1.Effectiveness of free fascia lata flap assisted by indocyanine green angiography in treatment of Myerson type Ⅱ and Ⅲ chronic Achilles tendon ruptures.
Liping GUO ; Rong ZHOU ; Jihui JU ; Guangzhe JIN ; Liang YANG ; Chao GENG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(5):620-627
OBJECTIVE:
To investigate of effectiveness of free fascia lata flap assisted by indocyanine green angiography (ICGA) in treatment of Myerson type Ⅱ and Ⅲ chronic Achilles tendon ruptures.
METHODS:
A clinical data of 14 patients with Myerson type Ⅱ and Ⅲ chronic Achilles tendon ruptures between March 2020 and June 2024 was retrospectively analyzed. All Achilles tendon defects were repaired with the free fascia lata assisted by ICGA during operation. There were 12 males and 2 females with an average age of 45.4 years (range, 26-71 years). The causes of Achilles tendon rupture included sports injury in 10 cases, Achilles tendon-related tendinopathy in 3 cases, and glass laceration injury in 1 case. The time from Achilles tendon rupture to operation was 4-40 weeks (median, 4.5 weeks). Preoperative MRI examination showed that the defect length of the Achilles tendon was 2-5 cm (mean, 3.2 cm). The operation time and intraoperative blood loss were recorded. The color Doppler ultrasound (CDU) and MRI were taken to observe the foot blood vessels and the tendon healing. The visual analogue scale (VAS) score, American Orthopaedic Foot and Ankle Society (AOFAS) score, Achilles Tendon rupture score (ATRS), and range of motion of the ankle joint were used to estimate the pain and function of ankle joint.
RESULTS:
All operations of the 14 patients were successfully completed. The operation time ranged from 3.00 to 4.50 hours (mean, 3.60 hours). The intraoperative blood loss ranged from 10 to 50 mL (mean, 36.4 mL). After operation, 1 patient had exudation at the recipient site, which healed after dressing change; the other incisions healed by first intention. All incisions at the donor sites healed by first intention. All patients were followed up 6-36 months (mean, 11.4 months). The CDU of the foot at 1 month after operation showed that the blood flow signal of the perforating vessels of the fascia lata flap was clear. The ankle MRI at 2 months after operation showed the good continuity of the Achilles tendon. No complication such as the Achilles tendon re-rupture, ankle stiffness, or scar contracture occurred during follow-up. Compared with preoperative score, the AOFAS score, ATRS score, and plantar flexion range of motion significantly increased at 1, 3, and 6 months after operation ( P<0.05), while the VAS score and dorsiflexion range of motion significantly decreased ( P<0.05). The AOFAS score, ATRS score, and VAS score at 3 and 6 months further improved when compared with those at 1 month ( P<0.05); however, there was no significant difference in the range of motion of the ankle joint ( P>0.05). There was no significant difference in above indicators between 3 and 6 months after operation ( P>0.05).
CONCLUSION
The treatment of Myerson type Ⅱ and Ⅲ chronic Achilles tendon ruptures with free fascia lata flaps under the guidance of ICGA has the advantages of precise design, fast healing, and a wide range of adaptability.
Humans
;
Achilles Tendon/diagnostic imaging*
;
Male
;
Female
;
Adult
;
Middle Aged
;
Retrospective Studies
;
Indocyanine Green
;
Rupture/surgery*
;
Aged
;
Fascia Lata/transplantation*
;
Angiography/methods*
;
Free Tissue Flaps/blood supply*
;
Plastic Surgery Procedures/methods*
;
Tendon Injuries/diagnostic imaging*
;
Treatment Outcome
;
Chronic Disease
2.Effectiveness of three-dimensional printing-assisted vascularized fibular graft for repairing metatarsal defects.
