1.Treatment of irreducible intertrochanteric femoral fracture in elderly with proximal femoral nail antirotation combined with minimally invasive clamp reduction technique by Kocher pincers.
Hongwei TANG ; Yong YIN ; Yinhua MA
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(5):536-541
OBJECTIVE:
To explore the effectiveness of proximal femoral nail antirotation (PFNA) combined with minimally invasive clamp reduction technique by Kocher pincers in the treatment of irreducible intertrochanteric femoral fracture in the elderly.
METHODS:
The clinical data of 35 elderly patients with irreducible intertrochanteric femoral fractures who were treated with PFNA combined with minimally invasive clamp reduction technique by Kocher pincers between January 2016 and December 2022 were retrospectively analysed. There were 16 males and 19 females, aged from 63 to 95 years (mean, 75.2 years). The causes of injury included traffic accident in 3 cases and falling in 32 cases. The time from injury to operation was 2-11 days (mean, 3.6 days). According to AO/Orthopaedic Trauma Association (AO/OTA) classification system for intertrochanteric fractures, there were 14 cases of type A1, 18 cases of type A2, and 3 cases of type A3. According to the displacement of fracture by intraoperative fluoroscopy, there were 5 cases with only coronal displacement, 17 cases with only sagittal displacement, and 13 cases with both coronal and sagittal displacement. The operation time, intraoperative blood loss, rate of hemoglobin decline at 1 day after operation, length of hospital stay, and fracture healing time were recorded. The reduction quality of fracture during operation was evaluated according to reduction quality criteria proposed by Chang et al. The Harris scoring system was used to evaluate the hip joint function at last follow-up.
RESULTS:
The operation time was 45-105 minutes (mean, 54.4 minutes); the intraoperative blood loss was 80-300 mL (mean, 116.3 mL). The reduction quality of fracture during operation was good in 22 cases (62.9%) and acceptable in 13 cases (37.1%). The rate of hemoglobin decline at 1 day after operation ranged from 6.2% to 18.6% (mean, 10.2%); the length of hospital stay was 5-18 days (mean, 7.2 days). One case died of respiratory failure due to pulmonary infection, 2 cases were lost to follow-up, and the remaining 32 cases were followed up 6-24 months (mean, 10.6 months). All 32 patients achieved bony union and the healing time was 3-9 months (mean, 3.6 months). There was no complication such as incision infection, internal fixation failure, or coxa varus during follow-up. At last follow-up, the Harris score of hip joint was 67-96 (mean, 88.9); among them, 19 cases were excellent, 10 cases were good, 2 cases were fair, and 1 case was poor, with an excellent and good rate of 90.6%.
CONCLUSION
For the elderly patients with irreducible intertrochanteric femoral fracture, the application of PFNA combined with minimally invasive clamp reduction technique by Kocher pincers can achieve high-quality fracture reduction, which has the advantages of simple reduction operation, less trauma, and can avoid the radiation exposure of operators during maintenance reduction.
Humans
;
Male
;
Female
;
Aged
;
Minimally Invasive Surgical Procedures/methods*
;
Hip Fractures/diagnostic imaging*
;
Bone Nails
;
Aged, 80 and over
;
Retrospective Studies
;
Fracture Fixation, Intramedullary/instrumentation*
;
Middle Aged
;
Treatment Outcome
;
Fracture Fixation, Internal/instrumentation*
;
Fracture Healing
;
Femoral Fractures/surgery*
2.Antegrade elastic intramedullary nailing fixation via a novel approach through proximal radius for distal radius metaphyseal-diaphyseal junction fractures in children.
Bin JIN ; Xinglei SHI ; Hailong MA ; Junchen ZHU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(9):1155-1159
OBJECTIVE:
To investigate the surgical technique and preliminary effectiveness of closed reduction and internal fixation (CRIF) using antegrade elastic intramedullary nailing (ESIN) via a novel approach through the proximal radius for treating distal radius metaphyseal-diaphyseal junction (DRMDJ) fractures in children.
