1.Biomechanical analysis of three kinds of rigid internal fixation methods for condylar head fractures.
Junhui SUN ; Duoduo LAN ; Dong WANG ; Yao XU ; Zeyu WANG ; Chenchen ZHANG ; Kai ZHANG ; Tao XU
West China Journal of Stomatology 2025;43(1):126-132
OBJECTIVES:
This study aims to analyze the biomechanics of three kinds of rigid internal fixation methods for condylar head fractures.
METHODS:
A three dimensional finite element model of the normal mandible was constructed. It was then used to prepare condylar head fracture finite element model and three kinds of rigid internal fixation finite element model (unilateral tension screw, bilateral tension screw, tension screw+titanium plate). The mechanical characteristics and changes of the mandible condyle under the same mechanical conditions were compared among the three different rigid internal fixation methods.
RESULTS:
The maximum equivalent stress and displacement of the non-free end of condyle under the rigid internal fixation method of unilateral tension screw were 71.03 MPa and 4.72 mm, respectively. The maximum equivalent stress and displacement of the free end of condyle were 78.45 MPa and 4.50 mm, respectively. The maximum stress of fracture suture was 3.27 MPa. The maximum equivalent stress and displacement of the non-free end of condyle under the rigid internal fixation method of bilateral tension screw were 70.52 MPa and 4.00 mm, respectively. The maximum equivalent stress and displacement of the free end of condyle were 72.49 MPa and 3.85 mm, respectively. The maximum stress of fracture suture was 2.33 MPa. The maximum equivalent stress and maximum displacement of the non-free end of condyle under the rigid internal fixation method of tension screw+titanium plate were 67.26 MPa and 2.66 mm, respectively. The maximum equivalent stress and maximum displacement of the free end of condyle were 69.66 MPa and 2.50 mm, respectively. The maximum stress of fracture suture was 2.18 MPa.
CONCLUSIONS
The tension screw+titanium plate rigid internal fixation method is the most conducive to biomechanical distribution for condylar head fractures.
Fracture Fixation, Internal/instrumentation*
;
Mandibular Condyle/surgery*
;
Biomechanical Phenomena
;
Bone Screws
;
Finite Element Analysis
;
Humans
;
Mandibular Fractures/surgery*
;
Bone Plates
;
Titanium
;
Stress, Mechanical
2.Novel approach of plate assisted buttressing in Hoffa fracture.
Amit SINGH ; Nirottam SINGH ; Gaurav SIWACH ; Mohit BANSAL ; Hemant JAIN ; Kishore RAICHANDANI
Chinese Journal of Traumatology 2025;28(3):175-180
PURPOSE:
Hoffa fracture is a femoral condyle fracture in the coronal plane. The lateral condyle is more commonly involved. The diagnosis is often difficult to detect with routine radiographs. Conservative management in this type of fracture resulted in nonunion, malunion, and other complications, such as stiff knee. Therefore, surgical management is mandatory in displaced fractures. Previous studies suggest only application of cancellous screw fixation, but these are not enough to counter vertical shear stress. Therefore, this study will evaluate the clinical outcomes of open reduction and internal fixation of Letenneur type I Hoffa fracture using cancellous screws with posterior buttressing plate.
METHOD:
This was a prospective cohort study conducted from March 2017 to July 2022 in orthopaedics department of tertiary care center after approval of institutional ethical committee. The study included 36 patients with Letenneur type I fractures treated by open reduction and internal fixation using posterior buttress plate and cancellous screws. Radiographs and clinical outcomes, range of movement (ROM), bone union, and knee society score (KSS) of patients were assessed at the end of 4 and 12 months in the follow-ups. All statistical analysis was done using Epi info version 7.2.1.0.
