1.Differences in deltamethrin resistance and kdr gene mutation in Culex tritaeniorhynchus population in and outside the Yellow Sea wetland
Xiao-er ZHANG ; Zhi-ming WU ; Ye TIAN ; Qian CUI ; Yu-qian JI ; Huan WANG ; Shu-juan YANG ; Yi-chao ZHAO ; Yu WANG ; Hua-yu YIN ; Yu DING ; Guo-jin YAN ; Min-sen ZHAO ; Shou-gang ZHANG ; Bing-dong SONG ; Hong-na CHEN ; Jian GAO ; Wei-fang YANG ; Yu-fu ZHANG ; Hui LIU ; Hong-liang CHU
Acta Parasitologica et Medica Entomologica Sinica 2026;33(2):101-107
Objective To gain insights into the biological characteristics of different populations of Culex tritaeniorhynchus within and around the Yellow Sea wetland from the perspective of the occurrence of resistance, we investigated the levels of resistance to deltamethrin and kdr gene mutation in the wetland and its peripheral areas. Methods Specimens were collected from Cx. tritaeniorhynchus populations at two monitoring sites in the Rare Bird National Nature Reserve and Tiaozi Ni Wetland Scenic Area, and also from two populations in Yancheng City and the Liuhe District of Nanjing, and the resistance of these mosquitoes to deltamethrin was determined using the CDC biotest bottle method. For each concentration of deltamethrin assessed, a random subset of exposed specimens was selected for amplification of the kdr gene fragment, followed by Sanger sequencing to identify and analyze resistance-associated mutations. Results The LC50 levels of deltamethrin among mosquitoes from the four populations in Luhe, Yancheng, the Rare Bird National Nature Reserve and the Tiaozi Ni Wetland Scenic Area were 2.048 5, 7.798 2, 3.473 3, and 17.695 5 mg/mL, respectively, with corresponding concentrations of deltamethrin ranging from 0.005 to 5.000,0.050 to 50.000,0.050 to 25.000 and 0.050 to 50.000 mg/mL, respectively. Furthermore, the ranges of the KT50 values were 11.76-107.43, 67.05-216.30,29.77-107.43 and 28.40-329.51 min; the 1-h knockdown rates were 34.58%-99.15%, 9.52%-43.80%, 55.09%-73.01%, and 10.09%-68.07%; and the 24-h mortality rates were 12.15%-67.52%,9.52%-79.56%,13.17%-82.21%, and 11.01%-78.99%, respectively. With respect to kdr gene mutation, we assayed a total of 63,70,59, and 57 mosquitoes for the four populations, for which we detected L1014F mutation frequencies of 14.29%, 35.00%, 20.34%, and 31.58%, respectively, with a majority of these mutations being heterozygous for resistance. In addition, five adult mosquitoes were identified has having synonymous mutations at site 1011[i. e. , AAT(asparagine)mutation to AAC(asparagine)]. Conclusions Our findings revealed the clear resistance of Cx. tritaeniorhynchus to deltamethrin in the Yancheng region of the Yellow Sea wetland, and the resistance phenotype and kdr frequency of Cx. tritaeniorhynchus in the wetland environment were comparable to those of Cx. tritaeniorhynchus in the wetland environment, thereby indicating that the resistance of different populations of Cx. tritaeniorhynchus was homogeneous under the pressure of different insecticide selection within and around the wetland. However, the underlying mechanisms need to be further studied.
2.Development of A Low Field Ion Extraction System for Time-of-Flight Secondary Ion Mass Spectrometry
De-Ze WANG ; Chen-Xin WU ; Yi CHEN ; Fu-Xin DU ; Lei HUA ; Hai-Yang LI ; Jian-Hua WANG ; Ping CHEN
Chinese Journal of Analytical Chemistry 2025;53(7):1072-1081
Time-of-flight secondary ion mass spectrometer(TOF-SIMS)is a highly sensitive surface analysis instrument with high spatial resolution.Traditional TOF-SIMS instruments for sample targets use high field extraction methods.Although the ion collection efficiency is high,it is prone to issues such as low-energy ion beam defocusing,sample morphology sensitivity,and organic molecule ion dissociation.This study aimed to develope an efficient low-field ion extraction system suitable for TOF-SIMS with a continuous beam source.The SIMION simulation software was used to construct a model of the secondary ion optical extraction system.The key factors affecting the extraction efficiency were studied,and the structural parameters of the extraction cone were optimized.Using an indium target as the sample,an experimental test of the performance of the ion extraction system was carried out on the TOF-SIMS instrument.The influences of the voltages of the ion extraction cone and the single lens on the ion extraction efficiency were consistent with the simulation results.By adopting the technology of deflection and coaxial dynamic compensation,the imaging field of view of the ion extraction system was increased to 500 μm×500 μm.The energy window of the ion extraction system reached 10 eV,and the large imaging depth of field of 400 μm was achieved.In the test of a 5 mg/L cholesterol thin film sample,the signal-to-noise ratio of the characteristic peak[M-OH]+reached 4453.The results showed that this low-field secondary ion extraction system effectively improved the performance of the continuous beam TOF-SIMS instrument.
