1.Deploying artificial intelligence in the detection of adult appendicular and pelvic fractures in the Singapore emergency department after hours: efficacy, cost savings and non-monetary benefits.
John Jian Xian QUEK ; Oliver James NICKALLS ; Bak Siew Steven WONG ; Min On TAN
Singapore medical journal 2025;66(4):202-207
INTRODUCTION:
Radiology plays an integral role in fracture detection in the emergency department (ED). After hours, when there are fewer reporting radiologists, most radiographs are interpreted by ED physicians. A minority of these interpretations may miss diagnoses, which later require the callback of patients for further management. Artificial intelligence (AI) has been viewed as a potential solution to augment the shortage of radiologists after hours. We explored the efficacy of an AI solution in the detection of appendicular and pelvic fractures for adult radiographs performed after hours at a general hospital ED in Singapore, and estimated the potential monetary and non-monetary benefits.
METHODS:
One hundred and fifty anonymised abnormal radiographs were retrospectively collected and fed through an AI fracture detection solution. The radiographs were re-read by two radiologist reviewers and their consensus was established as the reference standard. Cases were stratified based on the concordance between the AI solution and the reviewers' findings. Discordant cases were further analysed based on the nature of the discrepancy into overcall and undercall subgroups. Statistical analysis was performed to evaluate the accuracy, sensitivity and inter-rater reliability of the AI solution.
RESULTS:
Ninety-two examinations were included in the final study radiograph set. The AI solution had a sensitivity of 98.9%, an accuracy of 85.9% and an almost perfect agreement with the reference standard.
CONCLUSION
An AI fracture detection solution has similar sensitivity to human radiologists in the detection of fractures on ED appendicular and pelvic radiographs. Its implementation offers significant potential measurable cost, manpower and time savings.
Humans
;
Singapore
;
Emergency Service, Hospital
;
Fractures, Bone/diagnostic imaging*
;
Artificial Intelligence
;
Retrospective Studies
;
Adult
;
Male
;
Female
;
Cost Savings
;
Middle Aged
;
Pelvic Bones/diagnostic imaging*
;
Reproducibility of Results
;
Aged
;
Sensitivity and Specificity
;
Radiography
2.Application of intermediate screw assisted reduction and fixation technique in treatment of Schatzker type Ⅴ and Ⅵ tibial plateau fractures.
Zhaodong WANG ; Keyou DUAN ; Yajun LIU ; Chen XU ; Zhonglian ZHU ; Pinghui ZHOU ; Jianzhong GUAN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(5):529-535
OBJECTIVE:
To explore effectiveness of intermediate screw assisted reduction and fixation technique in the treatment of Schatzker type Ⅴ and Ⅵ tibial plateau fractures.
METHODS:
A clinical data of 22 patients with Schatzker type Ⅴ and Ⅵ tibial plateau fractures, who were admitted between June 2022 and December 2023 and met the selection criteria, was retrospectively analyzed. During operation, the intermediate screw assisted reduction and fixation technique was used. There were 14 males and 8 females with an average age of 46.3 years (range, 17-65 years). The fractures were caused by traffic accident in 13 cases, by falls in 5 cases, and by falling from height in 4 cases. According to Schatzker classification criteria, 9 cases were type Ⅴ and 13 cases were type Ⅵ. The interval between injury and operation was 5-12 days (mean, 7.9 days). The operation time, intraoperative fluoroscopy times, and length of hospital stay were recorded. The range of motion of knee joint and Hospital for Special Surgery (HSS) score were recorded at last follow-up. X-ray films were taken to review the fracture healing. Rasmussen score, tibial plateau varus angle (TPVA), and posterior tibial slope (PTS) were estimated before operation, at immediate after operation, and at last follow-up in order to evaluate the fracture reduction effect and postoperative outcome.
RESULTS:
The operation time was 85-140 minutes (mean, 103.9 minutes). Intraoperative fluoroscopy was performed 7-15 times (mean, 10.1 times). All incisions healed by first intention after operation, and no complication such as nerve or blood vessel injury occurred. The length of hospital stay ranged from 8 to 17 days (mean, 12.4 days). All patients were followed up 10-22 months (mean, 14.8 months). At last follow-up, the range of motion of knee joint was 110°-140° (mean, 125°). HSS score was rated as excellent in 16 cases, good in 5 cases, and fair in 1 case, with an excellent and good rate of 95.5%. X-ray films reexamination showed that all fractures healed with the healing time of 12-17 weeks (mean, 14.8 weeks). No internal fixation failure occurred. Rasmussen score, TPVA, and PTS at immediate after operation and at last follow-up were significantly superior to those before operation ( P<0.05). And there was no significant difference between immediately after operation and last follow-up ( P>0.05).
