1.From Bedside to Molecular Diagnosis-Multidisciplinary Treatment of a Rare Case of Autoinflammatory Disease Presenting with Skin Induration and Limb Weakness
Hanhui FU ; Wenjun WANG ; Yaping LIU ; Hui YOU ; Tao WANG ; Wen ZHANG ; Xuejun ZENG ; Liying CUI ; Huijuan ZHU ; Xiuli ZHAO ; Min SHEN ; Yicheng ZHU
JOURNAL OF RARE DISEASES 2026;5(2):207-213
This article reports a rare case of autoinflammatory disease presenting initially with skin induration and swelling after trauma as the initial manifestation, followed by progressive limb weakness. The patient was a middle-aged female who developed skin induration and swelling after trauma, which gradually progressed to limb weakness, dysarthria and bilateral facial paralysis, accompanied by livedo reticularis of the lower extremities, diffuse skin induration of the limbs, and beaded subcutaneous nodules in the right upper limb. The patient had a susceptibility to infection since childhood and a history of chronic livedo reticularis. Skin pathological examination revealed panniculitis. A comprehensive etiological screening for special infections and autoimmune diseases was completed with an unremarkable results, and whole-exome sequencing showed no abnormal findings. Following a multidisciplinary discussion combined with RNA sequencing results, the patient was diagnosed with an autoinflammatory disease, with a suspected type Ⅰ interferonopathy. Treatment with tofacitinib resulted in gradual improvement of clinical symptoms. This case highlights the importance of detailed medical history collection, systematic physical examination and multidisciplinary collaborative diagnosis and treatment, and underscores the pivotal role of molecular diagnosis in the confirmation of rare diseases. It can provide a reference for the clinical diagnosis and management of similar rare cases.
2.Differences in deltamethrin resistance and kdr gene mutation in Culex tritaeniorhynchus population in and outside the Yellow Sea wetland
Xiao-er ZHANG ; Zhi-ming WU ; Ye TIAN ; Qian CUI ; Yu-qian JI ; Huan WANG ; Shu-juan YANG ; Yi-chao ZHAO ; Yu WANG ; Hua-yu YIN ; Yu DING ; Guo-jin YAN ; Min-sen ZHAO ; Shou-gang ZHANG ; Bing-dong SONG ; Hong-na CHEN ; Jian GAO ; Wei-fang YANG ; Yu-fu ZHANG ; Hui LIU ; Hong-liang CHU
Acta Parasitologica et Medica Entomologica Sinica 2026;33(2):101-107
Objective To gain insights into the biological characteristics of different populations of Culex tritaeniorhynchus within and around the Yellow Sea wetland from the perspective of the occurrence of resistance, we investigated the levels of resistance to deltamethrin and kdr gene mutation in the wetland and its peripheral areas. Methods Specimens were collected from Cx. tritaeniorhynchus populations at two monitoring sites in the Rare Bird National Nature Reserve and Tiaozi Ni Wetland Scenic Area, and also from two populations in Yancheng City and the Liuhe District of Nanjing, and the resistance of these mosquitoes to deltamethrin was determined using the CDC biotest bottle method. For each concentration of deltamethrin assessed, a random subset of exposed specimens was selected for amplification of the kdr gene fragment, followed by Sanger sequencing to identify and analyze resistance-associated mutations. Results The LC50 levels of deltamethrin among mosquitoes from the four populations in Luhe, Yancheng, the Rare Bird National Nature Reserve and the Tiaozi Ni Wetland Scenic Area were 2.048 5, 7.798 2, 3.473 3, and 17.695 5 mg/mL, respectively, with corresponding concentrations of deltamethrin ranging from 0.005 to 5.000,0.050 to 50.000,0.050 to 25.000 and 0.050 to 50.000 mg/mL, respectively. Furthermore, the ranges of the KT50 values were 11.76-107.43, 67.05-216.30,29.77-107.43 and 28.40-329.51 min; the 1-h knockdown rates were 34.58%-99.15%, 9.52%-43.80%, 55.09%-73.01%, and 10.09%-68.07%; and the 24-h mortality rates were 12.15%-67.52%,9.52%-79.56%,13.17%-82.21%, and 11.01%-78.99%, respectively. With respect to kdr gene mutation, we assayed a total of 63,70,59, and 57 mosquitoes for the four populations, for which we detected L1014F mutation frequencies of 14.29%, 35.00%, 20.34%, and 31.58%, respectively, with a majority of these mutations being heterozygous for resistance. In addition, five adult mosquitoes were identified has having synonymous mutations at site 1011[i. e. , AAT(asparagine)mutation to AAC(asparagine)]. Conclusions Our findings revealed the clear resistance of Cx. tritaeniorhynchus to deltamethrin in the Yancheng region of the Yellow Sea wetland, and the resistance phenotype and kdr frequency of Cx. tritaeniorhynchus in the wetland environment were comparable to those of Cx. tritaeniorhynchus in the wetland environment, thereby indicating that the resistance of different populations of Cx. tritaeniorhynchus was homogeneous under the pressure of different insecticide selection within and around the wetland. However, the underlying mechanisms need to be further studied.
