1.Consistent Detection of Aquaporin-4 Antibodies:A Comparative Analysis Between Fixed and Live Cell-Based Assays
Jing WANG ; Linge WANG ; Xiaolin YANG ; Zhizhong LI ; Jinyu JIANG ; Qiao XU ; Siyuan HUANG ; Qing FU ; Yang YANG ; Rongrong ZHANG ; Lin YANG ; Ai CHEN ; Xiaopeng ZENG ; Ke XU ; Peng ZHENG ; Xinyue QIN ; Jinzhou FENG
Journal of Clinical Neurology 2026;22(2):212-220
Background:
and Purpose Live cell-based assays (LCBA) are increasingly used for serological antibody detection due to their ability to preserve antigen conformation, offering moderately higher sensitivity than fixed cell-based assays. However, the clinical necessity of prioritizing LCBA for the detection of aquaporin-4 immunoglobulin G (AQP4-IgG) in neuromyelitis optica spectrum disorder (NMOSD) remains unclear, especially when compared to its established role in diagnosing myelin oligodendrocyte glycoprotein antibody-associated disease.
Methods:
We compared the performance of live cell-based assays using immunofluorescence (LCBA-IF) and fixed cell-based assays using immunofluorescence (FCBA-IF) in detecting AQP4-IgG in 90 cases of NMOSD meeting 2015 International Panel for Neuromyelitis Optica Diagnosis criteria, alongside 40 controls. Additionally, we further investigated the relationship between AQP4-IgG titers as measured by LCBA-IF and FCBA-IF and clinical parameters in NMOSD patients.
Results:
Results showed 96.9% agreement between LCBA-IF and FCBA-IF (Cohen’s κ=0.935), with a strong Spearman correlation (0.977, p<0.001). Both methods demonstrated 100% specificity, with LCBA-IF showing slightly higher sensitivity compared to FCBA-IF. Within LCBAIF-tested groups, statistically significant differences in annualized relapse rates were observed across all pairwise comparisons (low-titer vs. moderate-titer, low-titer vs. high-titer, and moderate-titer vs. high-titer; all p<0.050). However, this association reached statistical significance in some FCBA-IF-tested groups.
Conclusions
Overall, there is a strong concordance between LCBA-IF and FCBA-IF in detecting AQP4-IgG, where LCBA-IF shows slightly higher sensitivity. Furthermore, there is a potential link between elevated AQP4-IgG titers and an increased risk of relapse, and this correlation may appear more pronounced when using LCBA-IF.
2.Mosquito monitoring and influence of meteorological factors on mosquito density around Beijing Capital International Airport, 2016-2022
Ran FENG ; Tie-zheng MA ; Si-jie ZHU ; Bo TIAN ; Fei QUAN ; Zhi-lin WU ; Xiao-tao LIU ; Fu-yuan ZHANG ; Song-jian ZHANG
Acta Parasitologica et Medica Entomologica Sinica 2026;33(1):40-48
Objective To understand mosquito density, species composition, and seasonal variations around the Beijing Capital International Airport(BCIA)and provide scientific evidence for mosquito-borne disease prevention and control. Methods Meteorological data were collected from 2016 to 2022, and mosquito density was monitored at seven surveillance sites around the BCIA from May to October each year using CO2-baited mosquito traps to analyze the relationship between mosquito density and meteorological factors. Results In total,68 518 female mosquitoes were captured, with a mosquito density of 10.20 per light · hour. The dominant species was Culex pipiens pallens(73.90%), followed by Aedes albopictus(9.71%)and Ae. vexans(9.29%);the mosquito density was highest in 2016(14.8 per light·hour)and lowest in 2022(4.46 per light·hour). Significant statistical differences were observed in mosquito density among different species(F=18.118, P<0.05). The density of Cx. pipiens pallens and other mosquito species showed a mutually exclusive trend; the peak of mosquito density varied based on years and habitats, with significant statistical differences in mosquito density among different habitats(F=8.504, P<0.05). The highest mosquito density was observed near the Wenyu River(21.50 per light·hour), whereas the lowest was recorded at the BCIA construction site(2.44 per light· hour). The monthly average temperature(r=0.595), monthly average highest temperature(r=0.575), and monthly average lowest temperature(r=0.624)showed moderate positive correlations, whereas the monthly average air pressure(r=-0.484)showed a moderate negative correlation. The monthly average minimum temperature was included in the regression model(F=25.575, P<0.000), and the equation Y=1.029X4-8.181 was used. The monthly average air pressure 2 months prior(b=-2.418, β=-1.619, P<0.05)and the monthly average relative humidity(b=-0.739, β=-1.201, P<0.05)significantly negatively predicted the mosquito density. Notably, the regression equation used was y=2526.170+(-2.418)X9+(-0.739)X13. The exposure-response analysis revealed that the density of mosquitoes was not linearly related to the average monthly air pressure, rainfall, and duration of sunshine. Conclusions The dominant mosquito species around the BCIA was Cx. pipiens pallens, Ae. albopictus, and Ae. vexans. During the control of Cx. pipiens pallens, the impact on other mosquito species must also be considered. Environmental management, breeding sites, and scientific use of pesticides should be prioritized based on the activity periods of mosquitoes. Further studies on mosquitoes and meteorological factors should be conducted to provide references and novel avenues for mosquito control.
