya-Guang ZENG ; You-Ping YU ; Hong-Yi LI ; Ding-An HAN ; Jin-Ying CHEN
Progress in Biochemistry and Biophysics 2024;51(9):2240-2248
ObjectiveAngle-closure glaucoma (ACG) is one of the major eye-blinding diseases. To diagnose ACG, it is crucial to examine the anterior chamber angle. Current diagnostic tools include slit lamp gonioscopy, water gonioscopy, ultrasound biomicroscopy (UBM), and anterior segment optical coherence tomography (AS-OCT). Slit lamp and water gonioscopy allow convenient observation of the anterior chamber angle, but pose risks of invasive operation and eye infections. UBM can accurately measure the structure of the anterior chamber angle. However, it is complex to operate and unsuitable for patients, who have undergone trauma or ocular surgery. Although AS-OCT provides detailed images, it is costly. The aim of this study is to explore a non-invasive, non-destructive optical reflection tomography (ORT) technique. This technique can achieve low-cost three-dimensional imaging and full-field anterior chamber angle measurement of the porcine eye. MethodsThe experiment involved assembling an optical reflection tomography system, which included a complementary metal oxide semiconductor (CMOS) camera, a telecentric system, a stepper motor, and a white light source, achieving a spatial resolution of approximately 8.5 μm. The process required positioning the porcine eye at the center of the field of the imaging system and rotating it around its central axis using a stepper motor. Reflection projection images were captured at each angle with an exposure time of 1.0 ms and an interval of 2°. The collected reflection-projection data were processed using a filtered reflection tomography algorithm, generating a series of two-dimensional slice data. These slices essentially represented cross-sectional views of the three-dimensional structural image, and were reconstructed into a complete three-dimensional structural image. Based on the reconstructed three-dimensional structural image of the porcine eye, the anterior chamber angles at different positions were measured, and a distribution map of these angles was drawn. Simultaneously, the ORT measurements were compared with the standard results obtained from optical coherence tomography (OCT) to assess the accuracy of ORT measurements. ResultsIn this study, we successfully obtained the reflection projection data of a porcine eye using ORT technology, reconstructed its three-dimensional structural image, and measured the anterior chamber angle, generating the corresponding distribution map. To better distinguish the different structural parts of porcine eye, the three-dimensional structural image was marked with blue, green, and yellow dashed lines from the outer to the inner layers. The area between the blue and green dashed lines corresponded to the sclera. The area between the green and yellow dashed lines corresponded to the iris. The area inside the yellow dashed line corresponded to the pupil. The three-dimensional structural image clearly revealed the key anatomical features of the porcine eye. It was able to measure the anterior chamber angle at different positions. Additionally, the anterior chamber angle measurements of the porcine eye using ORT were compared with the measurements obtained using a TEL320C1 type OCT system, showing an average deviation of 0.51° and a mean square error
7.Efficacy and safety of recombinant human anti-SARS-CoV-2 monoclonal antibody injection(F61 injection)in the treatment of patients with COVID-19 combined with renal damage:a randomized controlled exploratory clinical study
Ding-Hua CHEN ; Chao-Fan LI ; Yue NIU ; Li ZHANG ; Yong WANG ; Zhe FENG ; Han-Yu ZHU ; Jian-Hui ZHOU ; Zhe-Yi DONG ; Shu-Wei DUAN ; Hong WANG ; Meng-Jie HUANG ; Yuan-Da WANG ; Shuo-Yuan CONG ; Sai PAN ; Jing ZHOU ; Xue-Feng SUN ; Guang-Yan CAI ; Ping LI ; Xiang-Mei CHEN
Chinese Journal of Infection Control 2024;23(3):257-264
