1.Axial biomechanical performance evaluation of locally-developed modular external fixator.
Jan Francois B. Severo ; Miguel Sandino O. Aljibe ; Anjenina U. Durana ; Jason Pechardo ; Dionella Jitka B. Quinagoran ; Eduardo R. Magdaluyo Jr. ; Emmanuel P. Estrella
Acta Medica Philippina 2026;60(9):25-32
BACKGROUND
In the Philippines and other developing countries, access to high-stability external fixators for traumainduced bone fracture management is limited, as modular external fixators, especially those with snap-on features, are manufactured overseas and are prohibitively expensive for most Filipino patients.
OBJECTIVEThis study aimed to assess the biomechanical performance of a locally-developed modular external fixator prototype for tibial diaphyseal fractures in comparison to available external fixators, such as Roger Anderson and Hoffmann. This provides an initial evaluation for the use of the external fixator as an alternative in terms of its stability.
METHODSUsing axial compression testing compliant with the ASTM F1541-24 standards, the ultimate strength, yield strength, safe strength, and stiffness were measured across various fixator types and tightening mechanisms, with or without the aid of a wrench. Statistical tools such as the t-test assuming equal variances, one-way analysis of variance, and Tukey-Kramer test with a 0.05 level of significance were used to determine any significant differences.
RESULTSThe mechanical performance of the external fixator prototype increased by a factor of 1.5 to 2.5 after the clamps were tightened with the wrench. However, when hand-tightened, it still performed sufficiently, showing a comparable mechanical performance with the Roger Anderson Fixator. In terms of the ultimate, safe, and yield strengths, it performed competitively in comparison with the Hoffmann system. However, there is a significant difference in stiffness between the prototype and the Hoffmann system.
CONCLUSIONThe locally-developed external fixator was comparable biomechanically to the commercially available external fixators and the prototypes in different studies.
Evaluation Studies As Topic ; Developing Countries ; External Fixators ; Fractures, Bone ; Philippines ; Patients
2.Automatic Bone Fracture Reduction Technique with Section Registration.
Qinhui YUAN ; Mengxing LIU ; Chu GUO ; Yukun AN ; Ping ZHOU
Chinese Journal of Medical Instrumentation 2025;49(1):1-7
As a fundamental aspect of bone fracture treatment, fracture reduction plays a decisive role in restoring the structural integrity and function of bones. At present, fracture reduction techniques mostly rely on semi-automatic interaction methods or healthy-side bone templates for registration, which have many limitations in clinical practice. In order to enhance treatment efficiency and accuracy, an automatic fracture reduction algorithm is proposed. This algorithm utilizes the similarity of fracture cross-sections for registration, thereby reducing the workload of physicians and eliminating the need for a healthy-side bone template. Initially, the closed edge is identified and extracted by analyzing the differences in the fracture surface and the calorific value diagram of the roughness distribution. Next, the fracture section is determined by using the identified closed edge as a guideline for regional expansion and similarity matching. During the registration phase, the iterative closest point (ICP) algorithm is highly sensitive to distance. Therefore, the geometric features of point clouds are incorporated into the objective function of the registration algorithm to mitigate the influence of noise, and fracture section registration is implemented one by one. Finally, the algorithm is tested and compared on 180 simulated datasets and 16 publicly available datasets. The results show that the proposed algorithm significantly improves the registration accuracy, and the registration error of clinical bone fracture cases is controlled within 1.7 mm.
Algorithms
;
Fractures, Bone/therapy*
;
Humans
3.Comparison of the efficacy of simultaneous and staged surgical procedures for traumatic nasal bone fractures with septal fractures.
