1.A case report of an adolescent with double parathyroid adenoma presenting with multiple bone lesions and fracture.
Philippine Journal of Surgical Specialties 2025;80(2):60-60
Primary hyperparathyroidism is characterized by increased secretion of parathyroid hormone, leading to hypercalcemia and skeletal and renal complications. In the past, it was diagnosed when presenting with classical signs and symptoms. Currently, the most common clinical presentation of PHPT is asymptomatic hypercalcemia, often detected by routine screening tests. Due to the changing presentations, the diagnosis can become challenging.
We present BA, a 16-year-old female with a 2-year history of multiple fractures, progressive lytic bone lesions and pain, and kidney stones. She was initially managed as a case of polyostotic fibrous dysplasia. The workup also revealed low levels of vitamin D, hypercalcemia, increased alkaline phosphatase, and elevated intact parathyroid hormones. A neck ultrasound revealed two solid masses posterior to the right thyroid lobe.
She underwent right parathyroidectomy, and a biopsy confirmed a double parathyroid adenoma.
This report also highlights the management of the case in a low-resource setting and the importance of timely diagnosis of primary hyperthyroidism to prevent a delay in the management, which could cause unnecessary pain, bone deformities, and disability.
Human ; Female ; Adolescent: 13-18 Yrs Old ; Parathyroid Hormone ; Parathyroid Neoplasms ; Parathyroidectomy ; Phosphoric Monoester Hydrolases ; Fractures, Multiple ; Hypercalcemia ; Hyperparathyroidism ; Hyperthyroidism
2.Biomechanical analysis of three kinds of rigid internal fixation methods for condylar head fractures.
Junhui SUN ; Duoduo LAN ; Dong WANG ; Yao XU ; Zeyu WANG ; Chenchen ZHANG ; Kai ZHANG ; Tao XU
West China Journal of Stomatology 2025;43(1):126-132
OBJECTIVES:
This study aims to analyze the biomechanics of three kinds of rigid internal fixation methods for condylar head fractures.
METHODS:
A three dimensional finite element model of the normal mandible was constructed. It was then used to prepare condylar head fracture finite element model and three kinds of rigid internal fixation finite element model (unilateral tension screw, bilateral tension screw, tension screw+titanium plate). The mechanical characteristics and changes of the mandible condyle under the same mechanical conditions were compared among the three different rigid internal fixation methods.
RESULTS:
The maximum equivalent stress and displacement of the non-free end of condyle under the rigid internal fixation method of unilateral tension screw were 71.03 MPa and 4.72 mm, respectively. The maximum equivalent stress and displacement of the free end of condyle were 78.45 MPa and 4.50 mm, respectively. The maximum stress of fracture suture was 3.27 MPa. The maximum equivalent stress and displacement of the non-free end of condyle under the rigid internal fixation method of bilateral tension screw were 70.52 MPa and 4.00 mm, respectively. The maximum equivalent stress and displacement of the free end of condyle were 72.49 MPa and 3.85 mm, respectively. The maximum stress of fracture suture was 2.33 MPa. The maximum equivalent stress and maximum displacement of the non-free end of condyle under the rigid internal fixation method of tension screw+titanium plate were 67.26 MPa and 2.66 mm, respectively. The maximum equivalent stress and maximum displacement of the free end of condyle were 69.66 MPa and 2.50 mm, respectively. The maximum stress of fracture suture was 2.18 MPa.
CONCLUSIONS
The tension screw+titanium plate rigid internal fixation method is the most conducive to biomechanical distribution for condylar head fractures.
Fracture Fixation, Internal/instrumentation*
;
Mandibular Condyle/surgery*
;
Biomechanical Phenomena
;
Bone Screws
;
Finite Element Analysis
;
Humans
;
Mandibular Fractures/surgery*
;
Bone Plates
;
Titanium
;
Stress, Mechanical
3.Efficacy and Safety of Systemic Thrombolysis in the Treatment of Lower Extremity Fracture Complicated With Distal Deep Vein Thrombosis.
