1.Application of digital health technologies in upper limb motor function rehabilitation after stroke from 2015 to 2025: a bibliometric analysis
Rui LIU ; Zhenmei GAO ; Xingyu ZHOU ; Qi ZHANG ; Jianlin WU
Chinese Journal of Rehabilitation Theory and Practice 2026;32(5):534-549
ObjectiveTo analyze the current research status, hotspots and future trends of the application of digital health technology (DHT) in the rehabilitation of upper limb motor function after stroke. MethodsRelevant literature on the application of DHT in upper limb motor rehabilitation for stroke patients published between January, 2015 and December, 2025 was retrieved from Web of Science Core Collection, CNKI and Wanfang database. CiteSpace 6.4.R1 was used for visualized bibliometric analysis. ResultsA total of 1 295 publications were included, comprising 454 in Chinese and 841 in English. The annual number of publications generally showed an upward trend. China ranked first in publication output in English literature. The institutions with the highest numbers of publications were Huashan Hospital Affiliated to Fudan University and Swiss Federal Institute of Technology in Zurich. Both Chinese and English keywords formed ten clustering groups. Chinese clusters mainly involved occupational therapy, neural mechanisms and home-based rehabilitation, whereas English clusters focused on virtual reality, brain-computer interfaces and machine learning. High-frequency keywords included virtual reality, brain-computer interface, machine learning and deep learning. Chinese keywords with a strong burst included rehabilitation training, while deep learning showed a strong burst in English keywords. Stroke was the most frequently cited journal. Highly cited journals covered multiple disciplines, including rehabilitation medicine, neuroscience and computer science, reflecting the interdisciplinary characteristics of this field. ConclusionResearches on DHT for upper limb motor function rehabilitation in stroke are increasing annually, focusing on core interaction technologies, neural mechanism and artificial intelligence. Future research trends may include inter-disciplinary integration of artificial intelligence with core rehabilitation technologies, neuroimaging-guided targeted interventions, optimisation of home-based rehabilitation systems, and development of multidimensional quantitative assessment models.
2.Construction of a community-family management model for older adults with mild cognitive impairment
Junli CHEN ; Han ZHANG ; Yefan ZHANG ; Yanqiu ZHANG ; Runguo GAO ; Qianqian GAO ; Weiqin CAI ; Haiyan LI ; Lihong JI ; Zhiwei DONG ; Qi JING
Chinese Journal of Rehabilitation Theory and Practice 2026;32(1):90-100
ObjectiveTo develop a community-family management model for older adults with mild cognitive impairment (MCI) and to formulate detailed application specifications, and to fully leverage the initiative of communities and families under limited resource conditions, for achieving community-based early detection and early intervention for older adults with MCI. MethodsA systematic literature review was conducted to identify pertinent publications. Corpus-based research methodologies were employed to extract, refine, integrate and synthesize management elements, thereby establishing the specific content and service processes for each stage of the management model. Utilizing the 5W2H analytical framework, essential elements such as management stakeholders, target populations, content and methods for each stage were delineated. The model and its application guidelines were finalized through expert consultation and demonstration. ResultsAn expert evaluation of the management model yielded mean scores of 4.84, 4.32 and 4.84 for acceptability, feasibility and systematicity, respectively. By integrating the identified core elements with expert ratings and feedback, the final iteration of the community-family management model for older adults with MCI was formulated. This model comprised of five stages: screening and identification, comprehensive assessment, intervention planning, monitoring and referral pathways to ensure implementation, and enhanced support for communities, family members and caregivers. Additionally, it included 18 specific application guidelines. ConclusionThe proposed management model may theoretically help delay cognitive decline, improve cognitive function and potentially promote reversal from MCI to normal cognition. It may also enhance the awareness and coping capacity of older adults and their families, strengthen community healthcare professionals' ability to early identify and manage MCI.
