1.Biomechanical analysis of three kinds of rigid internal fixation methods for condylar head fractures.
Junhui SUN ; Duoduo LAN ; Dong WANG ; Yao XU ; Zeyu WANG ; Chenchen ZHANG ; Kai ZHANG ; Tao XU
West China Journal of Stomatology 2025;43(1):126-132
OBJECTIVES:
This study aims to analyze the biomechanics of three kinds of rigid internal fixation methods for condylar head fractures.
METHODS:
A three dimensional finite element model of the normal mandible was constructed. It was then used to prepare condylar head fracture finite element model and three kinds of rigid internal fixation finite element model (unilateral tension screw, bilateral tension screw, tension screw+titanium plate). The mechanical characteristics and changes of the mandible condyle under the same mechanical conditions were compared among the three different rigid internal fixation methods.
RESULTS:
The maximum equivalent stress and displacement of the non-free end of condyle under the rigid internal fixation method of unilateral tension screw were 71.03 MPa and 4.72 mm, respectively. The maximum equivalent stress and displacement of the free end of condyle were 78.45 MPa and 4.50 mm, respectively. The maximum stress of fracture suture was 3.27 MPa. The maximum equivalent stress and displacement of the non-free end of condyle under the rigid internal fixation method of bilateral tension screw were 70.52 MPa and 4.00 mm, respectively. The maximum equivalent stress and displacement of the free end of condyle were 72.49 MPa and 3.85 mm, respectively. The maximum stress of fracture suture was 2.33 MPa. The maximum equivalent stress and maximum displacement of the non-free end of condyle under the rigid internal fixation method of tension screw+titanium plate were 67.26 MPa and 2.66 mm, respectively. The maximum equivalent stress and maximum displacement of the free end of condyle were 69.66 MPa and 2.50 mm, respectively. The maximum stress of fracture suture was 2.18 MPa.
CONCLUSIONS
The tension screw+titanium plate rigid internal fixation method is the most conducive to biomechanical distribution for condylar head fractures.
Fracture Fixation, Internal/instrumentation*
;
Mandibular Condyle/surgery*
;
Biomechanical Phenomena
;
Bone Screws
;
Finite Element Analysis
;
Humans
;
Mandibular Fractures/surgery*
;
Bone Plates
;
Titanium
;
Stress, Mechanical
2.Measurement and clinical validation of safe distance for LC- Ⅱ screw placement using iliac oblique view.
Hongwei FU ; Ansu WANG ; Lin CHEN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(10):1304-1309
OBJECTIVE:
To define a safe distance range from the LC-Ⅱ screw trajectory to the apex of the greater sciatic notch based on pelvic CT measurements, and to clinically assess the feasibility of using this range under iliac oblique view combined with iliac tangential view fluoroscopy to guide screw insertion.
METHODS:
CT scans of 104 normal pelvises collected between January 2022 and February 2025 were analyzed. There were 52 males and 52 females, with a median age of 45.8 years (range, 19-76 years). The RadiAnt DICOM Viewer software was used to reconstruct coronal, sagittal, and axial sections of the potential LC-Ⅱ screw trajectory. The maximum safety distance (Dmax) and the optimal safety distance (Dopt) from this trajectory to the greater sciatic notch were measured on the coronal and sagittal views. A retrospective analysis was conducted on 21 patients with LC-Ⅱ type pelvic fractures treated with the LC-Ⅱ screws fixation. And the screws were placed within the pre-defined safe distance under guidance from the iliac oblique view and iliac tangential view. Postoperative CT scans were obtained to evaluate the accuracy of screw placement.
RESULTS:
Radiographic measurements from the 104 cases showed that Dmax ranged from 1.87 to 3.87 cm (mean, 2.79 cm), and Dopt ranged from 1.01 to 2.92 cm (mean, 1.84 cm). Both Dmax and Dopt were significantly greater in the males than in the females ( P>0.05). No significant difference was found between the left and right sides within the same gender ( P>0.05). All 21 patients successfully underwent fracture reduction and fixation, with a total of 23 LC-Ⅱscrews implanted. According to the Lonstein grading system, the screw placement accuracy was rated as excellent in 16 screws, good in 3, fair in 3, and poor in 1, with an excellent and good rate of 82.6%.