CONCLUSION
The treatment of Schatzker type Ⅴ and Ⅵ tibial plateau fractures with intermediate screw assisted reduction and fixation technique is reliable, which can reduce the difficulty of reduction and fixation, improve the efficiency of reduction and fixation, reduce the operation time, achieve satisfactory reduction and fixation effect and postoperative prognosis, and achieve good recovery of knee joint function.
Humans
;
Tibial Fractures/diagnostic imaging*
;
Male
;
Female
;
Adult
;
Middle Aged
;
Bone Screws
;
Fracture Fixation, Internal/instrumentation*
;
Retrospective Studies
;
Adolescent
;
Aged
;
Young Adult
;
Treatment Outcome
;
Range of Motion, Articular
;
Operative Time
;
Length of Stay
;
Tibial Plateau Fractures
3.Treatment of irreducible intertrochanteric femoral fracture in elderly with proximal femoral nail antirotation combined with minimally invasive clamp reduction technique by Kocher pincers.
Hongwei TANG ; Yong YIN ; Yinhua MA
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(5):536-541
OBJECTIVE:
To explore the effectiveness of proximal femoral nail antirotation (PFNA) combined with minimally invasive clamp reduction technique by Kocher pincers in the treatment of irreducible intertrochanteric femoral fracture in the elderly.
METHODS:
The clinical data of 35 elderly patients with irreducible intertrochanteric femoral fractures who were treated with PFNA combined with minimally invasive clamp reduction technique by Kocher pincers between January 2016 and December 2022 were retrospectively analysed. There were 16 males and 19 females, aged from 63 to 95 years (mean, 75.2 years). The causes of injury included traffic accident in 3 cases and falling in 32 cases. The time from injury to operation was 2-11 days (mean, 3.6 days). According to AO/Orthopaedic Trauma Association (AO/OTA) classification system for intertrochanteric fractures, there were 14 cases of type A1, 18 cases of type A2, and 3 cases of type A3. According to the displacement of fracture by intraoperative fluoroscopy, there were 5 cases with only coronal displacement, 17 cases with only sagittal displacement, and 13 cases with both coronal and sagittal displacement. The operation time, intraoperative blood loss, rate of hemoglobin decline at 1 day after operation, length of hospital stay, and fracture healing time were recorded. The reduction quality of fracture during operation was evaluated according to reduction quality criteria proposed by Chang et al. The Harris scoring system was used to evaluate the hip joint function at last follow-up.
RESULTS:
The operation time was 45-105 minutes (mean, 54.4 minutes); the intraoperative blood loss was 80-300 mL (mean, 116.3 mL). The reduction quality of fracture during operation was good in 22 cases (62.9%) and acceptable in 13 cases (37.1%). The rate of hemoglobin decline at 1 day after operation ranged from 6.2% to 18.6% (mean, 10.2%); the length of hospital stay was 5-18 days (mean, 7.2 days). One case died of respiratory failure due to pulmonary infection, 2 cases were lost to follow-up, and the remaining 32 cases were followed up 6-24 months (mean, 10.6 months). All 32 patients achieved bony union and the healing time was 3-9 months (mean, 3.6 months). There was no complication such as incision infection, internal fixation failure, or coxa varus during follow-up. At last follow-up, the Harris score of hip joint was 67-96 (mean, 88.9); among them, 19 cases were excellent, 10 cases were good, 2 cases were fair, and 1 case was poor, with an excellent and good rate of 90.6%.
CONCLUSION
For the elderly patients with irreducible intertrochanteric femoral fracture, the application of PFNA combined with minimally invasive clamp reduction technique by Kocher pincers can achieve high-quality fracture reduction, which has the advantages of simple reduction operation, less trauma, and can avoid the radiation exposure of operators during maintenance reduction.
Humans
;
Male
;
Female
;
Aged
;
Minimally Invasive Surgical Procedures/methods*
;
Hip Fractures/diagnostic imaging*
;
Bone Nails
;
Aged, 80 and over
;
Retrospective Studies
;
Fracture Fixation, Intramedullary/instrumentation*
;
Middle Aged
;
Treatment Outcome
;
Fracture Fixation, Internal/instrumentation*
;
Fracture Healing
;
Femoral Fractures/surgery*
4.Finite element analysis of adding one transverse screw for Pauwels type Ⅲ femoral neck fractures.
