1.Compact Fundus Imaging System Using Shack-Hartmann Wavefront Sensing for High-speed Auto-focus
Zhe-Kai LIN ; Long CHEN ; Geng-Yong ZHENG ; Jin-Tian HUANG ; Jia-Xin DONG ; Shang-Pan YANG ; Wen-Zheng DING ; Ding-An HAN ; Xue-Hua WANG ; Ya-Guang ZENG
Progress in Biochemistry and Biophysics 2026;53(4):1076-1086
ObjectiveThe widespread adoption of portable fundus cameras for primary care and community screening is hindered by limitations in current autofocus(AF) technologies. Image-based methods relying on sharpness evaluation require iterative searches, resulting in slow convergence, while projection-based techniques are susceptible to optical artifacts and calibration errors. To address these challenges, this study introduces a novel AF system based on direct wavefront sensing, designed to deliver simultaneous high speed, high precision, and operational robustness within the compact form factor essential for portable ophthalmic devices. MethodsOur approach fundamentally reimagines the AF process by directly measuring the ocular wavefront aberration. We developed a custom portable fundus camera integrating a miniaturized Shack-Hartmann wavefront sensor (SHWS) into the optical path. An 850 nm laser diode projects a point source onto the retina via oblique illumination to minimize corneal reflections. Light scattered from this spot carries the eye’s refractive error through the imaging optics and is directed to the SHWS, positioned at a plane optically conjugate to the primary color CMOS imaging sensor. A microlens array within the SHWS samples the incident wavefront, generating a pattern of focal spots on a CCD. Real-time centroid analysis of these spots provides a map of local wavefront slopes. These measurements are processed through a singular value decomposition (SVD) algorithm to fit a Zernike polynomial basis set, enabling real-time reconstruction of the wavefront phase. The defocus component (S) is extracted from the second-order Zernike coefficients, providing a direct, quantitative measure of the refractive error in diopters. This value serves as a precise error signal in a closed-loop control system, which commands a voice-coil actuated focusing lens to its null position in a single, deterministic step, eliminating the need for iterative search algorithms. ResultsComprehensive evaluation demonstrated the system’s high performance. Testing on a calibrated model eye (OEMI-7) established a highly linear relationship between the computed defocus S and the focusing lens position across a ±20 Diopter (D) compensation range, achievable within a 5 mm mechanical travel. The system achieved a focusing precision of 0.08 D, corresponding to an 18-fold improvement over a conventional projection spot-size method tested under identical conditions. The total focus acquisition time, encompassing wavefront measurement, computation, and lens actuation, averaged under 0.5 s. Clinical validation with 25 human volunteers (50 eyes, refractive range -15 D to +10 D) confirmed practical efficacy. The wavefront-sensing AF succeeded in 92% of attempts with a mean time of 0.5 s, substantially outperforming a projection-based benchmark which achieved only a 32% success rate with an average time of 4.25 s. The system provided instantaneous directional guidance and maintained stability during minor ocular movements. Objective assessment of image quality, via amplitude contrast of retinal vasculature, showed consistent and significant enhancement following AF correction across the entire tested diopter range. ConclusionThis work successfully implements and validates a direct wavefront-sensing autofocus paradigm for portable fundus cameras. By directly quantifying and compensating for the optical defocus aberration, this method bypasses the fundamental limitations of image-processing and projection-based techniques, enabling rapid, precise, and deterministic diopter compensation. The developed system delivers an exceptional combination of a wide operational range (±20 D), high accuracy (0.08 D), fast convergence (0.5 s), and a compact physical footprint. This technology provides a practical and high-performance focusing solution capable of enhancing the reliability, throughput, and diagnostic utility of portable retinal imaging in large-scale screening applications. Future efforts will be directed towards system cost optimization and performance adaptation for diverse ocular conditions.