3.Clinical Advantages of Traditional Chinese Medicine in Treatment of Childhood Simple Obesity: Insights from Expert Consensus
Qi ZHANG ; Yingke LIU ; Xiaoxiao ZHANG ; Guichen NI ; Heyin XIAO ; Junhong WANG ; Liqun WU ; Zhanfeng YAN ; Kundi WANG ; Jiajia CHEN ; Hong ZHENG ; Xinying GAO ; Liya WEI ; Qiang HE ; Qian ZHAO ; Huimin SU ; Zhaolan LIU ; Dafeng LONG
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(6):238-245
Childhood simple obesity has become a significant public health issue in China. Modern medicine primarily relies on lifestyle interventions and often suffers from poor long-term compliance, while pharmacological options are limited and associated with potential adverse effects. Traditional Chinese Medicine (TCM) has a long history in the prevention and management of this condition, demonstrating eight distinct advantages, including systematic theoretical foundation, diversified therapeutic approaches, definite therapeutic efficacy, high safety profile, good patient compliance, comprehensive intervention strategies, emphasis on prevention, and stepwise treatment protocols. Additionally, TCM is characterized by six distinctive features: the use of natural medicinal substances, non-invasive external therapies, integration of medicinal dietetics, simple exercise regimens, precise syndrome differentiation, and diverse dosage forms. By combining internal and external treatments, TCM facilitates individualized regimen adjustment and holistic regulation, demonstrating remarkable effects in improving obesity-related metabolic indicators, regulating constitutional imbalance, and promoting healthy behaviors. However, challenges remain, such as inconsistent operational standards, insufficient high-quality clinical evidence, and a gap between basic research and clinical application. Future efforts should focus on accelerating the standardization of TCM diagnosis and treatment, conducting multicenter randomized controlled trials, and fostering interdisciplinary integration, so as to enhance the scientific validity and international recognition of TCM in the prevention and treatment of childhood obesity.
4.Deep learning image reconstruction algorithm in brain CT perfusion imaging with low tube voltage and reduced contrast agent dosage
Mengyuan ZHANG ; Luotong WANG ; Dian YUAN ; Yicun ZHANG ; Ke QI ; Weiting ZHANG ; Jiong ZHANG ; Songwei YUE ; Jianbo GAO ; Jie LIU
Chinese Journal of Medical Imaging Technology 2025;41(5):799-805
Objective To observe the value of deep learning image reconstruction(DLIR)algorithm in brain CT perfusion(CTP)using a protocol of 70 kVp and 40 ml contrast agent dose.Methods Totally 105 patients with suspected acute ischemic stroke(AIS)were prospectively enrolled and randomly divided into 3 groups,who underwent standard dose CTP scanning with 80 kVp and 150 mA combined with reconstruction as adaptive statistic iterative reconstruction V(ASIR-V)at 50%level(CN group,n=35),low dose(LD)scanning with 70 kVp and 100 mA combined with DLIR reconstruction at the highest level(DLIR-H)(LD group,n=35),or ultra-low dose(ULD)scanning with 70 kVp and 70 mA combined with DLIR-H reconstruction(ULD group,n=35).Radiation doses were compared among 3 groups.CT values and standard deviations(SDCT)of ROI of gray matter and white matter in the frontal,parietal and temporal lobes were measured.Signal-to-noise ratio(SNR)and contrast-to-noise ratio(CNR)between gray and white matter were calculated and compared among groups.Then pseudo-color images of cerebral blood volume(CBV),cerebral blood flow(CBF),mean transit time(MTT)and time to maximum of the tissue residual function(Tmax)were generated.The imaging quality of CTP pseudo-color images was evaluated,and the compatibility of the subjective scores within every kind of CTP pseudo-color images were assessed using Kappa test.Quantitative perfusion parameters were measured and compared among groups.Results Compared with CN group,both LD and ULD groups demonstrated significantly reduced volume CT dose index(CTDIvol),dose-length product(DLP)and effective dose(ED)(all adjusted P<0.05).In ULD group,SDCT of white matter in frontal,parietal and temporal lobes were higher than those in CN group,and SDCT of white matter in parietal lobe was also higher than that in LD group(all adjusted P<0.05).No significant difference of SDCT of gray matter was observed among groups(all P>0.05).SNR of white matter in parietal and temporal lobes in both LD and ULD groups were lower than those in CN group(all P<0.05),while no significant difference of SNR of white matter in frontal lobe,nor of gray matter in frontal,parietal and temporal lobes was found among groups(all P>0.05).CNR of gray and white matter in the frontal,parietal and temporal lobes were not significantly different among groups(all P>0.05).High consistency of inter-observer subjective scores of CBV maps,CBF maps and Tmax maps(Kappa of 0.623,0.644 and 0.638,respectively)were noticed,which of MTT maps had moderate consistency(Kappa=0.560).No significant difference of intra-obsever subjective scores of CTP pseudo-color images was found among groups(all P>0.05).CBV,CBF,MTT and Tmax values of gray and white matter in frontal,parietal and temporal lobes were not significantly different among groups(all P>0.05).Conclusion DLIR algorithm applicated in low radiation dose and reduced contrast agent dosage might ensure imaging quality.
