1.Expert Consensus on Neurocritical Care Monitoring and Management in Beijing and Tibet(2025)
Drolma PHURBU ; Wenjin CHEN ; Heng ZHANG ; Jian ZHANG ; Xiaomeng WANG ; Guoying LIN ; Wenjun PAN ; Xiying GUI ; Xin CAI ; Chodron TENZIN ; Jianlei FU ; Qianwei LI ; TSEYANG ; Yijun LIU ; Bo LIU ; Tsering DROLMA ; Yudron SONAM ; KYILV ; Samdrup TSERING ; Wa DA ; Juan GUO ; Cheng QIU ; Huan CHEN ; Xiaoting WANG ; Yangong CHAO ; Dawei LIU ; Wenzhao CHAI ; Chenggong HU ; Wanhong YIN ; Shihong ZHU
Medical Journal of Peking Union Medical College Hospital 2026;17(1):59-72
Neurocritical care involves complex pathophysiological mechanisms, and its incidence is higher, injuries are more severe, and treatment is more challenging in high-altitude environments. This consensus, based on the latest domestic and international evidence-based medical data, establishes a standardized, goal-oriented framework for neurocritical care management applicable in high-altitude regions and nationwide. The consensus was developed following international standards for evidence quality assessment and underwent two rounds of Delphi expert consultation, resulting in 32 recommendation statements covering three parts: management systems, monitoring and assessment, and core strategies. Key updates include: advocating for the establishment of independent neurocritical care units and implementing precise tiered diagnosis and treatment based on the "Five Differences in Critical Care" concept; constructing a "trinity" multimodal brain monitoring system centered on cerebral blood flow, cerebral oxygenation, and brain function, emphasizing routine bedside transcranial Doppler ultrasound, cerebral oximetry, and continuous electroencephalography monitoring; shifting management strategies from mild hypothermia therapy to targeted temperature management, and defining the "446" target management pathway for the supercritical stage; emphasizing the assessment of static and dynamic cerebrovascular autoregulation functions through multimodal methods to achieve individualized optimal mean arterial pressure management; elevating cerebrospinal fluid management goals to the level of "glymphatic system" function maintenance; implementing a multidisciplinary collaborative, whole-process management model focusing on patients' long-term neurological functional outcomes; de-escalation criteria include multidimensional indicators such as recovery of brain structure, restoration of cerebrovascular autoregulation, improvement in cerebrospinal fluid dynamics, and reduction in biomarker levels; and integrating cutting-edge technologies like artificial intelligence into post-critical care management and rehabilitation planning. This consensus systematically integrates the entire process of neurocritical care management, reflecting the modern connotation of goal-oriented, dynamic, and multimodal integration in neurocritical care medicine. It aims to adapt to new trends such as deepening understanding of pathophysiological mechanisms, the integration of medicine and engineering, and the empowerment of artificial intelligence, thereby further advancing the discipline of critical care medicine.
2.Cage design-centric glider approach to full-endoscopic lumbar fusion: optimizing nerve root protection in facet-sparing and facet-resecting techniques
Yu-Chia HSU ; Hao-Chun CHUANG ; Yuan-Fu LIU ; Chao-Jui CHANG ; Yu-Meng HSIAO ; Yi-Hung HUANG ; Keng-Chang LIU ; Chien-Min CHEN ; Hyeun-Sung KIM ; Cheng-Li LIN
Asian Spine Journal 2026;20(2):343-353
Endoscopic transforaminal lumbar interbody fusion (TLIF) offers substantial advantages in the management of degenerative spinal diseases, including accelerated postoperative recovery. However, its technical complexity and steep learning curve pose risks for nerve root injury. Optimizing nerve root protection in full-endoscopic facet-sparing TLIF (FE fs-TLIF) and full-endoscopic facet-resecting TLIF (FE fr-TLIF) is essential for enhancing surgical safety. This study aimed to improve the nerve root protection in FE fs-TLIF and FE fr-TLIF by optimizing cage glider selection and insertion techniques based on the specific cage shape—banana-shaped or bullet-shaped. The goal was to ensure safe cage positioning and mitigate nerve root injury during discectomy, endplate preparation, and cage insertion. These strategies were validated through cadaveric simulations and clinical implementation. In FE fr-TLIF utilizing bullet-shaped (straight) cages, one-tip and two-tip cage gliders effectively protected the traversing nerve root by facilitating medial cage entry, thereby minimizing irritation of the exiting nerve root. Conversely, in FE fr-TLIF with banana-shaped cages, the lateral tilt of the cage holder during implantation required the use of a two-tip cage glider to protect the traversing and exiting nerve roots, thereby mitigating the potential risk of nerve irritation. In FE fs-TLIF, a one-tip cage glider is preferred for safeguarding the exiting nerve root, while the traversing root is inherently protected by the medial wall of the facet joint. The use of a two-tip cage glider in FE fs-TLIF can cause injury to the nerve root during glider insertion. In addition to the selection of cage gliders, improper cage insertion steps can also contribute to postoperative neurapraxia. The appropriate selection of cage gliders with corresponding insertion techniques is critical for nerve root protection in endoscopic TLIF. Tailoring these choices to the specific approach (FE fs-TLIF or FE fr-TLIF) and cage type (banana or bullet) enhances surgical safety and clinical outcomes.