CONCLUSION
Utilizing a CT-defined safe distance range from the screw trajectory to the greater sciatic notch, and adhering to this range under iliac oblique view combined with iliac tangential view fluoroscopy, enables the accurate and precise placement of LC-Ⅱ screws.
Humans
;
Male
;
Female
;
Middle Aged
;
Bone Screws
;
Adult
;
Tomography, X-Ray Computed/methods*
;
Aged
;
Ilium/surgery*
;
Pelvic Bones/diagnostic imaging*
;
Fracture Fixation, Internal/instrumentation*
;
Retrospective Studies
;
Fluoroscopy
;
Fractures, Bone/diagnostic imaging*
;
Young Adult
3.Clinical study of percutaneous short-segment injured vertebra pedicle screw fixation combined with bone grafting in treatment of thoracolumbar fractures.
Long JIA ; Xiangqian LI ; Yadong QIAN ; Mingji CHEN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(10):1310-1317
OBJECTIVE:
To compare the effectiveness of percutaneous short-segment injured vertebra pedicle screw fixation combined with bone grafting versus percutaneous short-segment injured vertebra pedicle screw fixation alone for the treatment of thoracolumbar fractures.
METHODS:
The clinical data of 54 patients with single-level thoracolumbar fractures who met the selection criteria between January 2023 and February 2024 were retrospectively analysed. Based on whether bone grafting was performed on the injured vertebra, the patients were divided into a control group (28 cases, percutaneous short-segment injured vertebra pedicle screw fixation alone) and a study group (26 cases, percutaneous short-segment injured vertebra pedicle screw fixation combined with bone grafting using a self-made minimally invasive bone grafting funnel). No significant difference was observed between the two groups ( P>0.05) in baseline data, including age, gender, surgical segment, cause of injury, AO classification, and preoperative anterior-vertebral height compression ratio, mid-vertebral height compression ratio, Cobb angle, visual analogue scale (VAS) score, and Oswestry Disability Index (ODI). The operation time, intraoperative blood loss, fracture healing status, removal time of internal fixator, and complications were recorded and compared between the two groups. Effectiveness was assessed using anterior-vertebral height compression ratio, mid-vertebral height compression ratio, Cobb angle, VAS scores, and ODI taken preoperatively, at 1 week postoperatively, and at last follow-up.
RESULTS:
All patients in both groups successfully underwent surgery. The operation time and intraoperative blood loss in the control group were significantly less than those in the study group ( P<0.05). No significant difference was observed in the follow-up time between the study group [(14.46±2.00) months] and control group [(14.36±1.83) months] ( P>0.05). The fracture healing time of the study group was significantly shorter than that of the control group ( P<0.05). One patient in the study group was found to have bilateral titanium rod breakage by X-ray reexamination at 8 months after operation, and there was no subsequent vertebral height collapse occurred, and the internal fixator was removed following complete fracture healing. The other patients had no complication such as spinal cord injury, internal fixator loosening and breakage. There was no significant difference in the removal time of internal fixator between the two groups ( P<0.05). The anterior-vertebral height compression ratio, mid-vertebral height compression ratio, Cobb angle, VAS score, and ODI significantly improved in both groups at 1 week after operation and at last follow-up ( P<0.05). Among them, the VAS score, and ODI further improved at last follow-up when compared with at 1 week after operation, Cobb angle lost a little at 1 week after operation, while anterior-vertebral height compression ratio and mid-vertebral height compression ratio slightly increased when compared with 1 week after operation, and the differences were significant ( P<0.05). There was no significant difference between the two groups in Cobb angle at last follow-up, VAS score and ODI at 1 week after operation ( P>0.05), while the other indicators in the study group were significantly better than those in the control group at all time points ( P<0.05).
