1.Effects of exercise load on cardiac function in different bodily positions evaluated with three-dimensional speckle tracking technology
Chongfa ZHONG ; Feng ZANG ; Xiaowen ZUO ; Yue WANG ; Yuqing GAI ; Zemin HUANG ; Bin WU ; Guangdan YU ; Chong XU
Chinese Journal of Aerospace Medicine 2025;36(1):12-17
Objective:To investigate the effects of 10° head up tilt bed rest (HUT) on human cardiac function via 3D speckle tracking echocardiography (3D-STE), and to study the difference in cardiac function under the submaximal exercise load between the horizontal position and 10° HUBR.Methods:Thirty young healthy volunteers were recruited as the subjects, who were randomly divided into an 10° HUT exercise group and horizontal exercise group with 15 subjects in each. Subjects in both groups were asked to ride the bicycle ergometer in the 10° HUBR position and supine position respectively. The load started with 50 W and was increased by 25 W every 3 min until it reached the maximum of 125 W. Before the exercise (resting state), 1 min after the load was increased each time, and 3 min after exercise (recovery period), the following indices were collected: ①basic cardiac function indices: heart rate (HR), systolic blood pressure (SBP) and diastolic blood pressure (DBP), ②conventional cardiac ultrasound indices: left ventricular ejection fraction (LVEF), stroke volume (SV) and cardiac output (CO), ③left ventricular strain indices: global longitudinal strain (GLS), global circumferential strain (GCS), and global area strain (GAS) measured by 3D-SET. The changes of these indices in the 2 groups of subjects under different exercise loads were observed.Results:The differences in the major effect of the basic heart indices (HR, SBP and DBP), conventional cardiac ultrasound indices (LVEF, SV and CO) and left ventricular strain indices (GLS, GCS and GAS) in response to the exercise load were statistically significant ( F=194.90, 113.66, 17.19, P=0.017, 0.018, 0.001). With the increase of the exercise load, the basic heart indices and conventional cardiac ultrasound indices kept rising, the left ventricular strain indices reached the minimum under a moderate exercise load (75 W), HR, SBP and CO were higher than those of the resting state ( P<0.05 or 0.01). Both LVEF under exercise loads of 75, 100, 125 W and during recovery, and SV under exercise loads of 100, 125 W and during recovery were significantly higher than those of the resting state ( P<0.05 or 0.01), while GLS and GCS under exercise loads of 50, 75, 125 W ( P<0.05 or 0.01), and GAS under exercise loads of 50, 75 W ( P<0.01) were significantly lower. There were statistically significant differences not only in GCS across the groups ( F=4.60, P=0.026) but also in DBP due to the interactions between the grouping and exercise loads ( F=3.13, P=0.031). DBP was higher than that of the resting state when the exercise load was 125 W in both groups. Conclusions:During submaximal exercise, myocardial contractility shows sustained enhancement with the increase of the exercise load. The results of GLS, GCS and GAS indicate that myocardial strain reaches its lowest value under a moderate exercise load, suggesting that moderate exercise can be used to evaluate cardiac function via 3D-SET. Under a simulated lunar gravity of 10° HUT, there is less deformation in the short axis direction of the myocardium, indicating that GCS can be used as a sensitive indicator to detect changes in cardiac function under different gravities.
2.Efficacy and safety of standard pulsed radiofrequency for treating rare-site glomus tumors
Dong WANG ; Yujia LUO ; Yunze LI ; Qi GAI ; Zhiying FENG
Chongqing Medicine 2025;54(1):76-79,85
Objective To explore the efficacy and safety of standard pulsed radiofrequency for treating rare-site glomus tumors.Methods A prospective self before-and-after control study was conducted and 6 pa-tients diagnosed as glomus tumors in the pain department of Yongkang Municipal First People's Hospital from June 2022 to January 2023 served as the study subjects.Among them,1 case was located in the outer beam of deltoid muscle in the upper arm,and 5 cases were located under the nail beds of the hands/feet.All subjects underwent the standard pulsed radiofrequency treatment under ultrasound guidance and were fol-lowed up for at least 12 months.The changes in the preoperative and postoperative Numerical Rating Scale(NRS)scores were observed,and the changes in the"typical triad",healing degree of the nail growth matrix and recurrence of pain were recorded.Results The postoperative follow-up results showed that all patients had significant decreases in NRS scores,indicating that the pain degree obtained the effective control.Among them,4 patients did not experience the pain recurrence after adopting the standard pulsed radiofrequency;1 pa-tient had pain recurrence in postoperative 6 months and the tumor body was ultimately removed by surgery.Apart from the patient 2 developing transient subungual congestion,no significant adverse events were observed.Conclusion The standard pulsed radiofrequency treatment is a safe and effective therapeutic method for pain caused by rare-site glomus tumors.