Rong ZHOU ; Jihui JU ; Liang YANG ; Liping GUO ; Yucheng LIU ; Chao GENG ; Zhongzheng LIU ; Zefeng NIU ; Shuai DONG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(11):1447-1451
OBJECITVE:
To investigate the effectiveness of three-dimensional (3D) printing-assisted vascularized fibular graft for repairing metatarsal defects.
METHODS:
Between November 2021 and February 2024, 11 patients with varying degrees of metatarsal defects caused by trauma were treated. There were 10 males and 1 female, aged 22-67 years, with a mean age of 51.2 years. The defect locations were as follows: the first metatarsal in 4 cases, the fifth metatarsal in 2 cases, the first and the second metatarsals in 1 case, the first to third metatarsals in 1 case, the third and the fourth metatarsals in 1 case, the third to fifth metatarsals in 1 case, and the first to fifth metatarsals in 1 case. The preoperative American Orthopaedic Foot & Ankle Society (AOFAS) score was 67.0 (48.5, 72.5). Based on 3D-printed bilateral feet models and mirrored healthy-side foot arch angles for preoperative planning and design, the vascularized fibular graft was performed to repair the metatarsal defects. At last follow-up, the medial and lateral longitudinal arches of bilateral feet were measured on weight-bearing X-ray films, and functional assessment was conducted using the AOFAS score.
RESULTS:
All operations were successfully completed, with an operation time ranging from 180 to 465 minutes (mean, 246.8 minutes). All incisions healed by first intention, with no occurrence of osteomyelitis. All patients were followed up 6-22 months (mean, 10 months). X-ray film reviews showed bone graft healing in all cases, with a healing time of 3-6 months (mean, 5 months). All patients underwent internal fixator removal at 6-12 months after operation. At last follow-up, no significant difference was observed in the medial and lateral longitudinal arches between the healthy and affected feet ( P>0.05). The AOFAS score of the affected foot was 78.0 (73.5, 84.0), showing a significant improvement compared to the preoperative score ( P<0.05). The effectiveness was rated as excellent in 1 case, good in 7 cases, fair in 2 cases, and poor in 1 case. Linear scarring remained at the donor site, with no functional impairment in adjacent joint movement.
CONCLUSION
3D printing-assisted vascularized fibular graft for repairing metatarsal defects can effectively restore the physiological angle of the foot arch, facilitate the recovery of weight-bearing alignment, promote good bone healing, and yield satisfactory clinical outcomes.
Humans
;
Printing, Three-Dimensional
;
Middle Aged
;
Male
;
Fibula/blood supply*
;
Female
;
Metatarsal Bones/injuries*
;
Adult
;
Bone Transplantation/methods*
;
Aged
;
Plastic Surgery Procedures/methods*
;
Young Adult
;
Treatment Outcome
3.Construction and evaluation of a cell model simulating the change of testicular microenvironment mediated by hypoxic and high-pressure conditions in varicocele mice.