CONCLUSION
Compared to percutaneous short-segment injured vertebra pedicle screw fixation alone, the technique combined with intravertebral bone grafting can shorten fracture healing time, effectively restore and maintain vertebral body height, correct kyphotic deformity, and improve clinical outcomes for patients with thoracolumbar fractures.
Humans
;
Thoracic Vertebrae/surgery*
;
Pedicle Screws
;
Lumbar Vertebrae/surgery*
;
Spinal Fractures/surgery*
;
Bone Transplantation/methods*
;
Fracture Fixation, Internal/instrumentation*
;
Male
;
Female
;
Retrospective Studies
;
Adult
;
Middle Aged
;
Treatment Outcome
;
Minimally Invasive Surgical Procedures/methods*
;
Operative Time
;
Aged
4.Effectiveness comparison of medial-lateral approach and posteromedian approach in release of elbow stiffness after distal humeral fractures surgery.
Lingzhe XUAN ; Hongru MA ; Fengfeng LI
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(11):1395-1401
OBJECTIVE:
To investigate the difference of effectiveness between medial-lateral approach and posteromedian approach in the release of elbow stiffness after distal humeral fracture surgery.
METHODS:
A retrospective analysis was conducted on the clinical data of 41 patients with elbow stiffness following medial and lateral plate fixation for distal humeral fractures, admitted between January 2021 and June 2023 and meeting selection criteria. Patients were divided into the medial-lateral approach release group (study group, 20 cases) and the posteromedian approach release group (control group, 21 cases) based on surgical approach. Baseline data including age, gender, affected side, body mass index, disease duration, and preoperative extension angle, flexion angle, range of motion, visual analogue scale (VAS) pain score, Mayo elbow performance score, ulnar nerve symptoms, and heterotopic ossification showed no significant difference between groups ( P>0.05). The operation time, intraoperative blood loss, and complication incidence were recorded and compared between groups. Clinical effectiveness was evaluated using pre- and postoperative Mayo score, VAS score, elbow extension/flexion angles, and range of motion on the affected side. Statistical analysis focused on changes in these indicators relative to preoperative values.
RESULTS:
There was no significant difference in operation time and intraoperative blood loss between the two groups ( P>0.05). Patients in both groups were followed up 15-36 months, with a mean of 23.8 months; there was no significant difference in the follow-up time between the two groups ( t=-1.542, P=0.131). In the control group, 1 patient had obvious subcutaneous hematoma and 5 patients had poor wound healing within 2 months after operation, all of which were cured by symptomatic treatment, while no related complications occurred in the study group, there was a significant difference in poor wound healing incidence between the two groups ( P<0.05). At last follow-up, 2 patients in the study group and 3 patients in the control group had mild symptoms of ulnar nerve numbness, and there was no significant difference in the incidence of ulnar nerve symptoms ( P>0.05). All patients had no recurrence or new onset of heterotopic ossification, no skin necrosis or reoperation due to complications. At last follow-up, elbow extension angle, flexion angle, flexion-extension range of motion, VAS score, and Mayo score significantly improved in both groups when compared with the preoperative ones ( P<0.05). There was no significant difference between the change values in elbow extension angle and VAS score between the two groups ( P>0.05); the change values in flexion angle, range of motion, and Mayo score in the study group were significantly better than those in the control group ( P<0.05).
CONCLUSION
The medial-lateral approach can release the elbow stiffness and concurrently remove the medial, lateral, or posterior lateral plates. The incision minimizes disruption to rehabilitation exercises and reduces complications like inadequate wound healing, ultimately leading to improved treatment outcomes.
Humans
;
Humeral Fractures/surgery*
;
Male
;
Female
;
Retrospective Studies
;
Elbow Joint/physiopathology*
;
Middle Aged
;
Fracture Fixation, Internal/adverse effects*
;
Range of Motion, Articular
;
Adult
;
Bone Plates
;
Postoperative Complications/surgery*
;
Treatment Outcome
;
Aged
;
Humeral Fractures, Distal
5.TiRobot-assisted minimally invasive treatment of geriatric fragility fractures of the pelvis.