3.Label-free Fluorescence Probe Based on Primer Exchange Reaction for High Sensitivity Detection of Apurinic/Apyrimidinic Endonuclease 1
Yun-Hua WANG ; Le-Ru WANG ; Li-Gai YANG ; Jia-Zheng CHEN ; Yu-Run DU ; Jia-Hui HOU ; Xiang ZHAI ; Xu-Hua ZHAO ; Bao-Feng YU
Chinese Journal of Analytical Chemistry 2025;53(3):464-471
Apurinic/apyrimidinic endonuclease 1(APE 1)is a multifunctional protein that plays important roles in DNA repair and regulation of gene expression.Because APE 1 is overexpressed in various cancers,it can serve as a cancer biomarker for aiding clinical diagnosis,guiding therapy,and monitoring prognosis.On this basis,a label-free fluorescent probe was designed based on the primer exchange reaction(PER)strategy for highly sensitive detection of APE 1 activity.In the absence of APE 1,the structure of catalytic hairpin(HP)was stable and could not form G-quadruplex.Therefore,the background fluorescence of this sensing system was very low due to the dissociation of thioflavin T(ThT).In the presence of APE 1,the apurinic/apyrimidinic(AP)site of HP was cleaved by APE 1 and a short nucleic acid fragment that acted as a primer to initiate PER was generated.After PER reaction,a large number of G-quadruplex were produced,which could specifically bind with ThT and resulted in significant increase of fluorescence signal.The combination of low background design of HP and PER amplification made this biosensor had high sensitivity with a detection limit(3σ)of 0.0008 U/mL.Furthermore,the primer sequence was directly generated by the cleavage of APE 1 without additional addition,which not only increased the specificity of the reaction,but also simplified the experiment procedure.Moreover,the use of label-free fluorescence signal reduced the cost of the experiment,and realized rapid detection of APE 1.Finally,this sensor was used to detect APE 1 in human serum samples with spiked recoveries of 91%-104%,proving great potential in study of biological enzyme.
4.Application of 3D printing technology in bone graft fusion surgery for cervical spondylotic myelopathy
Lei TANG ; Qi WANG ; Zhi-yong CHAI ; Jun WANG ; Jing-ying GAI ; Yi-feng LIU
Journal of Regional Anatomy and Operative Surgery 2025;34(8):702-706
Objective To explore the clinical effect of 3D-printed interbody fusion cage applied in anterior cervical decompression and bone graft fusion for the treatment of cervical spondylotic myelopathy.Methods A total of 100 patients with cervical spondylotic myelopathy who underwent anterior cervical fusion surgery in our hospital from June 2020 to June 2023 were selected as the research subjects,they were randomly divided into the 3D group and the control group according to the random number table method,with 50 cases in each group.Patients in the 3D group were implanted with a 3D-printed interbody fusion cage which was made of microporous metal materials,while patients in the control group were implanted with intervertebral fusion cage which was made of polyetheretherketone material.The surgery-related indicators,cervical imaging parameters,cervical spinal cord function,cervical axial function and surgical complications of patients between the two groups were compared.Results There was no statistically significant difference in the operation time,intraoperative blood loss or length of hospital stay of patients between the two groups(P>0.05).The height of the cervical fusion segments and the Cobb angle of the fusion segments of patients in both groups at each time point after the operation were significantly increased compared with those before the operation(P<0.05).The height of the cervical fusion segments and the Cobb angle of the fusion segments of patients 1 month,3 months,and 6 months after the operation in the 3D group were all greater than those in the control group(P>0.05).The subjective symptom score and the total score of the Japanese orthopaedic association(JOA)of patients 6 months after the operation in the 3D group were higher than those in the control group(P<0.05).The cervical axial function of patients 6 months after the operation in the 3D group was better than that in the control group(P<0.05).The incidence of surgical complications in the 3D group was lower than that in the control group(P<0.05).Conclusion The use of 3D-printed interbody fusion cage during the anterior cervical decompression and bone graft fusion for patients with cervical spondylotic myelopathy can significantly improve the clinical symptoms of patients,achieve better cervical axial function,and have fewer complications.