METHODS:
A retrospective analysis was conducted on 34 children with DRMDJ fractures who met the selection criteria and were treated between January 2020 and June 2023. There were 21 boys and 13 girls, aged 6-14 years (mean, 8.2 years). Injury causes included falls in 11 cases and sports-related trauma in 23 cases. Twenty-six cases were associated with ipsilateral distal ulnar fractures. All patients had failed initial closed reduction in the outpatient clinic. The time from injury to operation ranged from 1 to 15 days (mean, 4 days). All patients underwent CRIF using antegrade ESIN inserted via a novel approach at the proximal one-third of the radius. The operation time, intraoperative fluoroscopy frequency, fracture healing time, and complications were recorded. Fracture reduction was assessed immediately after operation on anteroposterior and lateral X-ray films for residual translation and angulation. Wrist function was evaluated using the modified Mayo wrist score.
RESULTS:
Surgery was successfully completed in all 34 children. CRIF with ESIN failed in 2 cases with associated ipsilateral distal ulnar fractures, requiring conversion to open reduction of the ulna. Operation time ranged from 15 to 56 minutes (mean, 21 minutes). Intraoperative fluoroscopy frequency ranged from 5 to 21 times (mean, 7 times). Immediate postoperative X-ray films showed residual translation of 0-15% on anteroposterior view and 0-10% on lateral view, and residual angulation of 0°-5° on both anteroposterior and lateral views. All children were followed up 6-18 months (mean, 12 months). There was no complication such as neurovascular injury, incision infection, or limitation of forearm rotation. Follow-up X-ray films showed no fracture displacement, implant loosening, delayed union, or nonunion. Fracture healing time ranged from 4 to 8 weeks (mean, 6 weeks). Implants were removed at 4-6 months postoperatively (mean, 5 months). At last follow-up, all fractures had achieved anatomic or near-anatomic healing. The modified Mayo wrist score ranged from 80 to 100 (mean, 94), with 27 excellent and 7 good results, yielding an excellent and good rate of 100%.
CONCLUSION
CRIF using antegrade ESIN via a novel approach through proximal radius is a safe and effective treatment for pediatric DRMDJ fractures, associated with few postoperative complications and excellent restoration of wrist function.
Humans
;
Child
;
Female
;
Male
;
Fracture Fixation, Intramedullary/instrumentation*
;
Adolescent
;
Radius Fractures/diagnostic imaging*
;
Retrospective Studies
;
Bone Nails
;
Treatment Outcome
;
Fracture Healing
;
Diaphyses/surgery*
;
Radius/surgery*
;
Operative Time
;
Closed Fracture Reduction/methods*
;
Ulna Fractures/surgery*
3.Effectiveness of additional anti-rotation steel plate assisted intramedullary nail technology in aseptic femoral non-union.
Wei WANG ; Miaomiao YANG ; Xiaowen DENG ; Fan LI ; Wenbo LI ; Weiwei SHEN ; Peisheng SHI ; Jie SHI ; Chuangbing LI ; Yun XUE ; Qiuming GAO
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(9):1170-1174
OBJECTIVE:
To explore the effectiveness of additional anti-rotation steel plate assisted intramedullary nail technology in treatment of aseptic femoral non-union patients.
METHODS:
A retrospective analysis was conducted on 21 patients with aseptic femoral non-union who admitted between September 2020 and October 2024 and treated with additional anti-rotation steel plate assisted intramedullary nail technology. There were 17 males and 4 females, aged 25-67 years (mean, 44 years). There were 19 cases of femoral anterograde intramedullary nail fixation, 1 case of femoral retrograde intramedullary nail fixation, and 1 case of steel plate fixation with fatigue fracture. There were 9 cases of hypertrophic non-union and 12 cases of atrophic non-union. All patients had varying degrees of fracture end atrophy/sclerosis. Among them, 20 patients who were fixed with intramedullary nails underwent removal of soft tissue and hardened bone at the fracture end, and cortical treatment resulted in the appearance of "chili sign" at the fracture end. Iliac bone grafting and anti-rotation steel plate fixation were performed. One patient with steel plate fixation was removed the steel palte and fixed with a retrograde intramedullary nail, while the hardened bone at the fracture end was removed, iliac bone grafting and anti-rotation steel plate fixation were performed. Postoperative follow-up observation included the incision healing, maximum knee flexion range of motion, bone healing, length of lower limbs, and subjective satisfaction. The lower extremity functional scale (LEFS) score was used to evaluate the lower limb function.
