1.Automatic measurement of detection parameters of quality control of MSCT imaging system
Peiyun YE ; Hui XIONG ; Jian CHEN ; Zhifeng HUANG ; Yamei LIN ; Zhijie YANG ; Chujie CHEN ; Miyang YANG ; Chengkun HONG ; Yuhang ZHANG ; Minghui MAO ; Taipeng ZENG ; Liyuan FU
China Medical Equipment 2024;21(12):18-24
Objective:To design an intelligent measurement program of detection parameters of quality control of imaging system of multi-slice spiral computed tomography (MSCT) based on MATLAB software platform,so as to achieve intelligent detection for quality control of MSCT imaging system. Methods:We designed an intelligent measurement program for the detection parameters of quality control of MSCT imaging system (referred to as the intelligent measurement program) bases on the function of graphical user interfaces (GUI) of MATLAB software. A series of algorithms such as image reading,binarization,and circular detection based on the Hough transform were employed to conduct automatic measurement and calculation for CT values (water),noise and uniformity of the parameters of MSCT quality control. The Intraclass Correlation Coefficient (ICC) was adopted to analyze the consistency of the detection results between the manual measurement method and the designed intelligent detection program. Results:The designed intelligent measurement program in this study can automatically assess the detection parameters of quality control of the MSCT imaging system,which included CT values (water),noise and uniformity. There was favorable consistency in the detection results between the manual measurement method and the intelligent measurement program (range of ICC values was from 0.881 to 0.985). Conclusion:The intelligent measurement program of detection parameters of quality control of MSCT imaging system can simplify the process of calculating detection parameters of quality control of MSCT imaging system,and provide a reliable detection tool for quality control of MSCT imaging equipment,which can effectively improve the detection efficiency of quality control.
2.Automatic measurement of detection parameters of quality control of MSCT imaging system
Peiyun YE ; Hui XIONG ; Jian CHEN ; Zhifeng HUANG ; Yamei LIN ; Zhijie YANG ; Chujie CHEN ; Miyang YANG ; Chengkun HONG ; Yuhang ZHANG ; Minghui MAO ; Taipeng ZENG ; Liyuan FU
China Medical Equipment 2024;21(12):18-24
Objective:To design an intelligent measurement program of detection parameters of quality control of imaging system of multi-slice spiral computed tomography (MSCT) based on MATLAB software platform,so as to achieve intelligent detection for quality control of MSCT imaging system. Methods:We designed an intelligent measurement program for the detection parameters of quality control of MSCT imaging system (referred to as the intelligent measurement program) bases on the function of graphical user interfaces (GUI) of MATLAB software. A series of algorithms such as image reading,binarization,and circular detection based on the Hough transform were employed to conduct automatic measurement and calculation for CT values (water),noise and uniformity of the parameters of MSCT quality control. The Intraclass Correlation Coefficient (ICC) was adopted to analyze the consistency of the detection results between the manual measurement method and the designed intelligent detection program. Results:The designed intelligent measurement program in this study can automatically assess the detection parameters of quality control of the MSCT imaging system,which included CT values (water),noise and uniformity. There was favorable consistency in the detection results between the manual measurement method and the intelligent measurement program (range of ICC values was from 0.881 to 0.985). Conclusion:The intelligent measurement program of detection parameters of quality control of MSCT imaging system can simplify the process of calculating detection parameters of quality control of MSCT imaging system,and provide a reliable detection tool for quality control of MSCT imaging equipment,which can effectively improve the detection efficiency of quality control.
3.Efficacy and safety of LY01005 versus goserelin implant in Chinese patients with prostate cancer: A multicenter, randomized, open-label, phase III, non-inferiority trial.