3.Predictive Modeling of Symptomatic Intracranial Hemorrhage Following Endovascular Thrombectomy: Insights From the Nationwide TREAT-AIS Registry
Jia-Hung CHEN ; I-Chang SU ; Yueh-Hsun LU ; Yi-Chen HSIEH ; Chih-Hao CHEN ; Chun-Jen LIN ; Yu-Wei CHEN ; Kuan-Hung LIN ; Pi-Shan SUNG ; Chih-Wei TANG ; Hai-Jui CHU ; Chuan-Hsiu FU ; Chao-Liang CHOU ; Cheng-Yu WEI ; Shang-Yih YAN ; Po-Lin CHEN ; Hsu-Ling YEH ; Sheng-Feng SUNG ; Hon-Man LIU ; Ching-Huang LIN ; Meng LEE ; Sung-Chun TANG ; I-Hui LEE ; Lung CHAN ; Li-Ming LIEN ; Hung-Yi CHIOU ; Jiunn-Tay LEE ; Jiann-Shing JENG ;
Journal of Stroke 2025;27(1):85-94
Background:
and Purpose Symptomatic intracranial hemorrhage (sICH) following endovascular thrombectomy (EVT) is a severe complication associated with adverse functional outcomes and increased mortality rates. Currently, a reliable predictive model for sICH risk after EVT is lacking.
Methods:
This study used data from patients aged ≥20 years who underwent EVT for anterior circulation stroke from the nationwide Taiwan Registry of Endovascular Thrombectomy for Acute Ischemic Stroke (TREAT-AIS). A predictive model including factors associated with an increased risk of sICH after EVT was developed to differentiate between patients with and without sICH. This model was compared existing predictive models using nationwide registry data to evaluate its relative performance.
Results:
Of the 2,507 identified patients, 158 developed sICH after EVT. Factors such as diastolic blood pressure, Alberta Stroke Program Early CT Score, platelet count, glucose level, collateral score, and successful reperfusion were associated with the risk of sICH after EVT. The TREAT-AIS score demonstrated acceptable predictive accuracy (area under the curve [AUC]=0.694), with higher scores being associated with an increased risk of sICH (odds ratio=2.01 per score increase, 95% confidence interval=1.64–2.45, P<0.001). The discriminatory capacity of the score was similar in patients with symptom onset beyond 6 hours (AUC=0.705). Compared to existing models, the TREAT-AIS score consistently exhibited superior predictive accuracy, although this difference was marginal.
Conclusions
The TREAT-AIS score outperformed existing models, and demonstrated an acceptable discriminatory capacity for distinguishing patients according to sICH risk levels. However, the differences between models were only marginal. Further research incorporating periprocedural and postprocedural factors is required to improve the predictive accuracy.