3.Application of artificial intelligence in quality control of mammographic images
Yunyun LYU ; Le FU ; Ruixin LI ; Zeyi ZHANG ; Xiaoli MU ; Hui WANG ; Huizhi CAO ; Jianli YU
Chinese Journal of Radiological Health 2026;35(2):173-179
Objective To evaluate the application value of artificial intelligence (AI) in the quality control of mammographic images and explore its feasibility for improving image quality. Methods A retrospective analysis was conducted on 500 mammographic images from 125 female patients. These images were acquired in December 2024 at the Department of Radiology, Obstetrics and Gynecology Hospital of Tongji University by two junior technologists with qualification certificate for junior radiologic technologists and ≤ 2 months of independent operation. The reference standard was the evaluation by a panel of senior experts comprising one associate chief radiologist and two intermediate radiologic technologists with over 10 years of experience in mammography. The evaluation was based on nine criteria within an AI quality control system. The correlation and consistency (Kappa test) of the assessment outcomes were compared among the junior technologist group, the AI quality control group, and the panel group. Additionally, the differences in the proportions of high-, medium-, and low-quality images rated by the three groups were analyzed. After one month of AI assistance, 200 images from 50 additional patients acquired by the same two junior technologists in January 2025 were collected. The area under the receiver operating characteristic curve and 95% confidence interval (95%CI) were calculated for the assessment performance of the junior technologist group before and after AI assistance. Differences were compared using the DeLong test. Changes in the disqualification rates for the nine criteria were analyzed. Results In consistency analysis, the AI quality control group showed high consistency with the panel group across multiple key criteria, with Kappa values ranging from 0.41 to 1.00. In contrast, the consistency between the junior technologist group and the panel group was generally low, with Kappa values ranging from 0.13 to 0.49. In comparison of image quality classification, no significant differences were observed in image quality classification between the AI group and the panel group (P>0.05). However, the proportion of images rated as high quality by the junior technologist group was significantly higher, while the proportions rated as medium and low quality were significantly lower, compared to those rated by the panel group (P<0.05). After AI assistance, the area under the receiver operating characteristic curve for the assessment performance of junior technologist group increased significantly from 0.56 (95%CI: 0.51-0.61) to 0.91 (95%CI: 0.87-0.94) (P<0.001). The disqualification rates for skin folds, incomplete inclusion of the pectoralis major muscle, and nipple not in profile decreased significantly. Conclusion AI demonstrates assessment capability comparable to the panel group in mammographic quality control. AI effectively enhances the quality of images acquired by junior technologists through real-time, objective feedback.
4.Application of artificial intelligence in quality control of mammographic images
Yunyun LYU ; Le FU ; Ruixin LI ; Zeyi ZHANG ; Xiaoli MU ; Hui WANG ; Huizhi CAO ; Jianli YU
Chinese Journal of Radiological Health 2026;35(2):173-179
Objective To evaluate the application value of artificial intelligence (AI) in the quality control of mammographic images and explore its feasibility for improving image quality. Methods A retrospective analysis was conducted on 500 mammographic images from 125 female patients. These images were acquired in December 2024 at the Department of Radiology, Obstetrics and Gynecology Hospital of Tongji University by two junior technologists with qualification certificate for junior radiologic technologists and ≤ 2 months of independent operation. The reference standard was the evaluation by a panel of senior experts comprising one associate chief radiologist and two intermediate radiologic technologists with over 10 years of experience in mammography. The evaluation was based on nine criteria within an AI quality control system. The correlation and consistency (Kappa test) of the assessment outcomes were compared among the junior technologist group, the AI quality control group, and the panel group. Additionally, the differences in the proportions of high-, medium-, and low-quality images rated by the three groups were analyzed. After one month of AI assistance, 200 images from 50 additional patients acquired by the same two junior technologists in January 2025 were collected. The area under the receiver operating characteristic curve and 95% confidence interval (95%CI) were calculated for the assessment performance of the junior technologist group before and after AI assistance. Differences were compared using the DeLong test. Changes in the disqualification rates for the nine criteria were analyzed. Results In consistency analysis, the AI quality control group showed high consistency with the panel group across multiple key criteria, with Kappa values ranging from 0.41 to 1.00. In contrast, the consistency between the junior technologist group and the panel group was generally low, with Kappa values ranging from 0.13 to 0.49. In comparison of image quality classification, no significant differences were observed in image quality classification between the AI group and the panel group (P>0.05). However, the proportion of images rated as high quality by the junior technologist group was significantly higher, while the proportions rated as medium and low quality were significantly lower, compared to those rated by the panel group (P<0.05). After AI assistance, the area under the receiver operating characteristic curve for the assessment performance of junior technologist group increased significantly from 0.56 (95%CI: 0.51-0.61) to 0.91 (95%CI: 0.87-0.94) (P<0.001). The disqualification rates for skin folds, incomplete inclusion of the pectoralis major muscle, and nipple not in profile decreased significantly. Conclusion AI demonstrates assessment capability comparable to the panel group in mammographic quality control. AI effectively enhances the quality of images acquired by junior technologists through real-time, objective feedback.
