1.A preliminary study of risk factors for the stress fracture in treated with clavicle hook plate.
Peng-Fei NIE ; Yuan-Lin XU ; Yong-Fu LI ; Lun ZHANG ; Qian-Qian ZHOU ; Jian-Nyu LUO ; Jian GUO
China Journal of Orthopaedics and Traumatology 2025;38(1):61-65
OBJECTIVE:
To investigate the effects of bone density, plate bending degree and proximal screw type on the stress fracture of clavicle hook.
METHODS:
Three sows weighing between 45 and 50 kg were selected, from which a total of 40 rivs were collected. The 15 ribs of sows were divided into 3 groups according to bone density and bone hardness with 5 rivs in each group. And then the 3 groups were fixed with 6-hole collarbone hook plates and 3 locking screws. Measure the maximum torsion force when the ribs were fractured by force. The same size 15 rids were divided into 3 groups, named forward bending group, 0° group(the angle between the plate surface and the rib surface) and reverse bending group. All fixed with 6-hole collarbone hook plates and locking screws to measure the maximum torsion force of rib stress fracture. Then the same size 10 rids were divided into 2 groups, the normal screw group and the locking screw group with 5 ribs in each group. Both groups were fixed with 6-hole collarbone hook plates and screws. The normal screw group was a normal screw, fixed in proximal end, and two locking screws. The locking screw group was fixed by locking screws. Measure the maximum torsion force of the two groups when the ribs fracture by force.
RESULTS:
In the bone density experiment, the torque force of hard bone group (104.51±6.27) N was greater than the normal bone group (75.04±3.81) N(t=8.979, P<0.05). The force of normal bone group was greater than the osteoporosis group (49.99±2.12) N(t=12.832, P<0.05). In the bending collarbone hook experiment, the order of the torque force generated by each group as follow:the forward bending group (343.59±6.18) N greater than the 0° group (106.01±5.29) N(t=65.279, P<0.05) greater than the reverse bending group (95.82±4.12) N(t=3.398, P<0.05). The force of the normal screw group (98.68±0.70) N was greater than the locking screw group (50.20±0.95) N(t=91.484, P<0.05). The data comparisons of each group were statistically significant.
CONCLUSION
Bone density, plate bending degree and proximal screw type had an impact on stress fracture of clavicle hook plate. Higher bone density, forward bending of the steel plate, and ordinary screws in proximal end can reduce the rates of stress fractures of clavicle hooks.
Animals
;
Bone Plates
;
Clavicle/surgery*
;
Swine
;
Fractures, Stress/etiology*
;
Female
;
Risk Factors
;
Fracture Fixation, Internal/instrumentation*
;
Bone Screws
;
Biomechanical Phenomena
;
Bone Density
2.Clinical practice guidelines for the diagnosis and treatment of atopic dermatitis with integrative traditional Chinese and Western medicine.
Xin-Ran DU ; Meng-Yi WU ; Mao-Can TAO ; Ying LIN ; Chao-Ying GU ; Min-Feng WU ; Yi CAO ; Da-Can CHEN ; Wei LI ; Hong-Wei WANG ; Ying WANG ; Yi WANG ; Han-Zhi LU ; Xin LIU ; Xiang-Fei SU ; Fu-Lun LI
Journal of Integrative Medicine 2025;23(6):641-653
Traditional Chinese medicine (TCM) is a well-accepted therapy for atopic dermatitis (AD). However, there are currently no evidence-based guidelines integrating TCM and Western medicine for the treatment of AD, limiting the clinical application of such combined approaches. Therefore, the China Association of Chinese Medicine initiated the development of the current guideline, focusing on key issues related to the use of TCM in the treatment of AD. This guideline was developed in accordance with the principles of the guideline formulation manual published by the World Health Organization. A comprehensive review of the literature on the combined use of TCM and Western medicine to treat AD was conducted. The findings were extensively discussed by experts in dermatology and pharmacy with expertise in both TCM and Western medicine. This guideline comprises 23 recommendations across seven major areas, including TCM syndrome differentiation and classification of AD, principles and application scenarios of TCM combined with Western medicine for treating AD, outcome indicators for evaluating clinical efficacy of AD treatment, integration of TCM pattern classification and Western medicine across disease stages, daily management of AD, the use of internal TCM therapies and proprietary Chinese medicines, and TCM external treatments. Please cite this article as: Du XR, Wu MY, Tao MC, Lin Y, Gu CY, Wu MF, Cao Y, Chen DC, Li W, Wang HW, Wang Y, Wang Y, Lu HZ, Liu X, Su XF, Li FL. Clinical practice guidelines for the diagnosis and treatment of atopic dermatitis with integrative traditional Chinese and Western medicine. J Integr Med. 2025; 23(6):641-653.