5.Application of 3D printing technology in bone graft fusion surgery for cervical spondylotic myelopathy
Lei TANG ; Qi WANG ; Zhi-yong CHAI ; Jun WANG ; Jing-ying GAI ; Yi-feng LIU
Journal of Regional Anatomy and Operative Surgery 2025;34(8):702-706
Objective To explore the clinical effect of 3D-printed interbody fusion cage applied in anterior cervical decompression and bone graft fusion for the treatment of cervical spondylotic myelopathy.Methods A total of 100 patients with cervical spondylotic myelopathy who underwent anterior cervical fusion surgery in our hospital from June 2020 to June 2023 were selected as the research subjects,they were randomly divided into the 3D group and the control group according to the random number table method,with 50 cases in each group.Patients in the 3D group were implanted with a 3D-printed interbody fusion cage which was made of microporous metal materials,while patients in the control group were implanted with intervertebral fusion cage which was made of polyetheretherketone material.The surgery-related indicators,cervical imaging parameters,cervical spinal cord function,cervical axial function and surgical complications of patients between the two groups were compared.Results There was no statistically significant difference in the operation time,intraoperative blood loss or length of hospital stay of patients between the two groups(P>0.05).The height of the cervical fusion segments and the Cobb angle of the fusion segments of patients in both groups at each time point after the operation were significantly increased compared with those before the operation(P<0.05).The height of the cervical fusion segments and the Cobb angle of the fusion segments of patients 1 month,3 months,and 6 months after the operation in the 3D group were all greater than those in the control group(P>0.05).The subjective symptom score and the total score of the Japanese orthopaedic association(JOA)of patients 6 months after the operation in the 3D group were higher than those in the control group(P<0.05).The cervical axial function of patients 6 months after the operation in the 3D group was better than that in the control group(P<0.05).The incidence of surgical complications in the 3D group was lower than that in the control group(P<0.05).Conclusion The use of 3D-printed interbody fusion cage during the anterior cervical decompression and bone graft fusion for patients with cervical spondylotic myelopathy can significantly improve the clinical symptoms of patients,achieve better cervical axial function,and have fewer complications.
6.Effects of exercise load on cardiac function in different bodily positions evaluated with three-dimensional speckle tracking technology
Chongfa ZHONG ; Feng ZANG ; Xiaowen ZUO ; Yue WANG ; Yuqing GAI ; Zemin HUANG ; Bin WU ; Guangdan YU ; Chong XU
Chinese Journal of Aerospace Medicine 2025;36(1):12-17
Objective:To investigate the effects of 10° head up tilt bed rest (HUT) on human cardiac function via 3D speckle tracking echocardiography (3D-STE), and to study the difference in cardiac function under the submaximal exercise load between the horizontal position and 10° HUBR.Methods:Thirty young healthy volunteers were recruited as the subjects, who were randomly divided into an 10° HUT exercise group and horizontal exercise group with 15 subjects in each. Subjects in both groups were asked to ride the bicycle ergometer in the 10° HUBR position and supine position respectively. The load started with 50 W and was increased by 25 W every 3 min until it reached the maximum of 125 W. Before the exercise (resting state), 1 min after the load was increased each time, and 3 min after exercise (recovery period), the following indices were collected: ①basic cardiac function indices: heart rate (HR), systolic blood pressure (SBP) and diastolic blood pressure (DBP), ②conventional cardiac ultrasound indices: left ventricular ejection