Yi DONG ; Shengsheng LI ; Suibin MA ; Huijun HAN
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2025;39(4):338-343
Objective:To compare the outcomes of simultaneous versus staged nasal bone reduction and septoplasty in the treatment of traumatic nasal bone fractures with associated septal fractures. Methods:Patients with traumatic nasal bone fractures, with or without septal fractures, were recruited from two hospitals and divided into three groups. Group A underwent simultaneous nasal bone reduction and septoplasty, Group B underwent staged nasal bone reduction and septoplasty, and Group C underwent nasal bone reduction only. Nasal appearance scores and nasal congestion Visual Analogue Scale (VAS) scores were measured preoperatively, at 2 weeks postoperatively, and at 3 months postoperatively. For Group B, scores were also recorded at 2 weeks and 3 months after the second-stage surgery. Differences were analyzed using statistical software. Results:Two weeks post-surgery, the nasal appearance scores significantly decreased in all three groups compared to preoperative scores (P< 0.01), with no statistically significant differences between the groups (P= 0.43, 0.71, 0.58). In Group A, the VAS score for nasal congestion decreased significantly following simultaneous surgery (P<0.01). In Group B, there were no significant differences in nasal congestion VAS scores between pre-surgery and post-first-stage, nor between three months post-first-stage and two weeks post-first-stage (P= 0.61, 0.13). However, the VAS scores significantly decreased after the second-stage surgery compared to pre-surgery, and three months post-second-stage surgery compared to three months post-first-stage surgery (P<0.01). The VAS scores for nasal congestion at two weeks post-surgery in Group A were lower than those in Group B after the first-stage surgery (P<0.01). The incidence rates of nasal adhesions post-surgery in Groups A, B, and C were 0%, 6.9%, and 4.3%, respectively. Conclusion:For traumatic nasal bone fractures with associated septal fractures, performing simultaneous nasal bone reduction and septoplasty under general anesthesia using endoscopy is more time-efficient compared to staged surgery, and it results in a lower occurrence rate of post-surgical nasal adhesions.
Humans
;
Nasal Bone/surgery*
;
Nasal Septum/injuries*
;
Treatment Outcome
;
Rhinoplasty/methods*
;
Male
;
Female
;
Adult
;
Skull Fractures/surgery*
;
Fractures, Bone/surgery*
;
Middle Aged
;
Adolescent
4.Effect of intraoperative ultrasound-guided nasal fracture repair on postoperative child satisfaction and nasal function.
Chunmiao LI ; Ying LI ; Dongjie SENG ; Ying XU ; Zejuan JI
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2025;39(6):559-563
Objective:To investigate the effect of intraoperative ultrasound-guided nasal bone fracture repair on the clinical outcome of pediatric patients with nasal bone fracture. Methods:A total of 83 patients with nasal bone fracture who underwent prosthesis in our hospital from June 2022 to March 2024 were selected and assigned to control group (endoscopic nasal bone fracture repair) and experimental group (ultrasound-guided nasal bone fracture repair) using random number table method. Both groups were treated with the same nursing measures after surgery. There were 41 cases in the control group and 42 cases in the experimental group. The evaluation parameters of nasal bone fracture, nasal ventilation function, nasal appearance and olfactory function score, postoperative complications and satisfaction were compared between the two groups. Results:The operation time and hospital stay were significantly lower in the experimental group than in the control group (P<0.05), and secondary repair case (n=0) in the experimental group was significantly less than in the control group (P<0.05). Compared to preoperative status, the minimum nasal cross-sectional area, nasal volume and total nasal expiratory volume of the two groups increased three months post-operatively, and those in the experimental group were higher (P<0.05), nasal expiratory and inspiratory resistance, nasal appearance and olfactory disorder scores decreased and those in the experimental group were lower (P<0.05). The postoperative complications incidence in the experimental group was lower than in the control group (7.14% and 14.63%, respectively, P>0.05). The overall satisfaction in the experimental group was higher than in the control group(90.48% and 82.93%, respectively, P>0.05). Conclusion:Ultrasound-guided nasal fracture repair can effectively shorten the operation time, improve the success rate, and promote the postoperative recovery of nasal appearance and nasal function, reduce complications, and enhance the overall satisfaction of children and their families.
Humans
;
Nasal Bone/surgery*
;
Patient Satisfaction
;
Child
;
Female
;
Male
;
Postoperative Complications
;
Treatment Outcome
;
Postoperative Period
;
Fractures, Bone/surgery*
;
Ultrasonography
5.The epidemiology and distribution of hand fractures in Singapore.
Jin Xi LIM ; Lan Anh Thi LE ; Jared Ze Yang YEH ; Jia Jun Justin BOEY ; Vaikunthan RAJARATNAM
Singapore medical journal 2025;66(9):476-480
INTRODUCTION:
The aim of this study was to elucidate the epidemiology and distribution of hand fractures in Singapore.
METHODS:
A total of 701 hand fractures in 596 patients aged 21 years and above from a single centre were reviewed from 2010 to 2011. Details regarding the patient demographics, occupation, mechanism of injury, associated injuries and treatment were obtained.