Luyao MA ; Xueao SUN ; Qingjun TAN ; Yanping LAN ; Xiaohu WANG ; Yunsheng YIN ; Jinhui MA
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(5):584-591
OBJECTIVE:
To investigate whether adding 1 transverse screw (TS) to the triangular parallel cannulated screw (TPCS) fixation has a mechanical stability advantage for Pauwels type Ⅲ femoral neck fractures by conducting finite element analysis on four internal fixation methods.
METHODS:
Based on CT data of a healthy adult male volunteer's femur, three Pauwels type Ⅲ femoral neck fracture models (Pauwels angle 70°, Pauwels angle 80°, and Pauwels angle 70° combined with bone defect) were constructed using Mimics 21.0 software and SolidWorks 2017 software. Four different internal fixation models were built at the same time, including TPCS, TPCS+TS, three cross screws (TCS), and TPCS+medial buttress plate (MBP). The mechanical stability of different models under the same load was compared by finite element analysis.
RESULTS:
The femoral model established in this study exhibited a maximum stress of 28.62 MPa, with relatively higher stress concentrated in the femoral neck. These findings were comparable to previous studies, indicating that the constructed femoral finite element model was correct. The maximum stress of internal fixation in finite element analysis showed that TCS was the lowest and TPCS+MBP was the highest in Pauwels angle 70° and 80° models, while TPCS+TS was the lowest and TCS was the highest in Pauwels angle 70° combined with bone defect model. The maximum displacement of internal fixation in each fracture model was located at the top of the femoral head, with TCS having the highest maximum displacement of the femur. The maximum stress of fracture surface in finite element analysis showed that TCS was the lowest and TPCS was the highest in the Pauwels angle 70° model, while TPCS+MBP was the lowest and TPCS/TCS were the highest in the Pauwels angle 80° model and the Pauwels angle 70° combined with bone defect model, respectively. The maximum displacement of fracture surfece analysis showed that TPCS+MBP was the lowest and TCS was the highest in Pauwels angle 70° and 80° models, while TPCS+TS was the lowest and TCS was the highest in Pauwels angle 70° combined with bone defect model.
CONCLUSION
For Pauwels type Ⅲ femoral neck fractures, the biomechanical stability of TPCS+TS was superior to that of TPCS alone and TCS, but it has not yet reached the level of TPCS+MBP.
Finite Element Analysis
;
Humans
;
Femoral Neck Fractures/diagnostic imaging*
;
Bone Screws
;
Fracture Fixation, Internal/instrumentation*
;
Male
;
Bone Plates
;
Stress, Mechanical
;
Biomechanical Phenomena
;
Tomography, X-Ray Computed
;
Adult
;
Femur Neck/surgery*
5.Effectiveness analysis of tension band-assisted fixation for volar marginal fractures of distal radius.
Abulimiti MIREADELI ; Wanming QU ; Tianbo ZHU ; Daoxin ZHANG ; Xiaokang ZHU ; Xinzhi LI ; Wenyao CHEN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(6):662-667
OBJECTIVE:
To investigate the surgical technique and effectiveness of tension band-assisted plate fixation combined with external fixator for volar marginal fractures of the distal radius.
METHODS:
A retrospective analysis was performed on the clinical data of 12 patients with volar marginal fractures of the distal radius treated by Kirschner wire tension band-assisted anatomical plate fixation combined with external fixator between October 2018 and July 2023. The cohort included 9 males and 3 females, aged from 20 to 52 years (mean, 35.5 years). The injury causes included traffic accidents in 6 cases, falls from height in 3 cases, and fall in 3 cases. According to AO/Orthopaedic Trauma Association (AO/OTA), there were 1 case of type B2, 4 cases of type B3, 2 cases of type C1, 3 cases of type C2, and 2 cases of type C3. According to Fernandez classification, there were 2 cases of type Ⅲ, 5 cases of type Ⅳ, and 5 cases of type Ⅴ. Associated injuries included radiocarpal joint dislocation or subluxation in 7 cases and median nerve injury in 2 cases. The time from injury to operation was 2-7 days (mean, 3.2 days). Postoperatively, functional outcomes were evaluated using the modified Mayo wrist score and the Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire. Grip strength was measured as the ratio to the unaffected side, and wrist range of motion (ROM) including dorsiflexion, palmar flexion, ulnar deviation, and radial deviation was assessed.