fraction (LVEF), stroke volume (SV) and cardiac output (CO), ③left ventricular strain indices: global longitudinal strain (GLS), global circumferential strain (GCS), and global area strain (GAS) measured by 3D-SET. The changes of these indices in the 2 groups of subjects under different exercise loads were observed.Results:The differences in the major effect of the basic heart indices (HR, SBP and DBP), conventional cardiac ultrasound indices (LVEF, SV and CO) and left ventricular strain indices (GLS, GCS and GAS) in response to the exercise load were statistically significant ( F=194.90, 113.66, 17.19, P=0.017, 0.018, 0.001). With the increase of the exercise load, the basic heart indices and conventional cardiac ultrasound indices kept rising, the left ventricular strain indices reached the minimum under a moderate exercise load (75 W), HR, SBP and CO were higher than those of the resting state ( P<0.05 or 0.01). Both LVEF under exercise loads of 75, 100, 125 W and during recovery, and SV under exercise loads of 100, 125 W and during recovery were significantly higher than those of the resting state ( P<0.05 or 0.01), while GLS and GCS under exercise loads of 50, 75, 125 W ( P<0.05 or 0.01), and GAS under exercise loads of 50, 75 W ( P<0.01) were significantly lower. There were statistically significant differences not only in GCS across the groups ( F=4.60, P=0.026) but also in DBP due to the interactions between the grouping and exercise loads ( F=3.13, P=0.031). DBP was higher than that of the resting state when the exercise load was 125 W in both groups. Conclusions:During submaximal exercise, myocardial contractility shows sustained enhancement with the increase of the exercise load. The results of GLS, GCS and GAS indicate that myocardial strain reaches its lowest value under a moderate exercise load, suggesting that moderate exercise can be used to evaluate cardiac function via 3D-SET. Under a simulated lunar gravity of 10° HUT, there is less deformation in the short axis direction of the myocardium, indicating that GCS can be used as a sensitive indicator to detect changes in cardiac function under different gravities.
7.Atrial septal puncture in swine guided by X-ray fluoroscopy
Gai-Gai MA ; Feng-Xu FAN ; Jun CHEN ; Bao-Kun WANG ; Ming-Yang QIAO ; Kang-An CHENG
Chinese Journal of Interventional Cardiology 2024;32(5):257-260
Objective To explore the standardized process and method of atrial septum puncture(ASP)in swine guided by X-ray fluoroscopy and make ASP more safe and effective.Methods ASP was performed in 48 Pudong swines guided by X-ray fluoroscopy.Three protocols for precise location of atrial septal puncture points were recommended.(1)Site of atrial septal puncture point in cranial-caudal direction was determined under posterior-anterior projection,which was confined to the cranial side of the coronary sinus(CS)orifice at a distance of 1 cone body height along the midline of spine.(2)With 10° intervals,the fluoroscopy of the CS catheter was completed according to the right anterior oblique 10°~60° and the left anterior oblique 10°~60°,and the connection line of the CS 5-6 and 7-8 electrodes was perpendicular to the oval fossa,so as to confirm the perspective angle of the CS 5-6 and 7-8 electrodes in the same straight line.(3)The arch feature of puncture needle and distal part of sheath turned into a straight line under the perspective angle,of which the CS 5-6 and 7-8 electrodes were in the same straight line.Results ASP was successfully performed in 48 Pudong swines without any complications.Echocardiography showed left to right shunt through atrial septum after ASP.The average time of ASP was(25.7±11.5)minutes,the average X-ray exposure time is(14.0±3.4)min and the average radiation dose was(47.6±20.2)Gmy.Conclusions Using the coronal sinus electrode as a reference,atrial septal puncture in swine guided by X-ray fluoroscopy was safe and reliable.
