1.TiRobot-assisted minimally invasive treatment of coracoid process fractures of scapula.
Yonghong DAI ; Qingyu LI ; Yanhui ZENG ; Zhengjie WU ; Chunpeng ZHAO ; Junqiang WANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):40-46
OBJECTIVE:
To explore effectiveness of TiRobot-assisted screw implantation in the treatment of coracoid process fractures of the scapula.
METHODS:
A retrospective analysis was conducted on the clinical data from 24 patients with coracoid process fractures of the scapula admitted between September 2019 and January 2024 and met selection criteria. Among them, 12 patients underwent TiRobot-assisted screw implantation (robot group) and 12 underwent manual screw implantation (control group) during internal fixation. There was no significant difference ( P>0.05) in baseline data such as gender, age, body mass index, disease duration, cause of injury, coracoid process fracture classification, and proportion of patients with associated injuries between the two groups. The incision length, operation time, intraoperative blood loss, hospital stay, accuracy of screw placement, coracoid process fracture healing time, and complications were recorded and compared, as well as pain visual analogue scale (VAS) score, and Constant-Murley score at last follow-up.
RESULTS:
The intraoperative blood loss and incision length in the robot group were significantly lower than those in the control group ( P<0.05); however, there was no significant difference in operation time and hospital stay between the two groups ( P>0.05). All patients were followed up 8-27 months (mean, 17.5 months), and the difference in follow-up time between the two groups was not significant ( P>0.05). At last follow-up, the VAS score for shoulder pain in the robot group was signifncatly lower compared to the control group, and the Constant-Murley score was significantly higher ( P<0.05). In the robot group, 16 screws were implanted intraoperatively, while 13 screws were implanted in the control group. Radiographic re-evaluation showed that the excellent and good rate of screw implantation was higher in the robot group (93.8%, 15/16) than in the control group (61.5%, 8/13), but the difference in the precision of screw implantation between the two groups was not significant ( P>0.05). Four patients in the robot group and 1 in the control group achieved double screws fixation; however, the difference in achieving double screws fixation between the two groups was not significant ( P>0.05). All fractures healed in both groups with 1 case of malunion in the control group. There was no significant difference in healing time between the two groups ( P>0.05). During follow-up, 1 patient in the control group experienced screw loosening and displacement. There was no significant difference in the incidence of screw loosening and fracture malunion between the two groups ( P>0.05).
CONCLUSION
Compared with manual screw implantation, TiRobot-assisted minimally invasive treatment of coracoid process fractures of the scapula can reduce intraoperative blood loss, shorten incision length, alleviate pain, and obtain better promote shoulder joint functional recovery.
Humans
;
Male
;
Female
;
Retrospective Studies
;
Fracture Fixation, Internal/instrumentation*
;
Minimally Invasive Surgical Procedures/instrumentation*
;
Adult
;
Middle Aged
;
Fractures, Bone/surgery*
;
Bone Screws
;
Coracoid Process/surgery*
;
Robotic Surgical Procedures/methods*
;
Scapula/surgery*
;
Treatment Outcome
;
Operative Time
;
Young Adult
;
Length of Stay
;
Blood Loss, Surgical
2.Comparison of effectiveness between two surgical methods for humeral lateral condyle fractures in children.
Hailong MA ; Qingjie WU ; Fang LIU ; Zhongtuo HUA ; Sicheng ZHANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):64-69
OBJECTIVE:
To compare the effectiveness of ultrasound-guided closed reduction with Kirschner wire fixation and open reduction with Kirschner wire fixation in the treatment of humeral lateral condyle fracture (HLCF) in children.
METHODS:
A clinical data of 53 children with HLCF admitted between May 2020 and April 2023 and met selective criteria was retrospectively analyzed. Of these, 25 cases were managed with closed reduction and Kirschner wire fixation under ultrasound guidance (closed group), while 28 cases underwent open reduction and Kirschner wire fixation (open group). There was no significant difference between the two groups in terms of gender, age, cause of injury, fracture side, fracture classification, and time from injury to operation ( P>0.05). The following variables were recorded and compared between the two groups: operation time, intraoperative fluoroscopy frequency, fracture healing time, incidence of complications, and the Flynn elbow function score at last follow-up.