5.Comparison of the toxicity and safety of protein derivatives from novel fusion strains of Mycobacterium tuberculosis
Hao-qi XU ; Jiang-tao DONG ; Jie ZHANG ; Fang WU ; Su LIANG ; Xiao-ling LIU ; Lan-ru GAO ; Ju WANG ; Hui ZHANG ; Jiang-dong WU ; Le ZHANG ; Xi-ling DENG ; Wan-jiang ZHANG
Chinese Journal of Zoonoses 2025;41(4):376-384
The objective of this study was to evaluate the toxicity and safety of novel Mycobacterium tuberculosis fusion strain protein derivatives,referred to as B/R strain active proteins.In cellular experiments,RAW264.7 cells were treated with each vaccine preparation,and apoptosis rates were measured.In subsequent animal experiments,C57BL/6 mice were immunized via subcutaneous injection,and their survival and body weight changes were monitored and recorded at 2,4,8,12,and 16 weeks.The lungs and spleens were harvested to calculate organ coefficients,and pathological examinations were conducted.At the eighth week of immunization,the mice were infected with high concentrations of BCG,and pathological changes in the lungs and spleens were observed 4 weeks post-infection.The apoptosis rate at 6 hours was significantly higher in the experimental group than the PBS group(P<0.05).At 12 and 24 hours,the apoptosis rate in the experimental group remained higher than that in the PBS group,although this difference was not statistically significant.After immunization,mice in all four groups exhibited normal growth patterns,as indicated by stable body weight changes.At 4 and 12 weeks post-immunization,the lung coefficients in the protein group were significantly higher than those in the PBS group at the same time points.Additionally,the lung coefficients in the BCG group were significantly elevated across all time periods(P<0.05).The spleen coefficients in the protein and BCG groups were significantly higher than those in the PBS group at 2,4,8,12,and 16 weeks,whereas the ICD B/R group showed higher spleen coefficients than the PBS group only at week 8(P<0.05).Pathological examination revealed normal lung and spleen tissues in the PBS group.However,during the 2-8 weeks immunization period,lung and spleen tissues in all experimental groups exhibited varying degrees of damage,which gradually diminished by 12-16 weeks.Notably,no tuberculosis nodules were observed in any experimental group.After infection with high concentrations of BCG,no overt pathological changes were observed on the surfaces of the lungs and spleens in any group.Microscopic examination revealed less severe pathological changes in the lungs and spleens of mice in the experimental groups than the PBS group.Furthermore,no statistically significant differences were observed between the protein group and the BCG group.Our findings suggested that the B/R strain active proteins'toxicity and safety profiles were comparable to those of BCG,and showed immunoprotective effects.This study provides an experimental foundation for the development of a novel tuberculosis vaccine.
6.Discussion on the implementation effect of the integrated traditional Chinese and western medicine DRG payment model in traditional Chinese medicine hospitals
Xiuling GAO ; Zhitao LIU ; Xiaomin JIANG ; Shantao ZHANG ; Jihu ZHONG ; Ruwei ZHANG ; Jiyuan SHI ; Peng QI ; Yanzheng QU
Modern Hospital 2025;25(6):910-912,916
Objective To explore and analyze the implementation effect of the combined traditional Chinese medicine(TCM)and Western medicine DRG payment model in TCM hospitals,aiming to provide a reference for the reform of medical in-surance payment methods in such hospitals.Methods R language was utilized to statistically analyze the costs and other indica-tors of the sample hospitals before and after the implementation of the combined TCM and Western medicine DRG payment within 1-2 years.Results Following the implementation of the combined TCM and Western medicine DRG payment,there was a de-crease in average hospitalization costs and average length of stay,accompanied by an increase in CMI(average weight).The cost structure underwent changes:the proportions of western medicine fees and auxiliary examination fees decreased,whereas the pro-portion of TCM treatment fees increased.Significant statistical differences were observed in each group of data(p<2.2e-16).Conclusion The combined TCM and Western medicine DRG payment reform model can facilitate TCM hospitals in reducing medical costs,controlling medical expenses,optimizing the cost structure,and promoting the development of TCM diagnosis and treatment characteristics.