3.Guideline for diagnosis and treatment of infection after internal fixation of closed lower limb fractures in adults (version 2025)
Bobin MI ; Faqi CAO ; Weixian HU ; Wu ZHOU ; Chenchen YAN ; Hui LI ; Yun SUN ; Yuan XIONG ; Jinmi ZHAO ; Qikai HUA ; Xinbao WU ; Xieyuan JIANG ; Dianying ZHANG ; Zhongguo FU ; Dankai WU ; Guangyao LIU ; Guodong LIU ; Tengbo YU ; Jinhai TAN ; Xi CHEN ; Fengfei LIN ; Zhangyuan LIN ; Dongfa LIAO ; Aiguo WANG ; Shiwu DONG ; Gaoxing LUO ; Zhao XIE ; Dong SUN ; Dehao FU ; Yunfeng CHEN ; Changqing ZHANG ; Kun LIU ; Deye SONG ; Yongjun RUI ; Fei WU ; Ximing LIU ; Junwen WANG ; Meng ZHAO ; Biao CHE ; Bing HU ; Chengjian HE ; Guanglin WANG ; Xiao CHEN ; Guandong DAI ; Shiyuan FANG ; Wenchao SONG ; Ming CHEN ; Guanghua GUO ; Yongqing XU ; Lei YANG ; Wenqian ZHANG ; Kun ZHANG ; Xin TANG ; Hua CHEN ; Weiguo XU ; Shuquan GUO ; Yong LIU ; Xiaodong GUO ; Zhewei YE ; Liming XIONG ; Tian XIA ; Hongbin WU ; Qisheng ZHOU ; Mengfei LIU ; Yiqiang HU ; Yanjiu HAN ; Hang XUE ; Kangkang ZHA ; Wei CHEN ; Zhiyong HOU ; Bin YU ; Jiacan SU ; Peifu TANG ; Baoguo JIANG ; Guohui LIU
Chinese Journal of Trauma 2025;41(5):421-432
Postoperative infection of internal fixation of closed fractures the lower limbs in adults represents a devastating complication, characterized by diagnostic challenges, prolonged treatment duration and high disability rates. Current management of these infections faces multiple challenges, such as difficulties in early accurate diagnosis, and various controversies about the treatment plan, leading to poor overall diagnosis and treatment results. To address these issues, based on evidence-based medicine and principles with emphasis on scientific rigor, clinical applicability and innovation, the Trauma Branch of the Chinese Medical Association, Orthopedic Branch of the Chinese Medical Doctor Association, Orthopedics Branch of the Chinese Medical Association, and Trauma Orthopedics and Polytrauma Group of the Resuscitation and Emergency Committee of the Chinese Medical Doctor Association have collaboratively organized a panel of relevant experts to develop the Guideline for diagnosis and treatment of infection after internal fixation of closed lower limb fractures in adults ( version 2025). The guideline proposed 10 recommendations, aiming to provide a foundation for standardized diagnosis and treatment of postoperative infection in adults with closed lower limb fractures.
4.Application and prospect of artificial intelligence in pharmacology research
Fu-xue KUANG ; Yu-jia SUN ; Zhi-hai QIU ; Hua-xun WU
Chinese Pharmacological Bulletin 2025;41(10):1830-1834
This review analyzes the application status and pros-pect of big data and artificial intelligence technology in the field of pharmacology in recent years.Big data and artificial intelli-gence technology is the inevitable result of the information age,which not only promotes the development of biomedicine,but al-so opens up new ways for the development of pharmacology.Mo-reover,artificial intelligence(AI)is a multifaceted and evolving field applied to pharmaceutical R&D,health management,and new drug R&D.Consequently,this review discusses the applica-tion of artificial intelligence in pharmacology at different stages,discusses the existing shortcomings,and finally makes an out-look.
5.Current situation of medicinal animal breeding and research progress in sustainable utilization of resources.