Shi-Qiang LIAO ; Shu-Ming SHI ; Qiang ZHANG ; Chuan-Yong LI ; Guang-Feng ZHENG ; Zhi-Chang PAN ; Jian-Jie RONG
Acta Academiae Medicinae Sinicae 2025;47(2):237-243
Objective To evaluate the efficacy and safety of systemic thrombolysis(ST)and standard anticoagulation(SA)in the treatment of lower extremity fracture complicated with distal deep vein thrombosis(DDVT).Methods We retrospectively analyzed the clinical data of 60 patients with lower extremity fracture complicated with DDVT treated from January 2021 to December 2023.When the lower limb venography indicated a calf thrombus burden score ≥3 points,a retrievable inferior vena cava filter(IVCF)was successfully placed in the healthy femoral vein before orthopedic surgery.The patients who received further anticoagulant or thrombolytic therapy after surgery were allocated into a ST group(n=30,urokinase ST and SA)and a SA group(n=30,only SA).The two groups were compared in terms of calf thrombus burden score,thrombus dissolution rate,IVCF placement time,IVCF retrieval rate,intercepted thrombi,hemoglobin level,platelet count,D-dimer level,and complications.Results There was no statistically significant difference in the calf thrombus burden score between the two groups before treatment(P=0.431).However,after treatment,the scores in both groups decreased(both P<0.001),with the ST group showing lower score than the SA group(P=0.002).The thrombus dissolution rate in the ST group was higher than that in the SA group(P<0.001).There was no statistically significant difference in the IVCF placement time between the two groups(P=0.359),and the IVCF retrieval rate was 100% in both groups.The ST group had fewer intercepted thrombi than the SA group(P=0.002).There was no statistically significant difference in hemoglobin level(P=0.238),platelet count(P=0.914),or D-dimer level(P=0.756)between the two groups before treatment.However,after treatment,both groups showed an increase in platelet count(both P<0.001)and a decrease in D-dimer level(both P<0.001).There was no statistically significant difference in the occurrence of complications between the two groups(P=0.704).Conclusions Both SA and ST demonstrate safety and efficacy in the treatment of lower extremity fractures complicated with DDVT,serving as valuable options for clinical application.Compared with SA,ST not only enhances the thrombus dissolution in the calf but also mitigates the risk of thrombosis associated with IVCF.
Humans
;
Venous Thrombosis/therapy*
;
Retrospective Studies
;
Thrombolytic Therapy/methods*
;
Male
;
Female
;
Middle Aged
;
Fractures, Bone/complications*
;
Lower Extremity/injuries*
;
Anticoagulants/therapeutic use*
;
Aged
;
Treatment Outcome
;
Adult
4.The epidemiology and distribution of hand fractures in Singapore.
Jin Xi LIM ; Lan Anh Thi LE ; Jared Ze Yang YEH ; Jia Jun Justin BOEY ; Vaikunthan RAJARATNAM
Singapore medical journal 2025;66(9):476-480
INTRODUCTION:
The aim of this study was to elucidate the epidemiology and distribution of hand fractures in Singapore.
METHODS:
A total of 701 hand fractures in 596 patients aged 21 years and above from a single centre were reviewed from 2010 to 2011. Details regarding the patient demographics, occupation, mechanism of injury, associated injuries and treatment were obtained.
RESULTS:
Hand fractures were particularly significant in patients between the ages of 21 and 40 years 58.9% of the total cases. The relative risk of hand fractures in males was 5.5 times greater than that in females. The majority of hand fractures occurred at the workplace (47.7%), with crush injury being the main mechanism of injury (33.6%). The most common locations of hand fracture were the little finger ray (31.2%) and distal phalanges (37.7%). There were 170 cases that underwent surgical fixation, which accounted for 24.3% of all fractures. Fixation rate was similar for both closed and open fractures but was significantly higher in the proximal and middle phalanges compared to the distal phalanx and metacarpal ( P < 0.001). With regards to surgical fixation methods, wires were commonly used in either tuft fractures (100.0%) or intra-articular fractures (69.9%), whereas plates and screws were commonly used in shaft fractures (65.5%).