RESULTS:
All procedures were successfully completed, with an operation time of 55-110 minutes (mean, 65 minutes). All patients were followed up 6-36 months (mean, 13.7 months). Surgical incisions healed by first intention, without complications such as vascular-nerve injury or infection. Bony union and articular congruency were attained in all patients, with a healing time of 3-5 months (mean, 3.8 months). During follow-up, 1 case of Kirschner wire migration occurred with no instances of infections, radiocarpal dislocations, internal fixation failures, or extensor pollicis longus tendon ruptures. At last follow-up, the modified Mayo wrist score ranged from 65 to 92 (mean, 80.8), the DASH score ranged from 7 to 15 (mean, 11.6), the grip strength was 65%-90% (mean, 78.2%) of the unaffected side; and wrist ROM was palmar flexion 60°-85° (mean, 77.4°), dorsiflexion 55°-80° (mean, 74.8°), radial deviation 10°-25° (mean, 18.8°), and ulnar deviation 15°-30° (mean, 24.5°).
CONCLUSION
Kirschner wire tension band-assisted anatomical plate fixation combined with external fixator for volar marginal fractures of the distal radius is a simple method with reliable fixation, which can achieve satisfactory effectiveness.
Humans
;
Male
;
Adult
;
Female
;
Radius Fractures/diagnostic imaging*
;
Retrospective Studies
;
Middle Aged
;
Bone Plates
;
Bone Wires
;
External Fixators
;
Young Adult
;
Fracture Fixation, Internal/instrumentation*
;
Treatment Outcome
;
Range of Motion, Articular
;
Hand Strength
;
Wrist Injuries/surgery*
6.Analysis of effectiveness of Holosight robot navigation-assisted percutaneous cannulated screw fixation in treatment of femoral neck fractures.
Weizhen XU ; Zhenqi DING ; Hui LIU ; Jinhui ZHANG ; Yuanfei XIONG ; Jin WU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(6):673-679
OBJECTIVE:
To investigate the effectiveness of Holosight robotic navigation-assisted percutaneous cannulated screw fixation for femoral neck fractures.
METHODS:
A retrospective analysis was conducted on 65 patients with femoral neck fractures treated with cannulated screw fixation between January 2022 and February 2024. Among them, 31 patients underwent robotic navigation-assisted screw placement (navigation group), while 34 underwent conventional freehand percutaneous screw fixation (freehand group). Baseline characteristics, including age, gender, fracture side, injury mechanism, Garden classification, Pauwels classification, and time from injury to operation, showed no significant differences between the two groups ( P>0.05). The operation time, intraoperative blood loss, fluoroscopy frequency, fracture healing time, and complications were recorded and compared, and hip function was evaluated by Harris score at last follow-up. Postoperative anteroposterior and lateral hip X-ray films were taken to assess screw distribution accuracy, including deviation from the femoral neck axis, inter-screw parallelism, and distance from screws to the femoral neck cortex.
RESULTS:
No significant difference was observed in operation time between the two groups ( P>0.05). However, the navigation group demonstrated superior outcomes in intraoperative blood loss, fluoroscopy frequency, deviation from the femoral neck axis, inter-screw parallelism, and distance from screws to the femoral neck cortex ( P<0.05). No incision infections or deep vein thrombosis occurred. All patients were followed up 12-18 months (mean, 16 months). In the freehand group, 1 case suffered from cannulated screw dislodgement and nonunion secondary to osteonecrosis of femoral head at 1 year after operation, 1 case suffered from screw penetration secondary to osteonecrosis of femoral head at 5 months after operation; and 1 case suffered from nonunion secondary to osteonecrosis of femoral head at 6 months after operation in the navigation group. All the 3 patients underwent internal fixators removal and total hip arthroplasty. There was no significant difference in the incidence of complications between the two groups ( P>0.05). The fracture healing time and hip Harris score at last follow-up in the navigation group were significantly better than those in the freehand group ( P<0.05).
CONCLUSION
Compared to freehand percutaneous screw fixation, Holosight robotic navigation-assisted cannulated screw fixation for femoral neck fractures achieves higher precision, reduced intraoperative radiation exposure, smaller incisions, and superior postoperative hip function recovery.