4.Antimicrobial resistance surveillance in the bacterial strains isolated from pediatric intensive care units in China:results from 2020 to 2022
Jing LIU ; Huiyuan YAN ; Gangfeng YAN ; Guoping LU ; Pan FU ; Chuanqing WANG ; Danqun JIN ; Wenjia TONG ; Chenyu ZHANG ; Jianli CHEN ; Yi LIN ; Jia LEI ; Yibing CHENG ; Qunqun ZHANG ; Kaijie GAO ; Yuanyuan CHEN ; Shufang XIAO ; Juan HE ; Li JIANG ; Huimin XU ; Yuxia LI ; Hanghai DING ; Hehe CHEN ; Yao ZHENG ; Qunying CHEN ; Ying WANG ; Hong REN ; Chenmei ZHANG ; Zhenjie CHEN ; Mingming ZHOU ; Yucai ZHANG ; Yiping ZHOU ; Zhenjiang BAI ; Saihu HUANG ; Lili HUANG ; Weiguo YANG ; Weike MA ; Qing MENG ; Pengwei ZHU ; Yong LI ; Yan XU ; Yi WANG ; Yanqiang DU ; Huijun CAI ; Bizhen ZHU ; Huixuan SHI ; Shaoxian HONG ; Yukun HUANG ; Meilian HUANG
Chinese Journal of Infection and Chemotherapy 2025;25(3):303-311
Objective This study aimed to investigate the antimicrobial resistance profiles of bacterial strains isolated from pediatric intensive care units(PICU)in China for better antimicrobial therapy.Methods Clinical isolates were collected from 17 institutions,including tertiary care children's hospitals and pediatric department of tertiary general hospitals in China from January 1,2020 to December 31,2022.Antimicrobial susceptibility testing was carried out according to a unified protocol using Kirby-Bauer method or automated systems.Results were interpreted according to the breakpoints released by the Clinical and Laboratory Standards Institute(CLSI)in 2020.Results A total of 10 688 isolates were collected,including gram-positive organisms(39.2%)and gram-negative organisms(60.8%).The top three organisms were S.aureus(13.6%,1 453/10 688),A.baumannii(10.0%,1 067/10 688),and coagulase-negative Staphylococcus(9.9%,1 058/10 688).Multi-drug resistant organisms(MDROs)were very common in children.The prevalence of methicillin-resistant Staphylococcus aureus(MRSA),carbapenem-resistant Enterobacterales(CRE),carbapenem-resistant E.coli,carbapenem-resistant K.pneumoniae(CRKP),carbapenem-resistant A.baumannii(CRAB),and carbapenem-resistant P.aeruginosa(CRPA)was 41.1%,19.4%,8.8%,30.9%,67.4%,and 28.8%,respectively.Overall,more than 50%of Enterobacteriales isolates were resistant to cephalosporins,while nearly 25%of Enterobacteriales isolates were resistant to carbapenems.MDROs were highly resistant to commonly used antibiotics.More than 80%of CRE and CRAB strains were resistant to all beta-lactam antibiotics.CRE and CRAB showed low resistance rates to tigecycline and polymyxin.CRPA showed lower resistance rates to piperacillin,beta-lactamase inhibitor combinations than the resistance rates to third and fourth generation cephalosporins.All of the Staphylococcus and Enterococcus isolates were susceptible to vancomycin and tigecycline.None of PRSP strains isolated from meningitis and nonmeningitis samples were resistant to rifampicin,vancomycin,or linezolid.The prevalence of β-lactamase-negative ampicillin-resistant(BLNAR)strains was 43.3%in Haemophilus influenzae.Conclusions MDROs were prevalent in PICU.It is necessary to establish an effective multidisciplinary team(MDT)to control the antimicrobial resistance.
5.Development of adjustable spatial resolution cone beam CT for small animals
Yingxu LI ; Xilong XU ; Yanhai ZHANG ; Xinlei FU ; Feng GAO ; Yang CHENG ; Wei LIN ; Yu CHEN ; Chengqiang LI ; Jie LU
Chinese Journal of Radiological Medicine and Protection 2025;45(7):679-684
Objective:To design and develop a cone-beam CT imaging system for small animals with continuously adjustable spatial resolution.Methods:The imaging system used an X-ray source with a focal spot size of 30 μm and a flat panel detector with a pixel size of 100 μm. On this premise, a " stepping-focusing-rotating" image acquisition mode was proposed, in which the " focusing" and " stepping" systems were sequentially embedded in the " rotating" system. In this acquisition mode, the X-ray source and flat panel detector were relatively stationary to form the " focusing" system. When the " stepping" system accurately transported the object to the scanning position, the " focusing" system could achieve adjustable spatial resolution by making linear motion around the object to be scanned according to different experimental requirements. Finally the " rotating" system achieve high-quality imaging.Results:The variable spatial resolution of small animal CBCT ranges from 35.7 μm to 71.4 μm, and the FOV ranges from 39.6 mm to 108.0 mm. The conversion time for the limit spatial resolution is 19.125 s, which allowed accurate 3D reconstruction of normal mice at different resolutions with high reproducibility.Conclusions:A cone-beam CT suitable for small animals has been developed, whose spatial resolution and FOV can be adjusted arbitrarily within a certain range, which can meet the different imaging requirements in rodent experiments.