CONCLUSION
The most significant population that sustained hand fractures in Singapore are young to middle-aged males who are skilled manual workers. The most commonly involved ray and location of hand fractures are the little finger ray and the distal phalanges, respectively, as they are in a relatively more exposed location.
Humans
;
Singapore/epidemiology*
;
Male
;
Female
;
Adult
;
Middle Aged
;
Fractures, Bone/surgery*
;
Hand Injuries/surgery*
;
Young Adult
;
Aged
;
Hand Bones/injuries*
;
Retrospective Studies
;
Fracture Fixation, Internal
5.Deploying artificial intelligence in the detection of adult appendicular and pelvic fractures in the Singapore emergency department after hours: efficacy, cost savings and non-monetary benefits.
John Jian Xian QUEK ; Oliver James NICKALLS ; Bak Siew Steven WONG ; Min On TAN
Singapore medical journal 2025;66(4):202-207
INTRODUCTION:
Radiology plays an integral role in fracture detection in the emergency department (ED). After hours, when there are fewer reporting radiologists, most radiographs are interpreted by ED physicians. A minority of these interpretations may miss diagnoses, which later require the callback of patients for further management. Artificial intelligence (AI) has been viewed as a potential solution to augment the shortage of radiologists after hours. We explored the efficacy of an AI solution in the detection of appendicular and pelvic fractures for adult radiographs performed after hours at a general hospital ED in Singapore, and estimated the potential monetary and non-monetary benefits.
METHODS:
One hundred and fifty anonymised abnormal radiographs were retrospectively collected and fed through an AI fracture detection solution. The radiographs were re-read by two radiologist reviewers and their consensus was established as the reference standard. Cases were stratified based on the concordance between the AI solution and the reviewers' findings. Discordant cases were further analysed based on the nature of the discrepancy into overcall and undercall subgroups. Statistical analysis was performed to evaluate the accuracy, sensitivity and inter-rater reliability of the AI solution.
RESULTS:
Ninety-two examinations were included in the final study radiograph set. The AI solution had a sensitivity of 98.9%, an accuracy of 85.9% and an almost perfect agreement with the reference standard.
CONCLUSION
An AI fracture detection solution has similar sensitivity to human radiologists in the detection of fractures on ED appendicular and pelvic radiographs. Its implementation offers significant potential measurable cost, manpower and time savings.
Humans
;
Singapore
;
Emergency Service, Hospital
;
Fractures, Bone/diagnostic imaging*
;
Artificial Intelligence
;
Retrospective Studies
;
Adult
;
Male
;
Female
;
Cost Savings
;
Middle Aged
;
Pelvic Bones/diagnostic imaging*
;
Reproducibility of Results
;
Aged
;
Sensitivity and Specificity
;
Radiography
6.Biomechanical study on wing shaped titanium plate fixation of acetabular anterior column and posterior hemi-transverse fracture under multiple working conditions.
Jianwu ZHANG ; WURIKAIXI AIYITI ; Gang LYU ; MAIMAIAILI YUSHAN ; Zhiqiang MA ; Chao MA
Journal of Biomedical Engineering 2025;42(2):351-358
This article aims to compare and analyze the biomechanical differences between wing-shaped titanium plates and traditional titanium plates in fixing acetabular anterior column and posterior hemi-transverse (ACPHT) fracture under multiple working conditions using the finite element method. Firstly, four sets of internal fixation models for acetabular ACPHT fractures were established, and the hip joint stress under standing, sitting, forward extension, and abduction conditions was calculated through analysis software. Then, the stress of screws and titanium plates, as well as the stress and displacement of the fracture end face, were analyzed. Research has found that when using wing-shaped titanium plates to fix acetabular ACPHT fractures, the peak stress of screws decreases under all working conditions, while the peak stress of wing-shaped titanium plates decreases under standing and sitting conditions and increases under forward and outward extension conditions. The relative displacement and mean stress of the fracture end face decrease under all working conditions, but the values are higher under forward and outward extension conditions. Wing-shaped titanium plates can reduce the probability of screw fatigue failure when fixing acetabular ACPHT fractures and can bear greater loads under forward and outward extension conditions, improving the mechanical stability of the pelvis. Moreover, the stress on the fracture end surface is more conducive to stimulating fracture healing and promoting bone tissue growth. However, premature forward and outward extension rehabilitation exercises should not be performed.