RESULTS:
In the 36 patients with Letenneur type I fracture, the majority belong to younger age group between 25 and 54 years with 22 males and 14 females. The modes of injury were road traffic accidents in 25 patients and fall from height in 11 patients. The right knee was involved in 21 cases and left was involved in 15 cases. Lateral condyle involvement was seen in 27 cases and medial condyle in 9 cases. All 36 patients with Letenneur type I Hoffa fracture were evaluated 4 months after surgical intervention. The notable improvements were observed in terms of ROM 120.4° ± 5.0° and KSS 85.0 ± 4.2. At the 12-month follow-up, considerably better outcomes were maintained regarding ROM 128.1° ± 5.2° and KSS 89.3 ± 4.8 with p < 0.05 which was statistically significant. At the final follow-up, all patients had routine fracture healing with a union time of (3.2 ± 3.4) months.
CONCLUSIONS
Fixation of Letenneur type I Hoffa fracture with cancellous screws and posterior buttress plate is effective, reliable and capable of providing adequate stability. Buttress plate assisted fixation is a valuable enhancement of the conventional technique of lag screw fixation of Hoffa fractures.
Humans
;
Bone Plates
;
Male
;
Female
;
Fracture Fixation, Internal/instrumentation*
;
Adult
;
Prospective Studies
;
Middle Aged
;
Femoral Fractures/surgery*
;
Bone Screws
;
Range of Motion, Articular
;
Young Adult
;
Aged
;
Hoffa Fracture
3.Comparative analysis of the safety and efficacy of fenestrated pedicle screw with cement and conventional pedicle screw with cement in the treatment of osteoporotic vertebral fractures: A meta-analysis.
Li CAO ; Hong-Jie XU ; Yi-Kang YU ; Huan-Huan TANG ; Bo-Hao FANG ; Ke CHEN
Chinese Journal of Traumatology 2025;28(2):101-112
PURPOSE:
Bone cement-reinforced fenestrated pedicle screws (FPSs) have been widely used in the internal fixation and repair of the spine with osteoporosis in recent years and show significant improvement in fixation strength and stability. However, compared with conventional reinforcement methods, the advantages of bone cement-reinforced FPSs remain undetermined. This article compares the effects of fenestrated and conventional pedicle screws (CPSs) combined with bone cement in the treatment of osteoporosis.
METHODS:
A clinical control study of FPSs and CPSs combined with bone cement reinforcement in osteoporotic vertebral internal fixation was performed using the database PubMed, Embase, Cochrane Library, CNKI, the Wanfang, and the China Biomedical Literature Service System. Two evaluators screened the relevant literature in strict accordance with the inclusion criteria (diagnosis of participants, type of clinical study, treatment with FPS and CPS, and outcome indicators) and exclusion criteria (duplicate literature and missing or incorrect data) and independently conducted data extraction and quality evaluation. Clinical control studies of direct comparison between FPS and CPS combined with bone cement reinforcement in patients who were definitively diagnosed with thoracolumbar fractures or spinal degenerative diseases were included. Quality evaluation was conducted using the Cochrane risk bias evaluation tool for randomized controlled studies and using the Newcastle-Ottawa scale for retrospective case-control studies. RevMan software (version 5.3) was used for the meta-analysis to compare the clinical efficacy, radiological results, and related complications of the 2 methods.
RESULTS:
A total of 13 articles were included, including 7 randomized controlled studies and 6 retrospective case-control studies. There were 909 patients in these studies, 451 in the FPS and polymethyl methacrylate (FPS & PMMA) group and 458 in the CPS and polymethyl methacrylate (CPS & PMMA) group. The results of the meta-analysis showed that there was no significant difference between the 2 groups in operation time, hospital stay, visual analogue score, Japanese orthopaedic association score, Oswestry disability index score, Cobb angle, vertebral body deformation index and fusion rate (p > 0.05). The mean difference of intraoperative bleeding volume was -10.45, (95% confidence intervals (CI) (-16.92, -3.98), p = 0.002), the mean difference of loss height of the anterior edge of the vertebral body after surgery was -0.69 (95% CI (-0.93, -0.44), p < 0.001), and the relative risk (RR) of overall complication rate was 0.43 (95% CI (0.27, 0.68), p < 0.001), including the RR of bone cement leakage rate was 0.57 (95% CI (0.39, 0.85), p = 0.005). The screw loosening rate (RR = 0.26, 95% CI (0.13, 0.54), p < 0.001) of the FPS group was significantly lower than that of the CPS group.