Humans
;
Femoral Neck Fractures/diagnostic imaging*
;
Bone Screws
;
Fracture Fixation, Internal/instrumentation*
;
Male
;
Female
;
Retrospective Studies
;
Robotic Surgical Procedures/methods*
;
Middle Aged
;
Aged
;
Adult
;
Treatment Outcome
;
Operative Time
;
Fracture Healing
;
Surgery, Computer-Assisted/methods*
;
Fluoroscopy
7.Clinical and therapeutic analysis of 22 patients with traumatic spinopelvic dissociation.
Min WU ; Jianzhong GUAN ; Xiaotian CHEN ; Xiaopan WANG ; Peishuai ZHAO ; Yongsheng WANG ; Jiaqiang CHEN ; Leyu LIU ; Renjie LI
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(6):692-700
OBJECTIVE:
To review the clinical characteristics of patients with traumatic spinopelvic dissociation (SPD) and explore the diagnostic and therapeutic methods.
METHODS:
A clinical data of 22 patients with SPD who underwent surgical treatment between March 2019 and August 2024 was retrospectively analyzed. There were 13 males and 9 females, with an average age of 35.5 years (range, 14-61 years). The causes of injury included falling from height in 16 cases, traffic accidents in 5 cases, and compression injury in 1 case. Sacral fractures were classified based on morphology into "U" type (9 cases), "H" type (7 cases), "T" type (4 cases), and "λ" type (2 cases). According to the Roy-Camille classification, there were 4 cases of type Ⅰ, 12 cases of type Ⅱ, 2 cases of type Ⅲ, and 4 cases of type Ⅳ. The Cobb angle was (35.7± 22.0)°. Sixteen patients were accompanied by lumbosacral trunk and cauda equina nerve injury, which was classified as grade Ⅱ in 5 cases, grade Ⅲ in 5 cases, and grade Ⅳ in 6 cases according to the Gibbons grading. The time from injury to operation was 2-17 days (mean, 5.7 days). Based on the type of sacral fracture and sacral nerve injury, 6 cases were treated with closed reduction and minimally invasive percutaneous sacroiliac screw fixation, 16 cases were treated with open reduction and lumbar iliac fixation (8 cases)/triangular fixation (8 cases). Among them, 11 patients with severe fracture displacement and kyphotic deformity leading to sacral canal stenosis or bony impingement within the sacral foramen underwent laminectomy and sacral nerve decompression. X-ray films and CT were reviewed during followed-up. The Matta score was used to evaluate the quality of fracture reduction. At last follow-up, the Majeed score was used to assess the functional recovery, and the Gibbons grading was used to evaluate the nerve function.
RESULTS:
All operations were successfully completed. All patients were followed up 8-64 months (mean, 20.4 months). Two patients developed deep vein thrombosis of the lower limbs, 2 had incision infections, and 1 developed a sacral pressure ulcer; no other complications occurred. Radiological examination showed that the Cobb angle was (12.0±6.8)°, which was significantly different from the preoperative one ( t=6.000, P<0.001). The Cobb angle in 16 patients who underwent open reduction was (14.9±5.5)°, which was significantly different from the preoperative one [(46.8±13.9)° ] ( t=8.684, P<0.001). According to the Matta scoring criteria, the quality of fracture reduction was rated as excellent in 8 cases, good in 7 cases, fair in 5 cases, and poor in 2 cases, with an excellent and good rate of 68.2%. Bone callus formation was observed at the fracture site in all patients at 12 weeks after operation, and bony union achieved in all cases at last follow-up, with a healing time ranging from 12 to 36 weeks (mean, 17.6 weeks). At last follow-up, the Majeed score was rated as excellent in 7 cases, good in 10 cases, fair in 4 cases, and poor in 1 case, with an excellent and good rate of 77.3%. One patient experienced a unilateral iliac screw breakage at 12 months after operation, but the fracture had already healed, and there was no loss of reduction. Among the 16 patients with preoperative sacral nerve injury, 11 cases showed improvement in nerve function (6 cases) or recovery (5 cases).
CONCLUSION
SPD with low incidence, multiple associated injuries, and high incidence of sacral nerve injury, requires timely decompression of the sacral canal for symptomatic sacral nerve compression, fractures reduction, deformities correction, and stable fixation.