3.Qingda Granule Attenuates Hypertension-Induced Cardiac Damage via Regulating Renin-Angiotensin System Pathway.
Lin-Zi LONG ; Ling TAN ; Feng-Qin XU ; Wen-Wen YANG ; Hong-Zheng LI ; Jian-Gang LIU ; Ke WANG ; Zhi-Ru ZHAO ; Yue-Qi WANG ; Chao-Ju WANG ; Yi-Chao WEN ; Ming-Yan HUANG ; Hua QU ; Chang-Geng FU ; Ke-Ji CHEN
Chinese journal of integrative medicine 2025;31(5):402-411
OBJECTIVE:
To assess the efficacy of Qingda Granule (QDG) in ameliorating hypertension-induced cardiac damage and investigate the underlying mechanisms involved.
METHODS:
Twenty spontaneously hypertensive rats (SHRs) were used to develope a hypertension-induced cardiac damage model. Another 10 Wistar Kyoto (WKY) rats were used as normotension group. Rats were administrated intragastrically QDG [0.9 g/(kg•d)] or an equivalent volume of pure water for 8 weeks. Blood pressure, histopathological changes, cardiac function, levels of oxidative stress and inflammatory response markers were measured. Furthermore, to gain insights into the potential mechanisms underlying the protective effects of QDG against hypertension-induced cardiac injury, a network pharmacology study was conducted. Predicted results were validated by Western blot, radioimmunoassay immunohistochemistry and quantitative polymerase chain reaction, respectively.
RESULTS:
The administration of QDG resulted in a significant decrease in blood pressure levels in SHRs (P<0.01). Histological examinations, including hematoxylin-eosin staining and Masson trichrome staining revealed that QDG effectively attenuated hypertension-induced cardiac damage. Furthermore, echocardiography demonstrated that QDG improved hypertension-associated cardiac dysfunction. Enzyme-linked immunosorbent assay and colorimetric method indicated that QDG significantly reduced oxidative stress and inflammatory response levels in both myocardial tissue and serum (P<0.01).
CONCLUSIONS
Both network pharmacology and experimental investigations confirmed that QDG exerted its beneficial effects in decreasing hypertension-induced cardiac damage by regulating the angiotensin converting enzyme (ACE)/angiotensin II (Ang II)/Ang II receptor type 1 axis and ACE/Ang II/Ang II receptor type 2 axis.
Animals
;
Drugs, Chinese Herbal/therapeutic use*
;
Hypertension/pathology*
;
Renin-Angiotensin System/drug effects*
;
Rats, Inbred SHR
;
Oxidative Stress/drug effects*
;
Male
;
Rats, Inbred WKY
;
Blood Pressure/drug effects*
;
Myocardium/pathology*
;
Rats
;
Inflammation/pathology*
4.Pneumothorax during pediatric laparoscopic high ligation of hernia sac: A case report.
