1.TiRobot-assisted minimally invasive treatment of geriatric fragility fractures of the pelvis.
Canhui LI ; Yonghong DAI ; Weiqiong CAI ; Xiaopeng SITU ; Yanhui ZENG ; Xuelian DU ; Shi HONG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(11):1421-1427
OBJECTIVE:
To investigate the effectiveness of TiRobot-assisted minimally invasive treatment for fragility fractures of the pelvis (FFP) in elderly patients.
METHODS:
A retrospective analysis was conducted on the clinical data of 176 patients with FFP who were admitted between July 2018 and July 2024 and met the selection criteria. Among them, 95 patients underwent TiRobot-assisted closed reduction and minimally invasive cannulated screw fixation (robot group), while 81 patients underwent traditional open reduction and plate screw fixation (control group). There was no significant difference in baseline data such as gender, age, fracture classification, disease duration, and preoperative visual analogue scale (VAS) pain scores between the two groups ( P>0.05). The following parameters were recorded and compared between the two groups, including operation time, intraoperative blood loss, intraoperative transfusion rate, volume of intraoperative blood transfusion, maximum incision length, hospital stay, maximum residual displacement, reduction quality, fracture healing time, incidence of complications, VAS scores, Majeed pelvic function scores, and functional grading.
RESULTS:
All surgeries in both groups successfully completed. The robot group exhibited significantly shorter operation time, reduced intraoperative blood loss, lower intraoperative transfusion rate, smaller volume of intraoperative blood transfusion, shorter maximum incision length, and shorter hospital stay compared to the control group ( P<0.05). In the robot group, a total of 14 INFIX internal fixation frames and 280 cannulated screws were implanted, among which 250 screws were rated as excellent, 17 as good, and 13 as poor, resulting in a screw placement excellent and good rate of 95.36%. Radiological review revealed that the excellent and good rate of reduction quality was in 91.58% (87/95) in the robot group and 81.48% (66/81) in the control group, with no significant difference in postoperative maximum residual fracture displacement or reduction quality between the two groups (P>0.05). All patients in both groups were followed up 12-66 months, with an average of 28.9 months, and there was no significant difference in follow-up time between the two groups ( P>0.05). The fracture healing time in the robot group was significantly shorter than that in the control group ( P<0.05). At last follow-up, both groups showed significant improvement in VAS scores compared to preoperative values ( P<0.05); the change values of VAS scores, Majeed scores, and the excellent and good rate of Majeed pelvic function were significantly higher in the robot group than in the control group ( P<0.05). Regarding postoperative complications, there was no significant difference between the two groups in terms of gait changes, secondary surgeries, heterotopic ossification, incision infections, walking difficulties, internal fixation failure, or mortality rates ( P>0.05); however, the incidence of delayed wound healing was significantly lower in the robot group than in the control group ( P<0.05).
CONCLUSION
TiRobot-assisted minimally invasive treatment of elderly FFP is superior to traditional open reduction and internal fixation in terms of surgical trauma control, postoperative rehabilitation speed, and functional recovery.
Humans
;
Male
;
Retrospective Studies
;
Female
;
Minimally Invasive Surgical Procedures/instrumentation*
;
Fracture Fixation, Internal/instrumentation*
;
Pelvic Bones/surgery*
;
Aged
;
Bone Screws
;
Bone Plates
;
Robotic Surgical Procedures/methods*
;
Aged, 80 and over
;
Treatment Outcome
;
Osteoporotic Fractures/surgery*
;
Operative Time
;
Blood Loss, Surgical
;
Fracture Healing
;
Fractures, Bone/surgery*
2.Anteromedial cortical support reduction in treatment of trochanteric femur fractures: a ten-year reappraisal.
Sunjun HU ; Shouchao DU ; Shimin CHANG ; Wei MAO ; Zhenhai WANG ; Kewei TIAN ; Tao LIU ; Yunfeng RUI
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(12):1501-1509
OBJECTIVE:
This review summarized the first 10-year progresses and controversies in the concept of anteromedial cortical support reduction, to provide references for further study and clinical applications.