2.Research on Targeted Screening of Diflorasone Components in Health Products Using Feature Ion Guided Strategy Combined with High-Resolution Mass Spectrometry
Shuo-Jun OU ; Yin-Yin LIN ; Hai-Tao ZHANG ; Jian-Bin CEN ; Zhi-Yuan WANG ; Xin-Dong GUO ; Jia-Jun ZHANG ; Zhi-Sen LIANG ; Guang-Feng ZENG
Chinese Journal of Analytical Chemistry 2025;53(8):1320-1330,中插88-中插92
A method for determination and targeted screening of diflorasone components in health products using ultra performance liquid chromatography-quadrupole time of flight mass spectrometry(UPLC-Q-TOF/MS)was established.Four representative diflorasone and esters(diflorasone,diflorasone diacetate,diflorasone-17-propionate,and diflorasone-21-propionate)were selected to optimize the pretreatment conditions,and 10 mL of extraction solvent dosage,15 min of extraction time and 5 g of salting-out agent as the optimal conditions were selected by response surface methodology.The results showed that the four analytes exhibited good linearity within the concentration range of 2.0?100 μg/L with the chromatographic peak area,and the correlation coefficients(R2)were all greater than 0.9990,while the results of recovery and relative standard deviation could satisfy the requirements of determination.The common characteristic ions of diflorasone and esters werem/z121 andm/z335,and their specific structures were obtained by analyzing the cleavage pathway based on the optimized determination conditions.A targeted screening method for other esters of diflorasone based on characteristic ions guidance strategy was established.This method had many advantages such as high efficiency,high sensitivity and good reproducibility,and could be used for targeted screening of diflorasone and esters in health products.The developed characteristic ion guided strategy could be employed to construct mass spectral databases for various glucocorticoids,enabling comprehensive targeted screening across a broad range of compounds.
3.Reliable Extraction of Seawater Nd and Hf Isotope Compositions from Fe-Mn Oxyhydroxide Fraction of Marine Sediments in the Arctic Ocean
Ying ZHANG ; Lin-Sen DONG ; Hong-Min WANG ; Xiao-Jing WANG ; Lian-Hua HE ; Yan-Guang LIU ; Ji-Hua LIU
Chinese Journal of Analytical Chemistry 2025;53(8):1380-1390
Combined seawater Hf and Nd isotope compositions have been applied as reliable tracers of water mass mixing and weathering input changes.The establishment of standardized synchronous extraction methods for Fe-Mn oxyhydroxide in sediments,which serve as effective carriers for isotopic signals of ancient seawater,is a prerequisite and key for paleoceanography research.The research material of this study was the surface sediments of the Western Arctic Ocean obtained from China's 7th Arctic Scientific Expedition,and a reliable simultaneous Nd-Hf isotope extraction method in Fe-Mn oxyhydroxide fraction was established through systematic optimization of pretreatment procedures and key extraction parameters.This research focused on analyzing the effects of pretreatment(Milli-Q water pre-wash)and key extraction parameters(leaching time,solution/solid ratios,concentration of EDTA-2Na,and concentration of mixed solution of hydroxyamine hydrochloride(HH)and acetic acid(HAc))on element extraction efficiency and isotopic composition.The experimental results indicated that the Milli-Q water pre-wash was not necessary,Fe-Mn oxyhydroxide extraction could be directly performed.Nd extraction amount in Fe-Mn oxyhydroxide fraction was not sensitive to changes in extraction conditions,while the Hf extraction amount was significantly affected by leaching time,solution/solid ratios and concentration of EDTA-2Na.The optimal conditions for synchronously extracting Nd-Hf isotopes were as follows:adding 20 mL of a mixed solution of 0.005 mol/L HH+1.5%HAc+0.03 mol/L EDTA-2Na per gram of sample,and reaction at room temperature for 3 h under shaking.Through systematic verification of 87Sr/86Sr ratio,εNd value,εHf value,Al/Nd ratio and Al/Hf ratio,it was confirmed that this method could effectively avoid interferences from residual components and accurately obtain Nd-Hf isotope signals of ancient seawater preserved in sediments.The standardized method established in this work provided reliable technical support for reconstructing water mass mixing between the Arctic,North Atlantic,and North Pacific Oceans and riverine input histories.It also provided important reference for the extraction methods of Nd and Hf isotopes from marine sources in sediments from other sea areas around the world.
4.Chemical constituents of Sophorae Flavescentis Radix and its residue based on UPLC-Q-TOF-MS.
