1.Comparison of setup errors between two postural fixation methods in radiotherapy for breast cancer
Fukui HUAN ; Yu ZHAO ; Chao LIU ; Gengqiang ZHU ; Ruiao ZHAO ; Yongtai ZHENG ; Yandong GE ; Bao WAN ; Bin LIANG
Chongqing Medicine 2025;54(4):921-925
Objective To compare the positioning errors and the motion of acromioclavicular joint in breast cancer patients with integrated cervicothoracic thermoplastic membrane and breast bracket fixation,and to provide reference for accurate irradiation of upper and lower clavicular region.Methods Sixty-three pa-tients with breast cancer who were treated in the radiotherapy center of the hospital from November 1,2021 to August 9,2023 were selected as the study objects,and were divided into the integrated cervicothoracic thermo-plastic membrane group(n=32)and breast bracket group(n=31)according to different positioning meth-ods.The translation errors of left and right direction(X),head and foot direction(Y)and ventral and dorsal direction(Z)and the rotation errors of sagittal plane(Rx),cross section(Ry)and coronal plane(Rz)of the two groups were analyzed,and the movement amplitude and three-dimensional displacement of acromioclavic-ular joint were measured respectively.Results Compared with the breast bracket group,X translation errors[(0.18±0.14)cm vs.(0.15±0.12)cm]and Z translation errors[(0.19±0.14)cm vs.(0.16±0.14)cm]of the cervicothoracic thermoplastic memberane group were greater,Z translation error[(0.21±0.17)cm vs.(0.22±0.21)cm]and Rx rotation error of cervical and sternoclavicular joints[(0.93±0.87)° vs.(1.08±0.92)°]were smaller,Rz rotation error[(1.00±0.94)° vs.(0.95±0.86)°]was greater,and the motion ΔX of acromioclavicular joint[(0.18±0.15)cm vs.(0.25±0.21)cm]was smaller,the difference was statistically significant(P<0.05).Conclusion Integrated cervicothoracic thermoplastic membrane can be used as a solu-tion for prophylactic irradiation of breast cancer in the upper and lower clavicular region and for radiation leak-age in the presence of metastasis.
2.Analysis of setup errors of postoperative intensity-modulated radiotherapy immobilized with integrated cervicothoracic board (mask) system in breast cancer patients
Yanxin ZHANG ; Fukui HUAN ; Gengqiang ZHU ; Ke ZHOU ; Xin FENG ; Bao WAN ; Yu TANG ; Hao JING ; Shulian WANG ; Jianrong DAI
Chinese Journal of Radiation Oncology 2021;30(8):835-840
Objective:To investigate the setup errors of postoperative radiotherapy immobilized with integrated cervicothoracic board (mask) system in breast cancer patients.Methods:Thirty-two breast cancer patients treated with postoperative radiotherapy immobilized with integrated cervicothoracic board (mask) system were prospectively recruited in this study. Breast/chest wall (cw) and supra/infraclavicular nodal region (sc) were irradiated with intensity-modulated radiotherapy. CBCT location verification in radiotherapy and target areas of the breast/chest wall and upper and lower collarbone were carried out, respectively. The consistency between setup errors and the position of the upper and lower target areas of 239 CBCT images was analyzed.Results:The translational setup errors of the breast/chest wall in the X-cw (left-right), Y-cw (superior-inferior), Z-cw (anterior-posterior) directions were (1.84±2.36) mm, (1.99±2.48) mm, and (1.75±1.86) mm, respectively. The translational setup errors of the supra/infraclavicular nodal region in the X-sc (left-right), Y-sc (superior-inferior), Z-sc (anterior-posterior) directions were (1.98±2.44) mm, (1.98±2.48) mm, and (1.71±1.79) mm, respectively. The differences of translational setup errors between the breast/chest wall and supra/infraclavicular nodal region in the X, Y, Z directions were (0.38±0.66) mm, (0.07±0.41) mm, and (0.45±0.92) mm, respectively. Conclusion:For the breast cancer patients treated with postoperative radiotherapy covering breast/chest wall and supra/infraclavicular nodal region, the integrated cervicothoracic board (mask) immobilization system provides good reproducibility and yields Sfew setup errors.

Result Analysis
Print
Save
E-mail