Shu-Lin LIANG ; Li-Guo GENG ; Ling HAN ; Chu-Nan RONG ; Zhan QIN ; Juan DU ; Chao-Ba HE ; Shao-Ying YUAN
National Journal of Andrology 2025;31(6):483-491
Objective: Varicocele (VC) induces male infertility by mediating changes in the testicular microenvironment, in which testicular hypoxia and high-pressure are important pathological conditions. This study aims to compare the mouse spermatogenesis (GC-2spd) cells and Sertoli (TM4) cells of mouse testis after hypoxic modeling and hypoxic and high-pressure combined modeling, and to explore the feasibility of establishing a hypoxic and high-pressure combined cell model. Methods: On the basis of cell hypoxia induced by CoCl2, the complex model of testicular cell hypoxia and high pressure was constructed by changing the osmotic pressure of GC-2 and TM4 cell medium with a high concentration of NaCl solution. After selecting the intervention concentration of CoCl2 by MTT test and detecting the expression level of HIF-1α for the determination of the optimal osmotic pressure conditions of the cell model, the cells were divided into normal group, hypoxia model group and composite model group. And the levels of OS, programmed cell death, inflammatory factors, and the expression levels of pyroptosis-related proteins were compared between the normal group and the groups with different modeling methods. Results: The optimal intervention concentration of CoCl2 in GC-2 and TM4 cells was 150 and 250μmol/L, respectively, and the expression of HIF-1α was the highest in both cells under osmotic pressure of 500 mOsmol/kg (P<0.05). Compared with the normal group, the SOD levels of GC-2 and TM4 cells decreased (all P<0.05), CAT level decreased (all P<0.05), and MDA level increased (all P<0.01), and the OS level of GC-2 and TM4 cells was more obvious than that of the hypoxia model group (all P<0.05). Compared with the normal group, apoptosis occurred in GC-2 and TM4 cells after composite modeling (all P<0.05). Compared with the normal group, the mRNA expressions of IL-1β, IL-18, TNF-α and COX-2 in GC-2 and TM4 cells significantly increased (P<0.01) and higher than those in hypoxia model group (P<0.05) and induced pyroptosis (P<0.01). The expression level of GSDMD increased (P<0.05). Conclusion: The cell model with hypoxia and high pressure combined modeling can not only induce oxidative stress and apoptosis of cells better than that with hypoxia alone, but also further cause inflammatory response damage and pyroptosis, which simulates the changes of testis microenvironment mediated by hypoxia and high pressure combined conditions in VC. This cell model can be used for studying the pathogenesis of VC-associated male infertility, evaluating drug efficacy, and exploring pharmacological mechanisms.
Male
;
Animals
;
Varicocele/pathology*
;
Mice
;
Testis/metabolism*
;
Hypoxia-Inducible Factor 1, alpha Subunit/metabolism*
;
Cell Hypoxia
;
Cobalt
;
Sertoli Cells/metabolism*
;
Osmotic Pressure
;
Spermatogenesis
;
Cellular Microenvironment
;
Infertility, Male
;
Disease Models, Animal
4.Construction of teaching system based on artificial intelligence and standardized cancer radiotherapy case library
Lin LEI ; Nan DAI ; Mengxia LI ; Rong HE ; Chuan CHEN ; Mingying GENG ; Yanli XIONG
Chinese Journal of Medical Education Research 2024;23(4):492-495
The current situation of tumor radiotherapy teaching is far behind the development of radiotherapy technologies. The construction of a teaching system based on an artificial intelligence-powered automatic target delineation system and a standardized cancer radiotherapy case library is operable and practical for realizing the standardization and homogenization of clinical target volume delineation teaching, improving students' precision and speed of target volume delineation, and promoting students' learning interest, initiative, and efficiency, which can bring new vitality to the development of radiotherapy education and is worthy of further exploration and promotion.
5.Early identification of acute kidney injury in children with primary nephrotic syndrome
Jie GAO ; Chao-Ying CHEN ; Juan TU ; Hai-Yun GENG ; Hua-Rong LI ; Jin-Shan SUN ; Nan-Nan WANG ; Yong-Li HUANG
Chinese Journal of Contemporary Pediatrics 2024;26(9):921-925
Objective To investigate the incidence and risk factors for acute kidney injury(AKI)in children with primary nephrotic syndrome(PNS),as well as the role of neutrophil gelatinase-associated lipocalin(NGAL)and kidney injury molecule-1(KIM-1)in the early identification of AKI in these children.Methods A prospective collection of clinical data from children hospitalized with PNS at the Children's Hospital of the Capital Institute of Pediatrics from January 2021 to October 2022 was conducted.The children were divided into two groups based on the presence of AKI:the AKI group(47 cases)and the non-AKI group(169 cases).The risk factors for AKI in children with PNS were identified by multivariate logistic regression analysis.Urinary KIM-1 and NGAL levels were compared between the AKI and non-AKI groups,as well as among the different stages of AKI.Results The incidence of AKI in children with PNS was 21.8%.Multivariate logistic regression analysis revealed that steroid-resistant nephrotic syndrome,gastrointestinal infections,and heavy proteinuria were independent risk factors for AKI in these children with PNS(P<0.05).Urinary KIM-1 and NGAL levels were higher in the AKI group compared to the non-AKI group(P<0.05),and the urinary NGAL and KIM-1 levels in the AKI stage 2 and stage 3 subgroups were higher than those in the AKI stage 1 subgroup(P<0.017).Conclusions KIM-1 and NGAL can serve as biomarkers for the early diagnosis of AKI in children with PNS.Identifying high-risk populations for AKI in children with PNS and strengthening the monitoring of related risk factors is of significant importance.