Dermatitis, Atopic/drug therapy*
;
Humans
;
Medicine, Chinese Traditional/methods*
;
Integrative Medicine
;
Drugs, Chinese Herbal/therapeutic use*
;
Practice Guidelines as Topic
3.Mechanosensory activation of Piezo1 via cupping therapy: Harnessing neural networks to modulate AMPK pathway for metabolic restoration in a mouse model of psoriasis.
Ruo-Fan XI ; Xin LIU ; Yi WANG ; Han-Zhi LU ; Shao-Jie YUAN ; Dong-Jie GUO ; Jian-Yong ZHU ; Fu-Lun LI ; Yan-Juan DUAN
Journal of Integrative Medicine 2025;23(6):721-732
OBJECTIVE:
Psoriasis, a common chronic inflammatory skin condition with genetic underpinnings, is traditionally managed with cupping therapy. Although used historically, the precise mechanical effects and therapeutic mechanisms of cupping in psoriasis remain largely unexamined. This study aimed to evaluate cupping therapy's efficacy for psoriasis and investigate its role in modulating inflammatory responses and cellular metabolism.
METHODS:
Psoriasis was induced in mice using topical imiquimod (IMQ). The effects of cupping on psoriatic lesions were assessed using the Psoriasis Area and Severity Index score, histology, immunohistochemistry, and immunofluorescence staining. polymerase chain reaction sequencing (RNA-seq) and Western blotting were conducted to examine changes in mRNA expression and the AMP-activated protein kinase (AMPK) signaling pathway.
RESULTS:
Cupping therapy significantly reduced inflammation, epidermal thickness, and inflammatory cell infiltration in mice with IMQ-induced psoriasis. Immunohistochemistry and immunofluorescence showed lower expression of inflammatory markers and a shift in T-cell populations. RNA-seq and Western blotting indicated that cupping upregulated Piezo1 and activated the AMPK pathway, improving energy metabolism in psoriatic skin.
CONCLUSION
Cupping therapy reduces epidermal hyperproliferation and inflammation in psoriasis, rebalancing the local immune microenvironment. Mechanistically, cupping promotes calcium influx via Piezo1, activates AMPK signaling, and supports metabolic homeostasis, suggesting therapeutic potential for psoriasis. Please cite this article as: Xi RF, Liu X, Wang Y, Lu HZ, Yuan SJ, Guo DJ, Zhu JY, Li FL, Duan YJ. Mechanosensory activation of Piezo1 via cupping therapy: Harnessing neural networks to modulate AMPK pathway for metabolic restoration in a mouse model of psoriasis. J Integr Med. 2025; 23(6):721-732.
