1.Genetic analysis of a de novo EFTUD2 variant causing Mandibulofacial dysostosis with microcephaly in a fetus.
Jianyu REN ; Xiaojiao GUAN ; Shuang LIU ; Yousheng YAN ; Shufa YANG
Chinese Journal of Medical Genetics 2026;43(4):288-294
OBJECTIVE:
To investigate the genetic etiology of a fetus diagnosed with Mandibulofacial dysostosis with microcephaly (MFDM).
METHODS:
A fetus that underwent prenatal diagnosis at Beijing Obstetrics and Gynecology Hospital, Capital Medical University, on May 19, 2025 was selected for analysis. Results of fetal ultrasound findings, chromosomal karyotyping, copy number variation sequencing (CNV-seq), and whole-exome sequencing (WES) were collected. Sanger sequencing was performed for familial validation of the pathogenic variant. The Human Protein Atlas (HPA), STRING, and Simple ClinVar databases were queried to characterize the biological features of the candidate gene. Three-dimensional structures of the wild-type and variant proteins were modeled and analyzed, and the evolutionary conservation of the affected amino acid was assessed using UGENE. Prenatal phenotypes associated with EFTUD2 variants were summarized through a review of the literature. This study was approved by the Ethics Committee of Beijing Obstetrics and Gynecology Hospital, Capital Medical University (Ethics No.: 2025-KY-029-01).
RESULTS:
At 23+2 weeks of gestation, ultrasound examination revealed bilateral microtia with low-set ears, mild micrognathia with a reduced mandibular-facial angle, a single umbilical artery, a slightly narrow aortic diameter, and trivial mitral regurgitation. Amniotic fluid karyotyping and CNV-seq showed no abnormalities. WES identified a de novo, previously unreported EFTUD2 variant, c.698dupA (p.V235Gfs*27), in the fetus. This frameshift variant is predicted to alter the structural integrity of the EFTUD2 protein. Literature review indicated that micrognathia and microtia or low-set ears are the most common sonographic features in fetuses with EFTUD2 variants, while secondary findings may include abnormal stomach bubble, cleft palate, single umbilical artery, gastrointestinal atresia, polyhydramnios, and reduced aortic diameter.
CONCLUSION
The EFTUD2: c.698dupA (p.V235Gfs*27) variant is likely the genetic cause underlying MFDM in this fetus.
Humans
;
Mandibulofacial Dysostosis/diagnostic imaging*
;
Microcephaly/diagnostic imaging*
;
Female
;
Pregnancy
;
Ribonucleoprotein, U5 Small Nuclear/chemistry*
;
Peptide Elongation Factors/chemistry*
;
Fetus
;
DNA Copy Number Variations/genetics*
;
Adult
;
Ultrasonography, Prenatal
2.Thyroid Hormone Network Regulation in MASLD: Mechanisms and Targeted Therapies
Wen-Ping XIAO ; Yang MA ; Heng GUAN ; Sha WAN ; Wen HAN ; Bing-Bing LUO ; Wu-Feng WANG ; Fang LIU
Progress in Biochemistry and Biophysics 2026;53(3):643-661
Metabolic dysfunction-associated steatotic liver disease (MASLD) has become the most prevalent chronic liver disease worldwide, affecting approximately 32%-38% of the adult population and posing a growing public health burden. MASLD represents a continuous disease spectrum ranging from simple steatosis to metabolic dysfunction-associated steatohepatitis (MASH), progressive hepatic fibrosis, cirrhosis, and ultimately hepatocellular carcinoma (HCC). The pathological core of MASLD lies in disruption of hepatic lipid metabolic homeostasis, characterized by an imbalance among de novo lipogenesis, fatty acid β-oxidation, and very-low-density lipoprotein (VLDL)-mediated lipid export. This metabolic disequilibrium subsequently drives inflammatory injury and fibrotic progression. Among the multiple regulatory pathways involved, thyroid hormone (TH) signaling has emerged as a central regulator of hepatic metabolic homeostasis. The liver is a major peripheral target organ of TH action, where TH predominantly exerts its metabolic effects through thyroid hormone receptor β (TRβ). Large-scale epidemiological studies and meta-analyses have demonstrated that hypothyroidism is significantly associated with increased MASLD prevalence, more severe histological injury, and advanced hepatic fibrosis, suggesting that dysregulation of TH signaling may participate throughout the entire MASLD disease spectrum. At the molecular level, TH regulates hepatic lipid metabolism by coordinating suppression of lipogenesis, enhancement of mitochondrial fatty acid oxidation, and promotion of VLDL assembly and secretion through integrated genomic actions of the T3-TRβ axis and non-genomic signaling pathways. Across