6.Diagnostic value of high-resolution MRI for nerve root compression in lumbar intervertebral foramen stenosis
Yuxin HE ; Rong WU ; Ligang GENG ; Shili HE ; Gaofeng ZHANG
Journal of Practical Radiology 2024;40(5):781-784
Objective To explore the correlation value of high-resolution MRI on the cause,location and degree of nerve root com-pression and clinical symptoms of lumbar intervertebral foramen stenosis.Methods Patients with sciatic neuralgia underwent con-ventional MRI examination of the lumbar spine before treatment.MRI thin layer(1 mm)intervertebral disc axial scan was performed on patients with suspected L4/L5 and L5/S1 intervertebral foramen stenosis,and the value of conventional MRI and high-resolution MRI on intervertebral foramen stenosis location,etiology and Elisabeth typing was compared and analyzed.Intervertebral foramen mor-phometric indicators,nerve root length and short diameter were measured on high-resolution MRI post-processed images and their correlation with visual analogue scale(VAS)scores of clinical symptoms was analyzed.Results Sixty-one patients were effectively diagnosed with intervertebral foramen stenosis and nerve root compression after surgery or conservative treatment.The diagnosis rate of conventional MRI for the cause of intervertebral foramen stenosis was 75.4%,and the diagnosis rate of high-resolution MRI post-processed was 91.8%.The Elisabeth typing of lumbar intervertebral foramen stenosis was positively correlated with clinical symp-toms,while the nerve root short diameter and peri-nerve fat space area were negatively correlated with VAS score.Conclusion High-resolution MRI is significantly better than conventional MRI for the diagnosis of nerve root compression in intervertebral fora-men stenosis.It visually shows the location,cause and degree of nerve root compression,which can better guide the clinical and accu-rate minimally invasive surgery.
7.Immunobiological characteristics of peripheral blood MAIT cells in chil-dren with influenza
Geng-Ji XIAO ; Jing LIU ; Ru-Ping LUO ; Fu-Rong LIU ; Tao JIANG
Chinese Journal of Infection Control 2024;23(5):582-585
Objective To investigate the changes and clinical significance of peripheral blood mucosal-associated invariant T(MAIT)cells in children with influenza.Methods Children with influenza who received treatment in the outpatient and inpatient departments of a children's hospital from January to May 2023 were selected and divided into the common type group and the severe type group.Healthy children who underwent physical examination in this hospital during the same period were selected as the healthy control group.Within 24 hours after admission,children's venous blood was drawn for testing;ratios of MAIT cells(CD3+CD161+TCRVα7.2+cells)and MAIT cells expressing PD-1,CD69,perforin,and CD107 α were tested by flow cytometry,respectively.Differences among all the groups were compared.Results Compared with the control group,the proportion of peripheral blood MAIT cells in children with common and severe influenza gradually decreased,while the proportion of CD69-ex-pressing and perforin-positive MAIT cells increased gradually.Differences were statistically significant(all P<0.05).There was no statistically significant difference in the proportion of MAIT cells expressing CD107(P>0.05).The proportion of PD-1 positive MAIT cells increased(P<0.05),but there was no statistically significant difference be-tween the common type and severe type groups(P>0.05).Conclusion The decrease of peripheral blood MAIT cells accompanied with immune activation plays a role in the pathogenesis of influenza.