Cheng-Cai ZHANG ; Jia WANG ; Yu-Jie ZHOU ; Xiao-Yu DAI ; Xiu-Fu WAN ; Chuan-Zhi KANG ; De-Hua WU ; Jia-Hui SUN ; Sheng WANG ; Lan-Ping GUO
China Journal of Chinese Materia Medica 2025;50(16):4397-4406
Traditional Chinese medicine(TCM) is the pillar for the development of motherland medicine, and animal medicine has a long history of application in China, characterized by wide resources, strong activity, definite efficacy, and great benefits. It has significant potential and important status in the consumption market of raw materials of TCM. In the context of global climate change, farming system alterations, and low renewability, the depletion of wild medicinal animal resources has accelerated. Accordingly, the conservation and sustainable utilization of wild resources of animal medicinal materials has become a problem that garners increasing attention and urgently needs to be solved. This paper summarizes the current situation of domestic and foreign medicinal animal breeding and research progress in industrial application in recent years and points out the issues related to standardized breeding, germplasm selection and breeding, and quality evaluation standards for medicinal animals. Furthermore, this paper discusses standardized breeding, quality standards, resource protection and utilization, and the search for alternative resources for rare and endangered medicinal animals. It proposes that researchers should systematically carry out in-depth basic research on animal medicine, improve the breeding scale and level of medicinal animals, employ modern technology to enhance the quality standards of medicinal materials, and strengthen the research and development of alternative resources. This approach aims to effectively address the relationship between protection and utilization and make a significant contribution to the sustainable development of medicinal animal resources and the animal-based Chinese medicinal material industry.
Animals
;
Breeding
;
China
;
Medicine, Chinese Traditional
;
Conservation of Natural Resources
6.Comparison of short-term clinical efficacy between CO external fixation and internal fixation with steel plate in the treatment of unstable distal radius fractures.
Min-Rui FU ; Chang-Long SHI ; Yong-Zhong CHENG ; Ming-Ming MA ; Zheng-Lin NIU ; Hai-Xiang SUN ; Jing-Hua GAO ; Zhong-Kai WU ; Yi-Ming XU
China Journal of Orthopaedics and Traumatology 2025;38(1):10-17
OBJECTIVE:
To evaluate the short-term clinical efficacy of external fixation and internal fixation with steel plate in the treatment of unstable distal radius fractures (AO-23C type), based on the principles of Chinese osteosynthesis (CO).
METHODS:
Forty-eight patients with unstable distal radius fractures between January 2022 and February 2023 were retrospectively analyzed and divided into the CO external fixation group and internal fixation group. CO external fixation group consisted of 25 patients, including 7 males and 18 females, aged from 37 to 56 years old with an average of ( 52.6±11.3) years old. Among them, there were 7 patients of traffic accidents and 18 patients of falls, resulting in a total of 25 patients of closed fractures and no open fractures, the treatment was conducted using closed reduction and CO external fixation. The internal fixation group consisted of 23 patients, comprising 8 males and 15 females, age ranged from 41 to 59 years old, with an average age of(53.3±13.7) years old. Among them, 8 patients resulted from car accidents while the remaining 15 patients were caused by falls. All 23 patients were closed fractures without any open fractures observed. The technique of open reduction and internal fixation with steel plate was employed. The perioperative data, including injury-operation time, operation duration, blood loss, and length of hospital stay, were assessed in both groups. Additionally, the QuickDASH score and visual analogue scale (VAS) were evaluated. Range of motion and grip strength assessment, imaging findings such as palmar inclination angle, ulnar declination angle, radius length, articular surface step, intra-articular space measurements were also examined along with any complications.
RESULTS:
The follow-up duration ranged from 0 to 24 months, with an average duration of (16.0±3.8) months. The CO external fixation exhibited significantly shorter time from injury to operation (2.4±3.3) d vs (7.4±3.7) d, shorter operation duration (56.27±15.23) min vs (74.10±5.26) min, lower blood loss (14.52±6.54) ml vs (32.32±10.03) ml, and reduced hospitalization days (14.04±3.24 )d vs (16.45±3.05) d compared to the internal fixation group (P<0.05). The QuickDASH score at 12 months post-operation was (8.21±1.64) in the CO external fixation group, while no significant difference was observed in the internal fixation group (7.04±3.64), P>0.05. There were no statistically significant differences in VAS between two groups at 6 weeks, as well as 1 and 3 months post-surgery (P>0.05). Additionally, there were no significant disparities observed in terms of range of motion and grip strength between two groups at the 2-year follow-up after the operation (P>0.05). After 12 months of surgery, the CO external fixation group exhibited a significantly smaller palmar inclination angle (17.90±2.18) ° vs (19.87±3.21) °, reduced articular surface step (0.11±0.03) mm vs (0.17±0.02) mm, and shorter radius length (8.16±1.11) mm compared to the internal fixation group (9.59±1.02) mm, P<0.05. The ulnar deviation angle and intra-articular space did not show any significant difference between two groups (P>0.05). The reduced fell within the allowable range between the CO external fixation group (23 out of 25 cases) and the internal fixation group (21 out of 23 cases) was not statistically significant (P=0.29). There was no significant difference in complications between the two groups(P>0.05).