CONCLUSION
The existing clinical evidence shows that compared with the CPS combined with bone cement, the use of FPS repair in the internal fixation of an osteoporotic vertebral body can reduce the amount of intraoperative bleeding, be more conducive to maintaining the height of the vertebral body, and significantly reduce the incidence of postoperative complications such as bone cement leakage and screw loosening.
Humans
;
Pedicle Screws
;
Bone Cements
;
Spinal Fractures/surgery*
;
Osteoporotic Fractures/surgery*
;
Fracture Fixation, Internal/instrumentation*
4.Comparison of hook plates vs. locking plates for Neer type IIB fractures of lateral end clavicle: A systematic review.
Ravi PATEL ; Muhammad Murtaza KHAN ; William GIBSON ; Robin BANERJEE ; Asif PARDIWALA
Chinese Journal of Traumatology 2025;28(4):269-275
PURPOSE:
Surgical management of the lateral end of clavicle fractures has been a challenge for orthopedic surgeons considering the high rate of non-union. There has been no right and wrong answer to these types of fractures and many methods discussed in the literature, but the 2 most used bony procedures are hook plate and locking plate with or without the use of supplementary soft tissue procedures. The available evidence, in this case, is scarce with questionable reliability. The idea of this systemic review is to promote evidence-based practice when choosing between the 2 implants for this fracture. This study aims to review the results by performing a systemic review of the literature comparing the results of locking plate vs. hook plate for the lateral end of clavicle fracture fixation with an emphasis on outcome and associated complications.
METHODS:
A search of the literature was made with the keyword "clavicle" in PubMed/Ovid Medline/Embase and University of Edinburgh online library "discover Ed". A total of 4063 articles were identified including case series (with at least 3 cases) and review articles focusing on locking plate alone, comparisons of locking plate and hook plate, or hook plate alone. Articles were excluded if they were not published in English, focused on pediatric studies, or consisted only of book chapters. Studies examining tension band wiring, soft tissue procedures for fracture fixation, arthroscopic-assisted procedures, additional soft tissue procedures along with plate fixation, and fracture dislocation of the lateral end of the clavicle were also excluded. The search was then narrowed down to 21 articles after consideration of inclusion and exclusion criteria. A detailed review of the surgical methodology further excluded additional soft tissue procedures, resulting in a final selection of 15 studies. The quality of the studies was assessed using the Modified Coleman Score by the authors.
RESULTS:
A total of 15 studies related to Neer type II fracture met the inclusion criteria. However, 2 other studies also included type V fracture as well. The mean age of patients in these studies was 32 years. The mean follow-up period was 24.3 months (ranging from 6 to 65 months). The time of radiological union was documented from 2 to 4.5 months. Constant and disabilities of arm, shoulder, and hand scores were most used as the criteria for patient outcomes. The size of the lateral fragment that can accommodate/provide bicortical fracture was documented in only 3 studies. The mean incidence of removal of hook plate was 86.9%. In contrast, the mean incidence of removal of locking plate was 27.0%. Superficial wound infection was documented in 5 studies and deep wound infection was seen in 1 study. The mean union rate for hook plate was 97.0% compared to 100% for locking plate. Complications associated with hook plate have been documented in 11 studies. The most commonly reported incidence of complication was acromial osteolysis. The quality of studies was assessed using modified Coleman score. Other than 2 studies that were considered for the study that met the "fair" standard all of them were considered "poor" based on the modified Coleman score.
CONCLUSION
Both hook plate and locking plate provide acceptable operative treatment options for the lateral end of clavicle fracture. However, a consideration of surgeons' experience, the likelihood of a second operation, and the size of the lateral fragment should be considered when choosing between the 2 types of implants.