Titanium
;
Bone Plates
;
Humans
;
Acetabulum/surgery*
;
Fracture Fixation, Internal/methods*
;
Biomechanical Phenomena
;
Finite Element Analysis
;
Bone Screws
;
Fractures, Bone/surgery*
;
Stress, Mechanical
;
Working Conditions
7.Risk Factors for Prolonged Postoperative Length of Stay After Hip Fracture Surgery in Very Elderly Patients.
Bo-Wen XU ; Wei-Yun CHEN ; Chen SUN ; Ling LAN ; Lu-Lu MA ; Li-Jian PEI
Chinese Medical Sciences Journal 2025;40(2):111-119
OBJECTIVES:
To identify risk factors contributing to prolonged postoperative length of stay (LOS) in very elderly patients following hip fracture surgery, with a focus on postoperative complications and the impact of different anesthesia approaches.
METHODS:
This retrospective single-center cohort study enrolled patients aged 90 years or older who underwent hip fracture surgery at Peking Union Medical College Hospital between January 31, 2013 and December 31, 2023. Relevant perioperative data were collected. The primary outcome was postoperative LOS, and the study cohort was divided into two groups: postoperative LOS ≤ 7 days and LOS > 7 days. Logistic regression was performed to identify factors related to prolonged postoperative LOS.
RESULTS:
A total of 155 patients were included. The average age was 92.7 ± 2.6 years. There were 73 (47%) patients with postoperative LOS > 7 days. Postoperative pneumonia was the only factor associated with a prolonged postoperative LOS (OR = 2.12, 95% CI [1.09, 4.16], P = 0.028). Neither the type of anesthesia (regional vs. general anesthesia, OR = 1.00, 95% CI [0.53, 1.90], P = 0.993) nor the method of airway management (laryngeal mask ventilation vs. spontaneous breathing, OR = 1.46, 95% CI [0.58, 3.76], P = 0.424; endotracheal intubation vs. spontaneous breathing, OR = 0.82, 95% CI [0.39, 1.69], P = 0.592) showed a significant association with a prolonged postoperative LOS. Preoperative chronic obstructive pulmonary disease (OR = 2.78, 95% CI [1.05, 7.65], P = 0.040) and preoperative neutrophil count (OR = 1.13, 95% CI [1.01, 1.26], P = 0.029) were both significantly associated with the occurrence of postoperative pneumonia, while anesthesia type and airway management method were not.
CONCLUSIONS
Postoperative pneumonia was associated with prolonged postoperative LOS in very elderly patients undergoing hip fracture surgery, whereas anesthesia types and airway management methods show no association with prolonged postoperative LOS or postoperative pneumonia. Preoperative comorbidities, especially respiratory conditions and systemic inflammation, potentially play a substantial role in postoperative recovery.
Humans
;
Hip Fractures/surgery*
;
Aged, 80 and over
;
Risk Factors
;
Length of Stay
;
Female
;
Male
;
Retrospective Studies
;
Postoperative Complications/etiology*
8.Postoperative Complications and 30-day Readmission in Patients Older than 80 Years with Chronic Kidney Disease after Hip Fracture.
Hua-Wen ZHANG ; Lu-Lu MA ; Xue-Rong YU
Chinese Medical Sciences Journal 2025;40(3):188-196
OBJECTIVES:
This study aimed to explore the impact of chronic kidney disease (CKD) on prognosis of patients older than 80 years after hip fracture.