different stages of MASLD, TH signaling exerts stage-dependent protective effects. In the steatosis stage, TH improves metabolic flexibility by modulating insulin sensitivity, glucose metabolism, and lipid droplet clearance, thereby alleviating early lipotoxic stress. During progression to MASH, TH attenuates inflammatory amplification by improving mitochondrial homeostasis, suppressing activation of the NOD-like receptor family pyrin domain containing 3 (NLRP3) inflammasome, and modulating the gut-liver axis microenvironment. In advanced stages, TH signaling influences hepatic stellate cell activation and extracellular matrix deposition, partly through interaction with the transforming growth factor-β (TGF-β)/SMAD pathway, while alterations in intrahepatic TH availability, mediated by dynamic changes in iodothyronine deiodinase 1 (DIO1), contribute to fibrosis progression and hepatocellular dedifferentiation. In hepatocellular carcinoma, coordinated downregulation of TRβ and DIO1 establishes a tumor-associated hypothyroid state that promotes metabolic reprogramming and tumor progression. The clinical relevance of TH signaling in MASLD has been underscored by the recent approval of Resmetirom, a liver-targeted TRβ‑selective agonist, for the treatment of non-cirrhotic MASH with moderate-to-severe fibrosis (F2-F3). This approval represents a landmark transition from mechanistic understanding to metabolism-centered precision therapy in MASLD. Clinical trials have demonstrated that Resmetirom not only improves key histological endpoints, including MASH resolution and fibrosis regression, but also favorably modulates atherogenic lipid profiles, highlighting the therapeutic potential of selectively targeting hepatic TH pathways. This review systematically summarizes the multidimensional regulatory roles of TH across the MASLD disease spectrum and discusses emerging diagnostic and therapeutic implications of TH-based interventions, aiming to inform future mechanistic research and optimize clinical management strategies.
3.Feasibility of optimizing radiation dose for three-dimensional printing of the maxillofacial bone based on low-dose CT technology
Guan LI ; Haopeng WANG ; Jinbao WANG ; Xinhao SONG ; Guochu QIN ; Yang SHAO
Chinese Journal of Tissue Engineering Research 2026;30(6):1384-1389
BACKGROUND:Maxillofacial bone three-dimensional(3D)printing technology has been widely used in clinical diagnosis and treatment,but the data source before performing maxillofacial bone 3D printing mainly comes from the CT scanning data.The lens,thyroid and other parts of the human body are extremely sensitive to X-rays;therefore,it is particularly important to effectively reduce the dose of CT radiation when acquiring the data source.OBJECTIVE:To explore the feasibility of low-dose CT technology in optimizing radiation dose for maxillofacial bone 3D printing.METHODS:The medical records of 65 patients who underwent maxillofacial bone 3D printing in the Department of Stomatology at the General Hospital of Northern Theater Command from March 2021 to December 2023 were retrospectively collected and categorized into a conventional CT-dose 3D printing group(conventional CT-dose,120 kVp,automated tube current modulation,n=32)and a low-CT-dose 3D printing group(low-CT-dose group,80 kVp,automated tube current modulation,n=33).The effective dose of radiation was calculated and compared between the two groups.A Likert scale was used to evaluate the quality of 3D printing in the two groups,and the measurement bias and consistency between evaluators were measured using the Bland-Altman method.RESULTS AND CONCLUSION:(1)There was no significant difference in the general demographic characteristics(age,height,weight,body mass,sex,and body mass index)between the two groups(all P>0.05).(2)The effective dose value of the low CT-dose 3D printing group was(0.3±0.1)mSv,which was about 62.5%lower than that in the conventional CT-dose 3D printing group[(0.8±0.1)mSv].(3)There was no significant difference in the subjective scoring of 3D printing quality between the two groups(all P>0.05).The subjective consistency among evaluators was good,with Kappa values of 0.85,0.80,and 0.76.The scatter points in the Bland-Altman for both protocols were uniformly distributed within the standard deviation line,indicating good consistency between the two groups.To conclude,low-dose CT technology can be effectively applied in maxillofacial bone 3D printing,reducing radiation dose without affecting the quality of 3D printing.