RESULTS:
All incisions healed by first intention. All patients were followed up 7-26 months (mean, 15.5 months). At last follow-up, the femoral fracture healed with the obvious callus formation at the fracture end; the maximum knee flexion range of motion was 95°-127° (mean, 112.67°). The LEFS score increased from 29.9±6.7 before operation to 75.9±3.0 at last follow-up, and the difference was significant (t=-29.622, P<0.001). Except for 1 patient who underwent intramedullary nail dynamic treatment before operation and had a lower limb shortening of about 0.9 cm, the other patients had bilateral lower limbs of equal length. All patients had no postoperative infections, mal-union of fractures, deep vein thrombosis, joint stiffness, or other complications.
CONCLUSION
The use of additional anti-rotation steel plate assisted intramedullary nail technology in the treatment of aseptic femoral non-union not only overcomes the drawbacks of insufficient stability at the fracture end of intramedullary nails, but also overcomes the shortcomings of biased fixation with steel plates. It has the advantages of minimal trauma, effective maintenance of fracture stability, and ideal postoperative functional recovery, making it an effective treatment for aseptic femoral non-union.
Humans
;
Male
;
Fracture Fixation, Intramedullary/instrumentation*
;
Female
;
Bone Plates
;
Middle Aged
;
Adult
;
Femoral Fractures/surgery*
;
Retrospective Studies
;
Bone Nails
;
Aged
;
Fractures, Ununited/surgery*
;
Treatment Outcome
;
Bone Transplantation/methods*
;
Steel
;
Fracture Healing
4.Comparative study on lengthened proximal femoral nail antirotation and InterTan in the treatment of subtrochanteric femur fractures in the elderly.
Zhen-Shan WANG ; Ming-Cong DING ; Jin JIANG ; Jing-Sheng LIU ; Tong-Qun YANG
China Journal of Orthopaedics and Traumatology 2025;38(7):662-667
OBJECTIVE:
To investigate the clinical efficacy of lengthened proximal femoral nail antirotation (PFNA) and InterTan in the treatment of subtrochanteric femur fractures in the elderly.
METHODS:
A retrospective analysis was performed on the data of 65 elderly patients diagnosed with subtrochanteric femoral fractures who met the inclusion criteria between October 2016 and January 2022. The enrolled patients were categorized into two groups according to the type of internal fixation used: the lengthened proximal femoral nail antirotation(PFNA) group and the InterTan group. There were 32 patients in the PFNA group, comprising 20 males and 12 females, with ages ranging from 60 to 85 years old with an average of (69.3±6.7 ) years old. Among these patients, 15 patients resulted from traffic accidents and 17 patients were caused by falls. According to the Seinsheimer classification system, there were 11 patients as type Ⅱ, 14 patients as type Ⅲ, 6 patients as type Ⅳ, and 1 patient as type Ⅴ. The InterTan group comprised 33 patients, including 20 males and 13 females, aged from 60 to 85 years old with an average of (69.8±7.8 ) years old. Of these, 15 patients resulted from traffic accidents, while 18 patients were caused by falls. According to the Seinsheimer classification system, 10 patients as type Ⅱ, 15 patients as type Ⅲ, 7 patients as type Ⅳ, and 1 patient as type Ⅴ. The intraoperative blood loss, operative duration, and fracture healing time were recorded and compared between two groups. The quality of fracture reduction was assessed using Chang's criteria. Additionally, the Harris hip score was utilized to evaluate hip function in both groups at 3 months postoperatively and at the final follow-up.