Qian-Wen LIU ; Rong-Qing ZHU ; Qian-Nan HU ; Xiang LI ; Guang YANG ; Zi-Dong QIU ; Zhi-Lai ZHAN ; Tie-Gui NAN ; Mei-Lan CHEN ; Li-Ping KANG
China Journal of Chinese Materia Medica 2025;50(3):708-718
Sophorae Flavescentis Radix is one of the commonly used traditional Chinese medicine in China, and a large amount of pharmaceutical residue generated during its processing and production is discarded as waste, which not only wastes resources but also pollutes the environment. Therefore, elucidating the chemical composition of the residue of Sophorae Flavescentis Radix and the differences between the residue and Sophorae Flavescentis Radix itself is of great significance for the comprehensive utilization of the residue. This study, based on ultra-performance liquid chromatography-quadrupole time-of-flight mass spectrometry(UPLC-Q-TOF-MS) technology combined with multivariate statistical methods, provides a thorough characterization, identification, and differential analysis of the overall components of Sophorae Flavescentis Radix and its residue. Firstly, 61 compounds in Sophorae Flavescentis Radix were rapidly identified based on their precise molecular weight, fragment ions, and compound abundance, using a self-constructed compound database. Among them, 41 compounds were found in the residue, mainly alkaloids and flavonoids. Secondly, through principal component analysis(PCA) and orthogonal partial least squares discriminant analysis(OPLS-DA), 15 key compounds differentiating Sophorae Flavescentis Radix from its residue were identified. These included highly polar alkaloids, such as oxymatrine and oxysophocarpine, which showed significantly reduced content in the residue, and less polar flavonoids, such as kurarinone and kuraridin, which were more abundant in the residue. In summary, this paper clarifies the overall composition, structure, and content differences between Sophorae Flavescentis Radix and its residue, suggesting that the residue of Sophorae Flavescentis Radix can be used as a raw material for the extraction of its high-activity components, with promising potential for development and application in cosmetics and daily care. This research provides a scientific basis for the future comprehensive utilization of Sophorae Flavescentis Radix and its residue.
Drugs, Chinese Herbal/chemistry*
;
Chromatography, High Pressure Liquid/methods*
;
Mass Spectrometry/methods*
;
Sophora/chemistry*
;
Flavonoids/chemistry*
;
Alkaloids/chemistry*
5.Integration and innovation of wet granulation and continuous manufacturing technology: a review of on-line detection, modeling, and process scale-up.
Guang-di YANG ; Ge AO ; Yang CHEN ; Yu-Fang HUANG ; Shu CHEN ; Dong-Xun LI ; Wen-Liu ZHANG ; Tian-Tian WANG ; Guo-Song ZHANG
China Journal of Chinese Materia Medica 2025;50(6):1484-1495
Continuous manufacturing, as an innovative pharmaceutical production model, offers advantages such as high production efficiency and ease of control compared to traditional batch production, aligning with the future trend of drug production moving toward greater efficiency and intelligence. However, the development of continuous manufacturing technology in wet granulation has been slow. On one hand, this is closely related to its high technical complexity, substantial equipment investment costs, and stringent process control requirements. On the other hand, the long-term use of the traditional batch production model has created strong path dependence, and the lack of mature standardized processes further increases the difficulty of technological transformation. To promote the deep integration of wet granulation technology with continuous manufacturing, this review systematically outlines the current application of wet granulation in continuous manufacturing. It focuses on the development of key technologies such as online detection, process modeling, and process scale-up, with the aim of providing a reference for process innovation and application in wet granulation.
Drug Compounding/instrumentation*
;
Technology, Pharmaceutical/methods*
;
Drugs, Chinese Herbal/chemistry*
;
Models, Theoretical
6.Expert consensus on evaluation index system construction for new traditional Chinese medicine(TCM) from TCM clinical practice in medical institutions.
Li LIU ; Lei ZHANG ; Wei-An YUAN ; Zhong-Qi YANG ; Jun-Hua ZHANG ; Bao-He WANG ; Si-Yuan HU ; Zu-Guang YE ; Ling HAN ; Yue-Hua ZHOU ; Zi-Feng YANG ; Rui GAO ; Ming YANG ; Ting WANG ; Jie-Lai XIA ; Shi-Shan YU ; Xiao-Hui FAN ; Hua HUA ; Jia HE ; Yin LU ; Zhong WANG ; Jin-Hui DOU ; Geng LI ; Yu DONG ; Hao YU ; Li-Ping QU ; Jian-Yuan TANG
China Journal of Chinese Materia Medica 2025;50(12):3474-3482
Medical institutions, with their clinical practice foundation and abundant human use experience data, have become important carriers for the inheritance and innovation of traditional Chinese medicine(TCM) and the "cradles" of the preparation of new TCM. To effectively promote the transformation of new TCM originating from the TCM clinical practice in medical institutions and establish an effective evaluation index system for the transformation of new TCM conforming to the characteristics of TCM, consensus experts adopted the literature research, questionnaire survey, Delphi method, etc. By focusing on the policy and technical evaluation of new TCM originating from the TCM clinical practice in medical institutions, a comprehensive evaluation from the dimensions of drug safety, efficacy, feasibility, and characteristic advantages was conducted, thus forming a comprehensive evaluation system with four primary indicators and 37 secondary indicators. The expert consensus reached aims to encourage medical institutions at all levels to continuously improve the high-quality research and development and transformation of new TCM originating from the TCM clinical practice in medical institutions and targeted at clinical needs, so as to provide a decision-making basis for the preparation, selection, cultivation, and transformation of new TCM for medical institutions, improve the development efficiency of new TCM, and precisely respond to the public medication needs.