METHODS:
Relevant domestic and foreign literature on cortical support reduction was extensively reviewed to summarize the definition of positive, neutral, and negative support, anteromedial cortices at the inferior corner, intraoperative technical tips for fracture reduction, radiographic assessment at different periods, comparison between positive versus neutral and medial versus anterior support, and the clinical efficacy of Chang reduction quality criteria (CRQC) and postoperative stability score.
RESULTS:
Anteromedial cortical support reduction was only focused on the cortex of anteromedial inferior corner, with no concern the status of lateral wall or lesser trochanter. Anteromedial cortex was seldom involved by fracture comminution, it was thicker, denser, and stronger, and was the key for mechanical buttress of the head-neck fragment to share compression load. Positive, neutral, and negative support were also called "extramedullary, anatomic, and intramedullary reduction", respectively. There was hardly seen parallel cortical apposition, but characterized by some kinds of head-neck rotation, for example 10°-15° flexed rotation for positive cortical contact and support. Due to intraoperative compression and postoperative impaction, the status of cortical support may be changed at different time of radiographic examination. The positive medial cortex support was more reliable with less reduction loss than its neutral counterpart, and the anterior cortex contact was more predictive than the medial cortex for final results. As incorporation the bearing of cortex apposition and using a 4-point score, CRQC demonstrated more efficacy and was gradually accepted and applied in the evaluation of trochanteric fracture reduction quality. Postoperative stability score (8 points) provided a assessment tool for early weight-bearing in safety to prevent mechanical failure.
CONCLUSION
Anteromedial cortical support reduction is a key point for stability reconstruction in the treatment of trochanteric femur fractures. Evidence has definitely shown that non-negative (positive and neutral) is superior to negative (loss of cortical support). There is a tendency that positive cortex support is superior to neutral, but high quality study with large sample size is needed for a clear conclusion.
Humans
;
Femur/diagnostic imaging*
;
Fracture Fixation, Internal/methods*
;
Hip Fractures/diagnostic imaging*
;
Treatment Outcome
;
Fracture Fixation, Intramedullary/methods*
3.Effectiveness of posterior single-level osteotomy with 360° release and correction in treatment of osteoporotic vertebral compression fractures with moderate to severe kyphosis.
Peidong QING ; Hongda XU ; Youpeng HU ; Bin XIE ; Tieheng WANG ; Lei ZHANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(12):1574-1579
OBJECTIVE:
To explore the effectiveness of posterior single-level osteotomy with 360° release and correction for the treatment of osteoporotic vertebral compression fractures (OVCF) complicated with moderate to severe kyphosis.
METHODS:
A retrospective analysis was conducted on 11 patients with OVCF complicated with moderate to severe kyphosis between January 2022 and March 2023. There were 4 males and 7 females with an average age of 57 years ranging from 47 to 69 years. The disease duration ranged from 3 to 15 months, with an average of 7 months. Fracture segments included T 11 in 3 cases, T 12 in 5, L 1 in 2, and L 2 in 1. The T value of lumbar spine bone density was -5.0 to -2.0, with an average of -3.5. The preoperative neurological function was grade E according to Frankel grading. The Pfirrmann classification of the intervertebral disc above the injured vertebra was grade Ⅲ in 8 cases and grade Ⅳ in 3 cases. All patients underwent posterior single-level osteotomy with 360° release and correction. The operation time, intraoperative blood loss, hospital stay, and postoperative complications were recorded. Thoracolumbar local kyphosis Cobb angle, the mean height of the functional spinal unit (FSU), the sagittal vertical axis (SVA), and the sagittal index (SI) were measured. The visual analogue scale (VAS) score and Oswestry disability index (ODI) were used to evaluate the improvement of pain and function before operation, at 1 month after operation, and at last follow-up.
RESULTS:
The operation successfully completed in all patients, and there was no obvious complication. The operation time ranged from 100 to 190 minutes, with an average of 153 minutes, and the intraoperative blood loss ranged from 200 to 800 mL, with an average of 468 mL. The length of hospital stay was 8-14 days (mean, 12 days). All patients were followed up 6-24 months, with an average of 12.4 months. At last follow-up, all the 11 patients had bony fusion in the osteotomy area, and there was no displacement or subsidence of the Cage, no complication such as internal fixation failure or pseudarthrosis formation was found. The Cobb angle of local thoracolumbar kyphosis, the mean height of FSU, SVA, and SI significantly improved immediately after operation and at last follow-up when compared with preoperative ones, and the VAS score and ODI also significantly improved at 1 month after operation and at last follow-up ( P<0.05); there was no significant difference in above indexes between the two time points after operation ( P>0.05).