RESULTS:
All patients were followed up for a period ranging from 10 to 20 months with an average of (14.6±4.5) months. No statistically significant differences were observed between two groups in terms of operation time, intraoperative blood loss, quality of fracture reduction, or reduction methods (P>0.05). Three months after the surgery, the Harris hip score in the InterTan group was 80.0(78.0, 83.5) points, which was significantly higher than that in the PFNA group, which recorded a score of 77.5(75.0, 81.8) points. This difference was statistically significant (P<0.05). At the final follow-up, the Harris hip score in the InterTan group was 80.0(76.5, 87.0), while that in the PFNA group was 78.0(74.3, 82.8). No statistically significant difference was observed between two groups (P>0.05).
CONCLUSION
The use of lengthened PFNA and InterTan in the treatment of elderly subtrochanteric femur fractures can both achieve good treatment results, with the advantages of simple operation, firm fixation, and low failure rate of internal fixation. The lengthened InterTan can achieve better hip function than PFNA.
Humans
;
Male
;
Female
;
Aged
;
Aged, 80 and over
;
Bone Nails
;
Retrospective Studies
;
Hip Fractures/surgery*
;
Middle Aged
;
Fracture Fixation, Intramedullary/instrumentation*
;
Fracture Fixation, Internal/methods*
;
Femoral Fractures/surgery*
5.A distal-lock electromagnetic targeting device for intramedullary nailing: Suggestions and clinical experience.
Guido ANTONINI ; Wilfried STUFLESSER ; Cornelio CRIPPA ; Georgios TOULOUPAKIS
Chinese Journal of Traumatology 2016;19(6):358-361
PURPOSETo describe our clinical experience with a system named SureShot? Distal Targeting (Smith & Nephew, Memphis, USA) based on magnetic field presence and discuss our suggestions on this technique.
METHODSWe analysed prospectively 47 patients affected by humeral, tibial or femoral fractures, treated in our institution during a 3-year period of time (August 2010 to September 2013). We considered the following parameters: the time to set up, the time to position a single screw, the effectiveness of the system (drilling ad screwing), the irradiation exposure time during distal locking procedure and surgical complications.
RESULTSA total number of 96 screws were inserted. The mean preparation time of the device was 5.1 min ± 2 min (range 3-10 min). The mean time for single screw targeting was 5.8 min ± 2.3 min (range 4-18 min). No major complications occurred. Only a few locking procedures were needed to be practiced in order to obtain the required expertise with this targeting device.
CONCLUSIONAccording to our results, this device is reliable and valid whenever the correct technique is followed. It is also user friendly, exposes to lower radiation and needs less surgical time compared to relative data from the literature. However, the surgeon should always be aware of how to use the free hand technique in case of malfunctioning of the system.
Bone Screws ; Fracture Fixation, Intramedullary ; adverse effects ; instrumentation ; methods ; Humans ; Magnetic Fields ; Prospective Studies
6.Comparison of anatomical locking plate and Gamma nail for the treatment of intertrochanteric fracture with external wall fractures.
Yun-gen HU ; Lei HAN ; Wei-li FANG ; Bo JIN
China Journal of Orthopaedics and Traumatology 2016;29(6):496-501
OBJECTIVETo compare clinical efficacy of anatomic locking plate and Gamma nail in treating unstable femoral intertrochanteric fractures with external wall fractures.
METHODSFrom June 2010 to June 2014,clinical data of 44 patients with intertroehanteric fractures associated with lateral wall fractures (type 31A2.2-3.3) followed more than 12 months,which treated with Gamma nail or anatomic locking plate,were retrospective analyzed. Sixteen patients were treated with anatomic locking plate, including 6 males and 10 females aged from 32 to 83 years old with an average of 56.5 years old. Twenty-eight patients were treated with Gamma nail including 17 males and 11 females aged from 26 to 87 years old with an average of 60.4 years old. Operative time, intraoperative fluoroscopy times, blood loss (intraoperative and hidden blood loss), hospital stays were observed and compared. PPMS and HHS scoring were used to evaluate postoperative clinical effect.