RESULTS:
In the closed group, the fractures were successfully reduced under ultrasound guidance, with no nerve damage reported in either group. The operation time and intraoperative fluoroscopy frequency were significantly less in the closed group than in the open group ( P<0.05). One case of infection (Kirschner wire irritation) was observed in the closed group, while 3 cases in the open group (2 of Kirschner wire irritation and 1 of incision infection). However, the difference in the incidence of infection between the two groups was not significant ( P>0.05). All patients in both groups were followed up 6-18 months (mean, 10.2 months). X-ray examinations confirmed that fractures had healed in both groups, with no significant difference in healing time ( P>0.05). During follow-up, 5 cases of lateral humeral process formation were observed in the closed group, compared to 12 cases in the open group, although this difference was not significant ( P>0.05). At last follow-up, the excellent and good rate of elbow joint function was evaluated as 96.0% (24/25) in the closed group and 92.9% (26/28) in the open group according to the Flynn scoring criteria, with no significant difference between the two groups ( P>0.05). Both groups showed no occurrence of ossifying myositis or elbow internal/external rotation.
CONCLUSION
The effectiveness of ultrasound-guided closed reduction and Kirschner wire fixation in the treatment of HLCF in children is comparable to open reduction and Kirschner wire fixation, but the former can reduce operation time and intraoperative fluoroscopy frequency, and obtain lower the incidence of complications.
Humans
;
Humeral Fractures/diagnostic imaging*
;
Bone Wires
;
Male
;
Female
;
Child
;
Retrospective Studies
;
Fracture Fixation, Internal/instrumentation*
;
Treatment Outcome
;
Child, Preschool
;
Open Fracture Reduction/methods*
;
Fracture Healing
;
Elbow Joint/surgery*
;
Adolescent
;
Closed Fracture Reduction/methods*
;
Fluoroscopy
;
Operative Time
3.Posterior minimally invasive approach for treatment of posterior wall acetabular fractures.
Wenbo LI ; Lihong LIU ; Peisheng SHI ; Yun XUE ; Wei WANG ; Jie SHI ; Chuangbing LI ; Xianqing SHI ; Xiaowen DENG ; Qiuming GAO
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(2):134-139
OBJECTIVE:
To investigate the effectiveness of posterior minimally invasive approach in the treatment of posterior wall acetabular fractures.
METHODS:
The clinical data of 17 patients with posterior wall acetabular fractures treated with posterior minimally invasive approach between March 2019 and June 2023 were retrospectively analyzed. There were 14 males and 3 females with an average age of 41 years ranging from 28 to 57 years. The causes of injury were traffic accident in 12 cases and falling from height in 5 cases. There were 3 cases complicated with posterior hip dislocation and 2 cases complicated with sciatic nerve injury. According to AO/Orthopaedic Trauma Association (AO/OTA) classification, there were 11 cases of type A1.1 and 6 cases of type A1.2. The time from injury to operation was 5-8 days, with an average of 6.2 days. The incision length, intraoperative blood loss, and operation time were recorded. The quality of posterior wall fracture reduction were evaluated by Matta criteria, and hip function were evaluated by modified Merle d'Aubign-Postel score criteria at 6 months after operation and last follow-up.
RESULTS:
The operation was successfully completed in 17 cases. The length of incision ranged from 7 to 9 cm, with an average of 8.3 cm, and all incisions healed by first intention. The intraoperative blood loss ranged from 200 to 350 mL, with an average of 281 mL. The operation time ranged from 45 to 70 minutes, with an average of 57 minutes. Two patients had sciatic nerve injury before operation, and the sciatic nerve function recovered completely at 3 months after operation; the other 15 patients had no symptoms of sciatic nerve injury after operation. All the 17 patients were followed up 14-27 months, with an average of 19.5 months. At 1 week after operation, according to the Matta criteria, anatomical reduction was achieved in 12 cases and satisfactory reduction in 5 cases, with a satisfaction rate of 100%. According to the modified Merle d'Aubign-Postel scoring system, the hip function score was 13-18 (mean, 16.1) at 6 months after operation. Among them, 5 cases were excellent, 9 were good, and 3 were fair, with an excellent and good rate of 82.4%. At last follow-up, the hip function score was 7-18 (mean, 13.7), of which 3 cases were excellent, 9 were good, 3 were fair, and 2 were poor, with an excellent and good rate of 70.6%. During the follow-up, there was no infection, failure of internal fixation, and femoral head necrosis, and heterotopic ossification occurred in 2 cases.
