1.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
2.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
3.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
4.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
5.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
6.Epilepsy prediction model based on 2D-CNN and Cox-Stuart early stopping mechanism
Xizhen ZHANG ; Xiaoli ZHANG ; Yang LÜ ; Fuming CHEN
Chinese Journal of Medical Physics 2025;42(1):82-94
An epilepsy prediction model based on two-dimensional convolutional neural network and Cox-Stuart test for non-independent patients is proposed to address the problem of how to effectively predict whether epilepsy patients are going to have an attack or not. After EEG data normalization and EEG signal noise removal using a notch filter and a high-pass filter,the filtered signals are inputted into the two-dimensional convolutional neural network model for feature extraction and classification,and Cox-Stuart test is used to determine whether an early stopping is needed or not,thereby reducing the computational and time complexities of the model. The model is tested under the conditions with pre-seizure periods of 10,30 and 60 min,respectively,and the results show that the model performs best when the pre-seizure period is 10 min. The model has an average accuracy,sensitivity and specificity of 97.70%,97.36%and 98.04%on the test set,demonstrating its superior performance.
7.Epilepsy prediction model based on 2D-CNN and Cox-Stuart early stopping mechanism
Xizhen ZHANG ; Xiaoli ZHANG ; Yang LÜ ; Fuming CHEN
Chinese Journal of Medical Physics 2025;42(1):82-94
An epilepsy prediction model based on two-dimensional convolutional neural network and Cox-Stuart test for non-independent patients is proposed to address the problem of how to effectively predict whether epilepsy patients are going to have an attack or not. After EEG data normalization and EEG signal noise removal using a notch filter and a high-pass filter,the filtered signals are inputted into the two-dimensional convolutional neural network model for feature extraction and classification,and Cox-Stuart test is used to determine whether an early stopping is needed or not,thereby reducing the computational and time complexities of the model. The model is tested under the conditions with pre-seizure periods of 10,30 and 60 min,respectively,and the results show that the model performs best when the pre-seizure period is 10 min. The model has an average accuracy,sensitivity and specificity of 97.70%,97.36%and 98.04%on the test set,demonstrating its superior performance.
8.Research progress in nanoparticle-mediated cryoablation therapy for tumors
Journal of Interventional Radiology 2024;33(2):197-201
Cryoablation is a local ablation treatment based on the hypothermia effect,which has been widely used in the treatment of various solid tumors throughout the body.However,low freezing efficiency and insufficient accuracy are the problems in clinical cryoablation therapy which need to be solved urgently.With the continuous progress of nanoscience,various types of nanoparticles have been developed and applied in clinical practice.After being loaded into the target area,the nanoparticles can exert functions such as targeted drug delivery as well as image enhancement,which provides the possibility to break through the current clinical application bottleneck of cryoablation therapy.This paper aims to make a comprehensive review about several currently commonly-used nanoparticles for cryoablation therapy,focusing on their main functions and mechanisms,with the hope that the physicians concerned can get a further detailed understanding of the nanoparticles and lay a solid foundation for conducting in-depth researches and achieving clinical transformation.
9.Characteristics of malaria cases in Lishui City from 2012 to 2023
YE Xialiang ; CHEN Xiuying ; RUAN Wei ; YU Yang ; PAN Xiaomeng ; LU Yuzhong ; LIU Wujing ; LIU Fuming ; TAO Tao
Journal of Preventive Medicine 2024;36(9):809-812
Objective:
To investigate the characteristics and trends of malaria cases in Lishui City, Zhejiang Province from 2012 to 2023, so as to provide a basis for improving malaria prevention and control measures.
Methods:
Case data of malaria in Lishui City from 2012 to 2023 were collected from the Parasitic Disease Control Information Management System of the National Information System for Disease Control and Prevention in China. The parasite species, source of infection, temporal distribution, population distribution, geographical distribution, and clinical diagnosis and treatment of the cases were descriptively analyzed.
Results:
A total of 169 malaria cases were reported in Lishui City from 2012 to 2023, and P. falciparum malaria was the main type, accounting for 79.88% (135 cases). The positive rate of Plasmodium detection was 3.30‰(169/51 212), the highest was 5.41‰ (18/3 327) in 2017, and the lowest was 0.38‰ (1/2 632) in 2021. Malaria cases were reported in every month from 2012 to 2023, with 91 cases (53.85%) reported from May to October. There were 168 imported cases, of which 163 (96.45%) originated from Africa. There were 127 male cases (75.15%), and the majority of cases were aged 20 to 49 years, with 138 cases accounting for 81.65%. The majority of the occupation was overseas labor export workers, with 164 cases accounting for 97.04%. A total of 161 cases (95.27%) were registered residents of Lishui City, and cases were reported from all nine counties (cities, districts), with Qingtian County and Liandu District having the higher numbers of 98 and 41 cases, respectively. The median interval from onset to hospital visit for malaria cases was 2.00 (interquartile range, 4.00) days, and the median interval from hospital visit to diagnosis was 0 (interquartile range, 1.00) day. The diagnostic rate of first-diagnosed malaria cases in municipal and county medical institutions was 95.90% (117/122) and 91.49% (43/47), respectively, with no statistical significance (P>0.05).
Conclusions
The P. falciparum malaria was the predominant type in Lishui City from 2012 to 2023, with the majority of cases being imported. Male overseas labor export personnel aged 20 to <50 were the key demographic.
10.Progress of research on the design of implant-abutment interface
Jimin JIANG ; Yinlin WANG ; Hang YANG ; Fuming HE
STOMATOLOGY 2024;44(9):692-698
The stability of marginal bone level is an important factor in ensuring long-term good clinical efficacy of implantation.The design of implant-abutment interface(IAI)is of considerable importance,including whether undergoing multiple abutment disconnection,whether platform switching is used,connection type,connection torque,and connection material differences.These fac-tors can affect the micro gap and micro movement of the connection interface,which change the size of micro leakage and mechanical stability,thereby affecting the long-term clinical efficacy of implants.This article presents a detailed review of the progress of research on different designs in implant-abutment interface,in order to provide a theoretical basis for the selection and operation of abutments in clinical diagnosis and treatment.


Result Analysis
Print
Save
E-mail