RESULTSAll patients were followed up from 12 to 24 months with an average of 16.2 months. Operative time in Gamma nail was shorter than anatomic locking plate; while blood loss( intraoperative and hidden blood loss) and intraoperative fluoroscopy times in anatomic locking plate were less than that of in Gamma nail. There was no significant meaning in hospital stays between two groups. Postoperative full weight-bearing time in anatomic locking plate was prolonged than Gamma nail. At the final following-up, PPMS in Gamma nail was 7.50 ± 1.78 and 6.82 ± 1.38 in anatomic locking plate, and there was no obvious meaning between two groups (t = 2.341, P = 0.132); there was no significant differences in HHS score between Gamma nail (83.25 ± 11.18) and anatomic locking plate (86.14 ± 12.36) (t = 1.923, P = 0.243). The incidence of complications in Gamma nail was less than anatomic lock-ing plate (P = 0.005).
CONCLUSIONAnatomic locking plate for intertrochanteric fractures with external wall fractures could avoid re-injury of external wall, especially for severe comminuted fractures, difficult for intramedullary nailing, and there was no significant meaning in hip joint function compared with Gamma nail, while postoperative incidence of complications was higher than Gamma nail, so early weight-bearing was not stress.
Adult ; Aged ; Bone Nails ; Bone Plates ; Female ; Fracture Fixation, Intramedullary ; instrumentation ; methods ; Hip Fractures ; surgery ; Hip Joint ; surgery ; Humans ; Male ; Middle Aged ; Retrospective Studies ; Young Adult
8.Application of double joystick technique in reduction-internal fixation for femoral shaft fracture in adults.
Wang ZHI-YONG ; Ke CHEN ; Ke-wei TIAN ; Ye YE
China Journal of Orthopaedics and Traumatology 2015;28(7):606-608
OBJECTIVETo study the applied value of double joystick technique in reduction-internal fixation for femoral shaft fracture in adults.
METHODSThirty-four patients (24 males and 10 females) with femoral shaft fractures were treated with reduction assisted by double joystick technique and internal fixation with interlocking intramedullary nail from September 2010 to June 2013. The average age of the patients was 41 years old, ranged from 17 to 65 years old. The duration of the disease course ranged from 3 to 7 days, with a mean of 5 days. The fractures belonged to AO types 32A (5 cases), 32B (20 cases) and 32C (9 cases) and located in left femur for 18 patients and right femur for 16 patients. The patients were followed up, and fracture healing and complications were observed. The curative effect were evaluated according to Thorsen femur fracture evaluation standard.
RESULTSThe operative time ranged from 40 to 110 min (mean 75 min) and intraoperative blood loss ranged from 200 to 300 ml (mean 250 ml). All the patients obtained a good fracture reduction and were followed up for 12 to 24 months (mean 18 months) after the surgery. All the fractures united between 4 and 8 months with a mean of 5 months. No complications such as breakage of nail, infection, osteofascial compartment syndrome, refracture and fracture malunion were found. According to Thorsen femur fracture evaluation standard, 30 patients obtained an excellent result, 3 good and 1 fair.
CONCLUSIONIn surgery of reduction-internal fixation for femoral shaft fracture in adults, the use of double joystick technique obtains good reduction result, short operative time, less injury, high healing rate of bone fractures, less complications and good limbs function, so it is worthy of popularizing in clinic.
Adolescent ; Adult ; Aged ; Bone Nails ; Female ; Femoral Fractures ; physiopathology ; surgery ; Fracture Fixation, Intramedullary ; instrumentation ; methods ; Fracture Healing ; Humans ; Male ; Middle Aged ; Young Adult
9.Curative effect analysis on proximal frmoral nail antirotation for the treatment of femoral intertrochanteric fracture and integrity of lateral trochanteric wall.
Jie WEI ; De-an QIN ; Xiu-sheng GUO
China Journal of Orthopaedics and Traumatology 2015;28(6):572-575
OBJECTIVETo explore clinical efficacy and key matters for the treatment of femoral intertrochanteric fracture and integrity of lateral trochanteric wall by proximal frmoral nail antirotation (PFNA).