Canhui LI ; Yonghong DAI ; Weiqiong CAI ; Xiaopeng SITU ; Yanhui ZENG ; Xuelian DU ; Shi HONG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(11):1421-1427
OBJECTIVE:
To investigate the effectiveness of TiRobot-assisted minimally invasive treatment for fragility fractures of the pelvis (FFP) in elderly patients.
METHODS:
A retrospective analysis was conducted on the clinical data of 176 patients with FFP who were admitted between July 2018 and July 2024 and met the selection criteria. Among them, 95 patients underwent TiRobot-assisted closed reduction and minimally invasive cannulated screw fixation (robot group), while 81 patients underwent traditional open reduction and plate screw fixation (control group). There was no significant difference in baseline data such as gender, age, fracture classification, disease duration, and preoperative visual analogue scale (VAS) pain scores between the two groups ( P>0.05). The following parameters were recorded and compared between the two groups, including operation time, intraoperative blood loss, intraoperative transfusion rate, volume of intraoperative blood transfusion, maximum incision length, hospital stay, maximum residual displacement, reduction quality, fracture healing time, incidence of complications, VAS scores, Majeed pelvic function scores, and functional grading.
RESULTS:
All surgeries in both groups successfully completed. The robot group exhibited significantly shorter operation time, reduced intraoperative blood loss, lower intraoperative transfusion rate, smaller volume of intraoperative blood transfusion, shorter maximum incision length, and shorter hospital stay compared to the control group ( P<0.05). In the robot group, a total of 14 INFIX internal fixation frames and 280 cannulated screws were implanted, among which 250 screws were rated as excellent, 17 as good, and 13 as poor, resulting in a screw placement excellent and good rate of 95.36%. Radiological review revealed that the excellent and good rate of reduction quality was in 91.58% (87/95) in the robot group and 81.48% (66/81) in the control group, with no significant difference in postoperative maximum residual fracture displacement or reduction quality between the two groups (P>0.05). All patients in both groups were followed up 12-66 months, with an average of 28.9 months, and there was no significant difference in follow-up time between the two groups ( P>0.05). The fracture healing time in the robot group was significantly shorter than that in the control group ( P<0.05). At last follow-up, both groups showed significant improvement in VAS scores compared to preoperative values ( P<0.05); the change values of VAS scores, Majeed scores, and the excellent and good rate of Majeed pelvic function were significantly higher in the robot group than in the control group ( P<0.05). Regarding postoperative complications, there was no significant difference between the two groups in terms of gait changes, secondary surgeries, heterotopic ossification, incision infections, walking difficulties, internal fixation failure, or mortality rates ( P>0.05); however, the incidence of delayed wound healing was significantly lower in the robot group than in the control group ( P<0.05).
CONCLUSION
TiRobot-assisted minimally invasive treatment of elderly FFP is superior to traditional open reduction and internal fixation in terms of surgical trauma control, postoperative rehabilitation speed, and functional recovery.
Humans
;
Male
;
Retrospective Studies
;
Female
;
Minimally Invasive Surgical Procedures/instrumentation*
;
Fracture Fixation, Internal/instrumentation*
;
Pelvic Bones/surgery*
;
Aged
;
Bone Screws
;
Bone Plates
;
Robotic Surgical Procedures/methods*
;
Aged, 80 and over
;
Treatment Outcome
;
Osteoporotic Fractures/surgery*
;
Operative Time
;
Blood Loss, Surgical
;
Fracture Healing
;
Fractures, Bone/surgery*
6.Effectiveness of staged therapy using external fixation frame for infectious nonunion near knee joint.
Zhiguo WANG ; Xiaoguang GUO ; Zheng KANG ; Xinwei WANG ; Guoqiang JIN ; Honglue TAN ; Xiaohui DENG ; Weihua FENG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(11):1428-1434
OBJECTIVE:
To explore the methods, fixation points, and effectiveness of staged therapy using external fixation frame in treatment of infectious nonunion near knee joint.