Chengyuan GU ; Zengjun WANG ; Tianxin LIN ; Zhiyu LIU ; Weiqing HAN ; Xuhui ZHANG ; Chao LIANG ; Hao LIU ; Yang YU ; Zhenzhou XU ; Shuang LIU ; Jingen WANG ; Linghua JIA ; Xin YAO ; Wenfeng LIAO ; Cheng FU ; Zhaohui TAN ; Guohua HE ; Guoxi ZHU ; Rui FAN ; Wenzeng YANG ; Xin CHEN ; Zhizhong LIU ; Liqiang ZHONG ; Benkang SHI ; Degang DING ; Shubo CHEN ; Junli WEI ; Xudong YAO ; Ming CHEN ; Zhanpeng LU ; Qun XIE ; Zhiquan HU ; Yinhuai WANG ; Hongqian GUO ; Tiwu FAN ; Zhaozhao LIANG ; Peng CHEN ; Wei WANG ; Tao XU ; Chunsheng LI ; Jinchun XING ; Hong LIAO ; Dalin HE ; Zhibin WU ; Jiandi YU ; Zhongwen FENG ; Mengxiang YANG ; Qifeng DOU ; Quan ZENG ; Yuanwei LI ; Xin GOU ; Guangchen ZHOU ; Xiaofeng WANG ; Rujian ZHU ; Zhonghua ZHANG ; Bo ZHANG ; Wanlong TAN ; Xueling QU ; Hongliang SUN ; Tianyi GAN ; Dingwei YE
Chinese Medical Journal 2023;136(10):1207-1215
BACKGROUND:
LY01005 (Goserelin acetate sustained-release microsphere injection) is a modified gonadotropin-releasing hormone (GnRH) agonist injected monthly. This phase III trial study aimed to evaluated the efficacy and safety of LY01005 in Chinese patients with prostate cancer.
METHODS:
We conducted a randomized controlled, open-label, non-inferiority trial across 49 sites in China. This study included 290 patients with prostate cancer who received either LY01005 or goserelin implants every 28 days for three injections. The primary efficacy endpoints were the percentage of patients with testosterone suppression ≤50 ng/dL at day 29 and the cumulative probability of testosterone ≤50 ng/dL from day 29 to 85. Non-inferiority was prespecified at a margin of -10%. Secondary endpoints included significant castration (≤20 ng/dL), testosterone surge within 72 h following repeated dosing, and changes in luteinizing hormone, follicle-stimulating hormone, and prostate specific antigen levels.
RESULTS:
On day 29, in the LY01005 and goserelin implant groups, testosterone concentrations fell below medical-castration levels in 99.3% (142/143) and 100% (140/140) of patients, respectively, with a difference of -0.7% (95% confidence interval [CI], -3.9% to 2.0%) between the two groups. The cumulative probabilities of maintaining castration from days 29 to 85 were 99.3% and 97.8%, respectively, with a between-group difference of 1.5% (95% CI, -1.3% to 4.4%). Both results met the criterion for non-inferiority. Secondary endpoints were similar between groups. Both treatments were well-tolerated. LY01005 was associated with fewer injection-site reactions than the goserelin implant (0% vs . 1.4% [2/145]).
CONCLUSION:
LY01005 is as effective as goserelin implants in reducing testosterone to castration levels, with a similar safety profile.
TRIAL REGISTRATION
ClinicalTrials.gov, NCT04563936.
Humans
;
Male
;
Antineoplastic Agents, Hormonal/therapeutic use*
;
East Asian People
;
Gonadotropin-Releasing Hormone/agonists*
;
Goserelin/therapeutic use*
;
Prostate-Specific Antigen
;
Prostatic Neoplasms/drug therapy*
;
Testosterone
4.Practical Value of Environment-friendly Sample Release Agent Combined with Ultrasound in the Preparation of Pathological Tissue Sections
Yan-xing WU ; Chao-hua MO ; Fu-lan HAN ; Min ZENG ; Zeng-wei CHEN ; Wen-xiong YANG ; Xin-ye ZHOU ; Rong-jun MAO
Journal of Sun Yat-sen University(Medical Sciences) 2023;44(5):847-853
ObjectiveTo explore the practical value of environment-friendly sample release agent combined with ultrasound in the preparation of pathological tissue sections. MethodsFrom February 2013 to December 2022, 2 518 pathological specimens submitted by Foshan Municipal Hospital of Traditional Chinese Medicine were selected as the study objects. Two samples of the same specimen were randomly divided into two groups: the environment-friendly fast group, in which the pathological tissue sections were made by using the environment-friendly sample release agent combined with ultrasound; and the traditional group, in which formaldehyde, ethanol and xylene were used to make slices in the conventional way. The differences of hematoxylin (HE) staining effect, immunohistochemistry (IHC) staining effect and MDM2 gene detection result of atypical lipomatous tumor/highly differentiated liposarcoma (ALT/WDL) tissue sections between the two groups were compared. Results① The wax of the two groups' pathological tissues was dehydrated well and the tissue hardness was moderate. After HE staining, the sections of the two groups were intact, without cracks and tremor marks, and the contrast between nucleus and cytoplasm was appropriate, with good transparency, uniform staining, and no tissue loss. The excellent