4.Analysis of the current situation and influencing factors of platelet supply in medical institutions
Xuan WU ; Ting ZHANG ; Xiaozhen GUAN ; Yang YU
Chinese Journal of Blood Transfusion 2026;39(3):339-345
Objective: To systematically analyze the current status and influencing factors of platelet supply in medical institutions across China, and to explore the problems and future development directions of the existing supply models. Methods: From February 25 to March 5, 2025, a web-based questionnaire survey was performed. A self-designed questionnaire was distributed to staff in the blood transfusion departments of medical institutions nationwide in China. Data on the current status and influencing factors of platelet supply were collected and analyzed. Results: A total of 2 268 responses were collected in this survey, with 1 366 valid questionnaires finally included, covering 33 provinces, autonomous regions, and municipalities directly under the central government across China. The survey revealed that platelet supply in Chinese medical institutions exhibited a pattern of "sufficient in the eastern region, stable in the central region, and scarce in the western region": adequate in East China; generally favorable in South China except Guangxi; centered on Beijing and Tianjin in North China; basically met but with insufficient reserves in Central China; subject to seasonal fluctuations in Northeast China; only meeting the baseline supply in Yunnan, Guizhou, and Sichuan in Southwest China; and notably short in Qinghai, Ningxia, and Xinjiang in Northwest China. Family donor mobilization was required in 81.2% (1 109/1 366) of institutions, whereas this proportion was only 12.7% (173/1 366) among institutions with sufficient supply. Tertiary hospitals constituted the main users, among which tertiary Class A hospitals had the highest sufficiency rate, and secondary Class B hospitals showed the most pronounced shortage. A total of 84% (1 147/1 366) of institutions lacked a professional management team; only 19% (266/1 366) had an inventory warning system, of which 88% (234/266) considered it effective. Platelet reservation required 3 days in 33% (458/1 366) of institutions. The mandatory transfusion rate was 30.55% (29/118) when the reservation lead time exceeded 3 days, representing an increase of 5.98% compared with 24.57% (55/180) in the same-day reservation group. For optimization, most institutions called for improved blood donation services, strengthened education and incentives, establishment of regional coordination and policy collaboration, and supplementary suggestions focused on technologies for extending platelet shelf life. Conclusion: Regional imbalance in platelet supply across China is prominent, with supply shortages in some provinces, reliance on family donor mobilization in most institutions, weak grassroots support capacity, imperfect management systems, and supply timeliness constraining clinical practice. Systematic improvements are needed in optimizing blood donation services, strengthening regional coordination, improving relevant policies, and developing platelet preservation technologies, so as to enhance the level of supply security and patient safety.