METHODS:
A retrospective analysis was conducted on the clinical data of 60 patients with infectious nonunion near knee joint, who underwent staged therapy using external fixation frame between June 2021 and June 2024 and were followed up. There were 48 males and 12 females with an average age of 47.9 years (range, 16-70 years). The disease duration ranged from 9 months to 20 years, with a median of 14 months. Among them, 21 cases of infectious nonunion located in the distal femur, 36 cases in the proximal tibia, and 3 cases in the patella; 12 cases exhibited segmental bone defects (≥4 cm), while 48 cases presented with localized bone defects (<4 cm). Osteomyelitis was classified using the Cierny-Mader system, with 3 cases classified as type Ⅰ, 6 cases as type Ⅱ, 35 cases as type Ⅲ, and 16 cases as type Ⅳ. Preoperative C-reactive protein levels ranged from 15.1 to 55.8 mg/L (mean, 36.4 mg/L). The erythrocyte sedimentation rate was 35-80 mm/1 h (mean, 56.9 mm/1 h). The Hospital for Special Surgery (HSS) score for knee joint was 69.3±17.7 and the range of motion was (70.61±40.60)°. After debridement and placement of antibiotic carriers at the first-stage operation, unilateral orbital frames ( n=14), combined frames ( n=27), or Ilizarov frames ( n=19) were used for cross joint fixation ( n=9) or joint preservation fixation ( n=51). After 6-8 weeks of infection control, the bone grafting or bone transport was performed at the second-stage operation based on the type of bone defect, with internal fixation employed as an adjunct if necessary. After operation, the infection control and fracture healing were observed and the bone healing time was recorded. The knee joint function was assessed using the HSS score, and the knee joint range of motion was measured as well as the angle of motion loss. Patients were grouped according to the site of nonunion, type of external fixation frame, and fixation method. The bone healing time, change value of HSS score, and knee joint range of motion loss (difference between pre- and post-operation) were compared between groups.
RESULTS:
All infection markers returned to the normal range within 6 weeks after the first-stage operation. All patients were followed up 12-48 months (mean, 22.0 months) after the second-stage operation. There were 5 cases of needle tract infection during the external fixation period, and 3 cases of infection recurrence after the second-stage operation, all of which were cured after symptomatic treatment. The bone healing time was 6-18 months (mean, 11.0 months). At last follow-up, the HSS score was 88.5±7.9 and the range of motion was (61.84±40.59)°, with significant differences compared to preoperative values ( P<0.05); the knee joint range of motion loss was (8.77±11.07)°. The bone healing time was significantly longer in the distal femur group than in the proximal tibia group ( P<0.05), and in the unilateral orbital frames group than in the Ilizarov frames group and the combined frames group ( P<0.05). The angle of motion loss was significantly larger in the Ilizarov frames group than in the unilateral orbital frames group and the combined frames group ( P<0.05). The change value of HSS score was significantly higher in the cross joint fixation group than in the joint preservation fixation group ( P<0.05).
CONCLUSION
During the first-stage operation, debridement is performed and antibiotic carriers are placed to control infection. External fixation frames are then precisely positioned based on the distance between the lesion and the joint surface, avoiding the infected wound while ensuring mechanical balance. During the second-stage operation, bone grafting options are selected according to the extent of bone defects to enhance the bone union. Postoperative early functional exercises of the knee joint are permitted to improve joint function.
Humans
;
Male
;
Female
;
Middle Aged
;
Adult
;
Fractures, Ununited/surgery*
;
Retrospective Studies
;
External Fixators
;
Aged
;
Knee Joint/surgery*
;
Adolescent
;
Young Adult
;
Treatment Outcome
;
Osteomyelitis/surgery*
;
Fracture Fixation/instrumentation*
;
Bone Transplantation
;
Tibial Fractures/surgery*
7.Clinical study on reduction of posterior malleolar fractures via modified Rammelt transfibular approach.
Shaozhen JI ; Jianyi LEI ; Jianbo GUO ; Dehang LIU ; Xiangliang GE ; Jinxi HU ; Shixin LIU ; Zhenhui SUN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(11):1441-1446
OBJECTIVE:
To evaluate the safety and effectiveness of reducing posterior malleolar fractures via the modified Rammelt transfibular approach.