8.Application of iliac vein molding and stent implantation through the ipsilateral great saphenous vein approach in daytime treatment mode
Qichen FENG ; Shuo GAI ; Changming WANG ; Xuan LI
Journal of Peking University(Health Sciences) 2024;56(2):322-325
Objective:To explore the feasibility and recent efficacy of iliac vein molding and stenting in daytime treatment mode in patients with iliac vein stenosis.Methods:Medical records of iliac vein molding and stenting performed in the ipsilateral great saphenous vein approach conducted from February 2017 to March 2022 were retrospective reviewed.There were 21 cases,6 males and 15 females.Age ranged from 37 to 79 years[(62.5±10.2)years].The stenosis in the 21 limbs simply involved the common iliac veins in 16 patients,2 patients had the simple and external iliac veins,and both the total and external iliac veins in 3 patients.Both iliac vein molding and iliac vein stenting were performed through the ipsilateral great saphenous vein approach.The patients with simple iliac vein stenosis with great saphenous vein valve insufficiency also underwent radiofrequency closure of great saphenous vein and flexural vein sclerosis therapy simultaneously.Regular postoperative direct oral anticoagulants therapy and stress therapy were followed.All the patients were hospitalized for less than 24 h.Results:All the 21 patients operations were successful(the success rate was 100%),without any intraoperative compli-cations.Immediate postoperative complications were puncture point bleeding in 1 case.The bandage gauze was completely wet.The bleeding was stopped after 5min of recompression.All the patients were hospitalized for less than 24 h.Follow-up results:The 3-month follow-up rate after operation was 100%.Absolute effective 18 cases(18/21,85.7%).Relatively effective(postmentation still after surgery,but with less extent)in 3 cases(3/21,14.3%).The iliac vein stents were unobstructed,and the trunk of the great saphenous vein was well closed in the patients with great saphenous vein radiofrequency treat-ment.The 6-month follow-up rate after operation was 71.4%(15/21).Of these,14 cases(14/15,93.3%)were absolutely effective.Relatively effective(postmentation still after surgery,but with less ex-tent)in 1 case(1/15,6.7%).The iliac vein stents were no restenosis or obstruction,and the trunk of the great saphenous vein was well closed in the patients with great saphenous vein radiofrequency treat-ment.Conclusion:The interventional treatment technique of iliac vein stenosis is feasible in the daytime treatment mode,with clear advantages and satisfactory recent efficacy.
9.Clinical trial of midazolam and propofol in the treatment of elderly patients undergoing mechanical ventilation after cardiopulmonary bypass cardiac surgery
En-Gang WU ; Sheng-Jun DONG ; Ning GAI ; Bao-Hui LIU ; Dian-Xiao LIU ; Feng WANG ; Kai-Qiang YANG ; Qian-Qian WANG
The Chinese Journal of Clinical Pharmacology 2024;40(7):963-967
Objective To analyze the influence of midazolam and propofol on sedation effect and blood gas indicators in elderly patients undergoing mechanical ventilation after cardiopulmonary bypass(CPB)cardiac surgery.Methods The elderly patients with mechanical ventilation after CPB cardiac surgery were grouped according to cohort method,including midazolam group(group M),propofol group(group P)and midazolam-propofol combined administration group(group M-P).Group M was treated with midazolam(intravenous injection of 0.05-0.10 mg kg-1 midazolam for sedation induction,and then continuously intravenous injection of 0.05-0.15 mg·kg-1·h-1 midazolam by micropump),and group P was treated with propofol(intravenous injection of 0.5 mg·kg-1 propofol for sedation induction,and then continuously intravenous injection of 0.5-2.0 mg·kg-1·h-1 propofol by micropump),and group M-P was given combined administration of midazolam and propofol(intravenous injection of 0.02-0.05 mg·kg-1 midazolam and 0.2-0.5 mg·kg-1 propofol for sedation induction and then continuously intravenous pump of 0.05-0.1 mg·kg-1 midazolam and 0.5-0.8 mg·kg·h-1 propofol).The sedation effect,blood gas indicators,hemodynamic indicators,extubation time,intensive care unit(ICU)stay time and treatment cost were compared among the three groups,and the adverse drug reactions