CONCLUSION
Posterior single-level osteotomy with 360° release and correction is an effective surgical method for treating OVCF complicated with moderate to severe kyphosis, with definite early effectiveness.
Humans
;
Kyphosis/etiology*
;
Male
;
Female
;
Osteotomy/methods*
;
Middle Aged
;
Retrospective Studies
;
Aged
;
Spinal Fractures/diagnostic imaging*
;
Fractures, Compression/diagnostic imaging*
;
Osteoporotic Fractures/complications*
;
Treatment Outcome
;
Lumbar Vertebrae/injuries*
;
Thoracic Vertebrae/injuries*
;
Operative Time
;
Fracture Fixation, Internal/methods*
4.Comparison of short-term clinical efficacy between CO external fixation and internal fixation with steel plate in the treatment of unstable distal radius fractures.
Min-Rui FU ; Chang-Long SHI ; Yong-Zhong CHENG ; Ming-Ming MA ; Zheng-Lin NIU ; Hai-Xiang SUN ; Jing-Hua GAO ; Zhong-Kai WU ; Yi-Ming XU
China Journal of Orthopaedics and Traumatology 2025;38(1):10-17
OBJECTIVE:
To evaluate the short-term clinical efficacy of external fixation and internal fixation with steel plate in the treatment of unstable distal radius fractures (AO-23C type), based on the principles of Chinese osteosynthesis (CO).
METHODS:
Forty-eight patients with unstable distal radius fractures between January 2022 and February 2023 were retrospectively analyzed and divided into the CO external fixation group and internal fixation group. CO external fixation group consisted of 25 patients, including 7 males and 18 females, aged from 37 to 56 years old with an average of ( 52.6±11.3) years old. Among them, there were 7 patients of traffic accidents and 18 patients of falls, resulting in a total of 25 patients of closed fractures and no open fractures, the treatment was conducted using closed reduction and CO external fixation. The internal fixation group consisted of 23 patients, comprising 8 males and 15 females, age ranged from 41 to 59 years old, with an average age of(53.3±13.7) years old. Among them, 8 patients resulted from car accidents while the remaining 15 patients were caused by falls. All 23 patients were closed fractures without any open fractures observed. The technique of open reduction and internal fixation with steel plate was employed. The perioperative data, including injury-operation time, operation duration, blood loss, and length of hospital stay, were assessed in both groups. Additionally, the QuickDASH score and visual analogue scale (VAS) were evaluated. Range of motion and grip strength assessment, imaging findings such as palmar inclination angle, ulnar declination angle, radius length, articular surface step, intra-articular space measurements were also examined along with any complications.
RESULTS:
The follow-up duration ranged from 0 to 24 months, with an average duration of (16.0±3.8) months. The CO external fixation exhibited significantly shorter time from injury to operation (2.4±3.3) d vs (7.4±3.7) d, shorter operation duration (56.27±15.23) min vs (74.10±5.26) min, lower blood loss (14.52±6.54) ml vs (32.32±10.03) ml, and reduced hospitalization days (14.04±3.24 )d vs (16.45±3.05) d compared to the internal fixation group (P<0.05). The QuickDASH score at 12 months post-operation was (8.21±1.64) in the CO external fixation group, while no significant difference was observed in the internal fixation group (7.04±3.64), P>0.05. There were no statistically significant differences in VAS between two groups at 6 weeks, as well as 1 and 3 months post-surgery (P>0.05). Additionally, there were no significant disparities observed in terms of range of motion and grip strength between two groups at the 2-year follow-up after the operation (P>0.05). After 12 months of surgery, the CO external fixation group exhibited a significantly smaller palmar inclination angle (17.90±2.18) ° vs (19.87±3.21) °, reduced articular surface step (0.11±0.03) mm vs (0.17±0.02) mm, and shorter radius length (8.16±1.11) mm compared to the internal fixation group (9.59±1.02) mm, P<0.05. The ulnar deviation angle and intra-articular space did not show any significant difference between two groups (P>0.05). The reduced fell within the allowable range between the CO external fixation group (23 out of 25 cases) and the internal fixation group (21 out of 23 cases) was not statistically significant (P=0.29). There was no significant difference in complications between the two groups(P>0.05).