Humans
;
Adult
;
Female
;
Male
;
Retrospective Studies
;
Middle Aged
;
Spinal Fractures/diagnostic imaging*
;
Adolescent
;
Sacrum/diagnostic imaging*
;
Fracture Fixation, Internal/methods*
;
Young Adult
;
Pelvic Bones/surgery*
;
Treatment Outcome
;
Bone Screws
8.Antegrade elastic intramedullary nailing fixation via a novel approach through proximal radius for distal radius metaphyseal-diaphyseal junction fractures in children.
Bin JIN ; Xinglei SHI ; Hailong MA ; Junchen ZHU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(9):1155-1159
OBJECTIVE:
To investigate the surgical technique and preliminary effectiveness of closed reduction and internal fixation (CRIF) using antegrade elastic intramedullary nailing (ESIN) via a novel approach through the proximal radius for treating distal radius metaphyseal-diaphyseal junction (DRMDJ) fractures in children.
METHODS:
A retrospective analysis was conducted on 34 children with DRMDJ fractures who met the selection criteria and were treated between January 2020 and June 2023. There were 21 boys and 13 girls, aged 6-14 years (mean, 8.2 years). Injury causes included falls in 11 cases and sports-related trauma in 23 cases. Twenty-six cases were associated with ipsilateral distal ulnar fractures. All patients had failed initial closed reduction in the outpatient clinic. The time from injury to operation ranged from 1 to 15 days (mean, 4 days). All patients underwent CRIF using antegrade ESIN inserted via a novel approach at the proximal one-third of the radius. The operation time, intraoperative fluoroscopy frequency, fracture healing time, and complications were recorded. Fracture reduction was assessed immediately after operation on anteroposterior and lateral X-ray films for residual translation and angulation. Wrist function was evaluated using the modified Mayo wrist score.
RESULTS:
Surgery was successfully completed in all 34 children. CRIF with ESIN failed in 2 cases with associated ipsilateral distal ulnar fractures, requiring conversion to open reduction of the ulna. Operation time ranged from 15 to 56 minutes (mean, 21 minutes). Intraoperative fluoroscopy frequency ranged from 5 to 21 times (mean, 7 times). Immediate postoperative X-ray films showed residual translation of 0-15% on anteroposterior view and 0-10% on lateral view, and residual angulation of 0°-5° on both anteroposterior and lateral views. All children were followed up 6-18 months (mean, 12 months). There was no complication such as neurovascular injury, incision infection, or limitation of forearm rotation. Follow-up X-ray films showed no fracture displacement, implant loosening, delayed union, or nonunion. Fracture healing time ranged from 4 to 8 weeks (mean, 6 weeks). Implants were removed at 4-6 months postoperatively (mean, 5 months). At last follow-up, all fractures had achieved anatomic or near-anatomic healing. The modified Mayo wrist score ranged from 80 to 100 (mean, 94), with 27 excellent and 7 good results, yielding an excellent and good rate of 100%.
CONCLUSION
CRIF using antegrade ESIN via a novel approach through proximal radius is a safe and effective treatment for pediatric DRMDJ fractures, associated with few postoperative complications and excellent restoration of wrist function.
Humans
;
Child
;
Female
;
Male
;
Fracture Fixation, Intramedullary/instrumentation*
;
Adolescent
;
Radius Fractures/diagnostic imaging*
;
Retrospective Studies
;
Bone Nails
;
Treatment Outcome
;
Fracture Healing
;
Diaphyses/surgery*
;
Radius/surgery*
;
Operative Time
;
Closed Fracture Reduction/methods*
;
Ulna Fractures/surgery*
9.Effectiveness of double joystick technique assisted treatment of Gartland type Ⅲ supracondylar fractures of the humerus in children.
Guangyao LI ; Feng HU ; He BAI ; Wei LIU ; Dandan HAN ; Quangui CHEN ; Shaolin TAN ; Ke SHA
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(9):1160-1164
OBJECTIVE:
To evaluate the effectiveness of double joystick technique assisted closed reduction and Kirschner wire internal fixation in the treatment of Gartland type Ⅲ supracondylar fractures of the humerus (SCFH) in children.
METHODS:
A retrospective study was conducted on 28 cases of Gartland type Ⅲ SCFH with complete data available, who underwent closed reduction and Kirschner wire internal fixation with the double joystick technique between August 2022 and July 2024. There were 23 boys and 5 girls, with an average age of 6.4 years (range, 1-12 years). All fractures resulted from falls and were classified as extension-type. X-ray film showed the radial displacement of the distal fragment in 15 cases and unlar displacement in 13 cases. The interval from injury to operation was 3-36 hours (mean, 19.5 hours). X-ray film re-examination was conducted to evaluate the fracture healing, and the Baumann angle of affected elbow joint and carrying angle of bilateral elbow joints were measured. Elbow joint function was evaluated using the range of motion (flexion and extension) and the Flynn criteria. The above indicators were compared between affected and healthy sides.