CONCLUSION
Both the CO external fixation and open reduction with plate internal fixation demonstrate clinical efficacy in managing unstable distal radius fractures. The CO external fixation offers advantages in shorter injury-to-operation times, reduced intraoperative blood loss, and decreased surgical durations, while radial shortening is more effectively controlled by internal fixation.
Humans
;
Male
;
Female
;
Middle Aged
;
Radius Fractures/physiopathology*
;
Adult
;
Bone Plates
;
Fracture Fixation, Internal/methods*
;
External Fixators
;
Retrospective Studies
;
Fracture Fixation/methods*
;
Wrist Fractures
7.Feasibility study of selective stentless management after ureteroscopic lithotripsy
Li JIANG ; Yue WU ; Hua HU ; Lian FU ; Chaoying LIU ; Chao MA ; Gang ZHOU ; Yunhan RAN ; Rui ZHU
Chongqing Medicine 2025;54(11):2616-2620
Objective To investigate the feasibility of selectively omitting ureteral stent placement after ureteroscopic lithotripsy(URL).Methods A total of 118 patients with distal ureteral calculi undergoing URL from 2021 to 2024 were enrolled.Patients were divided into a control group(indwelling ureteral stent for 2 weeks,n=86)and an observation group(no ureteral stent placement,n=32).General data,operation time,hospital stay,and total medical costs were compared between the two groups.Patients were followed 2 weeks postoperatively for assessment of flank pain visual analogue scale(VAS)scores,bladder irritation symptoms,hematuria,and incidence of urinary tract infection.Hydronephrosis was evaluated by ultrasonography 3 months after surgery.Results There was no significant difference in the general information and operation time between the two groups(P>0.05).The length of hospital stay and total treatment cost in the observa-tion group were significantly lower than those in the control group(P<0.05).Two weeks after surgery,the VAS scores of low back pain on the affected side and occurrence rates of bladder irritation symptoms,hematu-ria,and urinary tract infection in the observation group were significantly lower than those in the control group(P<0.01).Three months after operation,no hydronephrosis was observed in both groups.Conclusion It is safe and feasible to avoid indwelling ureteral stent after URL in appropriate cases.
8.Single-incision laparoscopic totally extraperitoneal retrieval of retroperitoneal vas deferens in vasovasostomy for obstructive azoospermia patients postchildhood bilateral herniorrhaphy.
Chen-Wang ZHANG ; Wei-Dong WU ; Jun-Wei XU ; Jing-Peng ZHAO ; Er-Lei ZHI ; Yu-Hua HUANG ; Chen-Cheng YAO ; Fu-Jun ZHAO ; Zheng LI ; Peng LI
Asian Journal of Andrology 2025;27(1):137-138
9.Correlation of IGF2 levels with sperm quality, inflammation, and DNA damage in infertile patients.
Jing-Gen WU ; Cai-Ping ZHOU ; Wei-Wei GUI ; Zhong-Yan LIANG ; Feng-Bin ZHANG ; Ying-Ge FU ; Rui LI ; Fang WU ; Xi-Hua LIN
Asian Journal of Andrology 2025;27(2):204-210
Insulin-like growth factor 2 (IGF2) is a critical endocrine mediator implicated in male reproductive physiology. To investigate the correlation between IGF2 protein levels and various aspects of male infertility, specifically focusing on sperm quality, inflammation, and DNA damage, a cohort of 320 male participants was recruited from the Women's Hospital, Zhejiang University School of Medicine (Hangzhou, China) between 1 st January 2024 and 1 st March 2024. The relationship between IGF2 protein concentrations and sperm parameters was assessed, and Spearman correlation and linear regression analysis were employed to evaluate the independent associations between IGF2 protein levels and risk factors for infertility. Enzyme-linked immunosorbent assay (ELISA) was used to measure IGF2 protein levels in seminal plasma, alongside markers of inflammation (tumor necrosis factor-alpha [TNF-α] and interleukin-1β [IL-1β]). The relationship between seminal plasma IGF2 protein levels and DNA damage marker phosphorylated histone H2AX (γ-H2AX) was also explored. Our findings reveal that IGF2 protein expression decreased notably in patients with asthenospermia and teratospermia. Correlation analysis revealed nuanced associations between IGF2 protein levels and specific sperm parameters, and low IGF2 protein concentrations correlated with increased inflammation and DNA damage in sperm. The observed correlations between IGF2 protein levels and specific sperm parameters, along with its connection to inflammation and DNA damage, underscore the importance of IGF2 in the broader context of male reproductive health. These findings lay the groundwork for future research and potential therapeutic interventions targeting IGF2-related pathways to enhance male fertility.