METHODS:
This retrospective, observational, single-center study included patients older than 80 years who underwent hip fracture operations between Feburary 2013 to June 2021 at our hospital. Patients were divided into CKD and non-GKD groups based on the estimated glomerular filtration rate (eGFR) < 60 mL/(min·1.73m2)] or not. Outcomes were the incidence of in-hospital postoperative infectious and non-infectious complications, 30-day readmission, and in-hospital death. Logistic regression analysis was used to calculate the odds ratio (OR) of CKD on these outcomes.
RESULTS:
A total of 498 patients were included, 165 in the CKD group and 333 in the non-CKD group. Eighty-seven (52.7%) CKD patients experienced 140 episodes of postoperative complications. In comparison, 114 (34.2%) non-CKD patients had 158 episodes of postoperative complications. CKD patients were more likely to have postoperative complications than non-CKD patients (OR = 2.143, 95% CI: 1.465-3.134, P < 0.001). CKD increased the risk of cardiovascular complications (OR = 2.044, 95% CI: 1.245-3.356, P = 0.004), acute kidney injury (OR = 3.401, 95% CI: 1.905-6.072, P < 0.001), delirium (OR = 2.276, 95% CI: 1.140-4.543, P = 0.024), and gastrointestinal bleeding (OR = 4.151, 95% CI: 1.025-16.812, P = 0.031). The transfusion rate (OR = 2.457, 95% CI: 1.668-3.618, P < 0.001) and incidence of 30-day readmission (OR = 2.426, 95% CI:1.203-4.892, P = 0.011) in CKD patients were significantly higher than those in patients without CKD.
CONCLUSIONS
CKD is associated with poor postoperative outcomes in geriatric hip fracture patients. Special attention should be paid to patients with CKD.
Humans
;
Renal Insufficiency, Chronic/physiopathology*
;
Aged, 80 and over
;
Postoperative Complications/epidemiology*
;
Hip Fractures/complications*
;
Male
;
Female
;
Patient Readmission/statistics & numerical data*
;
Retrospective Studies
;
Glomerular Filtration Rate
9.TiRobot-assisted minimally invasive treatment of coracoid process fractures of scapula.
Yonghong DAI ; Qingyu LI ; Yanhui ZENG ; Zhengjie WU ; Chunpeng ZHAO ; Junqiang WANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):40-46
OBJECTIVE:
To explore effectiveness of TiRobot-assisted screw implantation in the treatment of coracoid process fractures of the scapula.
METHODS:
A retrospective analysis was conducted on the clinical data from 24 patients with coracoid process fractures of the scapula admitted between September 2019 and January 2024 and met selection criteria. Among them, 12 patients underwent TiRobot-assisted screw implantation (robot group) and 12 underwent manual screw implantation (control group) during internal fixation. There was no significant difference ( P>0.05) in baseline data such as gender, age, body mass index, disease duration, cause of injury, coracoid process fracture classification, and proportion of patients with associated injuries between the two groups. The incision length, operation time, intraoperative blood loss, hospital stay, accuracy of screw placement, coracoid process fracture healing time, and complications were recorded and compared, as well as pain visual analogue scale (VAS) score, and Constant-Murley score at last follow-up.
RESULTS:
The intraoperative blood loss and incision length in the robot group were significantly lower than those in the control group ( P<0.05); however, there was no significant difference in operation time and hospital stay between the two groups ( P>0.05). All patients were followed up 8-27 months (mean, 17.5 months), and the difference in follow-up time between the two groups was not significant ( P>0.05). At last follow-up, the VAS score for shoulder pain in the robot group was signifncatly lower compared to the control group, and the Constant-Murley score was significantly higher ( P<0.05). In the robot group, 16 screws were implanted intraoperatively, while 13 screws were implanted in the control group. Radiographic re-evaluation showed that the excellent and good rate of screw implantation was higher in the robot group (93.8%, 15/16) than in the control group (61.5%, 8/13), but the difference in the precision of screw implantation between the two groups was not significant ( P>0.05). Four patients in the robot group and 1 in the control group achieved double screws fixation; however, the difference in achieving double screws fixation between the two groups was not significant ( P>0.05). All fractures healed in both groups with 1 case of malunion in the control group. There was no significant difference in healing time between the two groups ( P>0.05). During follow-up, 1 patient in the control group experienced screw loosening and displacement. There was no significant difference in the incidence of screw loosening and fracture malunion between the two groups ( P>0.05).