RESULTS:
All operation were successfully completed. The operation time ranged from 15 to 40 minutes (mean, 25.2 minutes). The length of hospital stay was 2-5 days (mean, 3.5 days). All patients were followed up 3-24 months (mean, 11.8 months). X-ray film confirmed fracture healing in all patients, with a mean healing time of 5.4 weeks (range, 4-6 weeks). At last follow-up, the Baumann angle of the affected elbow joint was (73.50±3.46)°, and the carrying angle and the range of motion in flexion and extension of the affected elbow joint were significantly less than the contralateral side (P<0.05). According to the Flynn criteria, the elbow joint function of the affected elbow was evaluated as excellent in 25 cases and good in 3 cases, with an excellent and good rate of 100%.
CONCLUSION
The double joystick technique is a safe and effective method which can facilitate the closed reduction and Kirschner wire internal fixation of Gartland type Ⅲ SCFH in children without increasing risk of complications.
Humans
;
Male
;
Female
;
Humeral Fractures/diagnostic imaging*
;
Fracture Fixation, Internal/instrumentation*
;
Child
;
Retrospective Studies
;
Bone Wires
;
Child, Preschool
;
Fracture Healing
;
Treatment Outcome
;
Infant
;
Elbow Joint/physiopathology*
;
Range of Motion, Articular
;
Closed Fracture Reduction/methods*
10.Measurement and clinical validation of safe distance for LC- Ⅱ screw placement using iliac oblique view.
Hongwei FU ; Ansu WANG ; Lin CHEN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(10):1304-1309
OBJECTIVE:
To define a safe distance range from the LC-Ⅱ screw trajectory to the apex of the greater sciatic notch based on pelvic CT measurements, and to clinically assess the feasibility of using this range under iliac oblique view combined with iliac tangential view fluoroscopy to guide screw insertion.
METHODS:
CT scans of 104 normal pelvises collected between January 2022 and February 2025 were analyzed. There were 52 males and 52 females, with a median age of 45.8 years (range, 19-76 years). The RadiAnt DICOM Viewer software was used to reconstruct coronal, sagittal, and axial sections of the potential LC-Ⅱ screw trajectory. The maximum safety distance (Dmax) and the optimal safety distance (Dopt) from this trajectory to the greater sciatic notch were measured on the coronal and sagittal views. A retrospective analysis was conducted on 21 patients with LC-Ⅱ type pelvic fractures treated with the LC-Ⅱ screws fixation. And the screws were placed within the pre-defined safe distance under guidance from the iliac oblique view and iliac tangential view. Postoperative CT scans were obtained to evaluate the accuracy of screw placement.
RESULTS:
Radiographic measurements from the 104 cases showed that Dmax ranged from 1.87 to 3.87 cm (mean, 2.79 cm), and Dopt ranged from 1.01 to 2.92 cm (mean, 1.84 cm). Both Dmax and Dopt were significantly greater in the males than in the females ( P>0.05). No significant difference was found between the left and right sides within the same gender ( P>0.05). All 21 patients successfully underwent fracture reduction and fixation, with a total of 23 LC-Ⅱscrews implanted. According to the Lonstein grading system, the screw placement accuracy was rated as excellent in 16 screws, good in 3, fair in 3, and poor in 1, with an excellent and good rate of 82.6%.
CONCLUSION
Utilizing a CT-defined safe distance range from the screw trajectory to the greater sciatic notch, and adhering to this range under iliac oblique view combined with iliac tangential view fluoroscopy, enables the accurate and precise placement of LC-Ⅱ screws.
Humans
;
Male
;
Female
;
Middle Aged
;
Bone Screws
;
Adult
;
Tomography, X-Ray Computed/methods*
;
Aged
;
Ilium/surgery*
;
Pelvic Bones/diagnostic imaging*
;
Fracture Fixation, Internal/instrumentation*
;
Retrospective Studies
;
Fluoroscopy
;
Fractures, Bone/diagnostic imaging*
;
Young Adult

Result Analysis
Print
Save
E-mail