7.Establishment and assessment of deep vein thrombosis model in rats in a plateau hypoxic environment
Xiaobo HAN ; Yahao CHAI ; Jiawei GAO ; Xinkai DENG ; Xiao LI ; Jialin WU ; Xiaoli HAN ; Guoxiang LI ; Yinjie ZHAO ; Xi YANG ; Qi AO ; Lei ZHANG ; Hongwei HAN ; Zhixue LIU
Acta Laboratorium Animalis Scientia Sinica 2025;33(8):1133-1143
Objective To establish a rat model of venous thrombosis in a plateau hypobaric hypoxic environment and to investigate the effect of this environment on venous thrombosis.Methods A total of 144 healthy male SD rats were assigned randomly to four groups(n=36 rats per group):a plains sham operation(A)group,plains operation(B)group,plateau altitude 6000 m+sham operation(C)group,and plateau altitude 6000 m+surgery(D)group.Rats in A and B groups were maintained in a plains normoxic environment,while rats in C and D groups C and D were subjected to a plateau environment.Rats in the surgical groups underwent quantitative constriction to incompletely obstruct the inferior vena cava blood flow.Each group was further divided into subgroups based on time:1,3,5,7,14,and 21 d(n=6 rats per group).Regular vascular ultrasound monitoring was conducted,and blood samples were taken for whole blood viscosity testing and the assessment of inflammatory indicators,including endothelin-1(ET-1),interleukin-6(IL-6)and tissue factor(TF).Coagulation function was evaluated through the activated partial thromboplastin time(APTT),prothrombin time(PT),thrombin time(TT),fibrinogen(FIB)and D-dimer.After the observation period,the experimental animals were sacrificed and the limbs were removed.Thrombus samples were stained with hematoxylin/eosin(HE),and the thrombus wet mass was measured.Results The thrombosis incidence was significantly higher in the plateau D group than in B group,accompanied by a marked increase in blood viscosity and hematocrit(P<0.01).Additionally,levels of ET-1,IL-6,and TF were significantly elevated(P<0.05),indicating a coagulation disorder.Conclusions A plateau hypoxic environment model can be successfully simulated by quantitative coarctation of the inferior vena cava,combined with a specialized environmental chamber.The findings of this study suggest that a plateau hypoxic environment promotes venous thrombosis.
8.Modulation of microglia by traditional Chinese medicine improves post-stroke depression
Qi LI ; Jing GAO ; Ming ZHANG ; Xu ZHANG ; Yachen FENG ; Rui PAN ; Chunxiao WANG ; Qiongdi REN
The Journal of Practical Medicine 2025;41(18):2945-2952
Post-stroke depression(PSD),a common stroke complication characterized by depressed mood and diminished interest,severely affects patients'recovery and quality of life.Microglial abnormal activation and polarization play key roles in PSD pathogenesis,closely associated with neuroinflammation and imbalance in neu-rotransmitter metabolism.In contrast,traditional Chinese medicine(TCM)demonstrates unique multi-target and multi-level mechanisms:regulating microglial function,ameliorating post-stroke neuroinflammatory environments,and promoting neuroplasticity,thereby potentially alleviating PSD symptoms.This review summarizes TCM's effects on microglial activation/polarization states and its therapeutic advances in PSD,providing novel perspectives and strategies for clinical management.
9.Photon-counting detector CT with virtual monoenergetic imaging in enabling a quadruple low-dose aortic CT angiography protocol: a feasibility study
Ke QI ; Kehui NIE ; Dian YUAN ; Yicun ZHANG ; Mengyuan ZHANG ; Weiting ZHANG ; Yanbo GU ; Yan CHEN ; Jianbo GAO ; Jie LIU
Chinese Journal of Radiology 2025;59(10):1133-1141
Objective:To assess the viability of reducing radiation dose, contrast media volume, injection flow rate and contrast medium concentration (quadruple low-dose protocol) by utilizing virtual monoenergetic images (VMI) in photon-counting detector CT (PCD-CT) for aortic CT angiography (CTA), while maintaining image quality in comparison to images obtained from energy-integrating detector CT (EID-CT).Methods:From April 2024 to June 2024, a total of 40 participants who underwent aortic CTA on PCD-CT were prospectively enrolled in the experimental group (PCD-CT group), while 40 patients with similar baseline characteristics who had previously undergone aortic CTA using EID-CT were retrospectively selected for the conventional group (EID-CT group). The EID-CT group used a tube voltage of 90 kVp, a contrast media volume of 60 ml of contrast, an injection flow rate of 3 ml/s, and a contrast concentration of 350 mgI/ml; the PCD-CT group used the QuantumPlus mode, with a tube voltage of 140 kVp, a total amount of iodine in the contrast media of 140 mgI/kg, and an injection flow rate=contrast media volume/(delay time+scan time), and a contrast media concentration of 320 mgI/ml. VMIs in PCD-CT group were reconstructed in 5-keV intervals ranging from 45 to 65 keV. The effective radiation dose and contrast injection protocols were recorded and compared between two groups. Objective image quality assessment was performed for each group. CT attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured at five anatomical locations (ascending aorta, aortic arch, descending aorta, abdominal aorta, and right common iliac artery), and image noise was recorded. Subjective image quality was independently evaluated by two readers using a 5-point Likert scale in a blinded manner. Based on data normality, the one-way ANOVA or Kruskal-Wallis test was used for image quality assessment, with Bonferroni-corrected post-hoc analysis for multiple comparisons.Results:There were no significant differences in the baseline characteristics between two groups (all P0.05). The PCD-CT group demonstrated significantly lower effective radiation dose [(3.88±0.65) mSv vs. (5.97±1.15)mSv], contrast media volume [(29.25±4.56) ml vs. 60 ml], and injection rate [(2.65±0.42) ml/s vs. 3 ml/s] than the EID-CT group, with reductions of 35%, 51%, and 12%, respectively (all P0.001). For objective image quality, except for the ascending aortic CT attenuation, the CT attenuation, SNR, and CNR of other vessels in the 55 keV PCD-CT group were comparable to those in the EID-CT group. Additionally, the difference in image noise between these two groups was not statistically significant ( P0.05). Concerning subjective image quality, at 55 keV, the PCD-CT group had similar image noise scores and vessel attenuation scores (both P0.05) and better visualization of renal artery branching ( P=0.001) compared to the EID-CT group. Conclusion:In comparison to EID-CT, the use of a 55 keV image in PCD-CT for aortic CTA has demonstrated reductions in radiation dose, contrast media volume, injection flow rate and contrast medium concentration, while maintaining image quality.