RESULTS:
Hand fractures were particularly significant in patients between the ages of 21 and 40 years 58.9% of the total cases. The relative risk of hand fractures in males was 5.5 times greater than that in females. The majority of hand fractures occurred at the workplace (47.7%), with crush injury being the main mechanism of injury (33.6%). The most common locations of hand fracture were the little finger ray (31.2%) and distal phalanges (37.7%). There were 170 cases that underwent surgical fixation, which accounted for 24.3% of all fractures. Fixation rate was similar for both closed and open fractures but was significantly higher in the proximal and middle phalanges compared to the distal phalanx and metacarpal ( P < 0.001). With regards to surgical fixation methods, wires were commonly used in either tuft fractures (100.0%) or intra-articular fractures (69.9%), whereas plates and screws were commonly used in shaft fractures (65.5%).
CONCLUSION
The most significant population that sustained hand fractures in Singapore are young to middle-aged males who are skilled manual workers. The most commonly involved ray and location of hand fractures are the little finger ray and the distal phalanges, respectively, as they are in a relatively more exposed location.
Humans
;
Singapore/epidemiology*
;
Male
;
Female
;
Adult
;
Middle Aged
;
Fractures, Bone/surgery*
;
Hand Injuries/surgery*
;
Young Adult
;
Aged
;
Hand Bones/injuries*
;
Retrospective Studies
;
Fracture Fixation, Internal
6.Deploying artificial intelligence in the detection of adult appendicular and pelvic fractures in the Singapore emergency department after hours: efficacy, cost savings and non-monetary benefits.
John Jian Xian QUEK ; Oliver James NICKALLS ; Bak Siew Steven WONG ; Min On TAN
Singapore medical journal 2025;66(4):202-207
INTRODUCTION:
Radiology plays an integral role in fracture detection in the emergency department (ED). After hours, when there are fewer reporting radiologists, most radiographs are interpreted by ED physicians. A minority of these interpretations may miss diagnoses, which later require the callback of patients for further management. Artificial intelligence (AI) has been viewed as a potential solution to augment the shortage of radiologists after hours. We explored the efficacy of an AI solution in the detection of appendicular and pelvic fractures for adult radiographs performed after hours at a general hospital ED in Singapore, and estimated the potential monetary and non-monetary benefits.
METHODS:
One hundred and fifty anonymised abnormal radiographs were retrospectively collected and fed through an AI fracture detection solution. The radiographs were re-read by two radiologist reviewers and their consensus was established as the reference standard. Cases were stratified based on the concordance between the AI solution and the reviewers' findings. Discordant cases were further analysed based on the nature of the discrepancy into overcall and undercall subgroups. Statistical analysis was performed to evaluate the accuracy, sensitivity and inter-rater reliability of the AI solution.
RESULTS:
Ninety-two examinations were included in the final study radiograph set. The AI solution had a sensitivity of 98.9%, an accuracy of 85.9% and an almost perfect agreement with the reference standard.
CONCLUSION
An AI fracture detection solution has similar sensitivity to human radiologists in the detection of fractures on ED appendicular and pelvic radiographs. Its implementation offers significant potential measurable cost, manpower and time savings.
Humans
;
Singapore
;
Emergency Service, Hospital
;
Fractures, Bone/diagnostic imaging*
;
Artificial Intelligence
;
Retrospective Studies
;
Adult
;
Male
;
Female
;
Cost Savings
;
Middle Aged
;
Pelvic Bones/diagnostic imaging*
;
Reproducibility of Results
;
Aged
;
Sensitivity and Specificity
;
Radiography
7.Biomechanical analysis of three kinds of rigid internal fixation methods for condylar head fractures.
Junhui SUN ; Duoduo LAN ; Dong WANG ; Yao XU ; Zeyu WANG ; Chenchen ZHANG ; Kai ZHANG ; Tao XU
West China Journal of Stomatology 2025;43(1):126-132
OBJECTIVES:
This study aims to analyze the biomechanics of three kinds of rigid internal fixation methods for condylar head fractures.
METHODS:
A three dimensional finite element model of the normal mandible was constructed. It was then used to prepare condylar head fracture finite element model and three kinds of rigid internal fixation finite element model (unilateral tension screw, bilateral tension screw, tension screw+titanium plate). The mechanical characteristics and changes of the mandible condyle under the same mechanical conditions were compared among the three different rigid internal fixation methods.