CONCLUSION
Both the CO external fixation and open reduction with plate internal fixation demonstrate clinical efficacy in managing unstable distal radius fractures. The CO external fixation offers advantages in shorter injury-to-operation times, reduced intraoperative blood loss, and decreased surgical durations, while radial shortening is more effectively controlled by internal fixation.
Humans
;
Male
;
Female
;
Middle Aged
;
Radius Fractures/physiopathology*
;
Adult
;
Bone Plates
;
Fracture Fixation, Internal/methods*
;
External Fixators
;
Retrospective Studies
;
Fracture Fixation/methods*
;
Wrist Fractures
5.Clinical efficacy of open reduction and internal fixation with plates versus minimally invasive Kirschner wire fixation for osteoporotic Colles' fractures.
Jun-Wei ZHANG ; Jin-Yong HOU ; Zhao-Hui LI ; Zhen-Yuan MA ; Xiang GAO ; Hong-Zheng BI ; Ling-Ling CHEN ; Hai-Tao WANG ; Wei-Zhi NIE ; Yong-Zhong CHENG ; Xiao-Bing XI
China Journal of Orthopaedics and Traumatology 2025;38(1):18-24
OBJECTIVE:
To compare the short-term clinical efficacy and safety of closed reduction with Kirschner wire fixation versus open reduction with plate fixation for treating osteoporotic Colles' fractures in middle-aged and elderly patients.
METHODS:
Between January 2018 and January 2023, 119 patients with Colles fractures were retrospectively analyzed, including 39 males and 80 females, aged from 48 to 74 years old with an average of(60.58±6.71) years old. The time from injury to operation ranged 1 to 13 days with an average of (5.29±2.52) days. According to the surgical method, they were divided into Kirschner wire fixation group (Kirschner wire group) and plate internal fixation group (plate group). In Kirschner wire group, there were a total of 68 patients, comprising 21 males and 47 females. The average age was (61.15±6.24) years old, ranged from 49 to 74 years old. Among them, 41 cases involved the left side while 27 cases involved the right side. In the plate group, there were a total of 51 patients, including 18 males and 33 females. The average age was (59.78±5.71) years old ranged from 48 to 72 years old. Among them, there were 31 cases on the left side and 20 cases on the right side. The following parameters were recorded before and after the operation:operation time, intraoperative blood loss, hospitalization days, hospitalization expenses, postoperative complications, and radiographic parameters of distal radius (distal radius height, ulnar deviation angle, palmar tilt angle). The clinical efficacy was evaluated at 3 and 12 months after the operation using Gartland-Werley and disabilites of the arm shoulder and hand (DASH) scores.
RESULTS:
The patients in both groups were followed up for a duration from 12 to 19 months with an average of(13.32±2.02) months. The Kirschner wire group exhibited significantly shorter operation time compared to the plate group 27.91(13.00, 42.00) min vs 67.52(29.72, 105.32) min, Z=-8.74, P=0.00. Intraoperative blood loss was also significantly lower in the Kirschner wire group than in the plate group 3.24(1.08, 5.40) ml vs 21.91(17.38, 26.44) ml, Z=-9.31, P=0.00. Furthermore, patients in the Kirschner wire group had a shorter length of hospital stay compared to those in the plate group (8.38±2.63) days vs (11.40±2.78) days, t=-3.12, P=0.00. Additionally, hospitalization cost was significantly lower in the Kirschner wire group than in the plate group 10 111.29(6 738.98, 13 483.60) yuan vs 15 871.11(11 690.40, 20 051.82) yuan, Z=-5.62, P=0.00. The incidence of complications was 2 cases in the Kirschner wire group and 1 case in the plate group, with no statistically significant difference(P>0.05). At 3 months postoprative, the radial height of the Kirschner wire group was found to be significantly smaller than that of the plate group, with measurements of (11.45±1.69) mm and (12.11±1.78) mm respectively (t=-2.06, P=0.04). However, there were no statistically significant differences observed in ulnar deviation angle and palmar tilt angle between the two groups (P>0.05). The DASH score and Gartland-Werley score in the Kirschner group were significantly higher than those in the plate group at 3 months post-operation (19.10±9.89) vs (13.47±3.51), t=4.34, P=0.00;(11.15±3.61) vs (6.41±2.75), t=8.13, P=0.00). However, there was no significant difference between the two groups at 12 months post-operation (P>0.05).
