1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Physiological characteristics of the choroid and its association with myopia in children and adolescents
Chinese Journal of School Health 2024;45(2):296-299
Abstract
The choroid is a multifunctional dynamic structure located between the sclera and the Bruch membrane, which may be involved in the regulation of eye growth and the development of myopia. Choroidal thickness may serve as an important biomarker for predicting the development of myopia and the effectiveness of myopia control treatments in children and adolescents. The study reviews and summarizes the physiological structure and measuring methods of the choroid, and discusses its influencing factors including age, physiological changes, refractive status, axial length, drug effects, optical environment and so on. The review points out the potential applications of choroidal thickness in myopia research among children and adolescents.
7.Structure-based development of potent and selective type-II kinase inhibitors of RIPK1.
Ying QIN ; Dekang LI ; Chunting QI ; Huaijiang XIANG ; Huyan MENG ; Jingli LIU ; Shaoqing ZHOU ; Xinyu GONG ; Ying LI ; Guifang XU ; Rui ZU ; Hang XIE ; Yechun XU ; Gang XU ; Zheng ZHANG ; Shi CHEN ; Lifeng PAN ; Ying LI ; Li TAN
Acta Pharmaceutica Sinica B 2024;14(1):319-334
Receptor-interacting serine/threonine-protein kinase 1 (RIPK1) functions as a key regulator in inflammation and cell death and is involved in mediating a variety of inflammatory or degenerative diseases. A number of allosteric RIPK1 inhibitors (RIPK1i) have been developed, and some of them have already advanced into clinical evaluation. Recently, selective RIPK1i that interact with both the allosteric pocket and the ATP-binding site of RIPK1 have started to emerge. Here, we report the rational development of a new series of type-II RIPK1i based on the rediscovery of a reported but mechanistically atypical RIPK3i. We also describe the structure-guided lead optimization of a potent, selective, and orally bioavailable RIPK1i, 62, which exhibits extraordinary efficacies in mouse models of acute or chronic inflammatory diseases. Collectively, 62 provides a useful tool for evaluating RIPK1 in animal disease models and a promising lead for further drug development.
8.The value of high-throughput sequencing data reanalysis in identifying ERBB2 amplification in colorectal cancer patients
Min-Na SHEN ; Li ZHANG ; Xin-Ning CHEN ; Fei HUANG ; Chao-Gang BAI ; Li-Meng CHEN ; Hai-Xiang PENG ; Yan ZHOU ; Bei-Li WANG ; Bai-Shen PAN ; Wei GUO
Fudan University Journal of Medical Sciences 2024;51(2):166-171
Objective To evaluate the value of high-throughput sequencing(HTS)data reanalysis that does not include ERBB2 copy number variation(CNV)analysis,in identifying ERBB2 amplification in patients with colorectal cancer.Methods The HTS data of 252 cases of colorectal cancer diagnosed by pathological biopsy who received peripheral blood cfDNA HTS detection samples were retrospectively analyzed.According to the HTS data of ERBB2 non-amplified samples judged by immunohistochemistry(IHC)and/or fluorescence in situ hybridization(FISH),the number of chromosome 17(Chr17)reads in the total number of reads was calculated the range of the ratio was initially determined as the threshold for prompting ERBB2 amplification.Suspected positive samples were screened according to thresholds and verified by digital PCR,IHC and FISH.Results The proportion of the number of Chr17 reads accounts for the number of total reads in the 89 cases of ERBB2 non-amplified samples determined by IHC and/or FISH ranged from 0.188 to 0.299(0.239±0.192).Using 0.298(1.25 times the mean)as the threshold indicating ERBB2 amplification,the data of 163 samples were analyzed,of which 7 cases were suspected to be positive,and the ratio ranged from 0.302 to 0.853.Among them,5 cases were determined to be positive by IHC and/or FISH,and 6 cases were confirmed to be positive by digital PCR.The ratio of the number of Chr17 reads to the number of total reads was positively correlated with the ratio of ERBB2/EIF2C1,and the correlation was good(r2=0.909).Conclusion The high-throughput sequencing data that does not cover the ERBB2 CNV analysis has a certain hint value for ERBB2 amplification in patients with colorectal cancer.
9.Analysis of intercomparison results of national biological dose estimation capability in 2022
Yan PAN ; Jianlei RUAN ; Gang GAO ; Chunnan PIAO ; Jianxiang LIU
Chinese Journal of Radiological Medicine and Protection 2024;44(3):223-227
Objective:To improve the ability of radiation health technical institutions for biological dose estimation.Methods:A total of 144 institutions nationwide, including the CDC, prevention and treatment center for occupational disease, colleges and universities, scientific research institutes, nuclear industry systems, and medical and physical examination institutions, were organized to carry out the intercomparison of national biological dose estimation capabilities in 2022. The institutions participating in the comparison were divided into two types of A and B, through the identification of chromosome aberrations, to estimate the irradiation dose (A) or chromosome aberration rate (B). The results were summarized and compared, and the main problems were analyzed and discussed.Results:There were 60 institutions in type A, 52 qualified institutions (including 12 excellent institutions) and 8 unqualified institutions, with a pass rate of 86.7% (20.0% excellent) and a failure rate of 13.3%. There were 84 institutions participating in the biological dose estimation comparison of type B, with 48 qualified institutions, and 36 unqualified institutions, the qualified rate was 57.1%, and the unqualified rate was 42.9%.Conclusions:Most of the institutions participating in type A comparison have the ability to estimate biological dose, and more than half of the institutions participating in type B comparison have the ability to analyze chromosome aberration. The overall ability of institutions participating in type A comparison is higher than in type B.
10.Effects of occupational radiation exposure on peripheral blood lymphocyte count and cell cycle in logging workers
Weiguo LI ; Gang GAO ; Yan PAN ; Hailiang LI ; Jianlei RUAN ; Chunnan PIAO ; Jinghong FU ; Jianxiang LIU
Chinese Journal of Radiological Health 2024;33(1):28-32
Objective To investigate the effects of prolonged low-dose neutron-γ radiation on peripheral blood lymphocytes of logging workers. Methods The health information of workers in a logging company was collected by on-site blood sample collection and questionnaire survey. Individual doses of γ and neutron radiation were recorded using LiF elements and CR-39, respectively. Lymphocyte count in peripheral blood was measured by blood cytometer. Cell cycle and cyclins were detected by flow cytometry. Results The annual dose of some logging workers exceeded 5 mSv. Lymphocyte counts showed a difference of 15% between the group exposed to the lowest annual dose of 0–1 mSv (mean: 2.45 × 109/L) and the group exposed to the highest annual dose of 5–25 mSv (mean: 2.08 × 109/L). In comparison to pre-shift workers, logging workers exhibited a G1-phase arrest in the lymphocyte cycle, along with increased expression of cyclins p21 and CDK2. Conclusion Prolonged exposure to low-dose neutron-γ radiation leads to reduced lymphocyte counts as well as changes in lymphocyte cycle and cyclin expression.


Result Analysis