5.Application of artificial intelligence in quality control of mammographic images
Yunyun LYU ; Le FU ; Ruixin LI ; Zeyi ZHANG ; Xiaoli MU ; Hui WANG ; Huizhi CAO ; Jianli YU
Chinese Journal of Radiological Health 2026;35(2):173-179
Objective To evaluate the application value of artificial intelligence (AI) in the quality control of mammographic images and explore its feasibility for improving image quality. Methods A retrospective analysis was conducted on 500 mammographic images from 125 female patients. These images were acquired in December 2024 at the Department of Radiology, Obstetrics and Gynecology Hospital of Tongji University by two junior technologists with qualification certificate for junior radiologic technologists and ≤ 2 months of independent operation. The reference standard was the evaluation by a panel of senior experts comprising one associate chief radiologist and two intermediate radiologic technologists with over 10 years of experience in mammography. The evaluation was based on nine criteria within an AI quality control system. The correlation and consistency (Kappa test) of the assessment outcomes were compared among the junior technologist group, the AI quality control group, and the panel group. Additionally, the differences in the proportions of high-, medium-, and low-quality images rated by the three groups were analyzed. After one month of AI assistance, 200 images from 50 additional patients acquired by the same two junior technologists in January 2025 were collected. The area under the receiver operating characteristic curve and 95% confidence interval (95%CI) were calculated for the assessment performance of the junior technologist group before and after AI assistance. Differences were compared using the DeLong test. Changes in the disqualification rates for the nine criteria were analyzed. Results In consistency analysis, the AI quality control group showed high consistency with the panel group across multiple key criteria, with Kappa values ranging from 0.41 to 1.00. In contrast, the consistency between the junior technologist group and the panel group was generally low, with Kappa values ranging from 0.13 to 0.49. In comparison of image quality classification, no significant differences were observed in image quality classification between the AI group and the panel group (P>0.05). However, the proportion of images rated as high quality by the junior technologist group was significantly higher, while the proportions rated as medium and low quality were significantly lower, compared to those rated by the panel group (P<0.05). After AI assistance, the area under the receiver operating characteristic curve for the assessment performance of junior technologist group increased significantly from 0.56 (95%CI: 0.51-0.61) to 0.91 (95%CI: 0.87-0.94) (P<0.001). The disqualification rates for skin folds, incomplete inclusion of the pectoralis major muscle, and nipple not in profile decreased significantly. Conclusion AI demonstrates assessment capability comparable to the panel group in mammographic quality control. AI effectively enhances the quality of images acquired by junior technologists through real-time, objective feedback.
6.Chinese expert consensus on the clinical application of recombinant human thyroid-stimulating hormone (2025 edition)
Chentian SHEN ; Yushen GU ; Hui TAN ; Anren KUANG ; Sijin LI ; Yaming LI ; Jing WANG ; Ningyi JIANG ; Jian TAN ; Zhuoying WANG ; Shaoyan LIU ; Xiaoyi LI ; Jugao FANG ; Dingcun LUO ; Youben FAN ; Hui WANG ; Yuetao WANG ; Xuemei WANG ; Feng WANG ; Wei FU ; Feng SHI ; Xuegong LIU ; Zhongwei LÜ ; Yan XING ; Lin LI ; Hui YANG ; Jun XIN ; Yifan ZHANG ; Yue CHEN ; Yansong LIN ; Wei OUYANG ; Shuzhan YAO ; Changjiu ZHAO ; Xinming ZHAO ; Zairong GAO ; Dingde HUANG ; Qiang WEN ; Xingmin HAN ; Cen LOU ; Weibing MIAO ; Wei FAN ; Quanyong LUO ; Hongcheng SHI
Chinese Journal of Clinical Medicine 2026;33(5):932-944
The recombinant human thyroid-stimulating hormone (rhTSH) can be used for differentiated thyroid cancer (DTC) preparation before 131I therapy, and follow-up. Since its approval by the American Food and Drug Administration (FDA) in 1998, rhTSH has been clinically used in European countries, the United States, and other countries for nearly 30 years. In April 2024, China’s first independently developed rhTSH agent was approved. Based on clinical experience and evidence from domestic and international studies, an expert consensus on the application of rhTSH has been developed following thorough consultations among experts. The consensus offers evidence-based recommendations to guide the appropriate use of rhTSH in clinical practice.