CONCLUSION
The posterior minimally invasive approach has the advantages of less trauma, shorter operation time, less blood loss, without cutting off the external rotator muscle. Exposure through the gluteus medius-piriformis space and piriformis-supercilium space can provide sufficient safe exposure for the posterior wall acetabulum fracture, which is a reliable alternative approach for the posterior acetabular fracture.
Humans
;
Acetabulum/surgery*
;
Male
;
Female
;
Adult
;
Middle Aged
;
Minimally Invasive Surgical Procedures/methods*
;
Retrospective Studies
;
Fracture Fixation, Internal/instrumentation*
;
Fractures, Bone/diagnostic imaging*
;
Treatment Outcome
;
Operative Time
4.Clinical study of reverse total shoulder arthroplasty versus open reduction and internal plate fixation for treatment of Neer three/four-part proximal humeral fractures in elderly.
Yuhui YANG ; Zhantao DENG ; Qingtian LI ; Xiurui ZHANG ; Yunzhi PENG ; Ruiying ZHANG ; Yuanchen MA ; Qiujian ZHENG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(4):412-419
OBJECTIVE:
To compare the effectiveness and shoulder function of reverse total shoulder arthroplasty (RTSA) and open reduction and internal fixation (ORIF) in the treatment of Neer three/four-part proximal humeral fractures in the elderly.
METHODS:
Randomized controlled analysis was conducted on 68 patients over 70 years old with Neer three/four-part proximal humeral fractures treated with RTSA or ORIF between January 2020 and June 2022. The patients were randomly divided into RTSA group ( n=32) and ORIF group ( n=36). There was no significant difference ( P>0.05) in the baseline data such as age, gender, body mass index, injured side, Neer classification, and preoperative Charlson comorbidity index, visual analogue scale (VAS) score, Constant shoulder score, Oxford shoulder score (OSS), and hemoglobin (Hb). The operation time, intraoperative blood loss, reduction of Hb on the 3rd day after operation, hospital stay, total cost of hospitalization, complication incidence, range of motion of shoulder joint at 2 years after operation, VAS score before operation and at 5 days and 1 month after operation, Constant shoulder score and OSS score before operation and at 2 years after operation, and imaging results during follow-up were recorded and compared between the two groups.
RESULTS:
Compared with the ORIF group, the RTSA group had longer operation time, less intraoperative blood loss, and higher total cost of hospitalization ( P<0.05). There was no significant difference in Hb reduction on the 3rd day after operation between the two groups ( P>0.05). The VAS scores significantly improved in both groups at 5 days and 1 month after operation ( P<0.05), but there was no significant difference between the two groups ( P>0.05). All patients were followed up 26-35 months, with an average of 31.2 months. In the RTSA group, there were 2 cases of poor healing of superficial incision and 1 case of transient nerve injury. There was no complication such as bone resorption around the prosthesis, lucent band, prosthesis loosening, or periprosthetic fracture in all patients. In the ORIF group, there was 1 case of poor healing of superficial incision, 3 cases of nonunion of fracture, 1 case of arthritis secondary to humeral head necrosis, and 1 case of bone absorption of large tuberosity, and no displacement or fracture failure of internal fixation was found in all patients. There was no significant difference in the incidence of complications [9.4% (3/32) vs 16.7% (6/36)] between the two groups [ OR (95% CI): 0.828 (0.171, 4.014), P=0.814]. In the RTSA group, 28 cases were graded 0 and 4 cases were graded 1 at 2 years after operation. Constant and OSS scores of RTSA group were significantly better than those of ORIF group ( P<0.05). The Constant score was significantly better than ORIF group in activity and strength, range of motion, lifting, abduction, and external rotation ( P<0.05), and there was no significant difference in pain, daily function, and internal rotation between the two groups ( P>0.05). The RTSA group had a significantly greater range of motion in lifting, abduction, and external rotation than ORIF group ( P<0.05), but there was no significant difference in internal rotation between the two groups ( P>0.05).