CONCLUSION
Compared to plate internal fixation, closed reduction with Kirschner wire support fixation yields a slightly inferior recovery of radial height;however, there is no significant disparity in the functional score of the affected limb at 12 months post-operation. Nonetheless, this technique offers advantages such as shorter operation time, reduced intraoperative blood loss, decreased hospitalization duration, and lower cost.
Humans
;
Female
;
Male
;
Middle Aged
;
Aged
;
Fracture Fixation, Internal/instrumentation*
;
Bone Wires
;
Bone Plates
;
Retrospective Studies
;
Colles' Fracture/surgery*
;
Minimally Invasive Surgical Procedures/methods*
;
Open Fracture Reduction/methods*
;
Osteoporotic Fractures/surgery*
6.Thoracoscopic minimally invasive surgery for the treatment of flail chest with multiple rib fractures.
Pan ZHOU ; Zhong-Quan WU ; Jie ZHU ; Ling-Ling CHENG ; Sheng SHU
China Journal of Orthopaedics and Traumatology 2025;38(1):47-54
OBJECTIVE:
To investigate the clinical efficacy of thoracoscopic minimally invasive surgery with nickel-titanium shape memory alloy wrap bone plate versus rib periosteal internal fixation in patients with multiple rib fractures (MRF) and flail chest.
METHODS:
A retrospective analysis was performed on 100 patients with MRF and flail chest treated with thoracoscopic minimally invasive surgery and internal fixation with rib fracture preservation between January 2019 and December 2022, including 54 males and 46 females, aged from 20 to 65 years old, with an average age of (38.0±18.0)years old. The duration of the disease ranged from 8 to 21 days. According to the different surgical methods, the patients were divided into control group and study group, with 50 patients in each group. The control group consisted of 23 males and 27 females, with an average age of (38.35±18.05) years old, who underwent rib preservation periosteal internal fixation. In the study group, there were 31 males and 19 females, with an average age of (38.15±17.99) years old, treated with thoracoscopic nickel-titanium shape memory alloy circumferential bone plate. The pulmonary function indices, electrocardiographic monitoring indices, pain severity, levels of inflammatory factors, complications, rehabilitation indices, and therapeutic efficacy were compared between the two groups before and after treatment.
RESULTS:
All patients were followed up for 6 months. After 3 days of treatment, the heart rate of both groups was (102.43±13.74) beats per minute vs (86.26±8.06) beats per minute, respiratory rate (28.45±3.40) breaths per minute vs (22.05±2.85) breaths per minute, blood oxygen saturation (89.68±3.66)% vs (98.46±4.84)%, rest pain (3.5±0.5) points vs (2.6±0.6) points, movement pain (3.6±0.5) points vs (2.5±0.5) points, and these differences were statistically significant(P<0.05). The levels of Interleukin-6 (IL-6) (102.30±17.00) pg·ml-1 vs (85.68±21.20) pg·ml-1 and tumor necrosis factor-alpha (TNF-α)(33.44±4.85) pg·ml-1 vs (18.14±4.28) pg·ml-1 in both groups exhibited an increase post-treatment, while the C-reactive protein (CRP) (75.51±10.54) mg·L-1 vs (60.75±9.84) mg·L-1 demonstrated a decrease compared to pre-treatment levels. Furthermore, the study group displayed significantly lower levels than the control group (P<0.05). After 10 days of treatment, the peak expiratory flow rate (3.31±0.52) L·s-1 vs (5.69±0.74) L·s-1, forced expiratory volume (1.46±0.29) L vs (2.06±0.38) L, and forced vital capacity (2.68±0.95) L vs (4.26±1.05) L of both groups exhibited significant improvements compared to pre-treatment levels. Moreover, the study group demonstrated significantly higher values than the control group (P<0.05). The incidence of postoperative complications in the study group was significantly lower compared to the control group (6 cases vs 14 cases, P<0.05). Additionally, the duration of bone callus formation(9.50±1.40) days and fracture healing (72.20±8.32) days in the study group was significantly shorter compared to the control group(11.35±2.15) days, (93.70±9.90) days (P<0.001).