5.IL-22 impairs NK cell function and promotes cisplatin resistance in bladder cancer cells via activating the STAT3 signaling axis
YANG Yunjie1 ; CHEN Yang2 ; LIU Qi3 ; GUAN Lixian2 ; LIANG Gengqi2
Chinese Journal of Cancer Biotherapy 2026;33(3):280-287
[摘 要] 目的:探讨IL-22通过STAT3信号轴损害NK细胞功能并促进膀胱癌细胞耐药的机制。方法:常规培养T24细胞,用梯度递增法构建耐药T24/顺铂(DDP)细胞。将细胞分为对照组(不处理)、DDP组、IL-22组、IL-22 + DDP组、IL-22 + anti-IL-22组、IL-22 + DDP + Stattic(STAT3抑制剂)组。qPCR法检测各组T24细胞中IL-22、cyclin D1、Bcl-2 mRNA的表达,WB法检测各组细胞中BAX、BCL2和p-STAT3的表达,CCK-8法检测各组细胞的增殖活性,流式细胞术检测各组细胞的凋亡,ELISA检测各组细胞上清液中乳酸脱氢酶(LDH)、TNF-α、IFN-γ、颗粒酶B(GzmB)和穿孔素(PRF)蛋白的水平。结果:T24/DDP细胞对DDP敏感性降低(P < 0.05);其耐药相关基因P-糖蛋白(P-gp)、肺耐药蛋白(LRP)、多药耐药相关蛋白1(MRP1)和IL-22及其受体表达水平均明显升高(均P < 0.05),说明T24/DDP细胞构建成功。与对照组比较,DDP组T24细胞的增殖活力明显降低、凋亡率升高、BAX蛋白表达升高、BCL2表达下降(均P < 0.05);与DDP组比较,IL-22 + DDP组T24细胞的增殖活明显升高、凋亡率明显下降、BAX蛋白表达降低、BCL2表达升高(均P < 0.05),表明IL-22通过调节BAX/Bcl-2的表达促进T24细胞对DDP耐药性。与对照组比较,IL-22组T24细胞总细胞和核中p-STAT3表达水平均明显升高(均P < 0.05);与IL-22组比较,IL-22 + anti IL-22组T24细胞中 p-STAT3水平明显降低(P < 0.05),说明IL-22激活T24细胞中STAT3的磷酸化过程,并促进其转核。与对照组比较,DDP组T24与NK92细胞共培养上清液中LDH、TNF-α、IFN-γ、GzmB及PRF蛋白水平均明显升高(均P < 0.05),与DDP组比较,IL-22 + DDP组共培养上清液中上述蛋白水平均明显降低(均P < 0.05);与对照组比较,IL-22组共培养上清液中LDH、TNF-α、IFN-γ、GzmB及PRF蛋白水平明显降低(均P < 0.05);与IL-22组比较,IL-22 + Stattic组共培养上清液中上述蛋白水平均明显升高(均P < 0.05),说明IL-22可降低NK92细胞对T24细胞的毒性,STAT3抑制剂可逆转此作用。与DDP组比较,IL-22 + DDP组T24细胞增殖活力明显升高(P < 0.05);与IL-22 + DDP组比较,IL-22 + DDP + Stattic组T24细胞增殖活力明显降低(P < 0.05);与DDP组比较,IL-22 + DDP组T24细胞的凋亡率明显升高(P < 0.05);与IL-22 + DDP组比较,IL-22 + DDP + Stattic组T24细胞的凋亡率明显升高(P < 0.05),说明IL-22调控STAT3影响T24细胞DDP耐药性及NK细胞免疫功能。结论: IL-22通过激活STAT3信号轴促进T24细胞的DDP耐药性,抑制NK细胞功能。
6.Efficacy and safety of CT-guided radiofrequency ablation as a surgical alternative for multiple pulmonary nodules
Changhui MA ; Bin ZHANG ; Linxiang YU ; Zhong GUAN ; Junyi YANG ; Haiwen ZHEN
Chinese Journal of Clinical Medicine 2026;33(2):299-305
Objective To evaluate the efficacy and safety of CT-guided percutaneous radiofrequency ablation (RFA) as an alternative for video-assisted thoracoscopic surgery (VATS) in treating multiple pulmonary nodules. Methods A retrospective analysis was conducted on the clinical data of 113 patients with multiple pulmonary nodules admitted to Jiangsu Provincial Hospital of Traditional Chinese Medicine from October 2020 to October 2022. The patients were divided into the RFA group (n=50) and the VATS group (n=63) based on the treatment method. Perioperative indicators (operation time, intraoperative blood loss, postoperative length of hospital stay), oncological outcomes (recurrence-free survival [RFS], overall survival [OS]), and postoperative complication rates were compared between the two groups. Univariate and multivariate Cox regression analysis was performed to identify independent prognostic factors. Results The operation time in the RFA group was significantly shorter than that in the VATS group ([75.2±20.1] min vs [102.3±28.7]) min, P<0.001). No statistically significant differences were observed in intraoperative blood loss and postoperative length of hospital stay. After follow-up of 24 (12, 30) months, no statistically significant differences were found in