7.The immunomodulatory effect of berbamine on mice with systemic lupus erythematosus.
Hui-Lian WANG ; Jun-Ping ZHAN ; Xi-Yun MIAO ; Qing-Liang MENG ; Jun-Fu MA
Acta Physiologica Sinica 2025;77(3):432-440
Systemic lupus erythematosus (SLE) is an autoimmune disease accompanied by various complications, and the exact etiology remains unclear. Treatments for SLE encompass hormone therapy, plasma exchange and immunoadsorption, and targeted biological therapies. Berbamine (BBM), a cellular immunopotentiator with diverse biological functions, has not been reported to have immunomodulatory and therapeutic effects on SLE. The mice were divided into control group, model group, positive control group, low, medium and high BBM groups. In control group, C57BL/6J wild mice received intraperitoneal injection of saline. In model group, MRL/lpr lupus mice were treated with intraperitoneal injection of saline. In positive control group, MRL/lpr lupus mice received intragastric administration of hydroxychloroquine sulfate tablets [Plaquenil, 150 mg/(kg·d)]. In BBM groups, MRL/lpr lupus mice received intragastric administration of different concentration of BBM respectively [20 mg/(kg·d), 50 mg/(kg·d), 100 mg/(kg·d)]. After 8 weeks of treatment, blood was collected from the retro-orbital venous plexus, and ELISA was used to detect the levels of anti-double-stranded DNA (dsDNA) antibodies, antinuclear antibodies (ANA), and anti-small nuclear ribonucleoprotein/Sm (snRNP/Sm) antibodies. Spleen tissues were collected for analysis of Th1/Th2 ratio by flow cytometry. The RNA and protein of spleen were extracted, and the levels of T-box transcription factor T-bet and GATA3 (GATA binding protein 3) mRNA and protein were detected by qRT-PCR and Western blot. The proliferation of white blood cells in the blood was tested by blood routine test. The histopathological changes of kidneys of each group were detected by HE staining. Compared with the model group, the levels of ANA, anti-dsDNA, and anti-snRNP/Sm antibodies were significantly reduced in the BBM-treated groups. The Th1/Th2 ratio was significantly decreased in the model group, but reversed by BBM. Compared with the control group, T-bet expression was significantly downregulated, while GATA3 expression was significantly upregulated in the model group. After BBM intervention, T-bet expression significantly increased, while GATA3 expression decreased compared with the model group. The number of white blood cells significantly decreased in the model group, and increased in the BBM-treated groups. In the model group, the glomerular mesangial and endothelial cells showed significant hyperplasia, clear thrombus was observed in the dilated capillaries, and inflammatory cells infiltrated in the renal interstitium. In medium and high BBM groups, the infiltration of inflammatory cells and capillary thrombosis were significantly decreased. In conclusion, BBM exhibits certain immunomodulatory effects on SLE and promotes the proliferation of white blood cells.
Animals
;
Lupus Erythematosus, Systemic/immunology*
;
Mice
;
Mice, Inbred C57BL
;
Mice, Inbred MRL lpr
;
Female
;
Benzylisoquinolines/pharmacology*
8.Comparison on odor components before and after processing of Cervi Cornu Pantotrichum based on electronic nose, HS-GC-MS, and odor activity value.