RESULTS:
The maximum equivalent stress and displacement of the non-free end of condyle under the rigid internal fixation method of unilateral tension screw were 71.03 MPa and 4.72 mm, respectively. The maximum equivalent stress and displacement of the free end of condyle were 78.45 MPa and 4.50 mm, respectively. The maximum stress of fracture suture was 3.27 MPa. The maximum equivalent stress and displacement of the non-free end of condyle under the rigid internal fixation method of bilateral tension screw were 70.52 MPa and 4.00 mm, respectively. The maximum equivalent stress and displacement of the free end of condyle were 72.49 MPa and 3.85 mm, respectively. The maximum stress of fracture suture was 2.33 MPa. The maximum equivalent stress and maximum displacement of the non-free end of condyle under the rigid internal fixation method of tension screw+titanium plate were 67.26 MPa and 2.66 mm, respectively. The maximum equivalent stress and maximum displacement of the free end of condyle were 69.66 MPa and 2.50 mm, respectively. The maximum stress of fracture suture was 2.18 MPa.
CONCLUSIONS
The tension screw+titanium plate rigid internal fixation method is the most conducive to biomechanical distribution for condylar head fractures.
Fracture Fixation, Internal/instrumentation*
;
Mandibular Condyle/surgery*
;
Biomechanical Phenomena
;
Bone Screws
;
Finite Element Analysis
;
Humans
;
Mandibular Fractures/surgery*
;
Bone Plates
;
Titanium
;
Stress, Mechanical
8.Efficacy and Safety of Systemic Thrombolysis in the Treatment of Lower Extremity Fracture Complicated With Distal Deep Vein Thrombosis.
Shi-Qiang LIAO ; Shu-Ming SHI ; Qiang ZHANG ; Chuan-Yong LI ; Guang-Feng ZHENG ; Zhi-Chang PAN ; Jian-Jie RONG
Acta Academiae Medicinae Sinicae 2025;47(2):237-243
Objective To evaluate the efficacy and safety of systemic thrombolysis(ST)and standard anticoagulation(SA)in the treatment of lower extremity fracture complicated with distal deep vein thrombosis(DDVT).Methods We retrospectively analyzed the clinical data of 60 patients with lower extremity fracture complicated with DDVT treated from January 2021 to December 2023.When the lower limb venography indicated a calf thrombus burden score ≥3 points,a retrievable inferior vena cava filter(IVCF)was successfully placed in the healthy femoral vein before orthopedic surgery.The patients who received further anticoagulant or thrombolytic therapy after surgery were allocated into a ST group(n=30,urokinase ST and SA)and a SA group(n=30,only SA).The two groups were compared in terms of calf thrombus burden score,thrombus dissolution rate,IVCF placement time,IVCF retrieval rate,intercepted thrombi,hemoglobin level,platelet count,D-dimer level,and complications.Results There was no statistically significant difference in the calf thrombus burden score between the two groups before treatment(P=0.431).However,after treatment,the scores in both groups decreased(both P<0.001),with the ST group showing lower score than the SA group(P=0.002).The thrombus dissolution rate in the ST group was higher than that in the SA group(P<0.001).There was no statistically significant difference in the IVCF placement time between the two groups(P=0.359),and the IVCF retrieval rate was 100% in both groups.The ST group had fewer intercepted thrombi than the SA group(P=0.002).There was no statistically significant difference in hemoglobin level(P=0.238),platelet count(P=0.914),or D-dimer level(P=0.756)between the two groups before treatment.However,after treatment,both groups showed an increase in platelet count(both P<0.001)and a decrease in D-dimer level(both P<0.001).There was no statistically significant difference in the occurrence of complications between the two groups(P=0.704).Conclusions Both SA and ST demonstrate safety and efficacy in the treatment of lower extremity fractures complicated with DDVT,serving as valuable options for clinical application.Compared with SA,ST not only enhances the thrombus dissolution in the calf but also mitigates the risk of thrombosis associated with IVCF.
Humans
;
Venous Thrombosis/therapy*
;
Retrospective Studies
;
Thrombolytic Therapy/methods*
;
Male
;
Female
;
Middle Aged
;
Fractures, Bone/complications*
;
Lower Extremity/injuries*
;
Anticoagulants/therapeutic use*
;
Aged
;
Treatment Outcome
;
Adult
9.Biomechanical study on wing shaped titanium plate fixation of acetabular anterior column and posterior hemi-transverse fracture under multiple working conditions.