RFS (HR=1.25, P=0.445) or OS (HR=1.42, P=0.402) between the two groups. Mixed ground-glass nodules with high solid component and solid nodule were identified as independent risk factors for RFS (HR=2.44, P=0.023; HR=2.97, P=0.007) and OS (HR=2.87, P=0.022; HR=3.43, P=0.005) in patients with multiple pulmonary nodules. The total complication rate in the RFA group was lower than that in the VATS group (12.0% vs 34.9%, P=0.009). Conclusions The efficacy of CT-guided RFA in treating multiple pulmonary nodules is comparable to that of VATS, with good safety, and it shows promise as an alternative to surgical treatment for multiple pulmonary nodules.
7.Feasibility of optimizing radiation dose for three-dimensional printing of the maxillofacial bone based on low-dose CT technology
Guan LI ; Haopeng WANG ; Jinbao WANG ; Xinhao SONG ; Guochu QIN ; Yang SHAO
Chinese Journal of Tissue Engineering Research 2026;30(6):1384-1389
BACKGROUND:Maxillofacial bone three-dimensional(3D)printing technology has been widely used in clinical diagnosis and treatment,but the data source before performing maxillofacial bone 3D printing mainly comes from the CT scanning data.The lens,thyroid and other parts of the human body are extremely sensitive to X-rays;therefore,it is particularly important to effectively reduce the dose of CT radiation when acquiring the data source.OBJECTIVE:To explore the feasibility of low-dose CT technology in optimizing radiation dose for maxillofacial bone 3D printing.METHODS:The medical records of 65 patients who underwent maxillofacial bone 3D printing in the Department of Stomatology at the General Hospital of Northern Theater Command from March 2021 to December 2023 were retrospectively collected and categorized into a conventional CT-dose 3D printing group(conventional CT-dose,120 kVp,automated tube current modulation,n=32)and a low-CT-dose 3D printing group(low-CT-dose group,80 kVp,automated tube current modulation,n=33).The effective dose of radiation was calculated and compared between the two groups.A Likert scale was used to evaluate the quality of 3D printing in the two groups,and the measurement bias and consistency between evaluators were measured using the Bland-Altman method.RESULTS AND CONCLUSION:(1)There was no significant difference in the general demographic characteristics(age,height,weight,body mass,sex,and body mass index)between the two groups(all P>0.05).(2)The effective dose value of the low CT-dose 3D printing group was(0.3±0.1)mSv,which was about 62.5%lower than that in the conventional CT-dose 3D printing group[(0.8±0.1)mSv].(3)There was no significant difference in the subjective scoring of 3D printing quality between the two groups(all P>0.05).The subjective consistency among evaluators was good,with Kappa values of 0.85,0.80,and 0.76.The scatter points in the Bland-Altman for both protocols were uniformly distributed within the standard deviation line,indicating good consistency between the two groups.To conclude,low-dose CT technology can be effectively applied in maxillofacial bone 3D printing,reducing radiation dose without affecting the quality of 3D printing.