CONCLUSION
Application of RTSA as the initial treatment of Neer three/four-part proximal humeral fractures in the elderly can achieve better rehabilitation of joint activity and lower risk of early reoperation, and improve the quality of life of elderly fracture patients. However, the difficulty of revision and the high cost of treatment require the surgeon to pay full attention and strictly grasp the indications.
Humans
;
Fracture Fixation, Internal/instrumentation*
;
Male
;
Female
;
Shoulder Fractures/surgery*
;
Arthroplasty, Replacement, Shoulder/methods*
;
Aged
;
Bone Plates
;
Open Fracture Reduction/methods*
;
Range of Motion, Articular
;
Treatment Outcome
;
Shoulder Joint/physiopathology*
;
Aged, 80 and over
;
Operative Time
;
Postoperative Complications/epidemiology*
;
Length of Stay
5.Treatment of anterior cruciate ligament tibial avulsion fracture involving anterior root of lateral meniscus with wire anchor nailing composite double pulley technique.
Kunming YANG ; Xinmin WANG ; Han WANG ; Guoshuai LIU ; Bing LI ; Yuxi BAI ; Fei LIU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(4):440-445
OBJECTIVE:
To investigate the effectiveness of knee arthroscopy with wire anchor nailing composite double pulley technique in the treatment of anterior cruciate ligament (ACL) tibial avulsion fracture involving the anterior root of the lateral meniscus (LM).
METHODS:
Clinical data of 35 patients with ACL tibial avulsion fracture involving the anterior root of the LM admitted between January 2019 and September 2023 and met the selection criteria were retrospectively analysed. There were 20 males and 15 females; ages ranged from 10 to 57 years, with a mean of 29 years. The time from injury to surgery ranged from 3 to 20 days, with a mean of 9.6 days. Meyers-McKeever classification included 5 cases of type Ⅱ, 12 cases of type Ⅲ, and 18 cases of type Ⅳ. Preoperative anterior knee instability Lachman test and anterior drawer test were positive. The anterior root of the LM as well as the avulsion fracture block were fixed using suture anchor nails compounded with double pulley technique under arthroscopy. Postoperative X-ray films were performed to assess fracture healing; knee stability was assessed using the anterior drawer test and Lachman test, anterior laxity of the knee was measured by KT-2000, and knee function was assessed using the Lysholm score and the International Knee Documentation Committee (IKDC) score; at last follow-up, the recovery of the meniscus was assessed using the McMurry test and knee hyperextension test.
RESULTS:
All the patients were successfully operated, the operation time ranged from 56 to 78 minutes,with an average of 67.6 minutes, and there was no nerve or blood vessel injury during operation. Thirty-five cases were followed up 12-18 months with an average of 15.1 months. During the follow-up, there was no infection, knee stiffness, loosening of internal fixation, fracture displacement, or re-fracture. The fractures all healed, with a clinical healing time of 8-15 weeks, averaging 10.9 weeks. At last follow-up, 4 patients had weakly positive anterior drawer test and Lachman test, and the rest were negative; McMurry test and knee hyperextension test were negative; no patient complained of knee extension pain or straightening obstacles, and all the patients resumed their normal life or sports and labour; 16 patients with unclosed epiphyses did not have any epiphyseal injuries or growth disorders. Lysholm score, IKDC score, and KT-2000 anterior knee laxity at last follow-up significantly improved when compared with preoperative ones ( P<0.05).
CONCLUSION
The treatment of ACL tibial avulsion fracture involving the anterior root of the LM with suture anchor composite double pulley technique can effectively fix the anterior root of the LM while fixing the avulsion fracture block, and better restore the function and stability of the knee joint.
Humans
;
Male
;
Female
;
Adult
;
Arthroscopy/methods*
;
Adolescent
;
Retrospective Studies
;
Tibial Fractures/surgery*
;
Young Adult
;
Middle Aged
;
Fractures, Avulsion/surgery*
;
Fracture Fixation, Internal/instrumentation*
;
Anterior Cruciate Ligament Injuries/surgery*
;
Child
;
Treatment Outcome
;
Suture Anchors
;
Menisci, Tibial/surgery*
;
Tibial Meniscus Injuries/surgery*
;
Bone Nails
;
Knee Joint/surgery*
6.Treatment of irreducible intertrochanteric femoral fracture in elderly with proximal femoral nail antirotation combined with minimally invasive clamp reduction technique by Kocher pincers.