Yuan LIN ; Zhujun HUANG ; Mingzhi ZHENG ; Weidong FU ; Liu LUO ; Lin TANG
Journal of Central South University(Medical Sciences) 2025;50(8):1475-1482
Pneumothorax during pediatric laparoscopic surgery is a potentially fatal complication that may not be promptly recognized. It can occur due to congenital anatomical abnormalities, pre-existing pulmonary disease, or operative factors during laparoscopy. Clinical presentation may range from asymptomatic to acute respiratory distress, pleuritic chest pain, and even life-threatening circulatory collapse. Here, we report a case of sudden intraoperative pneumothorax accompanied by extensive subcutaneous emphysema of the neck and chest wall during laparoscopic high ligation of the hernial sac in a child. The child presented with a reducible left lower abdominal mass and mild pain 3 days prior but did not seek medical attention. Symptoms worsened 1 day prior to admission, with difficulty reducing the mass. On April 8, 2021, the patient was admitted to the Department of Anesthesiology, Zhuzhou Hospital Affiliated to Xiangya School of Medicine of Central South University, with a diagnosis of "left inguinal hernia." On the second day of hospitalization, laparoscopic high ligation of the left inguinal hernia sac was performed under general anesthesia. During the procedure, the patient developed a sudden increase in airway pressure, marked hemodynamic fluctuations, crepitus in the neck and right anterior chest regions, and significantly diminished breath sounds in the right lung. Emergent bedside chest X-ray confirmed a right-sided pneumothorax. Immediate intervention including thoracic needle decompression, closed thoracic drainage, the lung re-expansion was performed. The patient was discharged on the 7th postoperative day with full recovery. This case highlights the need for clinicians to remain vigilant for iatrogenic pneumothorax during pediatric laparoscopic surgery. Close intraoperative monitoring of vital signs is crucial for early detection, recognition, and timely management of pneumothorax to ensure patient safety during minimally invasive procedures.
Humans
;
Laparoscopy/methods*
;
Pneumothorax/etiology*
;
Ligation/methods*
;
Hernia, Inguinal/surgery*
;
Male
;
Intraoperative Complications/etiology*
;
Child
;
Herniorrhaphy/methods*
;
Female
;
Subcutaneous Emphysema/etiology*
5.The protein arginine methyltransferase PRMT1 ameliorates cerebral ischemia-reperfusion injury by suppressing RIPK1-mediated necroptosis and apoptosis.
Tengfei LIU ; Gan HUANG ; Xin GUO ; Qiuran JI ; Lu YU ; Runzhe ZONG ; Yiquan LI ; Xiaomeng SONG ; Qingyi FU ; Qidi XUE ; Yi ZHENG ; Fanshuo ZENG ; Ru SUN ; Lin CHEN ; Chengjiang GAO ; Huiqing LIU
Acta Pharmaceutica Sinica B 2025;15(8):4014-4029
Receptor-interacting protein kinase 1 (RIPK1) plays an essential role in regulating the necroptosis and apoptosis in cerebral ischemia-reperfusion (I/R) injury. However, the regulation of RIPK1 kinase activity after cerebral I/R injury remains largely unknown. In this study, we found the downregulation of protein arginine methyltransferase 1 (PRMT1) was induced by cerebral I/R injury, which negatively correlated with the activation of RIPK1. Mechanistically, we proved that PRMT1 directly interacted with RIPK1 and catalyzed its asymmetric dimethylarginine, which then blocked RIPK1 homodimerization and suppressed its kinase activity. Moreover, pharmacological inhibition or genetic ablation of PRMT1 aggravated I/R injury by promoting RIPK1-mediated necroptosis and apoptosis, while PRMT1 overexpression protected against I/R injury by suppressing RIPK1 activation. Our findings revealed the molecular regulation of RIPK1 activation and demonstrated PRMT1 would be a potential therapeutic target for the treatment of ischemic stroke.
6.Glutamine signaling specifically activates c-Myc and Mcl-1 to facilitate cancer cell proliferation and survival.
Meng WANG ; Fu-Shen GUO ; Dai-Sen HOU ; Hui-Lu ZHANG ; Xiang-Tian CHEN ; Yan-Xin SHEN ; Zi-Fan GUO ; Zhi-Fang ZHENG ; Yu-Peng HU ; Pei-Zhun DU ; Chen-Ji WANG ; Yan LIN ; Yi-Yuan YUAN ; Shi-Min ZHAO ; Wei XU
Protein & Cell 2025;16(11):968-984
Glutamine provides carbon and nitrogen to support the proliferation of cancer cells. However, the precise reason why cancer cells are particularly dependent on glutamine remains unclear. In this study, we report that glutamine modulates the tumor suppressor F-box and WD repeat domain-containing 7 (FBW7) to promote cancer cell proliferation and survival. Specifically, lysine 604 (K604) in the sixth of the 7 substrate-recruiting WD repeats of FBW7 undergoes glutaminylation (Gln-K604) by glutaminyl tRNA synthetase. Gln-K604 inhibits SCFFBW7-mediated degradation of c-Myc and Mcl-1, enhances glutamine utilization, and stimulates nucleotide and DNA biosynthesis through the activation of c-Myc. Additionally, Gln-K604 promotes resistance to apoptosis by activating Mcl-1. In contrast, SIRT1 deglutaminylates Gln-K604, thereby reversing its effects. Cancer cells lacking Gln-K604 exhibit overexpression of c-Myc and Mcl-1 and display resistance to chemotherapy-induced apoptosis. Silencing both c-MYC and MCL-1 in these cells sensitizes them to chemotherapy. These findings indicate that the glutamine-mediated signal via Gln-K604 is a key driver of cancer progression and suggest potential strategies for targeted cancer therapies based on varying Gln-K604 status.