10.Feasibility study of photon counting CT combined with “quadruple lows” technology in head and neck vascular imaging
Mengyuan ZHANG ; Kehui NIE ; Dian YUAN ; Yicun ZHANG ; Ke QI ; Weiting ZHANG ; Yanbo GU ; Yan CHEN ; Jianbo GAO ; Jie LIU
Chinese Journal of Radiology 2025;59(8):942-948
Objective:To evaluate the feasibility of head and neck vascular imaging using photon-counting detector computed tomography (PCD-CT) combined with a “quadruple lows” protocol—characterized by low contrast media volume, low iodine concentration, low injection rate, and low radiation dose—and to compare the image quality with that obtained by energy-integrating detector CT (EID-CT).Methods:A total of 105 patients with suspected cerebrovascular disease were prospectively enrolled at the First Affiliated Hospital of Zhengzhou University between April and June 2024. Patients were randomly assigned to three groups ( n=35). Group A underwent conventional head and neck CTA using EID-CT. Group B underwent PCD-CT with a protocol involving ultra-low contrast media volume, low iodine concentration, and low injection rate. Group C underwent PCD-CT with the full “quadruple low” protocol. Objective image quality parameters—including CT attenuation, image noise (standard deviation, SD), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR)—were measured at the ascending aorta, common carotid artery, internal carotid artery, vertebral artery, basilar artery, posterior cerebral artery, and middle cerebral artery. Two radiologists independently rated subjective image quality using a 5-point Likert scale. Differences among groups were analyzed using one-way ANOVA and the Kruskal-Wallis test. Results:Compared to Group A [contrast volume: (42.78±6.64)ml], contrast agent volume was significantly reduced in Groups B and C[ (26.26±4.45) ml and (26.54±3.83)ml, respectively], demonstrating reductions of 39% and 38% (both P<0.01). The iodine concentration was 320 mg/ml in Groups B and C, lower than 350 mg/ml in Group A (8.5%). The injection rate was also reduced in Groups B and C [(3.39±0.61) and (3.55±0.51)ml/s, respectively] compared to Group A [(4.28±0.66) ml/s], with reductions of 21% and 17% (both P<0.01). The effective dose (ED) was similar between Groups A and B [(1.40±0.15) vs. (1.40±0.19)mSv, P>0.05], while Group C demonstrated a significantly lower ED [(0.99±0.09) mSv], with a reduction of 30% compared to Group A and 29% compared to Group B (both P<0.01).In terms of objective image quality, significant differences in image noise (SD) were observed among the three groups at the vertebral artery, internal carotid artery, posterior cerebral artery, and middle cerebral artery (all P<0.05). Groups B and C showed significantly lower SD compared to Group A ( P<0.05), with no significant difference between B and C ( P>0.05). SNR was significantly higher in Groups B and C than in Group A at multiple vascular segments (all P<0.05). CNR differed only at the internal carotid artery, where Groups B and C demonstrated superior performance compared to Group A ( P<0.05).Subjective image quality scores showed no significant difference between Groups A and C ( P>0.05), while Group B had significantly higher scores than both A and C ( P<0.05). All images were deemed diagnostically acceptable. Conclusion:Compared with conventional EID-CT, PCD-CT combined with a “quadruple lows” protocol enables substantial reductions in contrast media and radiation dose while further improving image quality in head and neck CTA.

Result Analysis
Print
Save
E-mail