Hongwei TANG ; Yong YIN ; Yinhua MA
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(5):536-541
OBJECTIVE:
To explore the effectiveness of proximal femoral nail antirotation (PFNA) combined with minimally invasive clamp reduction technique by Kocher pincers in the treatment of irreducible intertrochanteric femoral fracture in the elderly.
METHODS:
The clinical data of 35 elderly patients with irreducible intertrochanteric femoral fractures who were treated with PFNA combined with minimally invasive clamp reduction technique by Kocher pincers between January 2016 and December 2022 were retrospectively analysed. There were 16 males and 19 females, aged from 63 to 95 years (mean, 75.2 years). The causes of injury included traffic accident in 3 cases and falling in 32 cases. The time from injury to operation was 2-11 days (mean, 3.6 days). According to AO/Orthopaedic Trauma Association (AO/OTA) classification system for intertrochanteric fractures, there were 14 cases of type A1, 18 cases of type A2, and 3 cases of type A3. According to the displacement of fracture by intraoperative fluoroscopy, there were 5 cases with only coronal displacement, 17 cases with only sagittal displacement, and 13 cases with both coronal and sagittal displacement. The operation time, intraoperative blood loss, rate of hemoglobin decline at 1 day after operation, length of hospital stay, and fracture healing time were recorded. The reduction quality of fracture during operation was evaluated according to reduction quality criteria proposed by Chang et al. The Harris scoring system was used to evaluate the hip joint function at last follow-up.
RESULTS:
The operation time was 45-105 minutes (mean, 54.4 minutes); the intraoperative blood loss was 80-300 mL (mean, 116.3 mL). The reduction quality of fracture during operation was good in 22 cases (62.9%) and acceptable in 13 cases (37.1%). The rate of hemoglobin decline at 1 day after operation ranged from 6.2% to 18.6% (mean, 10.2%); the length of hospital stay was 5-18 days (mean, 7.2 days). One case died of respiratory failure due to pulmonary infection, 2 cases were lost to follow-up, and the remaining 32 cases were followed up 6-24 months (mean, 10.6 months). All 32 patients achieved bony union and the healing time was 3-9 months (mean, 3.6 months). There was no complication such as incision infection, internal fixation failure, or coxa varus during follow-up. At last follow-up, the Harris score of hip joint was 67-96 (mean, 88.9); among them, 19 cases were excellent, 10 cases were good, 2 cases were fair, and 1 case was poor, with an excellent and good rate of 90.6%.
CONCLUSION
For the elderly patients with irreducible intertrochanteric femoral fracture, the application of PFNA combined with minimally invasive clamp reduction technique by Kocher pincers can achieve high-quality fracture reduction, which has the advantages of simple reduction operation, less trauma, and can avoid the radiation exposure of operators during maintenance reduction.
Humans
;
Male
;
Female
;
Aged
;
Minimally Invasive Surgical Procedures/methods*
;
Hip Fractures/diagnostic imaging*
;
Bone Nails
;
Aged, 80 and over
;
Retrospective Studies
;
Fracture Fixation, Intramedullary/instrumentation*
;
Middle Aged
;
Treatment Outcome
;
Fracture Fixation, Internal/instrumentation*
;
Fracture Healing
;
Femoral Fractures/surgery*
7.Comparative study of posterior axillary edge approach and arthroscopic assisted reduction in treatment of Ideberg type Ⅰ and Ⅱglenoid fracture of the scapula.
Bing LI ; Yanhong YUAN ; Peng XU ; Yabing YUAN ; Yuchen WANG ; Xingzhou ZHANG ; Zhangning HE
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(5):556-562
OBJECTIVE:
To compare the effectiveness of posterior axillary edge approach and arthroscopic assisted reduction in the treatment of Ideberg type Ⅰ and Ⅱ glenoid fracture of the scapula.