Animals
;
Psoriasis/chemically induced*
;
Mice
;
AMP-Activated Protein Kinases/metabolism*
;
Disease Models, Animal
;
Cupping Therapy/methods*
;
Signal Transduction
;
Imiquimod
;
Ion Channels/genetics*
;
Male
;
Mechanotransduction, Cellular
4.Evaluation of chemical constituent consistency in formula granules and traditional decoctions of Gouteng Jiangya Formula
Qing-gang ZHANG ; Dai-liang ZHANG ; Hong QI ; Shu-wen DING ; Yu-zhuo WANG ; Yun-lun LI ; Ji-fu HE ; Huan-ying GUO ; Gui-yun CAO ; Zhao-qing MENG
Chinese Traditional Patent Medicine 2025;47(11):3555-3565
AIM To evaluate the chemical constituent consistency in formula granules and traditional decoctions of Gouteng Jiangya Formula.METHODS HPLC characteristic chromatograms were established,the analysis was performed on a 30 ℃ thermostatic YMC-Triart C18 column(4.6 mm× 250 mm,5 μm),with the mobile phase comprising of acetonitrile-0.2%phosphoric acid flowing at 1.0 mL/min in a gradient elution manner,and the detection wavelength was set at 240 nm.Puerarin was used as an internal standard to calculate the relative correction factors of 3'-methoxy puerarin,puerarin apioside,magnolflorine,paeoniflora,daidzin,baicalin,palmatine,berberine,wogonoside and benzoylpaeoniflorin,after which the content detemination was made by quantitative analysis of multi-components by single-marker(QAMS).RESULTS The characteristic chromatograms of 9 batches of formula granules and 15 bacthes of traditional decoctions demonstrated the similarities of more than 0.90 at the detection wavelengths of 192,210,240,260,280,300,320,360 nm,along with similar total peak areas.Eleven constituents showed good linear relationships within their own ranges(r>0.999 0),whose average recoveries were 97.27%-101.64%with the RSDs of 0.36%-1.11%,the result obtained by QAMS and external standard method demonstrated no significant differences(P>0.05).The contents of various constituents in the formula granules approximated those in the traditional decoctions.CONCLUSION The consistent kinds and contents of various constituents are obversable in formula granules and traditional decoctions of Gouteng Jiangya Formula,which can provide a reference for the reasonable clinical application of this formula.
5.Evaluation of chemical constituent consistency in formula granules and traditional decoctions of Gouteng Jiangya Formula
Qing-gang ZHANG ; Dai-liang ZHANG ; Hong QI ; Shu-wen DING ; Yu-zhuo WANG ; Yun-lun LI ; Ji-fu HE ; Huan-ying GUO ; Gui-yun CAO ; Zhao-qing MENG
Chinese Traditional Patent Medicine 2025;47(11):3555-3565
AIM To evaluate the chemical constituent consistency in formula granules and traditional decoctions of Gouteng Jiangya Formula.METHODS HPLC characteristic chromatograms were established,the analysis was performed on a 30 ℃ thermostatic YMC-Triart C18 column(4.6 mm× 250 mm,5 μm),with the mobile phase comprising of acetonitrile-0.2%phosphoric acid flowing at 1.0 mL/min in a gradient elution manner,and the detection wavelength was set at 240 nm.Puerarin was used as an internal standard to calculate the relative correction factors of 3'-methoxy puerarin,puerarin apioside,magnolflorine,paeoniflora,daidzin,baicalin,palmatine,berberine,wogonoside and benzoylpaeoniflorin,after which the content detemination was made by quantitative analysis of multi-components by single-marker(QAMS).RESULTS The characteristic chromatograms of 9 batches of formula granules and 15 bacthes of traditional decoctions demonstrated the similarities of more than 0.90 at the detection wavelengths of 192,210,240,260,280,300,320,360 nm,along with similar total peak areas.Eleven constituents showed good linear relationships within their own ranges(r>0.999 0),whose average recoveries were 97.27%-101.64%with the RSDs of 0.36%-1.11%,the result obtained by QAMS and external standard method demonstrated no significant differences(P>0.05).The contents of various constituents in the formula granules approximated those in the traditional decoctions.CONCLUSION The consistent kinds and contents of various constituents are obversable in formula granules and traditional decoctions of Gouteng Jiangya Formula,which can provide a reference for the reasonable clinical application of this formula.