6.Predictive Modeling of Symptomatic Intracranial Hemorrhage Following Endovascular Thrombectomy: Insights From the Nationwide TREAT-AIS Registry
Jia-Hung CHEN ; I-Chang SU ; Yueh-Hsun LU ; Yi-Chen HSIEH ; Chih-Hao CHEN ; Chun-Jen LIN ; Yu-Wei CHEN ; Kuan-Hung LIN ; Pi-Shan SUNG ; Chih-Wei TANG ; Hai-Jui CHU ; Chuan-Hsiu FU ; Chao-Liang CHOU ; Cheng-Yu WEI ; Shang-Yih YAN ; Po-Lin CHEN ; Hsu-Ling YEH ; Sheng-Feng SUNG ; Hon-Man LIU ; Ching-Huang LIN ; Meng LEE ; Sung-Chun TANG ; I-Hui LEE ; Lung CHAN ; Li-Ming LIEN ; Hung-Yi CHIOU ; Jiunn-Tay LEE ; Jiann-Shing JENG ;
Journal of Stroke 2025;27(1):85-94
Background:
and Purpose Symptomatic intracranial hemorrhage (sICH) following endovascular thrombectomy (EVT) is a severe complication associated with adverse functional outcomes and increased mortality rates. Currently, a reliable predictive model for sICH risk after EVT is lacking.
Methods:
This study used data from patients aged ≥20 years who underwent EVT for anterior circulation stroke from the nationwide Taiwan Registry of Endovascular Thrombectomy for Acute Ischemic Stroke (TREAT-AIS). A predictive model including factors associated with an increased risk of sICH after EVT was developed to differentiate between patients with and without sICH. This model was compared existing predictive models using nationwide registry data to evaluate its relative performance.
Results:
Of the 2,507 identified patients, 158 developed sICH after EVT. Factors such as diastolic blood pressure, Alberta Stroke Program Early CT Score, platelet count, glucose level, collateral score, and successful reperfusion were associated with the risk of sICH after EVT. The TREAT-AIS score demonstrated acceptable predictive accuracy (area under the curve [AUC]=0.694), with higher scores being associated with an increased risk of sICH (odds ratio=2.01 per score increase, 95% confidence interval=1.64–2.45, P<0.001). The discriminatory capacity of the score was similar in patients with symptom onset beyond 6 hours (AUC=0.705). Compared to existing models, the TREAT-AIS score consistently exhibited superior predictive accuracy, although this difference was marginal.
Conclusions
The TREAT-AIS score outperformed existing models, and demonstrated an acceptable discriminatory capacity for distinguishing patients according to sICH risk levels. However, the differences between models were only marginal. Further research incorporating periprocedural and postprocedural factors is required to improve the predictive accuracy.
7.From Golgiphagy to Golgimedicine — a new strategy for disease prevention and treatment targeting the Golgi apparatus
Acta Pharmaceutica Sinica 2025;60(2):280-287
Functional disorders of the Golgi apparatus are harmful to the health of organisms, leading to various diseases. Removing damaged Golgi apparatus is crucial for maintaining cellular homeostasis, therefore, autophagy of Golgi apparatus has gradually attracted attention. This article summarizes Golgi autophagy, briefly describes its structure and functions, Golgi autophagy receptors, and the role of Golgi autophagy in disease treatment. It also proposes the new concept of Golgimedicine, which looks forward to the role of Golgi in disease diagnosis, treatment, prognosis, genetic diseases, and rare diseases. This article aims to explore the scientific connotations of Golgi autophagy, Golgi structure and function from the perspective of Golgimedicine, providing theoretical references for drug target research, new drug development, and the healthy development of humanity.
8.Delayed covering causes the accumulation of motile sperm, leading to overestimation of sperm concentration and motility with a Makler counting chamber.
Lin YU ; Qing-Yuan CHENG ; Ye-Lin JIA ; Yan ZHENG ; Ting-Ting YANG ; Ying-Bi WU ; Fu-Ping LI
Asian Journal of Andrology 2025;27(1):59-64
According to the World Health Organization (WHO) manual, sperm concentration should be measured using an improved Neubauer hemocytometer, while sperm motility should be measured by manual assessment. However, in China, thousands of laboratories do not use the improved Neubauer hemocytometer or method; instead, the Makler counting chamber is one of the most widely used chambers. To study sources of error that could impact the measurement of the apparent concentration and motility of sperm using the Makler counting chamber and to verify its accuracy for clinical application, 67 semen samples from patients attending the Department of Andrology, West China Second University Hospital, Sichuan University (Chengdu, China) between 13 September 2023 and 27 September 2023, were included. Compared with applying the cover glass immediately, delaying the application of the cover glass for 5 s, 10 s, and 30 s resulted in average increases in the sperm concentration of 30.3%, 74.1%, and 107.5%, respectively (all P < 0.0001) and in the progressive motility (PR) of 17.7%, 30.8%, and 39.6%, respectively (all P < 0.0001). However, when the semen specimens were fixed with formaldehyde, a delay in the application of the cover glass for 5 s, 10 s, and 30 s resulted in an average increase in the sperm concentration of 6.7%, 10.8%, and 14.6%, respectively, compared with immediate application of the cover glass. The accumulation of motile sperm due to delays in the application of the cover glass is a significant source of error with the Makler counting chamber and should be avoided.