METHODS:
The clinical data of 26 patients with fresh Ideberg type Ⅰ and Ⅱ scapular fractures admitted between June 2021 and September 2024 who met the selection criteria were analyzed retrospectively. The patients were divided into two groups according to different treatment methods. Ten cases in the posterior axillary edge group were fixed by open reduction plate through the posterior axillary edge approach, and 16 cases in the arthroscopy group were treated with suture anchor fixation under arthroscopy. There was no significant difference in baseline data between the two groups ( P>0.05), such as gender, age, surgical side, Ideberg type, cause of injury, time from injury to operation, rotator cuff injury, and superior labrum anterior posterior (SLAP) injury, etc. The operation time and fracture healing time were recorded and compared between the two groups, and the shoulder pain was evaluated by visual analogue scale (VAS) score at 1 week, 1 month, and 3 months after operation. At 3 and 6 months after operation, the range of motion of shoulder joint in anteflexion, abduction, external rotation, internal rotation, and backward extension was evaluated, the upper limb dysfunction was evaluated by the Disability Assessment Scale of Arm, Shoulder, and Hand (DASH), and the shoulder joint function was evaluated by the Constant-Murley score. The differences between 6 months and 3 months after operation (changes) were statistically analyzed.
RESULTS:
Patients in both groups were followed up 11-13 months, with an average of 12.5 months. The operation time and fracture healing time in the posterior axillary edge group were significantly shorter than those in the arthroscopy group ( P<0.05). There was no complication such as wound infection, vascular and nerve injury, loss of reduction, bone nonunion, or glenohumeral instability in both groups. At 1 week after operation, the VAS score in the posterior axillary edge group was significantly higher than that in the arthroscopy group ( P<0.05); there was no significant difference in the VAS score between the two groups at 1 and 3 months after operation ( P>0.05). At 6 months after operation, the changes of shoulder joint in anteflexion, internal rotation range of motion and DASH scores in the posterior axillary edge group were significantly lower than those in the arthroscopy group ( P<0.05), while the changes of abduction, external rotation, backward extension range of motion and Constant-Murley scores were not significantly different between the two groups ( P>0.05).
CONCLUSION
For Ideberg type Ⅰ and Ⅱ glenoid fracture of the scapula, the posterior axillary edge approach for internal fixation has a short operation time, fast fracture healing, and is beneficial for early functional recovery; arthroscopic assisted reduction has minimal trauma and can handle joint injuries simultaneously. Both surgical procedures are safe and effective, and individualized selection should be made based on soft tissue conditions and combined injuries.
Humans
;
Arthroscopy/methods*
;
Scapula/surgery*
;
Male
;
Female
;
Retrospective Studies
;
Adult
;
Fracture Fixation, Internal/instrumentation*
;
Fractures, Bone/surgery*
;
Middle Aged
;
Treatment Outcome
;
Bone Plates
;
Suture Anchors
;
Fracture Healing
;
Range of Motion, Articular
;
Young Adult
;
Shoulder Joint/surgery*
;
Operative Time
8.Impact of surgical timing on effectiveness of closed reduction and percutaneous Kirschner wire fixation for pediatric supracondylar humerus fractures.
Tianlong PAN ; Xianghua HOU ; Jingdong ZHANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(5):569-573
OBJECTIVE:
To compare the effectiveness of early versus delayed closed reduction and percutaneous Kirschner wire fixation in the treatment of pediatric supracondylar humerus fractures.
METHODS:
A retrospective analysis was conducted on 468 children with supracondylar humerus fractures, who were admitted between January 2020 and December 2023 and met the inclusion criteria. Among them, 187 children were treated during 12 hours after injury (early operation group) and 281 were treated after 12 hours (delayed operation group). There was no significant difference between the two groups ( P>0.05) in the gender, age, injury mechanism, fracture side and type, while there was significant difference in interval from injury to operation ( P<0.05). The operative outcomes, including the operation time, intraoperative blood loss, the length of hospital stay, fracture healing time, elbow function assessed by Flynn criteria at 3 months after operation, and complications, were compared.