8.Performance evaluation of PET/CT based on silicon photomultiplier and photomultiplier tube under clinical imaging conditions
Xuesong SU ; Jianhua GENG ; Yibin WANG ; Xuejuan WANG ; Rong ZHENG ; Jing LI
Chinese Journal of Radiological Medicine and Protection 2024;44(5):428-435
Objective:To investigate the spatial resolution and image quality of positron emission tomography and X-ray computed tomography (PET/CT) based on the next-generation silicon photomultiplier (SiPM) and the conventional photomultiplier tube (PMT) and to explore the effects of different PET photoelectric transducers (PMT and SiPM) and the Q. Clear algorithm on the spatial resolution, quantitative accuracy, and image quality of PET/CT.Methods:GE Discovery Elite PET/CT (PMT PET/CT) and GE Discovery Meaningful Insights (MI) PET/CT (SiPM PET/CT) were employed to scan the elliptical resolution phantom and NEMA NU2-2018 image quality phantom. Using the OSEM+ PSF+ TOF (VPFX-S) algorithm, image reconstruction was performed based on raw data of both phantoms. For the MI-acquired phantom data, additional reconstructions were conducted using the Q. Clear algorithm, with β values ranging from 150 to 550 and an increment of 100. For the elliptical resolution phantom, the radial, tangential, and axial full-width at half-maximum (FWHM) values of five line sources in three slices were calculated and averaged. For the image quality phantom, the recovery coefficient (RC), contrast recovery coefficient (CRC), contrast-to-noise ratio (CNR), percentage of background variability (PBV), background coefficient of variability (BCV) of the spheres, as well as the residual error (RE) of lung inserts at different image slices, were calculated.Results:Compared to Elite, MI (VPFX-S) showed decreases in the radial, tangential, and axial FWHM of 4.25%-13.58%, 7.00%-13.22%, and 6.02%-36.14%, respectively; no significant difference in RCmax for the spheres; increases in spheres′ CRC and CNR of 10.17%-38.89% and 38.31%-94.95%, respectively, and decreases in spheres′ PBV and BCV of 26.20%-33.82% and 31.29%-35.97%, respectively. When compared to MI (VPFX-S), MI (Q.Clear) showed decreases in the radial, tangential, and axial FWHM of 6.49%-45.02%, 7.80%-35.60%, and 13.31%-36.80%, respectively; an increase in spheres′ CNR of 38.31%-94.95%; decreases in spheres′ PBV and BCV of 26.20%-33.82% and 6.64%-10.31%, respectively, and no significant difference in spheres′ RC. With an increase in the β value, the CNR, RE, and FWHM in radial, tangential, and axial directions derived from MI (Q.Clear) increased, while RC, CRC, PBV, and BCV decreased. Conclusions:Under image reconstruction using VPFX-S, the next-generation SiPM PET/CT exhibits elevated spatial resolution, hot lesion contrast, detectability, and background noise compared to the PMT PET/CT. Compared to OSEM, the Q. Clear algorithm improves spatial resolution, quantitative accuracy, and image quality, with such improvement related to the β value. The β value affects the outcomes of the Q. Clear algorithm, especially the maximum quantitative value of small lesions. This is particularly important for improving clinical diagnostic capabilities.