Xiao-Yu YAO ; Ke SHEN ; Di WU ; Xiao-Fei SUN ; Chun-Qin MAO ; Li FU ; Xiao-Yan WANG ; Hui XIE ; Tu-Lin LU
China Journal of Chinese Materia Medica 2025;50(2):421-431
Processing for deodorization is widely used in the production of animal-derived Chinese medicinal materials. In this study, Heracles Neo ultra-fast gas-phase electronic nose combined with chemometrics was employed to analyze the overall odor difference of Cervi Cornu Pantotrichum(focusing on that derived from Cervus nippon Temminck in this study) before and after processing. The results showed that the electronic nose effectively distinguished between the medicinal materials and decoction pieces of Cervi Cornu Pantotrichum. HS-GC-MS was used to identify and quantify the volatile components in the medicinal materials and decoction pieces of Cervi Cornu Pantotrichum, and 35 and 37 volatile components were detected in the medicinal materials and decoction pieces, respectively. The medicinal materials and decoction pieces contained 28 common volatile components contributing to the odor of Cervi Cornu Pantotrichum. The odor activity value(OAV) of each volatile component was calculated based on the olfactory threshold and relative content. The results showed that there were 17 key odor substances such as isovaleraldehyde, 2-methylbutanal, isobutyraldehyde, hexanal, and methanethiol in the medicinal materials and decoction pieces of Cervi Cornu Pantotrichum. All of them had bad odor and were the main source of the odor of Cervi Cornu Pantotrichum. The results of principal component analysis(PCA) and orthogonal partial least squares-discriminant analysis(OPLS-DA) showed that there were significant differences in volatile components between the medicinal materials and decoction pieces of Cervi Cornu Pantotrichum. Based on the thresholds of P<0.05 and Variable Importance in Projection(VIP)>1, 21 differential volatile odor components were screened out. Among them, isopentanol, isovaleraldehyde, 2-methylbutanal, n-nonanal, and dimethylamine were the key differential odor compounds between the medicinal materials and decoction pieces of Cervi Cornu Pantotrichum. The odor compounds and their relative content reduced, and some flavor substances such as esters were produced after processing with wine, which was the main reason for the reduction of the odor after processing of Cervi Cornu Pantotrichum.
Odorants/analysis*
;
Electronic Nose
;
Gas Chromatography-Mass Spectrometry/methods*
;
Animals
;
Volatile Organic Compounds/analysis*
;
Deer
;
Drugs, Chinese Herbal/chemistry*
9.Longitudinal Associations between Vitamin D Status and Systemic Inflammation Markers among Early Adolescents.
Ting TANG ; Xin Hui WANG ; Xue WEN ; Min LI ; Meng Yuan YUAN ; Yong Han LI ; Xiao Qin ZHONG ; Fang Biao TAO ; Pu Yu SU ; Xi Hua YU ; Geng Fu WANG
Biomedical and Environmental Sciences 2025;38(1):94-99
10.Effects of Hot Night Exposure on Human Semen Quality: A Multicenter Population-Based Study.
Ting Ting DAI ; Ting XU ; Qi Ling WANG ; Hao Bo NI ; Chun Ying SONG ; Yu Shan LI ; Fu Ping LI ; Tian Qing MENG ; Hui Qiang SHENG ; Ling Xi WANG ; Xiao Yan CAI ; Li Na XIAO ; Xiao Lin YU ; Qing Hui ZENG ; Pi GUO ; Xin Zong ZHANG
Biomedical and Environmental Sciences 2025;38(2):178-193
OBJECTIVE:
To explore and quantify the association of hot night exposure during the sperm development period (0-90 lag days) with semen quality.
METHODS:
A total of 6,640 male sperm donors from 6 human sperm banks in China during 2014-2020 were recruited in this multicenter study. Two indices (i.e., hot night excess [HNE] and hot night duration [HND]) were used to estimate the heat intensity and duration during nighttime. Linear mixed models were used to examine the association between hot nights and semen quality parameters.
RESULTS:
The exposure-response relationship revealed that HNE and HND during 0-90 days before semen collection had a significantly inverse association with sperm motility. Specifically, a 1 °C increase in HNE was associated with decreased sperm progressive motility of 0.0090 (95% confidence interval [ CI]: -0.0147, -0.0033) and decreased total motility of 0.0094 (95% CI: -0.0160, -0.0029). HND was significantly associated with reduced sperm progressive motility and total motility of 0.0021 (95% CI: -0.0040, -0.0003) and 0.0023 (95% CI: -0.0043, -0.0002), respectively. Consistent results were observed at different temperature thresholds on hot nights.
CONCLUSION
Our findings highlight the need to mitigate nocturnal heat exposure during spermatogenesis to maintain optimal semen quality.
Humans
;
Male
;
Semen Analysis
;
Adult
;
Sperm Motility
;
Hot Temperature/adverse effects*
;
China
;
Middle Aged
;
Spermatozoa/physiology*
;
Young Adult


Result Analysis
Print
Save
E-mail