6.Innovative Nerve Root Protection in Full-Endoscopic Facet-Resecting Lumbar Interbody Fusion: Controlled Cage Glider Rotation Using the GUARD (Glider Used As a Rotary Device) Technique
Yu-Chia HSU ; Hao-Chun CHUANG ; Wei-Lun CHANG ; Yuan-Fu LIU ; Chao-Jui CHANG ; Yu-Meng HSIAO ; Yi-Hung HUANG ; Keng-Chang LIU ; Chien-Min CHEN ; Hyeun-Sung KIM ; Cheng-Li LIN
Neurospine 2024;21(4):1141-1148
This video presents a case of L4–5 unstable spondylolisthesis treated with full-endoscopic transforaminal lumbar interbody fusion (Endo-TLIF), emphasizing the GUARD (Glider Used as a Rotary Device) technique for nerve root protection. This innovative approach involves controlled rotation of the cage glider before cage insertion to minimize the risk of nerve root injury, a significant complication in Endo-TLIF procedures. The GUARD technique, validated in previous cadaveric studies, provides enhanced safety during cage insertion by protecting the nerve root. A 48-year-old woman with a 3-year history of progressive low back pain and bilateral lower extremity radiculopathy (right-sided predominance) was diagnosed with L4–5 unstable spondylolisthesis and spinal stenosis. After failure of conservative management, she underwent uniportal full-endoscopic facet-resecting transforaminal lumbar interbody fusion using the GUARD technique. Postoperatively, the patient experienced significant symptomatic improvement and resolution of radiculopathy, without any intraoperative nerve root injury or postoperative neurological deficits. This case demonstrates the effectiveness of the GUARD technique in reducing neurological complications and improving patient outcomes.
7.Innovative Nerve Root Protection in Full-Endoscopic Facet-Resecting Lumbar Interbody Fusion: Controlled Cage Glider Rotation Using the GUARD (Glider Used As a Rotary Device) Technique
Yu-Chia HSU ; Hao-Chun CHUANG ; Wei-Lun CHANG ; Yuan-Fu LIU ; Chao-Jui CHANG ; Yu-Meng HSIAO ; Yi-Hung HUANG ; Keng-Chang LIU ; Chien-Min CHEN ; Hyeun-Sung KIM ; Cheng-Li LIN
Neurospine 2024;21(4):1141-1148
This video presents a case of L4–5 unstable spondylolisthesis treated with full-endoscopic transforaminal lumbar interbody fusion (Endo-TLIF), emphasizing the GUARD (Glider Used as a Rotary Device) technique for nerve root protection. This innovative approach involves controlled rotation of the cage glider before cage insertion to minimize the risk of nerve root injury, a significant complication in Endo-TLIF procedures. The GUARD technique, validated in previous cadaveric studies, provides enhanced safety during cage insertion by protecting the nerve root. A 48-year-old woman with a 3-year history of progressive low back pain and bilateral lower extremity radiculopathy (right-sided predominance) was diagnosed with L4–5 unstable spondylolisthesis and spinal stenosis. After failure of conservative management, she underwent uniportal full-endoscopic facet-resecting transforaminal lumbar interbody fusion using the GUARD technique. Postoperatively, the patient experienced significant symptomatic improvement and resolution of radiculopathy, without any intraoperative nerve root injury or postoperative neurological deficits. This case demonstrates the effectiveness of the GUARD technique in reducing neurological complications and improving patient outcomes.
8.Innovative Nerve Root Protection in Full-Endoscopic Facet-Resecting Lumbar Interbody Fusion: Controlled Cage Glider Rotation Using the GUARD (Glider Used As a Rotary Device) Technique
Yu-Chia HSU ; Hao-Chun CHUANG ; Wei-Lun CHANG ; Yuan-Fu LIU ; Chao-Jui CHANG ; Yu-Meng HSIAO ; Yi-Hung HUANG ; Keng-Chang LIU ; Chien-Min CHEN ; Hyeun-Sung KIM ; Cheng-Li LIN
Neurospine 2024;21(4):1141-1148
This video presents a case of L4–5 unstable spondylolisthesis treated with full-endoscopic transforaminal lumbar interbody fusion (Endo-TLIF), emphasizing the GUARD (Glider Used as a Rotary Device) technique for nerve root protection. This innovative approach involves controlled rotation of the cage glider before cage insertion to minimize the risk of nerve root injury, a significant complication in Endo-TLIF procedures. The GUARD technique, validated in previous cadaveric studies, provides enhanced safety during cage insertion by protecting the nerve root. A 48-year-old woman with a 3-year history of progressive low back pain and bilateral lower extremity radiculopathy (right-sided predominance) was diagnosed with L4–5 unstable spondylolisthesis and spinal stenosis. After failure of conservative management, she underwent uniportal full-endoscopic facet-resecting transforaminal lumbar interbody fusion using the GUARD technique. Postoperatively, the patient experienced significant symptomatic improvement and resolution of radiculopathy, without any intraoperative nerve root injury or postoperative neurological deficits. This case demonstrates the effectiveness of the GUARD technique in reducing neurological complications and improving patient outcomes.