Humans
;
Clavicle/surgery*
;
Bone Plates
;
Fractures, Bone/surgery*
;
Fracture Fixation, Internal/instrumentation*
5.Early warning model of postoperative infection of internal fixation device in maxillofacial fracture based on the synthetic minority over-sampling technique algorithm.
Jinfeng JIANG ; Haiyan WANG ; Yanfeng SHI ; Ke XU
West China Journal of Stomatology 2025;43(6):837-844
OBJECTIVES:
This study investigates independent risk factors for postoperative internal fixation device infection in patients with maxillofacial fractures and proposes an early warning model based on the synthetic minority over-sampling technique (SMOTE) algorithm.
METHODS:
A total of 1 104 patients who underwent surgical treatment for maxillofacial fractures at Oral and Maxillofacial Surgery Department, Affiliated Hospital of Nantong University from January 2021 to December 2024 were retrospectively analyzed. The patients were divided into two groups based on the presence of postoperative internal fixation device infection: the infection group (27 cases) and non-infection group (1 077 cases). Clinical data from both groups were collected and subjected to statistical analysis. Univariate and binary Logistic regression analysis were used to identify risk factors for postoperative internal fixation device infection in maxillofacial fractures. Subsequently, a Logistic regression model was established, and the dataset was improved based on the SMOTE algorithm to construct an early warning model with the improved dataset. The prediction performance of the models was compared and validated.
RESULTS:
Among the 1 104 patients who underwent surgical treatment for maxillofacial fractures, 27 cases of postoperative internal fixation device infections were identified, corresponding to an infection rate of 2.45% (27/1 104). Age, diabetes history, fracture severity, and oral hygiene status were all identified as risk factors for postoperative internal fixation device infections in maxillofacial fractures (all P<0.05). The prediction model based on the original data (P1). The prediction model based on the SMOTE algorithm (P2). Receiver operating characteristic (ROC) curve analysis shows that the area under curve (AUC) for the P2 model was 0.882, the P1 model was 0.861, indicating the superior predictive performance of the P2 model. The DeLong test results show that the difference in AUC between the two models was statistically significant (P<0.05).
CONCLUSIONS
Age, diabetes history, postoperative fracture severity, and oral hygiene status are all risk factors for infections associated with internal fixation devices after maxillofacial fracture surgery. The proposed early warning model demonstrated good predictive performance. Medical professionals can utilize this model to effectively intervene and anticipate infections related to internal fixation devices after maxillofacial fracture surgery.
Humans
;
Algorithms
;
Retrospective Studies
;
Male
;
Female
;
Fracture Fixation, Internal/instrumentation*
;
Risk Factors
;
Middle Aged
;
Adult
;
Logistic Models
;
Surgical Wound Infection/epidemiology*
;
Aged
;
Internal Fixators/adverse effects*
;
Maxillofacial Injuries/surgery*
;
Adolescent
6.Three-dimensional binding treatment for avulsion fractures of inferior pole of patella utilizing suture anchor.
Hongqing HE ; Ningkai LI ; Meng LIU ; Jiating LIN ; Qiang WANG ; Yinchang ZHANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):26-31
OBJECTIVE:
To explore the feasibility and effectiveness of suture anchor double-pulley technique combined with suture three-dimensional binding via bone tunnel technique for avulsion fractures of the inferior pole of the patella.
METHODS:
A clinical data of 38 patients with avulsion fractures of the inferior pole of the patella, who met the selective criteria and were admitted between September 2021 and April 2023, was retrospectively analyzed. The fractures were treated with suture anchor double-pulley technique combined with suture three-dimensional binding via bone tunnel technique in 18 cases (group A) and steel wire tension-band fixation in 20 cases (group B). There was no significant difference in terms of age, gender, cause of fracture, side of fracture, and disease duration between the two groups ( P>0.05). The length of incision, operation time, occurrence of complications, the range of motion of knee joint, and Böstman score of knee joint at last follow-up were recorded. The fracture healing was evaluated through X-ray films and the time of fracture healing was recorded.