CONCLUSION
Compared with manual screw implantation, TiRobot-assisted minimally invasive treatment of coracoid process fractures of the scapula can reduce intraoperative blood loss, shorten incision length, alleviate pain, and obtain better promote shoulder joint functional recovery.
Humans
;
Male
;
Female
;
Retrospective Studies
;
Fracture Fixation, Internal/instrumentation*
;
Minimally Invasive Surgical Procedures/instrumentation*
;
Adult
;
Middle Aged
;
Fractures, Bone/surgery*
;
Bone Screws
;
Coracoid Process/surgery*
;
Robotic Surgical Procedures/methods*
;
Scapula/surgery*
;
Treatment Outcome
;
Operative Time
;
Young Adult
;
Length of Stay
;
Blood Loss, Surgical
10.Short-term effectiveness of Gamma 3 U-Blade system for osteoporotic intertrochanteric fractures in the elderly.
Wenbin FAN ; Liu SHI ; Tian XIE ; Cheng ZHANG ; Xiangxu CHEN ; Hui CHEN ; Yunfeng RUI
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):47-52
OBJECTIVE:
To compare the short-term effectiveness between Gamma 3 intramedullary nails and Gamma 3 U-Blade system in the treatment of osteoporotic intertrochanteric fractures in the elderly.
METHODS:
A retrospective analysis was conducted on the clinical data of 124 elderly patients with osteoporotic intertrochanteric fractures, who were admitted between February 2020 and February 2023 and met the selection criteria. The fractures were fixed with Gamma 3 intramedullary nails in 65 patients (control group) and Gamma 3 U-Blade systems in 59 patients (UB group). The differences between the two groups were not significant in age, gender, body mass index, American Society of Anesthesiologists (ASA) classification, bone mineral density, time from injury to operation, fracture classification, and affected side ( P>0.05). The operation time, intraoperative blood loss, hospital stay, and fracture healing time were recorded; the tip-apex distance, fracture reduction quality, and lag screw position were evaluated on X-ray films at immediate after operation; the lag screw sliding distance and change value of neck-shaft angle were measured on X-ray films at last follow-up. Harris hip score at 1 year after operation and the occurrence of internal fixation-related complications were compared between the two groups.
RESULTS:
The operation time, intraoperative blood loss, and hospital stay in the UB group increased compared to the control group, but the differences were not significant ( P>0.05). All patients in both groups were followed up 12-24 months (mean, 17.1 months). At 12 months after operation, there was no significant difference in the Harris hip score between the two groups ( P<0.05). Radiological examination showed that there was no significant difference between the two groups ( P>0.05) in terms of tip-apex distance, fracture reduction quality, and lag screw position. Fractures healed in both groups, and there was no significant difference in healing time ( P>0.05). At last follow-up, the change value of neck-shaft angle and lag screw sliding distance in the UB group were significantly lower than those in the control group ( P<0.05). During follow-up, no related complications occurred in the UB group, while 6 cases (9.2%) in the control group experienced complications, and the difference in the incidence was significant ( P<0.05).
CONCLUSION
For the osteoporotic intertrochanteric fractures in the elderly, the Gamma 3 U-Blade system fixation can achieve good short-term effectiveness, with better imaging results compared to Gamma 3 intramedullary nails fixation.
Humans
;
Retrospective Studies
;
Hip Fractures/surgery*
;
Male
;
Female
;
Aged
;
Fracture Fixation, Intramedullary/methods*
;
Osteoporotic Fractures/surgery*
;
Bone Nails
;
Bone Screws
;
Aged, 80 and over
;
Treatment Outcome
;
Fracture Healing
;
Operative Time
;
Length of Stay


Result Analysis
Print
Save
E-mail