Objective To explore the efficacy and safety of recombinant human anti-severe acute respiratory syn-drome coronavirus 2(anti-SARS-CoV-2)monoclonal antibody injection(F61 injection)in the treatment of patients with coronavirus disease 2019(COVID-19)combined with renal damage.Methods Patients with COVID-19 and renal damage who visited the PLA General Hospital from January to February 2023 were selected.Subjects were randomly divided into two groups.Control group was treated with conventional anti-COVID-19 therapy,while trial group was treated with conventional anti-COVID-19 therapy combined with F61 injection.A 15-day follow-up was conducted after drug administration.Clinical symptoms,laboratory tests,electrocardiogram,and chest CT of pa-tients were performed to analyze the efficacy and safety of F61 injection.Results Twelve subjects(7 in trial group and 5 in control group)were included in study.Neither group had any clinical progression or death cases.The ave-rage time for negative conversion of nucleic acid of SARS-CoV-2 in control group and trial group were 3.2 days and 1.57 days(P=0.046),respectively.The scores of COVID-19 related target symptom in the trial group on the 3rd and 5th day after medication were both lower than those of the control group(both P<0.05).According to the clinical staging and World Health Organization 10-point graded disease progression scale,both groups of subjects improved but didn't show statistical differences(P>0.05).For safety,trial group didn't present any infusion-re-lated adverse event.Subjects in both groups demonstrated varying degrees of elevated blood glucose,elevated urine glucose,elevated urobilinogen,positive urine casts,and cardiac arrhythmia,but the differences were not statistica-lly significant(all P>0.05).Conclusion F61 injection has initially demonstrated safety and clinical benefit in trea-ting patients with COVID-19 combined with renal damage.As the domestically produced drug,it has good clinical accessibility and may provide more options for clinical practice.
8.Effect of palmatine inhibiting migration,invasion and epithelial mesenchymal transformation in human oral cancer KB cells
Xue-Yun CHENG ; Guang-Yao HU ; Hong-Li LIU ; Chen-Guang LIU ; Yuan-Li DING ; Hui-Ning YANG ; Yi-An ZHAO ; Zhi-Guang SUN
The Chinese Journal of Clinical Pharmacology 2024;40(12):1749-1753
Objective To investigate the effects of palmatine on migration,invasion and epithelial mesenchymal transformation(EMT)in human oral cancer KB cells.Methods KB cells were divided into control group and palmatine-L,-M,-H groups,cultured with 0,4,8 and 16 μmol·L-1 palmatine.After incubation for 48 h,scratch assay was used to detect migration;Traswell assay was used to detect invasion;matrix metalloproteinase 2(MMP-2),MMP-9 and fibronectin(FN)contents were detected by enzyme-linked immunosorbent assay;the expression of Vimentin,N-cadherin and E-cadherin mRNA were detected by real-time quantitative polymerase chain reaction;the expression of Vimentin,N-cadherin,E-cadherin,Wnt3 and β-catenin protein were detected by Western blot.Results Cell mobility in control group and palmatine-L,-M,-H groups were(69.27±8.62)%,(52.94±4.49)%,(45.22±5.05)%and(37.63±4.88)%;the number of transmembrane cells were 197.33±20.26,125.33±12.01,97.00±9.17 and 62.67±7.51;the content of MMP-2 were(2.93±0.21),(1.49±0.13),(1.16±0.15)and(0.95±0.09)ng·mL-1;the content of MMP-9 were(3.51±0.36),(2.37±0.23),(2.06±0.35)and(1.72±0.16)ng·mL-1;the content of FN were(41.28±4.02),(24.03±3.17),(20.67±2.63)and(13.82±2.19)ng·mL-1;the above indexes in palmatine-L,-M,-H groups were compared with the control group,and the differences were statistically significant(P<0.05,P<0.01).The mRNA and protein expressions of Vimentin,N-cadherin and E-cadherin,and the expressions of Wnt3 and β-catenin protein in palmatine-L,-M,-H groups were statistically significant compared with those in control group(P<0.05,P<0.01).Conclusion Palmatine can inhibit the migration,invasion and EMT of human oral cancer KB cells,and its mechanism is related to the regulation of Wnt/β-catenin signaling pathway.