rate and score of HE staining in the environmental fast group were higher than those in the traditional group, but the difference was not statistically significant (χ2 = 3.125,P1 = 0.070;t = 0.965,P2 = 0.334). ②After IHC staining of the two groups of sections, the positive location of the cells was accurate, the staining was specific and uniform, the staining intensity was moderate, the staining sensitivity was good, and there was no tissue loss. The excellent rate of IHC staining and the positive rate of IHC staining in the environmental fast group were lower than those in the traditional group, but the difference was not statistically significant (χ12 = 2.769,P1 = 0.092;χ22 = 0.800,P2 = 0.375). ③The background and outline of the two groups of WDL tissue sections were clear, the staining was uniform, the cells were clear and visible, the nuclear boundary was clear, the hybridization signal was clear and bright under the background fluorescence, and there was no miscellaneous signal. The two groups of sections were hybridized successfully, and MDM2 showed positive amplification. The number of cells successfully hybridized in the environment-friendly fast group was lower than that in the traditional group, but the difference was not statistically significant (t = 1.414,P = 0.230). ConclusionsThe tissue treatment method of using environment-friendly sample release agent combined with ultrasound can ensure the detection effect of HE staining, IHC staining and MDM2 gene detection of pathological tissue sections, and is more efficient and environment-friendly, suitable for promotion and use in hospitals at all levels.
5.Discussion on
Chang-Zhen GONG ; Fan-Rong LIANG ; Can-Hui LI ; Wei-Xing PAN ; Yong-Ming LI ; San-Hua LENG ; Arthur Yin FAN ; Song-Ping HAN ; Jing LIU ; Shan WANG ; Zeng-Fu PENG ; Ye-Meng CHEN ; Guan-Hu YANG ; Xu-Ming GU ; Hong SU ; Shao-Bai WANG
Chinese Acupuncture & Moxibustion 2021;41(4):359-364
Professor
Acupuncture
;
Acupuncture Therapy
;
Angina, Stable
;
Combined Modality Therapy
;
Humans
;
Moxibustion
6.Expert consensus on microbiome sequencing and analysis.
Yunfeng DUAN ; Shengyue WANG ; Yubao CHEN ; Ruifu YANG ; Houkai LI ; Huaiqiu ZHU ; Yigang TONG ; Wenbin WU ; Yu FU ; Songnian HU ; Jun WANG ; Yuhua XIN ; Fangqing ZHAO ; Yiming BAO ; Wen ZHANG ; Juan LI ; Ming ZENG ; Haitao NIU ; Xin ZHOU ; Yan LI ; Shenghui CUI ; Jing YUAN ; Junhua LI ; Jiayi WANG ; Donglai LIU ; Ming NI ; Qing SUN ; Ye DENG ; Baoli ZHU
Chinese Journal of Biotechnology 2020;36(12):2516-2524
In the past ten years, the research and application of microbiome has continued to increase. The microbiome has gradually become the research focus in the fields of life science, environmental science, and medicine. Meanwhile, many countries and organizations around the world are launching their own microbiome projects and conducting a multi-faceted layout, striving to gain a strategic position in this promising field. In addition, whether it is scientific research or industrial applications, there has been a climax of research and a wave of investment and financing, accordingly, products and services related to the microbiome are constantly emerging. However, due to the rapid development of microbiome sequencing and analysis related technologies and methods, the research and application from various countries have not yet unified on the standards of technology, programs, and data. Domestic industry participants also have insufficient understanding of the microbiome. New methods, technologies, and theories have not yet been fully accepted and used. In addition, some of the existing standards and guidelines are too general with poor practicality. This not only causes obstacles in the integration of scientific research data and waste of resources, but also gives related companies unfair competition opportunity. More importantly, China still lacks national standards related to the microbiome, and the national microbiome project is still in the process of preparation. In this context, the experts and practitioners of the microbiome worked together and developed the consensus of experts. It can not only guide domestic scientific research and industrial institutions to regulate the production, learning and research of the microbiome, the application can also provide reference technical basis for the relevant national functional departments, protect the scale and standardized corporate company's interests, strengthen industry self-discipline, avoid unregulated enterprises from disrupting the market, and ultimately promote the benign development of microbiome-related industries.