Medicine, Chinese Traditional/standards*
;
Humans
;
Consensus
;
Drugs, Chinese Herbal/therapeutic use*
;
Surveys and Questionnaires
7.Textual study of Baihuasheshecao (Hedyotis diffusa).
Dong-Min JIANG ; Chu-Chu ZHONG ; Pang-Chui SHAW ; Bik-San LAU ; Tai-Wai LAU ; Guang-Hao XU ; Ying ZHANG ; Zhi-Guo MA ; Hui CAO ; Meng-Hua WU
China Journal of Chinese Materia Medica 2025;50(15):4386-4396
Baihuasheshecao(Hedyotis diffusa) is a commonly used traditional Chinese medicine derived from the whole herb of H. diffusa and has been widely utilized in folk medicine. It possesses anti-tumor, antibacterial, and anti-inflammatory properties, making it one of the frequently used herbs in TCM clinical practice. However, Shuixiancao(H. corymbosa) and Xianhuaercao(H. tenelliflora), species of the same genus, are often used as substitutes for Baihuasheshecao. To substantiate the medicinal basis of Baihuasheshecao, this study systematically reviewed classical herbal texts and modern literature, examining its nomenclature, botanical origin, harvesting, processing, properties, meridian tropism, pharmacological effects, and clinical applications. The results indicate that Baihuasheshecao was initially recorded as "Shuixiancao" in Preface to the Indexes to the Great Chinese Botany(Zhi Wu Ming Shi Tu Kao). Based on its morphological characteristics and habitat description, it was identified as H. diffusa in the Rubiaceae family. Subsequent records predominantly refer to it as Baihuasheshecao as its official name. In most regions, Baihuasheshecao is recognized as the authentic medicinal material, distinct from Shuixiancao and Xianhuaercao. Baihuasheshecao is harvested in late summer and early autumn, and the dried whole plant, including its roots, is used medicinally. The standard processing method involves cutting. It is known for its effects in clearing heat, removing toxins, reducing swelling and pain, and promoting diuresis to resolve abscesses. Initially, it was mainly used for treating appendicitis, intestinal abscesses, and venomous snake bites, and later, it became a treatment for cancer. The excavation of its clinical value followed a process in which overseas Chinese introduced the herb from Chinese folk medicine to other countries. After its unique anti-cancer effects were recognized abroad, it was reintroduced to China and gradually became a crucial TCM for cancer treatment. The findings of this study help clarify the historical and contemporary uses of Baihuasheshecao, providing literature support and a scientific basis for its rational development and precise clinical application.
Humans
;
China
;
Drugs, Chinese Herbal/chemistry*
;
Hedyotis/classification*
;
Medicine, Chinese Traditional/history*
8.Effects of Conbercept on different optical coherence tomography biomarkers in patients with retinal vein occlusion-related macular edema
Haiyue YU ; Juan TENG ; Zeying DONG ; Lili ZHANG ; Huixian CUI ; Chang LIU ; Guang ZHU ; Xin LI
International Eye Science 2025;25(10):1656-1661
AIM: To investigate the effects of Conbercept on various optical coherence tomography(OCT)biomarkers in patients with retinal vein occlusion-related macular edema(RVO-ME), and to analyze the correlation of these biomarker changes with visual prognosis.METHODS: Retrospective study. A total of 57 patients(57 eyes)with RVO-ME, including 25 patients(25 eyes)with central retinal vein occlusion(CRVO)and 32 patients(32 eyes)with branch retinal vein occlusion(BRVO), were enrolled in this study. All the patients received intravitreal injection of conbercept once a month, three times in total. The preoperative and postoperative best-corrected visual acuity(BCVA), and changes in OCT biomarkers, including central macular thickness(CMT), the length of disorganization of the retinal inner layers(DRIL), the number of hyperreflective dots(HRD), the area of intraretinal fluid(IRF), the area of subretinal fluid(SRF), and the length of ellipsoid zone(EZ)disruption were compared. Furthermore, the relationship of these changes with BCVA was analyzed.RESULTS:Compared with the baseline, at 3 mo post-treatment, BCVA(LogMAR)was improved, CMT was decreased, the length of DRIL was shortened, the number of HRD was reduced, the area of IRF was decreased, the area of SRF was reduced, and the length of EZ disruption was shortened(all P<0.05). Spearman correlation analysis showed that there was no correlation between the changes in CMT, the length of DRIL, the number of HRD, the area of IRF, the area of SRF and the change in BCVA before and after treatment(P>0.05). However, the change in the length of EZ disruption was positively correlated with the change in BCVA(rs=0.34, P=0.011), and the R2 value of the fitting curve between the change in the length of EZ disruption and the change in BCVA was 0.113(P=0.011). When comparing the pre- and post-treatment changes in BCVA, the length of DRIL, the number of HRD, the area of IRF, the area of SRF, and the length of EZ disruption between patients in the CRVO group and BRVO group, no significant differences were observed(all P>0.05). In contrast, a significant difference was found in the change in CMT between the two groups(P=0.002).CONCLUSION:Conbercept effectively improves multiple OCT biomarkers in patients with RVO-ME. Repair of EZ disruption is a key driver of visual recovery, and its stability may serve as a novel indicator for personalized decision-making in anti-vascular endothelial growth factor therapy.