9. Treatment advice of small molecule antiviral drugs for elderly COVID-19
Min PAN ; Shuang CHANG ; Xiao-Xia FENG ; Guang-He FEI ; Jia-Bin LI ; Hua WANG ; Du-Juan XU ; Chang-Hui WANG ; Yan SUN ; Xiao-Yun FAN ; Tian-Jing ZHANG ; Wei WEI ; Ling-Ling ZHANG ; Jim LI ; Fei-Hu CHEN ; Xiao-Ming MENG ; Hong-Mei ZHAO ; Min DAI ; Yi XIANG ; Meng-Shu CAO ; Xiao-Yang CHEN ; Xian-Wei YE ; Xiao-Wen HU ; Ling JIANG ; Yong-Zhong WANG ; Hao LIU ; Hai-Tang XIE ; Ping FANG ; Zhen-Dong QIAN ; Chao TANG ; Gang YANG ; Xiao-Bao TENG ; Chao-Xia QIAN ; Guo-Zheng DING
Chinese Pharmacological Bulletin 2023;39(3):425-430
COVID-19 has been prevalent for three years. The virulence of SARS-CoV-2 is weaken as it mutates continuously. However, elderly patients, especially those with underlying diseases, are still at high risk of developing severe infections. With the continuous study of the molecular structure and pathogenic mechanism of SARS-CoV-2, antiviral drugs for COVID-19 have been successively marketed, and these anti-SARS-CoV-2 drugs can effectively reduce the severe rate and mortality of elderly patients. This article reviews the mechanism, clinical medication regimens, drug interactions and adverse reactions of five small molecule antiviral drugs currently approved for marketing in China, so as to provide advice for the clinical rational use of anti-SARS-CoV-2 in the elderly.
10.Clinical and bronchoscopy features of tracheobronchial tuberculosis in children.
Shuai PENG ; Guang-Li ZHANG ; Jing-Xian HONG ; Hao DING ; Chong-Jie WANG ; Jian LUO ; Zheng-Xiu LUO
Chinese Journal of Contemporary Pediatrics 2023;25(4):381-387
OBJECTIVES:
To study the clinical and bronchoscopic characteristics of tracheobronchial tuberculosis (TBTB) in children and to identify factors influencing residual airway obstruction or stenosis.
METHODS:
The clinical data of children with TBTB were retrospectively collected. The children were divided into two groups based on the last bronchoscopic result within one year of follow-up: a group with residual airway obstruction or stenosis (n=34) and a group without residual airway obstruction or stenosis (n=58). A multivariate logistic regression analysis was used to identify the factors influencing residual airway obstruction or stenosis in children with TBTB. Receiver operating characteristic (ROC) curves were used to analyze the predictive value of the factors influencing residual airway obstruction or stenosis in children with TBTB.
RESULTS:
A total of 92 children with TBTB were included, and the main symptoms were cough (90%) and fever (68%). In children under 1 year old, the incidence rates of dyspnea and wheezing were significantly higher than in other age groups (P<0.008). Chest CT findings included mediastinal or hilar lymph node enlargement (90%) and tracheobronchial stenosis or obstruction (61%). The lymphatic fistula type was the main type of TBTB observed bronchoscopically (77%). All children received interventional treatment, and the effective rate was 84%. During one year of follow-up, 34 children had residual airway obstruction or stenosis. The TBTB diagnostic time and the initiation of interventional treatment were significantly delayed in the group with residual airway obstruction or stenosis compared with the group without residual airway obstruction or stenosis (P<0.05). The multivariate logistic regression analysis showed that the TBTB diagnostic time was closely related to residual airway obstruction or stenosis in children (P<0.05). ROC curve analysis showed that at the cut-off value of 92 days of TBTB diagnostic time, the area under the curve for predicting residual airway obstruction or stenosis in children with TBTB was 0.707, with a sensitivity of 58.8% and a specificity of 75.9%.
CONCLUSIONS
The clinical manifestations of TBTB are nonspecific, and symptoms are more severe in children under 1 year old. TBTB should be suspected in children with tuberculosis and chest imaging indicating airway involvement. Delayed diagnosis of TBTB is associated with the development of residual airway obstruction or stenosis.
Infant
;
Child
;
Humans
;
Bronchoscopy/methods*
;
Constriction, Pathologic/complications*
;
Bronchial Diseases/therapy*
;
Retrospective Studies
;
Tuberculosis/diagnosis*
;
Airway Obstruction/therapy*

Result Analysis
Print
Save
E-mail