RESULTS:
Compared to the delayed operation group, the early operation group demonstrated significantly shorter operation time and less intraoperative blood loss ( P<0.05). There was no significant difference in the length of hospital stay between the two groups ( P>0.05). All children were followed up 3-12 months. The follow-up time was (6.7±2.9) months in the early operation group and (6.9±2.8) months in the delayed operation group, showing no significant difference between the two groups ( P>0.05). There was no significant difference in the fracture healing time between the two groups ( P>0.05). At 3 months after operation, the early operation group exhibited superior Flynn elbow functional outcomes to the delayed operation group ( P<0.05). In the early operation group, there was 1 case of fracture non-union and 3 cases of cubital varus deformity after operation. In the delayed operation group, there was 1 case of nerve injury, 7 cases of fracture non-union, and 12 cases of cubital varus deformity after operation. There was significant difference in the incidence of complications between the two groups ( P<0.05). One case of the early operation group and 10 cases of the delayed operation group underwent secondary operation, showing no significant difference in the incidence of secondary operation between the two groups ( P>0.05).
CONCLUSION
For pediatric supracondylar humerus fractures, early closed reduction and percutaneous Kirschner wire fixation can reduce operation time, minimize intraoperative blood loss and postoperative complications, and improve the functional recovery compared to delayed operation.
Humans
;
Humeral Fractures/surgery*
;
Bone Wires
;
Retrospective Studies
;
Male
;
Female
;
Child
;
Fracture Fixation, Internal/instrumentation*
;
Child, Preschool
;
Treatment Outcome
;
Operative Time
;
Fracture Healing
;
Length of Stay
;
Closed Fracture Reduction/methods*
;
Blood Loss, Surgical
;
Time Factors
;
Time-to-Treatment
;
Postoperative Complications/epidemiology*
9.Biomechanical advantages of personalized Y-shaped plates in treatment of distal humeral intra-articular fractures.
Hao YU ; Jiachen PENG ; Jibin YANG ; Lidan YANG ; Zhi XU ; Chen YANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(5):574-583
OBJECTIVE:
To compare the biomechanical properties of personalized Y-shaped plates with horizontal plates, vertical plates, and traditional Y-shaped plates in the treatment of distal humeral intra-articular fractures through finite element analysis, and to evaluate their potential for clinical application.
METHODS:
The study selected a 38-year-old male volunteer and obtained a three-dimensional model of the humerus by scanning his upper limbs using a 64-slice spiral CT. Four types of fracture-internal fixation models were constructed using Mimics 19.0, Geomagic Wrap 2017, Creo 6.0, and other software: horizontal plates, vertical plates, traditional Y-shaped plate, and personalized Y-shaped plate. The models were then meshed using Hypermesh 14.0 software, and material properties and boundary conditions were defined in Abaqus 6.14 software. AnyBody 7.3 software was used to simulate elbow flexion and extension movements, calculate muscle strength, joint forces, and load torques, and compare the peak stress and maximum displacement of the four fixation methods at different motion angles (10°, 30°, 50°, 70°, 90°, 110°, 130°, 150°) during elbow flexion and extension.
RESULTS:
Under dynamic loading during elbow flexion and extension, the personalized Y-shaped plate exhibits significant biomechanical advantages. During elbow flexion, the peak internal fixation stress of the personalized Y-shaped plate was (28.8±0.9) MPa, which was significantly lower than that of the horizontal plates, vertical plates, and traditional Y-shaped plate ( P<0.05). During elbow extension, the peak internal fixation stress of the personalized Y-shaped plate was (18.1±1.6) MPa, which was lower than those of the other three models, with significant differences when compared with horizontal plates and vertical plates ( P<0.05). Regarding the peak humeral stress, the personalized Y-shaped plate model showed mean values of (10.9±0.8) and (13.1±1.4) MPa during elbow flexion and extension, respectively, which were significantly lower than those of the other three models ( P<0.05). Displacement analysis showed that the maximum displacement of the humerus with the personalized Y-shaped plate during elbow flexion was (2.03±0.08) mm, slightly higher than that of the horizontal plates, but significantly lower than that of the vertical plates, showing significant differences ( P<0.05). During elbow extension, the maximum displacement of the humerus with the personalized Y-shaped plate was (1.93±0.13) mm, which was lower than that of the other three models, with significant differences when compared with vertical plates and traditional Y-shaped plates ( P<0.05). Stress contour analysis showed that the stress of the personalized Y-shaped plate was primarily concentrated at the bifurcation of the Y-shaped structure. Displacement contour analysis showed that the personalized Y-shaped plate effectively controlled the displacement of the distal humerus during both flexion and extension, demonstrating excellent stability.