CONCLUSION
Compared with traditional rib-preserving internal fixation, patients with MRF and flail chest treated with minimally invasive internal fixation with thoracoscopic nickel-titanium shape memory alloy surround bone plate have better therapeutic effect, because of less surgical trauma, less pain and inflammatory reaction, fewer postoperative pulmonary complications, faster and better recovery of lung function, and thus promote the recovery of patients.
Humans
;
Male
;
Female
;
Middle Aged
;
Adult
;
Retrospective Studies
;
Rib Fractures/surgery*
;
Aged
;
Minimally Invasive Surgical Procedures/methods*
;
Flail Chest/surgery*
;
Thoracoscopy/methods*
;
Fracture Fixation, Internal/methods*
7.Meta-analysis of the efficacy of plate fixation and external fixator fixation in the treatment of AO-C type distal radius fractures.
Guang-Yao LI ; Yong-Zhong CHENG ; Huan LIU ; Jun-Jie JIANG ; Yong-Yao LI ; Yang CHEN ; Yu-Xiang YAO
China Journal of Orthopaedics and Traumatology 2025;38(1):66-80
OBJECTIVE:
Meta-analysis of the clinical efficacy of plate and external fixator fixation in the treatment of AO-C type distal radius fractures.
METHODS:
PubMed, Embase, Cochrane Medical Library, Web of Science, CNKI, Wanfang, VIP and SinoMed databases were searched for all literature on randomized controlled clinical trials of AO-C distal radius fractures. The search time limits were from each database. The database will be established until June 30, 2023. The included studies were extracted according to the Cochrane Handbook (Version 6.3, 2022) for information extraction and literature quality evaluation. RevMan 5.4 was used to evaluate the risk of Publication bias, test heterogeneity and Perform Meta-analysis. The outcome indicators were:imaging anatomy indicators (volar inclination angle, ulnar deviation angle, radial height), wrist joint mobility (flexion, extension, rotation, ulnar deviation), complication rate, and comparison of surgical treatments (operative blood loss, operation time, hospitalization time, fracture healing time) and wrist joint function scores and related scales.
RESULTS:
(1) A total of 28 studies were included, with a total of 2 192 patients, including 1 096 cases in the plate internal fixation group and 1 096 cases in the external fixation group.(2) Meta analysis results showed:the surgical treatment situation of the external fixation group:surgical blood loss MD=-37.93, 95%CI(-48.54, -27.31), P<0.000 01;operation time MD=-31.58, 95%CI(-48.96, -14.20), P<0.000 4;hospitalization time MD=-4.58, 95%CI(-5.44, -3.71), P<0.000 01;the fracture healing time MD=-0.88, 95%CI(-1.35, -0.41), P<0.000 2, which were significantly better than that of the plate internal fixation group(P<0.05).(3) The two groups:palmar inclination angle MD=-0.17, 95%CI(-0.95, 0.61), P=0.68;ulnar declination MD=0.22, 95%CI(-0.73, 1.17), P=0.65, radial height MD=-0.24, 95%CI(-1.15, 0.67), P=0.60;flexion and extension MD=-5.63, 95%CI(-11.85, 0.58), P=0.08;rotation MD=-5.80, 95%CI(-12.77, 1.17), P=0.10, radioulnar deviation MD=-2.86, 95%CI(-10.87, 5.15), P=0.48;complication rate RR=0.96, 95%CI(0.63, 1.46), P=0.83;Gartland-Werley clinical wrist score MD=0.13, 95%CI(-0.80, 1.06), P=0.78;excellent and good rate of Gartland-Werley wrist clinical score RR=0.93, 95%CI(0.87, 1.01), P=0.08;excellent and good rate of Cooney wrist score RR=0.99, 95%CI(0.62, 1.59), P=0.98;wrist DASH score MD=-4.67, 95%CI(-14.96, 5.62), P=0.37;the differences were not significant (P>0.05).