METHODSFrom June 2010 to December 2012,210 femoral intertrochanteric fracture patients treated with PFNA were retrospectively analyzed, including 76 males and 134 females aged from 46 to 96 years old with an average of 71 years old. All fracture were caused by injury and classified to type I (5 cases) type II (16 cases), type III (73 cases) and type IV (116 cases) according to Evans classification. The time of getting out of bed, postoperative complications and displacement of screw blade and fracture healing were observed, Baumgaertner criteria were used to evaluate quality of fracture reduction, Harris criteria were used to evaulate hip joint function.
RESULTSAll incisions were healed at stage I, no complications occurred except incomplete of lateral trochanteric wall patients without reconstruction, other patients could get out of bed with crutches at one week and all patients discharged from hospital at 10 days after operation. One hundred and seventy-eight patients were followed up from 3 to 17 months with an average of 10 months. One case occurred unhealed fracture displacement caused by screw blade cutting, 2 cases occurred screw blade transfomed to proximal and out femoral head, other patients obtained fracture healing at 12 to 16 weeks after operation. According to Baumgaertner criteria, 130 cases obtained good results, 45 cases acceptable, and 3 poor; while 107 cases obtained excellent results, 65 good, 3 good and 3 poor according to Harris score.
CONCLUSIONPFNA with mechanical advantage of intramedullary fixation has advantsges of stable fixation, shorter operation time, minimally invasive. Satisfied clinical effects could obtained by grasping fixation principle, dealing with negative factors in operation. Intraoperative reconstruction for integrity of lateral trochanteric wall could assure stable fixation and earlier get out of bed.
Aged ; Aged, 80 and over ; Bone Nails ; Female ; Femoral Fractures ; surgery ; Fracture Fixation, Intramedullary ; instrumentation ; methods ; Hip Fractures ; surgery ; Humans ; Male ; Middle Aged ; Retrospective Studies
10.Treatment of clavicular fractures using intramedullary nailing or K-wire versus plating fixation: a meta-analysis.
Ke-xue ZHANG ; Jing-xin ZHAO ; Zhe ZHAO ; Li-cheng NG ; Xiu-yun SU ; An-hua LONG ; Zhi MAO ; Jin-hui ZHANG ; Li-hai ZHANG ; Pei-fu TANG
China Journal of Orthopaedics and Traumatology 2015;28(5):454-461
OBJECTIVETFo compare the efficacy and complications rate of intramedullary (IM) nailing or K-wire versus plating fixation for clavicular fractures.
METHODSPubmed, Embase, Cochrane Library databases, CNKI, VIP and Wangfang databases were searched to find all randomized or quasi-randomized controlled trials of clavicle fractures using plating versus IM nailing or K-wire. The methodologic quality of the studies was assessed. After independent study selection by 2 authors ,data were collected and extracted independently. Outcomes of postoperative shoulder functional measurement, the efficacy and information of the operation and complications rate were meta-analyzed using RevMan 5 software.
RESULTSNine hundreds and seventy-six patients in 10 randomized controlled trials (RCTs) and 3 quasi-RCTs were involved in the meta-analysis,of which 5 studies compared the K-wire and the plating fixations and 8 studies compared the IM nailing and the plating fixations. The overall odds ratio(OR) (with 95% CI) of the operation efficacy for K-wire versus the plating was 3.79 (1.93, 7.46). The overall weighted mean difference (with 95% CI) of Constant Shoulder score for plating versus IM fixation was -1.39 (-3.43, 0.65) in 6 studies. The overall OR of the plating versus IM nailing was 9.34(2.70, 32.32) for the overall major complications in 5 studies and 5.04 (1.52,16.77) for the revision rate in 5 studies.
CONCLUSIONThe current limited evidences suggested that the IM fixation could reduce the incidences of the overall major complications and the revision surgery, while the post-operative efficacy of the plating was superior to the K-wire. More high quality RCTs are still needed in the future.
Bone Nails ; Bone Wires ; Clavicle ; injuries ; surgery ; Fracture Fixation, Intramedullary ; instrumentation ; methods ; Fractures, Bone ; surgery ; Humans ; Randomized Controlled Trials as Topic

Result Analysis
Print
Save
E-mail