METHODS:
A retrospective analysis was conducted on 26 patients with ankle fractures who met the selection criteria and were admitted between September 2023 and May 2024. There were 13 males and 13 females, aged from 14 to 59 years (median, 43.5 years). Causes of injury included traffic accident (1 case), falls (7 cases), and sprains (18 cases). Time from injury to operation ranged from 1 to 13 days (mean, 3.9 days). According to the Lauge-Hansen classification, there were 5 supination-external rotation type Ⅲ fractures and 21 supination-external rotation type Ⅳ fractures. According to the Bartoníček classification for posterior malleolar fractures, there were 12 type Ⅱ fractures, 10 type Ⅲ fractures, and 4 type Ⅳ fractures. During operation, the fracture was exposed via the modified Rammelt transfibular approach; then, the fracture reduction was achieved under direct vision using techniques such as towel clip traction, posterolateral compression, and lifting with a posterior transverse periosteal elevator; finally, the fracture was fixed using anteroposterior cannulated screws or Kirschner wires. The incision healing was observed after operation. At 4 months after operation, X-ray film and CT were reviewed to evaluate the quality of fracture reduction. The medial clear space, tibiofibular clear space, and the anterior/posterior tibiofibular syndesmotic distances were measured. At last follow-up, the ankle function was assessed using the American Orthopaedic Foot & Ankle Society (AOFAS) score and the range of motion.
RESULTS:
The marginal necrosis occurred in 2 lateral malleolar incisions, and superficial infection occurred in 1 lateral malleolar incision; the remaining incisions healed by first intention. All 26 patients were followed up 13-21 months (mean, 15.6 months). X-ray films showed that fractures in 25 patients achieved clinical union within 3-8 months (mean, 5.4 months); 1 case had delayed union of the lateral malleolus. At 4 months after operation, no significant difference was found between the injured and healthy sides in the medial clear space, tibiofibular clear space, or the anterior/posterior tibiofibular syndesmotic distances ( P>0.05). No malreduction of the posterior malleolus or the tibiofibular syndesmosis occurred. At last follow-up, the AOFAS score ranged from 80 to 100 (mean, 91.9). The range of motion ranged from 17° to 22° (mean, 21.0°) in active ankle dorsiflexion and from 40° to 49° (mean, 44.6°) in plantar flexion. Internal fixator was removed in 12 patients at 1 year after operation, with no ankle instability occurring. Ankle joint degeneration was observed in 1 patient at last follow-up.
CONCLUSION
The modified Rammelt transfibular approach is a safe and reliable technique. It enables precise reduction under direct vision, improves the quality of reduction for the distal tibial articular surface and the tibiofibular syndesmosis, and provides satisfactory ankle functional recovery in short-term follow-up.
Humans
;
Male
;
Female
;
Adult
;
Ankle Fractures/diagnostic imaging*
;
Middle Aged
;
Retrospective Studies
;
Fracture Fixation, Internal/instrumentation*
;
Adolescent
;
Treatment Outcome
;
Young Adult
;
Bone Screws
;
Ankle Joint/surgery*
;
Fibula/surgery*
;
Range of Motion, Articular
8.Treatment options and research progress of proximal tibial extra-articular fractures.
Yuelei ZHANG ; Qi ZHANG ; Yuan LIN ; Yuandong FAN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(11):1485-1490
OBJECTIVE:
To review the main fixation methods for proximal tibial extra-articular fractures based on clinical and biomechanical results, and to provide evidence for clinical application.
METHODS:
Extensive related literature at home and abroad was conducted in recent years, and external fixation systems such as external fixation braces and external locking plates, as well as internal fixation systems such as plates and intramedullary nails, were systematically reviewed regarding their application indications, clinical efficacy, and biomechanical results in proximal tibial extra-articular fractures.