during sedation therapy were recorded.Results There were 43 cases in group M,44 cases in group P,39 cases in group M-P.The drug onset times in groups M,P and M-P were(77.94±12.05),(18.18±5.20)and(21.25±9.36)s;the times to achieve satisfactory sedation effect were(42.57±11.41),(22.63±8.17)and(23.98±10.25)min;the recovery times after withdrawal were(59.30±14.86),(19.83±5.44)and(22.16±6.29)min;the extubation times were(1.61±0.20),(1.45±0.22)and(1.37±0.15)d;the ICU stay times were(2.17±0.29),(1.91±0.36)and(1.84±0.25)d;the treatment costs were(186.59±60.83),(922.97±164.34)and(375.03±71.16)thousand yuan;and the total incidence rates of adverse drug reactions were 34.88%,4.55%and 7.69%respectively,all with significant difference(all P<0.05).There were no statistically significant differences in mean arterial pressure(MAP),heart rate(HR),oxygen saturation(SpO2),partial pressure of oxygen(PaO2),partial pressure of carbon dioxide(PaCO2)at T0,T1,T2,T3 and T4 among the three groups(all P>0.05).Conclusion Combined administration of midazolam and propofol in elderly patients underwent mechanical ventilation after CPB cardiac surgery has a significant sedation effect,and it is conducive to reducing the dosages of sedative drugs,and it has small impact on blood gas indicators and hemodynamic indicators of patients.Compared with midazolam alone,it is more beneficial to shortening the extubation time and ICU stay and reducing the total incidence rate of adverse drug reactions,and compared with propofol alone,it is more beneficial to reducing treatment cost,and is a more ideal sedation administration model.
10.Distribution of non-bacterial pathogens in 1 788 children with community-acquired pneumonia.
Shuang WANG ; Xue-Feng WANG ; Na LI ; Yue-Xin ZHANG ; Jing CHEN ; Gai-Mei WANG
Chinese Journal of Contemporary Pediatrics 2023;25(6):633-638
OBJECTIVES:
To investigate the distribution characteristics of non-bacterial pathogens in community-acquired pneumonia (CAP) in children.
METHODS:
A total of 1 788 CAP children admitted to Shenyang Children's Hospital from December 2021 to November 2022 were selected. Multiple RT-PCR and capillary electrophoresis were used to detect 10 viral pathogens and 2 atypical pathogens, and serum antibodies of Chlamydial pneumoniae (Ch) and Mycoplasma pneumoniae (MP) were detected. The distribution characteristics of different pathogens were analyzed.
RESULTS:
Among the 1 788 CAP children, 1 295 children were pathogen-positive, with a positive rate of 72.43% (1 295/1 788), including a viral pathogen positive rate of 59.68% (1 067/1 788) and an atypical pathogen positive rate of 22.04% (394/1 788). The positive rates from high to low were MP, respiratory syncytial virus (RSV), influenza B virus (IVB), human metapneumovirus (HMPV), human rhinovirus (HRV), human parainfluenza virus (HPIV), influenza A virus (IVA), bocavirus (BoV), human adenovirus (HADV), Ch, and human coronavirus (HCOV). RSV and MP were the main pathogens in spring; MP had the highest positive rate in summer, followed by IVA; HMPV had the highest positive rate in autumn; IVB and RSV were the main pathogens in winter. The positive rate of MP in girls was higher than that in boys (P<0.05), and there were no significant differences in other pathogens between genders (P>0.05). The positivity rates of certain pathogens differed among age groups (P<0.05): the positivity rate of MP was highest in the >6 year-old group; the positivity rates of RSV and Ch were highest in the <1 year-old group; the positivity rates of HPIV and IVB were highest in the 1 to <3 year-old group. RSV, MP, HRV, and HMPV were the main pathogens in children with severe pneumonia, while MP was the primary pathogen in children with lobar pneumonia, and MP, IVB, HMPV, RSV, and HRV were the top 5 pathogens in acute bronchopneumonia.
CONCLUSIONS
MP, RSV, IVB, HMPV, and HRV are the main pathogens of CAP in children, and there are certain differences in the positive rates of respiratory pathogens among children of different ages, genders, and seasons.
Humans
;
Child
;
Female
;
Male
;
Infant
;
Child, Preschool
;
Pneumonia
;
Respiratory Syncytial Virus, Human
;
Antibodies
;
Community-Acquired Infections
;
Hospitalization
;
Influenza B virus
;
Mycoplasma pneumoniae

Result Analysis
Print
Save
E-mail