9.Research advance in preparation and functional modification of porous polytetrafluoroethylene artificial blood vessels
Rong XU ; Haojie WANG ; Mengxiang GENG ; Kai MENG ; Hui WANG ; Keqin ZHANG ; Huijing ZHAO
Chinese Journal of Tissue Engineering Research 2024;28(5):759-765
BACKGROUND:Medium-and large-diameter polytetrafluoroethylene artificial blood vessels have been widely used in clinical practice.However,most of the products were imported from other countries.Small-diameter porous polytetrafluoroethylene vessels are easy to form thrombosis and intimal hyperplasia,resulting in an extremely low long-term patency rate,which is difficult to fulfill clinical requirements. OBJECTIVE:To review and summarize the research progress of polytetrafluoroethylene in the field of artificial blood vessels,which can provide a reference for the functional modification of small-diameter polytetrafluoroethylene artificial blood vessels and the improvement of their long-term patency rate. METHODS:The relevant articles published from October 2022 to March 2023 in CNKI,Web of Science,Wiley Online Library,SpringerLink,Science Direct and IOP Science databases were searched by the first author.The search terms in Chinese were"porous polytetrafluoroethylene,vascular graft,electrospinning,medical application,functional modification".The search terms in English were"ePTFE,porous polytetrafluoroethylene,vascular graft,electrospinning,medical application,functional modification".All the articles about the preparation and modification of polytetrafluoroethylene artificial blood vessels were retrieved. RESULTS AND CONCLUSION:The preparation and functional modification of porous polytetrafluoroethylene artificial blood vessels were still research hotspots and difficult problems.From the research progress in and outside China in recent years,the preparation of porous polytetrafluoroethylene artificial blood vessels mainly adopted the rapid thermal stretching method,but the preparation of polytetrafluoroethylene artificial blood vessels by electrospinning was a promising new method.By analyzing and summarizing different functional modification methods,it was found that the long-term patency rate of porous polytetrafluoroethylene artificial blood vessels had been improved.However,the functional modification of small-diameter polytetrafluoroethylene artificial blood vessels still needed further exploration and optimization.
10.Acceptance test of PET/CT based on national standard and the NEMA measurement program
Xuesong SU ; Jianhua GENG ; Chaokun ZHANG ; Hao GUO ; Rong ZHENG ; Xuejuan WANG
China Medical Equipment 2024;21(2):16-22
Objective:To perform acceptance test and performance assessment for Siemens Biograph Vision 600 positron-emission tomography/computed tomography(PET/CT)according to the national health industry standard WS 817-2023.Methods:Spatial resolution,sensitivity,scatter fraction,count loss and random coincidence,correction accuracy of count loss and random coincidence,time-of-flight(TOF)resolution of the PET component within the PET/CT system were tested through the measurement program(NU2-2018)of National Electrical Manufacturers Association(NEMA),which was installed inside of the equipment,in accordance with the requirement of national health industry standard WS 817-2023.The PET/CT registration accuracy was measured through Gantry_offset acquisition program that was built into the equipment.Results:The transversely and axially spatial resolutions of Biograph Vision 600 PET/CT were respectively 3.69 mm and 4.10 mm at 1 cm away from the center of visual field,and were respectively 4.26 mm and 4.89 mm at 10 cm away from the center of visual field,and were respectively 4.68 mm and 4.89 mm at 20 cm away from the center of visual field.The sensitivity of 10 cm away from center and radial of visual field were respectively 16.12 kcps/MBq and 16.00 kcps/MBq.The peak value of noise equivalent count rate(NECR)was 281.60 kcps,and the corresponding radioactivity concentration of peak value was 30.69 kBq/ml.The NECR peak value,scatter fraction and maximum value of the error of relative count rate were respectively 38.17% and 4.0%.The TOF resolution was 209.87 ps when the radioactivity concentration was 5.3 kBq/mL.The registration accuracy values of Biograph Vision 600 PET/CT were 0.347 mm,-0.226 mm and 3.659 mm at the directions of x,y and z axis.Conclusion:It is feasible to perform the acceptance test according to the WS 817-2023 standard through uses the NEMA NU2-2018 standard measurement program that is installed inside of the equipment.The performance indicators can meet requirement of standard as the current national standard GB/T 18988.1-2013 and the health industry standard WS 817-2023 that will being implemented in the test of Biograph Vision 600 PET/CT,which can pass acceptance.

Result Analysis
Print
Save
E-mail