RESULTS:
External fixation systems have advantages in fractures with open or severe soft tissue injury, facilitating wound management and maintaining stability of the fracture site to some extent. However, in proximal tibial extra-articular fractures with good soft tissue conditions, internal fixation systems such as plates and intramedullary nails are still the first choice. Some studies have found that intramedullary nails allow patients to bear weight early, with shorter fracture healing time and higher rate of malunion, while other studies have found that both intramedullary nails and plates have similar clinical efficacy and can achieve satisfactory treatment results.
CONCLUSION
The choice of fixation method for proximal tibial extra-articular fractures depends not only on the type of fracture, but also on the surgeon's habits and operational skills. Larger-scale studies are still needed to clarify the advantages and disadvantages of intramedullary nails and locking plates in the treatment of proximal tibial extra-articular fractures.
Humans
;
Tibial Fractures/surgery*
;
Bone Plates
;
Fracture Fixation, Intramedullary/instrumentation*
;
Fracture Fixation, Internal/instrumentation*
;
Fracture Healing
;
External Fixators
;
Bone Nails
;
Fracture Fixation/instrumentation*
;
Treatment Outcome
;
Biomechanical Phenomena
9.Treatment of inferior pole patellar fractures with suture anchors and headless compression screws.
Junsong WANG ; Wei ZHANG ; Zhuang TIAN ; Yu JIANG ; Qi YAO
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(12):1521-1525
OBJECTIVE:
To evaluate the effectiveness of suture anchors combined with headless compression screw fixation in treating inferior pole patellar fractures.
METHODS:
A retrospective analysis was conducted on 36 patients with inferior pole patellar fractures, who were admitted between January 2018 and October 2024 and met the selective criteria. There were 15 males and 21 females with a mean age of 52.3 years (range, 23-81 years). The fracture were reduced and fixed using suture anchors combined with headless compression screws. The operation time, intraoperative blood loss, and the length of hospital stay were recorded. Functional recovery was assessed using knee range of motion (ROM), Hospital for Special Surgery (HSS) knee score, and Böstman patellar fracture efficacy score.
RESULTS:
The operation time ranged from 10 to 100 minutes, with an average of 57.6 minutes. The intraoperative blood loss was 10 to 120 mL, with an average of 73.3 mL. The length of hospital stay was 5 to 10 days, with an average of 6.3 days. All incisions healed by first intention. All 36 patients were followed up 18-24 months (mean, 20.6 months). Postoperative X-ray films indicated that the fractures had healed; no screw breakage, anchor loosening, or implant foreign body rejection reactions occurred during follow-up. At last follow-up, the ROM of the affected knee joint was (136.0±2.3)°, and there was no significant difference when compared with the healthy side (136.6±2.3)° ( t=-1.944, P=0.060). The HSS score of the affected knee joint was 96-100 (mean, 99.1), and all cases were rated as excellent. The Böstman patellar fracture efficacy score was 27-30 (mean, 29.1), and 35 cases were rated as excellent and 1 as good.
CONCLUSION
The suture anchors combined with headless compression screws technique provides reliable fixation for inferior pole patellar fractures. This method combines surgical simplicity with excellent functional outcomes.
Humans
;
Male
;
Female
;
Middle Aged
;
Bone Screws
;
Aged
;
Retrospective Studies
;
Patella/surgery*
;
Fracture Fixation, Internal/instrumentation*
;
Adult
;
Aged, 80 and over
;
Suture Anchors
;
Fractures, Bone/surgery*
;
Range of Motion, Articular
;
Treatment Outcome
;
Young Adult
;
Operative Time
;
Length of Stay
10.Clinical efficacy of open reduction and internal fixation with plates versus minimally invasive Kirschner wire fixation for osteoporotic Colles' fractures.
Jun-Wei ZHANG ; Jin-Yong HOU ; Zhao-Hui LI ; Zhen-Yuan MA ; Xiang GAO ; Hong-Zheng BI ; Ling-Ling CHEN ; Hai-Tao WANG ; Wei-Zhi NIE ; Yong-Zhong CHENG ; Xiao-Bing XI
China Journal of Orthopaedics and Traumatology 2025;38(1):18-24
OBJECTIVE:
To compare the short-term clinical efficacy and safety of closed reduction with Kirschner wire fixation versus open reduction with plate fixation for treating osteoporotic Colles' fractures in middle-aged and elderly patients.