Glutamine/metabolism*
;
Myeloid Cell Leukemia Sequence 1 Protein/genetics*
;
Humans
;
Proto-Oncogene Proteins c-myc/genetics*
;
Cell Proliferation
;
Signal Transduction
;
Neoplasms/pathology*
;
F-Box-WD Repeat-Containing Protein 7/genetics*
;
Cell Survival
;
Cell Line, Tumor
;
Apoptosis
7.Development of a smartphone-integrated handheld automated biochemical analyzer for point-of-care testing of urinary albumin.
Ze WU ; Peng ZHANG ; Wei XIAO ; Qian CHEN ; Wangrun LIN ; Peipei CHEN ; Kangwei CHEN ; Qiangqiang FU ; Zhijian WANG ; Lei ZHENG
Journal of Pharmaceutical Analysis 2025;15(3):101041-101041
The level of urinary albumin is a critical indicator for the early diagnosis and management of chronic kidney disease (CKD). However, existing methods for detecting albumin are not conducive to point-of-care testing due to the complexity of reagent addition and incubation processes. This study presents a smartphone-integrated handheld automated biochemical analyzer (sHABA) designed for point-of-care testing of urinary albumin. The sHABA features a pre-loaded, disposable reagent cassette with reagents for the albumin assay arranged in the order of their addition within a hose. The smartphone-integrated analyzer can drive the reagents following a preset program, to enable automatic sequential addition. The sHABA has a detection limit for albumin of 5.9 mg/L and a linear detection range from 7 to 450 mg/L. The consistency of albumin level detection in 931 urine samples using sHABA with clinical tests indicates good sensitivity (95.78%) and specificity (90.16%). This research advances the field by providing an automated detection method for albumin in a portable device, allowing even untrained individuals to monitor CKD in real time at the patient's bedside. In the context of promoting tiered diagnosis and treatment, the sHABA has the potential to become an essential tool for the early diagnosis and comprehensive management of CKD and other chronic conditions.
8.Comparison of short-term clinical efficacy between CO external fixation and internal fixation with steel plate in the treatment of unstable distal radius fractures.
Min-Rui FU ; Chang-Long SHI ; Yong-Zhong CHENG ; Ming-Ming MA ; Zheng-Lin NIU ; Hai-Xiang SUN ; Jing-Hua GAO ; Zhong-Kai WU ; Yi-Ming XU
China Journal of Orthopaedics and Traumatology 2025;38(1):10-17
OBJECTIVE:
To evaluate the short-term clinical efficacy of external fixation and internal fixation with steel plate in the treatment of unstable distal radius fractures (AO-23C type), based on the principles of Chinese osteosynthesis (CO).
METHODS:
Forty-eight patients with unstable distal radius fractures between January 2022 and February 2023 were retrospectively analyzed and divided into the CO external fixation group and internal fixation group. CO external fixation group consisted of 25 patients, including 7 males and 18 females, aged from 37 to 56 years old with an average of ( 52.6±11.3) years old. Among them, there were 7 patients of traffic accidents and 18 patients of falls, resulting in a total of 25 patients of closed fractures and no open fractures, the treatment was conducted using closed reduction and CO external fixation. The internal fixation group consisted of 23 patients, comprising 8 males and 15 females, age ranged from 41 to 59 years old, with an average age of(53.3±13.7) years old. Among them, 8 patients resulted from car accidents while the remaining 15 patients were caused by falls. All 23 patients were closed fractures without any open fractures observed. The technique of open reduction and internal fixation with steel plate was employed. The perioperative data, including injury-operation time, operation duration, blood loss, and length of hospital stay, were assessed in both groups. Additionally, the QuickDASH score and visual analogue scale (VAS) were evaluated. Range of motion and grip strength assessment, imaging findings such as palmar inclination angle, ulnar declination angle, radius length, articular surface step, intra-articular space measurements were also examined along with any complications.