RESULTS:
All incisions healed by first intention. The length of incision was significantly shorter in group A than in group B ( P<0.05). There was no significant difference in the operation time between the two groups ( P>0.05). All patients were followed up 12-24 months (mean, 16.1 months). X-ray films showed that all fractures healed and there was no significant difference in the healing time between the two groups ( P>0.05). At last follow-up, the range of motion and Böstman score of the knee joint in group A were significantly better than those in group B ( P<0.05). During follow-up, 1 patient (5.6%) in group A had one anchor mild prolapse and 3 patients (15.0%) occured internal fixation irritation in group B. But there was no significant difference in the incidence of complications between the two groups ( P>0.05).
CONCLUSION
For the avulsion fractures of the inferior pole of the patella, the suture anchor double-pulley technique combined with suture three-dimensional binding via bone tunnel technique has advantages of reliable fixation, small incision, avoidance of secondary operation to remove internal fixator, and fewer complications, with definite effectiveness.
Humans
;
Male
;
Female
;
Patella/surgery*
;
Suture Anchors
;
Fracture Fixation, Internal/instrumentation*
;
Adult
;
Retrospective Studies
;
Middle Aged
;
Fractures, Avulsion/surgery*
;
Treatment Outcome
;
Young Adult
;
Range of Motion, Articular
;
Fracture Healing
;
Adolescent
;
Suture Techniques
;
Knee Joint/physiopathology*
7.TiRobot-assisted minimally invasive treatment of coracoid process fractures of scapula.
Yonghong DAI ; Qingyu LI ; Yanhui ZENG ; Zhengjie WU ; Chunpeng ZHAO ; Junqiang WANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):40-46
OBJECTIVE:
To explore effectiveness of TiRobot-assisted screw implantation in the treatment of coracoid process fractures of the scapula.
METHODS:
A retrospective analysis was conducted on the clinical data from 24 patients with coracoid process fractures of the scapula admitted between September 2019 and January 2024 and met selection criteria. Among them, 12 patients underwent TiRobot-assisted screw implantation (robot group) and 12 underwent manual screw implantation (control group) during internal fixation. There was no significant difference ( P>0.05) in baseline data such as gender, age, body mass index, disease duration, cause of injury, coracoid process fracture classification, and proportion of patients with associated injuries between the two groups. The incision length, operation time, intraoperative blood loss, hospital stay, accuracy of screw placement, coracoid process fracture healing time, and complications were recorded and compared, as well as pain visual analogue scale (VAS) score, and Constant-Murley score at last follow-up.
RESULTS:
The intraoperative blood loss and incision length in the robot group were significantly lower than those in the control group ( P<0.05); however, there was no significant difference in operation time and hospital stay between the two groups ( P>0.05). All patients were followed up 8-27 months (mean, 17.5 months), and the difference in follow-up time between the two groups was not significant ( P>0.05). At last follow-up, the VAS score for shoulder pain in the robot group was signifncatly lower compared to the control group, and the Constant-Murley score was significantly higher ( P<0.05). In the robot group, 16 screws were implanted intraoperatively, while 13 screws were implanted in the control group. Radiographic re-evaluation showed that the excellent and good rate of screw implantation was higher in the robot group (93.8%, 15/16) than in the control group (61.5%, 8/13), but the difference in the precision of screw implantation between the two groups was not significant ( P>0.05). Four patients in the robot group and 1 in the control group achieved double screws fixation; however, the difference in achieving double screws fixation between the two groups was not significant ( P>0.05). All fractures healed in both groups with 1 case of malunion in the control group. There was no significant difference in healing time between the two groups ( P>0.05). During follow-up, 1 patient in the control group experienced screw loosening and displacement. There was no significant difference in the incidence of screw loosening and fracture malunion between the two groups ( P>0.05).