METHODS:
Between January 2018 and January 2023, 119 patients with Colles fractures were retrospectively analyzed, including 39 males and 80 females, aged from 48 to 74 years old with an average of(60.58±6.71) years old. The time from injury to operation ranged 1 to 13 days with an average of (5.29±2.52) days. According to the surgical method, they were divided into Kirschner wire fixation group (Kirschner wire group) and plate internal fixation group (plate group). In Kirschner wire group, there were a total of 68 patients, comprising 21 males and 47 females. The average age was (61.15±6.24) years old, ranged from 49 to 74 years old. Among them, 41 cases involved the left side while 27 cases involved the right side. In the plate group, there were a total of 51 patients, including 18 males and 33 females. The average age was (59.78±5.71) years old ranged from 48 to 72 years old. Among them, there were 31 cases on the left side and 20 cases on the right side. The following parameters were recorded before and after the operation:operation time, intraoperative blood loss, hospitalization days, hospitalization expenses, postoperative complications, and radiographic parameters of distal radius (distal radius height, ulnar deviation angle, palmar tilt angle). The clinical efficacy was evaluated at 3 and 12 months after the operation using Gartland-Werley and disabilites of the arm shoulder and hand (DASH) scores.
RESULTS:
The patients in both groups were followed up for a duration from 12 to 19 months with an average of(13.32±2.02) months. The Kirschner wire group exhibited significantly shorter operation time compared to the plate group 27.91(13.00, 42.00) min vs 67.52(29.72, 105.32) min, Z=-8.74, P=0.00. Intraoperative blood loss was also significantly lower in the Kirschner wire group than in the plate group 3.24(1.08, 5.40) ml vs 21.91(17.38, 26.44) ml, Z=-9.31, P=0.00. Furthermore, patients in the Kirschner wire group had a shorter length of hospital stay compared to those in the plate group (8.38±2.63) days vs (11.40±2.78) days, t=-3.12, P=0.00. Additionally, hospitalization cost was significantly lower in the Kirschner wire group than in the plate group 10 111.29(6 738.98, 13 483.60) yuan vs 15 871.11(11 690.40, 20 051.82) yuan, Z=-5.62, P=0.00. The incidence of complications was 2 cases in the Kirschner wire group and 1 case in the plate group, with no statistically significant difference(P>0.05). At 3 months postoprative, the radial height of the Kirschner wire group was found to be significantly smaller than that of the plate group, with measurements of (11.45±1.69) mm and (12.11±1.78) mm respectively (t=-2.06, P=0.04). However, there were no statistically significant differences observed in ulnar deviation angle and palmar tilt angle between the two groups (P>0.05). The DASH score and Gartland-Werley score in the Kirschner group were significantly higher than those in the plate group at 3 months post-operation (19.10±9.89) vs (13.47±3.51), t=4.34, P=0.00;(11.15±3.61) vs (6.41±2.75), t=8.13, P=0.00). However, there was no significant difference between the two groups at 12 months post-operation (P>0.05).
CONCLUSION
Compared to plate internal fixation, closed reduction with Kirschner wire support fixation yields a slightly inferior recovery of radial height;however, there is no significant disparity in the functional score of the affected limb at 12 months post-operation. Nonetheless, this technique offers advantages such as shorter operation time, reduced intraoperative blood loss, decreased hospitalization duration, and lower cost.
Humans
;
Female
;
Male
;
Middle Aged
;
Aged
;
Fracture Fixation, Internal/instrumentation*
;
Bone Wires
;
Bone Plates
;
Retrospective Studies
;
Colles' Fracture/surgery*
;
Minimally Invasive Surgical Procedures/methods*
;
Open Fracture Reduction/methods*
;
Osteoporotic Fractures/surgery*

Result Analysis
Print