China
;
Consensus
;
Humans
;
Industry
;
Microbiota
7.A multicenter survey of antibiotic use in very and extremely low birth weight infants in Hunan Province.
Ming-Jie WANG ; Shao-Jie YUE ; Jin LIN ; Xi-Rong GAO ; Xiao-Ming PENG ; Meng-Yu CHEN ; Hua-Bao PENG ; Bei CAO ; Yun-Qing ZENG ; Shu-Lian WANG ; Bo WEN ; Xi-Lin HUANG ; Xiao-Ping LI ; Ai-Zhen ZHANG ; Ting CAO ; Yi-Hua CHEN ; Tie-Qiang CHEN ; Chun-Hua YE ; Tao BO ; De-Lin JIANG ; Xiu-Qun HUANG ; Na-Fang REN ; Long-Zhang TAO ; Fang YAO ; Chang-Jun TIAN ; Hong-Ming LI ; Ai-Min ZHANG ; Fu-Rong HUANG ; Wei-Guo ZHANG ; Xiang-Hong CHEN ; Yu-Chan LIU ; Zheng-Lin LIU ; Yan-Shan XU ; Jing-Song MING ; Li CHEN ; Ning-Yi ZHU ; Jun-Min HE ; Sai-Jun YI ; Tuan-Mei WANG ; Zhao-Hui LI ; Gui-Tian WANG
Chinese Journal of Contemporary Pediatrics 2020;22(6):561-566
OBJECTIVE:
To investigate the current status of antibiotic use for very and extremely low birth weight (VLBW/ELBW) infants in neonatal intensive care units (NICUs) of Hunan Province.
METHODS:
The use of antibiotics was investigated in multiple level 3 NICUs of Hunan Province for VLBW and ELBW infants born between January, 2017 and December, 2017.
RESULTS:
The clinical data of 1 442 VLBW/ELBW infants were collected from 24 NICUs in 2017. The median antibiotic use duration was 17 days (range: 0-86 days), accounting for 53.0% of the total length of hospital stay. The highest duration of antibiotic use was up to 91.4% of the total length of hospital stay, with the lowest at 14.6%. In 16 out of 24 NICUs, the antibiotic use duration was accounted for more than 50.0% of the hospitalization days. There were 113 cases with positive bacterial culture grown in blood or cerebrospinal fluid, making the positive rate of overall bacterial culture as 7.84%. The positive rate of bacterial culture in different NICUs was significantly different from 0% to 14.9%. The common isolated bacterial pathogens Klebsiella pneumoniae was 29 cases (25.7%); Escherichia coli 12 cases (10.6%); Staphylococcus aureus 3 cases (2.7%). The most commonly used antibiotics were third-generation of cephalosporins, accounting for 41.00% of the total antibiotics, followed by penicillins, accounting for 32.10%, and followed by carbapenems, accounting for 13.15%. The proportion of antibiotic use time was negatively correlated with birth weight Z-score and the change in weight Z-score between birth and hospital discharge (r=-0.095, -0.151 respectively, P<0.01), positively correlated with death/withdrawal of care (r=0.196, P<0.01).
CONCLUSIONS
Antibiotics used for VLBW/ELBW infants in NICUs of Hunan Province are obviously prolonged in many NICUs. The proportion of routine use of third-generation of cephalosporins and carbapenems antibiotics is high among the NICUs.
Anti-Bacterial Agents
;
Birth Weight
;
Humans
;
Infant
;
Infant, Extremely Low Birth Weight
;
Infant, Newborn
;
Intensive Care Units, Neonatal
;
Surveys and Questionnaires
8. The clinical value of combined detection of serum angiopoietin 2 and Clara cell protein 16 in the early diagnosis of acute respiratory distress syndrome
Jianbin YE ; Jinle LIN ; Chao ZHONG ; Jianqing YE ; Min SHI ; Jian WEI ; Xuan FU ; Shiyong ZENG ; Wuyuan TAO ; Qinglin DOU ; Wenwu ZHANG
Chinese Journal of Emergency Medicine 2019;28(9):1112-1117
Objective:
To investigate the clinical value of combined detection of serum angiopoietin 2 (Ang-2) and Clara cell protein 16 (CC16) in the early diagnosis of acute respiratory distress syndrome (ARDS).