8.Influence of chronic psychological stress during pregnancy on intestinal flora and eczema incidence of offspring rats
Chunyan WANG ; Ying GAO ; Deguang YANG ; Rui WANG ; Hongyu LI ; Ye LI ; Can LIU ; Suzhen GUAN
Journal of Environmental and Occupational Medicine 2025;42(8):962-970
Background Prenatal chronic psychological stress may increase the risk of allergic diseases in children, and eczema is the most common allergic disease in children, the pathogenesis of which is not yet fully understood. Objective To preliminarily clarify the changes in offspring intestinal flora after chronic stress exposure during pregnancy in rats that increases offspring immune imbalance and eczema susceptibility. Methods Thirty SPF-grade adult female SD rats were selected and randomly divided into a model group and a control group (n=15). Sixteen male rats were randomly divided into a model mating group and a control mating group (n=8). A 28-day chronic unpredictable mild stress (CUMS) model during pregnancy was established. On the 7th day of stress, male and female rats were caged in a ratio of 3:1. Blood samples were collected from female rats in each group via angular vein on the 1st day before stress, and on the 7th, 14th, 21st, and 28th days after stress. The content of plasma corticosterone during pregnancy was determined by enzyme-linked immunosorbent assay (ELISA). For the offspring rats, an eczema model was constructed using 2,4-dinitrochlorobenzene (DNCB). The number of scratching times of the offspring rats within 5 min was recorded. The offspring rats were divided into 4 groups: DNCB-CUMS group (MM), DNCB-control group (MC), solvent control-CUMS group (CM), and blank control group (CC), with 8 rats in each group. The eczema was induced once every 3 days, and the induction period was 12 d. The expression level of immunoglobulin E (IgE) in the serum of offspring rats after the eczema induction experiment were determined by ELISA. The concentrations of tumor necrosis factor-α (TNF-α), interferon-γ (IFN-γ), interleukin-2 (IL-2), interleukin-4 (IL-4), and interleukin-13 (IL-13) in the serum were quantified by multi-parameter flow cytometry. The composition and abundance of intestinal microbiota in the feces of offspring rats were detected by 16S rRNA high-throughput sequencing technology. Results The plasma corticosterone concentrations in the model group were higher than those in the control group on the 7th and 21st days of stress (P<0.05). On the 14th and 21st days of stress, the 1% sucrose preference percentages of female rats in the model group were lower than that in the control group. On the 7th, 14th, and 21st days of stress, the horizontal movement scores of female rats in the model group and the vertical movement scores on the 7th and 14th days were lower than those in the control group (P<0.05). After 6, 9, and 12 d of model building, the scratching frequencies in the MC group and MM group were significantly higher than those in the CC group and CM group (P<0.05). Moreover, there were differences in the contents of cytokines including IFN-γ, IL-2, TNF-α, IL-4, IL-13, and IgE among the offspring rat groups (P<0.05). The CM group and MM group led to an increase in the contents of TNF-α, IL-4, IL-13, and IgE cytokines (P<0.05), while the MM group caused a decrease in the contents of IFN-γ and IL-2 (P<0.05). After the eczema induction experiment, the α-diversity analysis showed that the Simpson index and Shannon index in the CM were higher than those in the CC (P<0.05), indicating that CUMS during the pregnancy of female rats could increase the species abundance of their offspring. The abundances of Prevotella and Lactobacillus in the CM group decreased (P<0.05). Conclusion Intestinal dysbiosis in offspring due to chronic prenatal psychological stress, which may be one of the mechanisms linking maternal stress to immune imbalance and increased susceptibility to eczema in offspring.
9.Cost-effectiveness of angiographic quantitative flow ratio-guided coronary intervention: A multicenter, randomized, sham-controlled trial.