CONCLUSION
The personalized Y-shaped plate demonstrates excellent biomechanical performance in the treatment of distal humeral intra-articular fractures, with lower stress and displacement, providing more stable fixation effects.
Humans
;
Male
;
Adult
;
Healthy Volunteers
;
Finite Element Analysis
;
Tomography, Spiral Computed
;
Models, Anatomic
;
Biomechanical Phenomena
;
Humeral Fractures, Distal/surgery*
;
Fracture Fixation, Internal/instrumentation*
;
Bone Plates
;
Computer Simulation
;
Precision Medicine/methods*
;
Elbow Joint/surgery*
;
Elbow/surgery*
;
Humerus/surgery*
;
Torque
;
Stress, Mechanical
;
Intra-Articular Fractures/surgery*
;
Prosthesis Design/methods*
;
Imaging, Three-Dimensional
;
Range of Motion, Articular
10.Analysis of effectiveness of Holosight robot navigation-assisted percutaneous cannulated screw fixation in treatment of femoral neck fractures.
Weizhen XU ; Zhenqi DING ; Hui LIU ; Jinhui ZHANG ; Yuanfei XIONG ; Jin WU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(6):673-679
OBJECTIVE:
To investigate the effectiveness of Holosight robotic navigation-assisted percutaneous cannulated screw fixation for femoral neck fractures.
METHODS:
A retrospective analysis was conducted on 65 patients with femoral neck fractures treated with cannulated screw fixation between January 2022 and February 2024. Among them, 31 patients underwent robotic navigation-assisted screw placement (navigation group), while 34 underwent conventional freehand percutaneous screw fixation (freehand group). Baseline characteristics, including age, gender, fracture side, injury mechanism, Garden classification, Pauwels classification, and time from injury to operation, showed no significant differences between the two groups ( P>0.05). The operation time, intraoperative blood loss, fluoroscopy frequency, fracture healing time, and complications were recorded and compared, and hip function was evaluated by Harris score at last follow-up. Postoperative anteroposterior and lateral hip X-ray films were taken to assess screw distribution accuracy, including deviation from the femoral neck axis, inter-screw parallelism, and distance from screws to the femoral neck cortex.
RESULTS:
No significant difference was observed in operation time between the two groups ( P>0.05). However, the navigation group demonstrated superior outcomes in intraoperative blood loss, fluoroscopy frequency, deviation from the femoral neck axis, inter-screw parallelism, and distance from screws to the femoral neck cortex ( P<0.05). No incision infections or deep vein thrombosis occurred. All patients were followed up 12-18 months (mean, 16 months). In the freehand group, 1 case suffered from cannulated screw dislodgement and nonunion secondary to osteonecrosis of femoral head at 1 year after operation, 1 case suffered from screw penetration secondary to osteonecrosis of femoral head at 5 months after operation; and 1 case suffered from nonunion secondary to osteonecrosis of femoral head at 6 months after operation in the navigation group. All the 3 patients underwent internal fixators removal and total hip arthroplasty. There was no significant difference in the incidence of complications between the two groups ( P>0.05). The fracture healing time and hip Harris score at last follow-up in the navigation group were significantly better than those in the freehand group ( P<0.05).
CONCLUSION
Compared to freehand percutaneous screw fixation, Holosight robotic navigation-assisted cannulated screw fixation for femoral neck fractures achieves higher precision, reduced intraoperative radiation exposure, smaller incisions, and superior postoperative hip function recovery.
Humans
;
Femoral Neck Fractures/diagnostic imaging*
;
Bone Screws
;
Fracture Fixation, Internal/instrumentation*
;
Male
;
Female
;
Retrospective Studies
;
Robotic Surgical Procedures/methods*
;
Middle Aged
;
Aged
;
Adult
;
Treatment Outcome
;
Operative Time
;
Fracture Healing
;
Surgery, Computer-Assisted/methods*
;
Fluoroscopy

Result Analysis
Print
Save
E-mail