CONCLUSION
Compared with internal fixation with plate, external fixation can significantly reduce the amount of surgical bleeding, shorten the operation time, hospitalization time and fracture healing time, and its imaging anatomical indicators, wrist mobility, and complications can be significantly reduced in treating AO-C distal radius fractures. Rates and wrist function scores were equivalent.
Humans
;
External Fixators
;
Bone Plates
;
Radius Fractures/surgery*
;
Fracture Fixation/methods*
;
Fracture Fixation, Internal
;
Wrist Fractures
8.Guiding significance of intra-articular sagittal reduction in the treatment of tibial plateau fractures.
Jia-Fan ZHANG ; An-Hua LONG ; Da-Cheng HAN ; Zi-Chao JIA ; Ya-Kui ZHANG
China Journal of Orthopaedics and Traumatology 2025;38(1):100-104
Tibial plateau fracture is a fracture involving the proximal articular surface of the tibia, and its injury mechanism is complex, the fracture morphology is different, and it is often accompanied by different degrees of soft tissue injury, which is difficult to diagnose and treat. In recent years, the research hotspot has focused on solving the reduction and fixation of the posterior lateral column of the tibial plateau, because it has been clinically found that the residual sagittal plane after tibial plateau fracture is insufficient reduction or loss of reduction leads to knee joint dysfunction. The posterior inclination angle of the tibial plateau is an important parameter to describe the sagittal alignment of the tibia. In the natural state, the posterior tibial slope(PTS) is altered to involve the soft tissues around the knee joint such as anterior cruciate ligament(ACL) and posterior cruciate ligament(PCL), which affects the stability of the knee joint. In total knee arthroplasty(TKA), choosing the appropriate PTS can effectively increase the prosthesis survival rate, improve the flexion and extension knee efficacy, which is beneficial to knee joint stability. In the field of orthopedic trauma, correction of sagittal deformity is equally important, following the principle of "reverse mechanism of injury". Quantitative evaluation of postoperative sagittal realignment of tibial plateau fractures and investigation of the effect of sagittal realignment on long-term outcomes and complications are still poorly understood and require further clinical and biomechanical studies.
Humans
;
Tibial Fractures/physiopathology*
;
Fracture Fixation, Internal/methods*
;
Tibial Plateau Fractures
9.Clinical application of three-dimensional printing technology combined with customized bone plate in the treatment of acetabulum fracture.
Yan-Chao ZANG ; Quan-Yong ZHAO ; Li YANG ; Jin-Zeng ZUO ; Wei QI ; Wei-Dong LIANG ; Jie XING
China Journal of Orthopaedics and Traumatology 2025;38(2):203-207
OBJECTIVE:
To explore the application value and clinical effect of 3D printing combined with customized bone plate in the treatment of acetabular fracture.
METHODS:
From June 2020 to June 2022, 11 patients with acetabular fractures underwent preoperative planning using 3D printing technology and were treated with customized bone plates including 8 males and 3 females, aged 25 to 66 years old. The fractures were classified according to Letournel-Judet:4 posterior wall fractures, 2 T-type fractures, 2 transverse posterior wall fractures, 2 double column fractures, and 1 anterior column with posterior semi-transverse fractures. The operative time, intraoperative blood loss, intraoperative fluoroscopy times, postoperative drainage volume, postoperative fracture healing time, and hip function score were recorded and analyzed.
RESULTS:
The operation time of 11 patients was 80 to 150 min, intraoperative blood volume was 150 to 700 ml, fluoroscopy frequency was 2 to 6, postoperative drainage flow was 60 to 195 ml, and the fracture healing time was 2.5 to 6.0 months. Fracture reduction was evaluated according to Matta score:anatomical reduction in 3 cases and satisfactory reduction in 8 cases. Eleven patients were followed up for 7 to 18 months. The hip Merle d'Aubigne function scores were excellent in 6 cases, good in 3 cases, fair in 1 case and poor in 1 case. Incision fat liquefaction occurred in 1 case and obturator nerve traction in 1 case.