Methods:
Two hundred critical patients, treated at the Department of Critical Care Medicine, Bao'an District People's Hospital, Shenzhen during March 2015 and September 2016,were included in the study. According to the Berlin standard, patients were divided into two groups (
9.Ultrasonic appearances and misdiagnosis analysis of intrascrotal adenomatoid tumors
Qiaomin FU ; Linglin WEI ; Yong ZHUANG ; Xiaojian YE ; Jinshu ZENG
Chinese Journal of Medical Imaging Technology 2018;34(6):897-900
Objective To investigate the sonographic features and to analyze misdiagnosis causes of intrascrotal adenomatoid tumors.Methods Preoperative sonographic data of 15 patients confirmed as intrascrotal adenomatoid tumor by surgery and pathology were retrospectively analyzed.Compared with pathological results,the sonographic features and the misdiagnosis causes were analyzed.Results Among 15 patients,the tumors located at the tail of epididymis in 8 patients,at the head of epididymis in 5 patients and within the testis in 2 patients.The lesions were misdiagnosed as inflammatory diseases in 3 patients,as cysts in 3 and as malignant tumors in 2 patients,while in the others were indeterminate.Solid tumors were detected with ultrasound in 12 patients,while cystica in 3 patients.Among 12 patients with solid tumors,lesions in 7 patients had clear boundary and regular shape,while the boundary in the rest 5 patients were less clear.The internal echo was homogeneous in 6 patients and inhomogeneous in the rest 6 patients with echoless and punctate hyperecho.Cystic mass was characterized by polycystic with isolation belt.Among 15 patients of intrascrotal adenomatoid tumor,detectable blood flow signals were found in 8 patients,while no obvious blood flow signals were found in the rest 7 patients.Conclusion Ultrasonic features of intrascrotal adenomatoid tumor were less characteristic.Combination of clinical information and other imaging findings might help to decrease misdiagnosis.
10.Novel thioredoxin reductase inhibitor butaselen inhibits tumorigenesis by down-regulating programmed death-ligand 1 expression.
Qiao ZOU ; Yi-Fan CHEN ; Xiao-Qing ZHENG ; Suo-Fu YE ; Bin-Yuan XU ; Yu-Xi LIU ; Hui-Hui ZENG
Journal of Zhejiang University. Science. B 2018;19(9):689-698
The thioredoxin system plays a role in a variety of physiological functions, including cell growth, differentiation, apoptosis, tumorigenesis, and immunity. We previously confirmed that butaselen (BS), a novel thioredoxin reductase inhibitor, can inhibit the growth of various human cancer cell lines, yet the underlying mechanism remains elusive. In this study, we investigated the anti-tumor effect of BS in vivo through regulating the immune system of KM mice. We found that BS inhibits tumor proliferation by promoting the activation of splenic lymphocytes in mice. BS can elevate the percentage of CD4-CD8+ T lymphocytes and the secretion of downstream cytokines in mice via down-regulating the expression of programmed death-ligand 1 (PD-L1) on the tumor cells' surface in vivo. Further study in HepG2 and BEL-7402 cells showed that decrease of PD-L1 level after BS treatment was achieved by inhibiting signal transducer and activator of transcription 3 (STAT3) phosphorylation. Taken together, our results suggest that BS has a role in promoting the immune response by reducing PD-L1 expression via the STAT3 pathway, and subsequently suppresses tumorigenesis.
Animals
;
Antineoplastic Agents/pharmacology*
;
B7-H1 Antigen/antagonists & inhibitors*
;
Benzene Derivatives/therapeutic use*
;
CD8-Positive T-Lymphocytes/drug effects*
;
Hep G2 Cells
;
Humans
;
Liver Neoplasms/pathology*
;
Male
;
Mice
;
Organoselenium Compounds/therapeutic use*
;
STAT3 Transcription Factor/physiology*
;
Thioredoxin-Disulfide Reductase/antagonists & inhibitors*
;
Tumor Burden/drug effects*

Result Analysis
Print
Save
E-mail