9.Innovative Nerve Root Protection in Full-Endoscopic Facet-Resecting Lumbar Interbody Fusion: Controlled Cage Glider Rotation Using the GUARD (Glider Used As a Rotary Device) Technique
Yu-Chia HSU ; Hao-Chun CHUANG ; Wei-Lun CHANG ; Yuan-Fu LIU ; Chao-Jui CHANG ; Yu-Meng HSIAO ; Yi-Hung HUANG ; Keng-Chang LIU ; Chien-Min CHEN ; Hyeun-Sung KIM ; Cheng-Li LIN
Neurospine 2024;21(4):1141-1148
This video presents a case of L4–5 unstable spondylolisthesis treated with full-endoscopic transforaminal lumbar interbody fusion (Endo-TLIF), emphasizing the GUARD (Glider Used as a Rotary Device) technique for nerve root protection. This innovative approach involves controlled rotation of the cage glider before cage insertion to minimize the risk of nerve root injury, a significant complication in Endo-TLIF procedures. The GUARD technique, validated in previous cadaveric studies, provides enhanced safety during cage insertion by protecting the nerve root. A 48-year-old woman with a 3-year history of progressive low back pain and bilateral lower extremity radiculopathy (right-sided predominance) was diagnosed with L4–5 unstable spondylolisthesis and spinal stenosis. After failure of conservative management, she underwent uniportal full-endoscopic facet-resecting transforaminal lumbar interbody fusion using the GUARD technique. Postoperatively, the patient experienced significant symptomatic improvement and resolution of radiculopathy, without any intraoperative nerve root injury or postoperative neurological deficits. This case demonstrates the effectiveness of the GUARD technique in reducing neurological complications and improving patient outcomes.
10.Innovative Nerve Root Protection in Full-Endoscopic Facet-Resecting Lumbar Interbody Fusion: Controlled Cage Glider Rotation Using the GUARD (Glider Used As a Rotary Device) Technique
Yu-Chia HSU ; Hao-Chun CHUANG ; Wei-Lun CHANG ; Yuan-Fu LIU ; Chao-Jui CHANG ; Yu-Meng HSIAO ; Yi-Hung HUANG ; Keng-Chang LIU ; Chien-Min CHEN ; Hyeun-Sung KIM ; Cheng-Li LIN
Neurospine 2024;21(4):1141-1148
This video presents a case of L4–5 unstable spondylolisthesis treated with full-endoscopic transforaminal lumbar interbody fusion (Endo-TLIF), emphasizing the GUARD (Glider Used as a Rotary Device) technique for nerve root protection. This innovative approach involves controlled rotation of the cage glider before cage insertion to minimize the risk of nerve root injury, a significant complication in Endo-TLIF procedures. The GUARD technique, validated in previous cadaveric studies, provides enhanced safety during cage insertion by protecting the nerve root. A 48-year-old woman with a 3-year history of progressive low back pain and bilateral lower extremity radiculopathy (right-sided predominance) was diagnosed with L4–5 unstable spondylolisthesis and spinal stenosis. After failure of conservative management, she underwent uniportal full-endoscopic facet-resecting transforaminal lumbar interbody fusion using the GUARD technique. Postoperatively, the patient experienced significant symptomatic improvement and resolution of radiculopathy, without any intraoperative nerve root injury or postoperative neurological deficits. This case demonstrates the effectiveness of the GUARD technique in reducing neurological complications and improving patient outcomes.

Result Analysis
Print
Save
E-mail