CONCLUSION
The application of 3D printing technology combined with customized bone plates in the treatment of acetabular fracture is effective. In addition, the printed model can provide the operator with the results of the three-dimensional shape of the fracture, which is convenient for surgical reduction and effectively improves the efficiency of surgery.
Humans
;
Female
;
Male
;
Middle Aged
;
Acetabulum/surgery*
;
Printing, Three-Dimensional
;
Adult
;
Aged
;
Bone Plates
;
Fractures, Bone/surgery*
;
Fracture Fixation, Internal/methods*
10.A case-control study of shoulder arthroscopic double row and single row technique for the treatment of Ideberg type ⅠA scapular glenoid fracture.
Zhe-Yuan SHEN ; Rong WU ; Qiao-Ying PENG ; Heng LI ; Song-Hua GUO ; Zhan-Feng ZHANG
China Journal of Orthopaedics and Traumatology 2025;38(3):223-230
OBJECTIVE:
To compare clinical effect of arthroscopic double row fixation and single row fixation in treating Ideberg typeⅠA scapular glenoid fracture.
METHODS:
From June 2018 to December 2022, 26 patients with Ideberg typeⅠA scapular glenoid fracture treated with shoulder arthroscopy were divided into single-row anchor group and double-row anchor group according to the fixation method of fracture block. There were 12 patients in single-row anchor group, including 7 males and 5 females, aged from 25 to 53 years old with an average of (38.42±9.61) years old;the time from injury to operation ranged from 2 to 7 days with an average of (4.75±1.82) days. There were 14 patients in double-row anchor group, including 10 males and 4 females, aged from 21to 53 years old with an average of (37.36±10.19) years old;the time from injury to operation ranged from 1 to 8 days with an average of (4.21±2.01) days. The changes of shoulder joint flexion, abduction, lateral lateral rotation, Constant-Murley shoulder function score and Rowe scores were compared between two groups before operation and 1 year after operation. The percentage of bone mass in pelvis area before operation and the percentage of bone defect in pelvis area at the latest follow-up were compared between two groups.
RESULTS:
All patients were followed up for 12 to 15 months with an average of (13.08±1.17) months in single-row anchor group and 12 to 15 months with an average of (13.29±1.07) months in double-row anchor group, with no statistical significance between two groups (P>0.05). The results of anterior flexion, abduction and lateral lateral rotation in single-row anchor group were(86.67±6.62) °, (79.50±5.68) °, (38.17±1.70) ° before operation, and (162.50±4.52)°, (169.17±3.35)°, (50.67±10.20)° at 1 year after operation; while in double-row anchor group were (84.14±5.48) °, (81.71±5.20) °, (39.29±3.63) ° before operation and (162.29 ± 5.53) °, (167.14±3.61) °, (56.93±9.56) ° at 1 year after operation;the difference between two groups before operation and 1 year after operation was statistically significant (P<0.05). There were no significant difference between two groups (P>0.05). Constant-Murley scores and Rowe scores in single-row anchor group were (55.42±3.75), (43.75±18.49) before operation and (94.83±2.21), (95.42±4.50) at 1 year after operation, respectively;while in double-row anchor group were (54.50±7.88), (41.79±18.25) before operation and (94.36±4.73), (95.00±4.80) at 1 year after operation;there was no significant difference in Constant-Murley score and Rowe score between two groups before operation and 1 year after operation (P>0.05). There was significant difference in the percentage of bone mass in pelvis area between two groups before operation (P>0.05). There was no significant difference in the percentage of bone defect in the shoulder area between single-row anchor group(4.42±1.51)% and double-row anchor group (2.71±1.44)% at 1 year after operation (P<0.05).
CONCLUSION
Both single and double row fixation techniques for the treatment of Ideberg typeⅠA scapular glenoid fracture could receive satisfactory functional recovery. However, double-row fixation has more advantages in reducing bone resorption of fracture mass.
Humans
;
Female
;
Male
;
Middle Aged
;
Arthroscopy/methods*
;
Adult
;
Scapula/surgery*
;
Case-Control Studies
;
Fractures, Bone/physiopathology*
;
Fracture Fixation, Internal/methods*
;
Shoulder Joint/physiopathology*
;
Range of Motion, Articular

Result Analysis
Print
Save
E-mail