Humans
;
Male
;
Insulin-Like Growth Factor II/metabolism*
;
Infertility, Male/genetics*
;
DNA Damage
;
Adult
;
Inflammation/metabolism*
;
Spermatozoa/metabolism*
;
Semen Analysis
;
Semen/metabolism*
;
Tumor Necrosis Factor-alpha/metabolism*
;
Histones/metabolism*
;
Interleukin-1beta/metabolism*
10.Clinical application effects of the pedicled anterior intercostal artery perforator flap in breast reconstruction after breast-conserving surgery for breast cancer
Ansi YIN ; Bin WU ; Yi QUAN ; Hua FU ; Huaiquan ZUO ; Mingquan HUANG ; Yixian LI ; Jianzhe CHEN ; Dajiang SONG ; Zan LI ; Guangrui PAN
Chinese Journal of Burns 2025;41(7):680-687
Objective:To investigate the clinical application effects of the pedicled anterior intercostal artery perforator flap in breast reconstruction after breast-conserving surgery for breast cancer.Methods:This study was a retrospective observational study. From January to December 2023, 16 female breast cancer patients who met the inclusion criteria were hospitalized in the Department of Breast Surgery of the Affiliated Hospital of Southwest Medical University, with the age of (48±8) years. The pedicled anterior intercostal artery perforator flap was used for breast reconstruction of patients after breast-conserving surgery. After complete resection of tumor tissue, a "crescent-shaped" incision was designed at the inframammary fold. The pedicled anterior intercostal artery perforator flap was harvested based on the tumor location and the defect area after tumor removal. The flap was de-epithelialized, coapted, and rotated anterogradely or retrogradely to fill the defect. The donor site wound was closed with layered sutures. The following parameters were recorded: breast tissue loss volume during surgery, surgical duration, retention duration of the drainage tube, positive proportion of tumors in the breast incision margin tissue, breast loss ratio, flap survival, and incidence ratio of complications after operation. Patients were followed up for local recurrence or distant metastasis of tumor. At the last follow-up, the Ueda score was used to evaluate cosmetic outcomes of reconstructed breasts after breast-conserving surgery, and the Breast-Q scale version 2.0 was applied to assess patients' satisfaction and quality of life with breast reconstruction after breast-conserving surgery.Results:The breast tissue loss volume during surgery in this group of patients was 20-128 (59±34) cm3, the surgical duration was 105-200 (143±27) min, the retention duration of the drainage tube was 3-7 (4.6±1.0) d, and the positive proportion of tumors in the breast incision margin tissue was 1/16, with breast loss ratio of 0. After the surgery, the patient's transplanted flaps all survived. One patient had postoperative fat liquefaction in the surgical area, and the incidence ratio of postoperative complications was 1/16. The patients were followed up for 3-12 (11±4) months, and no local breast cancer recurrence or distant metastasis occurred. At the last follow-up, the cosmetic score of breast reconstruction after breast-conserving surgery were excellent in 6 cases, good in 8 cases, and fair in 2 cases, with an excellent and good ratio of 14/16. At the last follow-up, the highest score in the evaluation of patients' satisfaction with breast reconstruction and quality of life after breast-conserving surgery was the satisfaction with the surgeons, with a score of 59-100 (91±13), followed respectively by physiological health of the chest with a score of 60-100 (77±14), psychological health with a score of 35-100 (74±20), breast satisfaction with a score of 55-100 (73±13), satisfaction with information acquisition with a score of 53-100 (70±14), and sexual health with a score of 34-100 (70±23).Conclusions:The pedicled anterior intercostal artery perforator flap is safe and reliable for breast reconstruction after breast-conserving surgery for breast cancer, and can achieve high cosmetic effects and patient satisfaction. This flap is simple in design, easy to operate and highly reproducible, and is worthy of clinical promotion and application.


Result Analysis
Print
Save
E-mail