Yanyan ZHAO ; Changdong GUAN ; Yang WANG ; Zening JIN ; Bo YU ; Guosheng FU ; Yundai CHEN ; Lijun GUO ; Xinkai QU ; Yaojun ZHANG ; Kefei DOU ; Yongjian WU ; Weixian YANG ; Shengxian TU ; Javier ESCANED ; William F FEARON ; Shubin QIAO ; David J COHEN ; Harlan M KRUMHOLZ ; Bo XU ; Lei SONG
Chinese Medical Journal 2025;138(10):1186-1193
BACKGROUND:
The FAVOR (Comparison of Quantitative Flow Ratio Guided and Angiography Guided Percutaneous Intervention in Patients with Coronary Artery Disease) III China trial demonstrated that percutaneous coronary intervention (PCI) lesion selection using quantitative flow ratio (QFR) measurement, a novel angiography-based approach for estimating fractional flow reserve, improved two-year clinical outcomes compared with standard angiography guidance. This study aimed to assess the cost-effectiveness of QFR-guided PCI from the perspective of the current Chinese healthcare system.
METHODS:
This study is a pre-specified analysis of the FAVOR III China trial, which included 3825 patients randomized between December 25, 2018, and January 19, 2020, from 26 centers in China. Patients with stable or unstable angina pectoris or those ≥72 hours post-myocardial infarction who had at least one lesion with a diameter stenosis between 50% and 90% in a coronary artery with a ≥2.5 mm reference vessel diameter by visual assessment were randomized to a QFR-guided strategy or an angiography-guided strategy with 1:1 ratio. During the two-year follow-up, data were collected on clinical outcomes, quality-adjusted life-years (QALYs), estimated costs of index procedure hospitalization, outpatient cardiovascular medication use, and rehospitalization due to major adverse cardiac and cerebrovascular events (MACCE). The primary analysis calculated the incremental cost-effectiveness ratio (ICER) as the cost per MACCE avoided. An ICER of ¥10,000/MACCE event avoided was considered economically attractive in China.
RESULTS:
At two years, the QFR-guided group demonstrated a reduced rate of MACCE compared to the angiography-guided group (10.8% vs . 14.7%, P <0.01). Total two-year costs were similar between the groups (¥50,803 ± 21,121 vs . ¥50,685 ± 23,495, P = 0.87). The ICER for the QFR-guided strategy was ¥3055 per MACCE avoided, and the probability of QFR being economically attractive was 64% at a willingness-to-pay threshold of ¥10,000/MACCE avoided. Sensitivity analysis showed that QFR-guided PCI would become cost-saving if the cost of QFR were below ¥3682 (current cost: ¥3800). Cost-utility analysis yielded an ICER of ¥56,163 per QALY gained, with a 53% probability of being cost-effective at a willingness-to-pay threshold of ¥85,000 per QALY gained.
CONCLUSION:
In patients undergoing PCI, a QFR-guided strategy appears economically attractive compared to angiographic guidance from the perspective of the Chinese healthcare system.
TRIAL REGISTRATION
ClinicalTrials.gov , NCT03656848.
Humans
;
Cost-Benefit Analysis
;
Percutaneous Coronary Intervention/methods*
;
Male
;
Female
;
Coronary Angiography/methods*
;
Middle Aged
;
Aged
;
Coronary Artery Disease/surgery*
;
Quality-Adjusted Life Years
;
Fractional Flow Reserve, Myocardial/physiology*
10.Utility of upper urinary tract video urodynamics in recurrent symptoms and equivocal hydronephrosis after ureteral reconstruction: A retrospective cohort study.
Xinfei LI ; Yiming ZHANG ; Liqing XU ; Chen HUANG ; Zhihua LI ; Kunlin YANG ; Hua GUAN ; Jing LIU ; Peng ZHANG ; Hongjian ZHU ; Liqun ZHOU ; Xuesong LI
Chinese Medical Journal 2025;138(18):2350-2352

Result Analysis
Print
Save
E-mail