RESULTS:
The follow-up duration ranged from 0 to 24 months, with an average duration of (16.0±3.8) months. The CO external fixation exhibited significantly shorter time from injury to operation (2.4±3.3) d vs (7.4±3.7) d, shorter operation duration (56.27±15.23) min vs (74.10±5.26) min, lower blood loss (14.52±6.54) ml vs (32.32±10.03) ml, and reduced hospitalization days (14.04±3.24 )d vs (16.45±3.05) d compared to the internal fixation group (P<0.05). The QuickDASH score at 12 months post-operation was (8.21±1.64) in the CO external fixation group, while no significant difference was observed in the internal fixation group (7.04±3.64), P>0.05. There were no statistically significant differences in VAS between two groups at 6 weeks, as well as 1 and 3 months post-surgery (P>0.05). Additionally, there were no significant disparities observed in terms of range of motion and grip strength between two groups at the 2-year follow-up after the operation (P>0.05). After 12 months of surgery, the CO external fixation group exhibited a significantly smaller palmar inclination angle (17.90±2.18) ° vs (19.87±3.21) °, reduced articular surface step (0.11±0.03) mm vs (0.17±0.02) mm, and shorter radius length (8.16±1.11) mm compared to the internal fixation group (9.59±1.02) mm, P<0.05. The ulnar deviation angle and intra-articular space did not show any significant difference between two groups (P>0.05). The reduced fell within the allowable range between the CO external fixation group (23 out of 25 cases) and the internal fixation group (21 out of 23 cases) was not statistically significant (P=0.29). There was no significant difference in complications between the two groups(P>0.05).
CONCLUSION
Both the CO external fixation and open reduction with plate internal fixation demonstrate clinical efficacy in managing unstable distal radius fractures. The CO external fixation offers advantages in shorter injury-to-operation times, reduced intraoperative blood loss, and decreased surgical durations, while radial shortening is more effectively controlled by internal fixation.
Humans
;
Male
;
Female
;
Middle Aged
;
Radius Fractures/physiopathology*
;
Adult
;
Bone Plates
;
Fracture Fixation, Internal/methods*
;
External Fixators
;
Retrospective Studies
;
Fracture Fixation/methods*
;
Wrist Fractures
9.Delayed covering causes the accumulation of motile sperm, leading to overestimation of sperm concentration and motility with a Makler counting chamber.
Lin YU ; Qing-Yuan CHENG ; Ye-Lin JIA ; Yan ZHENG ; Ting-Ting YANG ; Ying-Bi WU ; Fu-Ping LI
Asian Journal of Andrology 2025;27(1):59-64
According to the World Health Organization (WHO) manual, sperm concentration should be measured using an improved Neubauer hemocytometer, while sperm motility should be measured by manual assessment. However, in China, thousands of laboratories do not use the improved Neubauer hemocytometer or method; instead, the Makler counting chamber is one of the most widely used chambers. To study sources of error that could impact the measurement of the apparent concentration and motility of sperm using the Makler counting chamber and to verify its accuracy for clinical application, 67 semen samples from patients attending the Department of Andrology, West China Second University Hospital, Sichuan University (Chengdu, China) between 13 September 2023 and 27 September 2023, were included. Compared with applying the cover glass immediately, delaying the application of the cover glass for 5 s, 10 s, and 30 s resulted in average increases in the sperm concentration of 30.3%, 74.1%, and 107.5%, respectively (all P < 0.0001) and in the progressive motility (PR) of 17.7%, 30.8%, and 39.6%, respectively (all P < 0.0001). However, when the semen specimens were fixed with formaldehyde, a delay in the application of the cover glass for 5 s, 10 s, and 30 s resulted in an average increase in the sperm concentration of 6.7%, 10.8%, and 14.6%, respectively, compared with immediate application of the cover glass. The accumulation of motile sperm due to delays in the application of the cover glass is a significant source of error with the Makler counting chamber and should be avoided.
Humans
;
Male
;
Sperm Motility/physiology*
;
Sperm Count
;
Semen Analysis/methods*
;
Spermatozoa/physiology*
;
Time Factors


Result Analysis
Print
Save
E-mail