9.Study on the current situation and influencing factors of nutritional risk in children in PICU
Lian-Ye LI ; Ying-Jie DUAN ; Guang-Yu LI ; Qi LI ; Mao MAO ; Yu TIAN ; Dong-Xue LÜ ; Wei ZHANG ; Xin-Hui LIU
Parenteral & Enteral Nutrition 2025;32(1):23-28
Objective:To investigate the nutritional risk status of children in PICU and analyze its influencing factors.Methods:From July 2021 to February 2023,all children aged 1 to 18 years admitted to PICU of Beijing Children's Hospital were investigated by using the pediatric Yorkhill Malnutrition Scoring tool(PYMS)and the clinical data questionnaire.Results:A total of 492 children in PICU were enrolled.The first nutritional risk screening results showed that there were 32 cases of no/low nutritional risk(6.5%),76 cases of medium risk(15.4%),and 384 cases of high risk(78.1%).The incidence of medium/high nutritional risk was as high as 93.5%.The PYMS score of nutritional risk in PICU was(2.61±1.42).The results of multiple linear regression analysis showed that weight,fever time before admission,white blood cells,body mass index,primary diagnosis,father's education,and diet before illness were the main influencing factors of nutritional risk of children in PICU(P<0.05).Conclusion:Children in PICU are in a state of high nutritional risk.It is suggested that children in PICU should carry out nutritional screening in a standardized manner,identify children with high nutritional risk and its influencing factors early.To actively conduct nutritional assessment and nutritional intervention could improve the clinical outcome of children in PICU.
10.Changes in the body shape and ergonomic compatibility for functional dimensions of desks and chairs for students in Harbin during 2010-2024
Chinese Journal of School Health 2025;46(3):315-320
Objective:
To analyze the change trends in the body shape indicators and proportions of students in Harbin from 2010 to 2024, and to investigate ergonomic compatibility of functional dimensions of school desks and chairs with current student shape indicators, so as to provide a reference for revising furniture standards of desks and chairs.
Methods:
Between September and November of both 2010 and 2024, a combination of convenience sampling and stratified cluster random sampling was conducted across three districts in Harbin, yielding samples of 6 590 and 6 252 students, respectively. Anthropometric shape indicators cluding height, sitting height, crus length, and thigh length-and their proportional changes were compared over the 15-year period. The 2024 data were compared with current standard functional dimensions of school furniture. The statistical analysis incorporated t-test and Mann-Whitney U- test.
Results:
From 2010 to 2024, average height increased by 1.8 cm for boys and 1.5 cm for girls; sitting height increased by 1.5 cm for both genders; crus length increased by 0.3 cm for boys and 0.4 cm for girls; and thigh length increased by 0.5 cm for both genders. The ratios of sitting height to height, and sitting height to leg length increased by less than 0.1 . The difference between desk chair height and 1/3 sitting height ranged from 0.4-0.8 cm. Among students matched with size 0 desks and chairs, 22.0% had a desk to chair height difference less than 0, indicating that the desk to chair height difference might be insufficient for taller students. The differences between seat height and fibular height ranged from -1.4 to 1.1 cm; and the differences between seat depth and buttock popliteal length ranged from -9.8 to 3.4 cm. Among obese students, the differences between seat width and 1/2 hip circumference ranged from -20.5 to -8.7 cm, while it ranged from -12.2 to -3.8 cm among non obese students.
Conclusion
Current furniture standards basically satisfy hygienic requirements; however, in the case of exceptionally tall and obese students, ergonomic accommodations such as adaptive seating allocation or personalized adjustments are recommended to meet hygienic requirements.


Result Analysis
Print
Save
E-mail