Humans
;
Male
;
Sperm Motility/physiology*
;
Sperm Count
;
Semen Analysis/methods*
;
Spermatozoa/physiology*
;
Time Factors
9.Synthesis and evaluation of TSPO-targeting radioligand 18FF-TFQC for PET neuroimaging in epileptic rats.
Wenhui FU ; Qingyu LIN ; Zhequan FU ; Tingting YANG ; Dai SHI ; Pengcheng MA ; Hongxing SU ; Yunze WANG ; Guobing LIU ; Jing DING ; Hongcheng SHI ; Dengfeng CHENG
Acta Pharmaceutica Sinica B 2025;15(2):722-736
The translocator protein (TSPO) positron emission tomography (PET) can noninvasively detect neuroinflammation associated with epileptogenesis and epilepsy. This study explored the role of the TSPO-targeting radioligand [18F]F-TFQC, an m-trifluoromethyl ER176 analog, in the PET neuroimaging of epileptic rats. Initially, [18F]F-TFQC was synthesized with a radiochemical yield of 8%-10% (EOS), a radiochemical purity of over 99%, and a specific activity of 38.21 ± 1.73 MBq/nmol (EOS). After determining that [18F]F-TFQC exhibited good biochemical properties, [18F]F-TFQC PET neuroimaging was performed in epileptic rats at multiple time points in various stages of disease progression. PET imaging showed specific [18F]F-TFQC uptake in the right hippocampus (KA-injected site, i.e., epileptogenic zone), which was most pronounced at 1 week (T/NT 1.63 ± 0.21) and 1 month (T/NT 1.66 ± 0.20). The PET results were further validated using autoradiography and pathological analysis. Thus, [18F]F-TFQC can reflect the TSPO levels and localize the epileptogenic zone, thereby offering the potential for monitoring neuroinflammation and guiding anti-inflammatory treatment in patients with epilepsy.
10.Expert consensus on digital restoration of complete dentures.
Yue FENG ; Zhihong FENG ; Jing LI ; Jihua CHEN ; Haiyang YU ; Xinquan JIANG ; Yongsheng ZHOU ; Yumei ZHANG ; Cui HUANG ; Baiping FU ; Yan WANG ; Hui CHENG ; Jianfeng MA ; Qingsong JIANG ; Hongbing LIAO ; Chufan MA ; Weicai LIU ; Guofeng WU ; Sheng YANG ; Zhe WU ; Shizhu BAI ; Ming FANG ; Yan DONG ; Jiang WU ; Lin NIU ; Ling ZHANG ; Fu WANG ; Lina NIU
International Journal of Oral Science 2025;17(1):58-58
Digital technologies have become an integral part of complete denture restoration. With advancement in computer-aided design and computer-aided manufacturing (CAD/CAM), tools such as intraoral scanning, facial scanning, 3D printing, and numerical control machining are reshaping the workflow of complete denture restoration. Unlike conventional methods that rely heavily on clinical experience and manual techniques, digital technologies offer greater precision, predictability, and efficacy. They also streamline the process by reducing the number of patient visits and improving overall comfort. Despite these improvements, the clinical application of digital complete denture restoration still faces challenges that require further standardization. The major issues include appropriate case selection, establishing consistent digital workflows, and evaluating long-term outcomes. To address these challenges and provide clinical guidance for practitioners, this expert consensus outlines the principles, advantages, and limitations of digital complete denture technology. The aim of this review was to offer practical recommendations on indications, clinical procedures and precautions, evaluation metrics, and outcome assessment to support digital restoration of complete denture in clinical practice.
Humans
;
Denture, Complete
;
Computer-Aided Design
;
Denture Design/methods*
;
Consensus
;
Printing, Three-Dimensional

Result Analysis
Print
Save
E-mail