Jianwu ZHANG ; WURIKAIXI AIYITI ; Gang LYU ; MAIMAIAILI YUSHAN ; Zhiqiang MA ; Chao MA
Journal of Biomedical Engineering 2025;42(2):351-358
This article aims to compare and analyze the biomechanical differences between wing-shaped titanium plates and traditional titanium plates in fixing acetabular anterior column and posterior hemi-transverse (ACPHT) fracture under multiple working conditions using the finite element method. Firstly, four sets of internal fixation models for acetabular ACPHT fractures were established, and the hip joint stress under standing, sitting, forward extension, and abduction conditions was calculated through analysis software. Then, the stress of screws and titanium plates, as well as the stress and displacement of the fracture end face, were analyzed. Research has found that when using wing-shaped titanium plates to fix acetabular ACPHT fractures, the peak stress of screws decreases under all working conditions, while the peak stress of wing-shaped titanium plates decreases under standing and sitting conditions and increases under forward and outward extension conditions. The relative displacement and mean stress of the fracture end face decrease under all working conditions, but the values are higher under forward and outward extension conditions. Wing-shaped titanium plates can reduce the probability of screw fatigue failure when fixing acetabular ACPHT fractures and can bear greater loads under forward and outward extension conditions, improving the mechanical stability of the pelvis. Moreover, the stress on the fracture end surface is more conducive to stimulating fracture healing and promoting bone tissue growth. However, premature forward and outward extension rehabilitation exercises should not be performed.
Titanium
;
Bone Plates
;
Humans
;
Acetabulum/surgery*
;
Fracture Fixation, Internal/methods*
;
Biomechanical Phenomena
;
Finite Element Analysis
;
Bone Screws
;
Fractures, Bone/surgery*
;
Stress, Mechanical
;
Working Conditions
10.TiRobot-assisted minimally invasive treatment of coracoid process fractures of scapula.
Yonghong DAI ; Qingyu LI ; Yanhui ZENG ; Zhengjie WU ; Chunpeng ZHAO ; Junqiang WANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):40-46
OBJECTIVE:
To explore effectiveness of TiRobot-assisted screw implantation in the treatment of coracoid process fractures of the scapula.
METHODS:
A retrospective analysis was conducted on the clinical data from 24 patients with coracoid process fractures of the scapula admitted between September 2019 and January 2024 and met selection criteria. Among them, 12 patients underwent TiRobot-assisted screw implantation (robot group) and 12 underwent manual screw implantation (control group) during internal fixation. There was no significant difference ( P>0.05) in baseline data such as gender, age, body mass index, disease duration, cause of injury, coracoid process fracture classification, and proportion of patients with associated injuries between the two groups. The incision length, operation time, intraoperative blood loss, hospital stay, accuracy of screw placement, coracoid process fracture healing time, and complications were recorded and compared, as well as pain visual analogue scale (VAS) score, and Constant-Murley score at last follow-up.
RESULTS:
The intraoperative blood loss and incision length in the robot group were significantly lower than those in the control group ( P<0.05); however, there was no significant difference in operation time and hospital stay between the two groups ( P>0.05). All patients were followed up 8-27 months (mean, 17.5 months), and the difference in follow-up time between the two groups was not significant ( P>0.05). At last follow-up, the VAS score for shoulder pain in the robot group was signifncatly lower compared to the control group, and the Constant-Murley score was significantly higher ( P<0.05). In the robot group, 16 screws were implanted intraoperatively, while 13 screws were implanted in the control group. Radiographic re-evaluation showed that the excellent and good rate of screw implantation was higher in the robot group (93.8%, 15/16) than in the control group (61.5%, 8/13), but the difference in the precision of screw implantation between the two groups was not significant ( P>0.05). Four patients in the robot group and 1 in the control group achieved double screws fixation; however, the difference in achieving double screws fixation between the two groups was not significant ( P>0.05). All fractures healed in both groups with 1 case of malunion in the control group. There was no significant difference in healing time between the two groups ( P>0.05). During follow-up, 1 patient in the control group experienced screw loosening and displacement. There was no significant difference in the incidence of screw loosening and fracture malunion between the two groups ( P>0.05).
CONCLUSION
Compared with manual screw implantation, TiRobot-assisted minimally invasive treatment of coracoid process fractures of the scapula can reduce intraoperative blood loss, shorten incision length, alleviate pain, and obtain better promote shoulder joint functional recovery.
Humans
;
Male
;
Female
;
Retrospective Studies
;
Fracture Fixation, Internal/instrumentation*
;
Minimally Invasive Surgical Procedures/instrumentation*
;
Adult
;
Middle Aged
;
Fractures, Bone/surgery*
;
Bone Screws
;
Coracoid Process/surgery*
;
Robotic Surgical Procedures/methods*
;
Scapula/surgery*
;
Treatment Outcome
;
Operative Time
;
Young Adult
;
Length of Stay
;
Blood Loss, Surgical


Result Analysis
Print
Save
E-mail