CONCLUSION
Compared with manual screw implantation, TiRobot-assisted minimally invasive treatment of coracoid process fractures of the scapula can reduce intraoperative blood loss, shorten incision length, alleviate pain, and obtain better promote shoulder joint functional recovery.
Humans
;
Male
;
Female
;
Retrospective Studies
;
Fracture Fixation, Internal/instrumentation*
;
Minimally Invasive Surgical Procedures/instrumentation*
;
Adult
;
Middle Aged
;
Fractures, Bone/surgery*
;
Bone Screws
;
Coracoid Process/surgery*
;
Robotic Surgical Procedures/methods*
;
Scapula/surgery*
;
Treatment Outcome
;
Operative Time
;
Young Adult
;
Length of Stay
;
Blood Loss, Surgical
8.Treatment of irreducible intertrochanteric femoral fractures in elderly by novel bone hook combined with finger-guided technique.
Zenghui ZHANG ; Tichao HAN ; Wei LI ; Yangyang ZHOU ; Junjun LIU ; Nannan LI ; Tiantian REN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):53-58
OBJECTIVE:
To investigate the feasibility and effectiveness of the novel bone hook combined with finger-guided technique in the treatment of irreducible intertrochanteric femoral fractures in elderly.
METHODS:
Between January 2021 and August 2023, 23 elderly patients with irreducible intertrochanteric femoral fractures were treated with the novel bone hook combined with finger-guided technique. There were 10 males and 13 females; the age ranged from 68 to 93 years (mean, 76.2 years). The time from injury to operation ranged from 36 to 76 hours (mean, 51.2 hours). According to the classification standard proposed by TONG Dake et alin 2021, there were 10 cases of typeⅠA, 1 case of typeⅠB, 6 cases of type ⅡA, 4 cases of type ⅡB, and 2 cases of type ⅡC. The operation time, intraoperative blood loss, intraoperative fluoroscopy frequences, and quality of fracture reduction were recorded. The fracture healing time and occurrence of postoperative complications were observed during follow-up. At last follow-up, the Harris scoring system was used to evaluate the hip joint function.
RESULTS:
The operation time was 42-95 minutes (mean, 52.1 minutes). The intraoperative blood loss was 40-420 mL (mean, 126.5 mL). Intraoperative fluoroscopy was performed 14-34 times (mean, 20.7 times). According to the criteria proposed by Chang et al, the quality of fracture reduction was rated as good in 20 cases and acceptable in 3 cases. All patients were followed up 6-20 months (mean, 10.2 months). X-ray film showed that all fractures healed with the healing time of 3.0-5.5 months (mean, 4.0 months). At last follow-up, the Harris score of the hip joint ranged from 82 to 97 points (mean, 90.4 points). Among them, 14 cases were rated as excellent and 9 cases as good. No complication such as coxa vara, cutting of the cephalomedullary nail, nail withdrawal, or nail breakage occurred during follow-up.
CONCLUSION
The treatment of elderly patients with irreducible intertrochanteric femoral fractures by using the novel bone hook combined with finger-guided technique can achieve high-quality fracture reduction and fixation, and has a good effectiveness.
Humans
;
Male
;
Female
;
Aged
;
Aged, 80 and over
;
Hip Fractures/diagnostic imaging*
;
Fracture Fixation, Internal/instrumentation*
;
Fracture Healing
;
Treatment Outcome
;
Operative Time
;
Fracture Fixation, Intramedullary/instrumentation*
;
Bone Nails
;
Postoperative Complications/epidemiology*
;
Feasibility Studies
;
Fingers
9.Comparison of effectiveness between two surgical methods for humeral lateral condyle fractures in children.
Hailong MA ; Qingjie WU ; Fang LIU ; Zhongtuo HUA ; Sicheng ZHANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):64-69
OBJECTIVE:
To compare the effectiveness of ultrasound-guided closed reduction with Kirschner wire fixation and open reduction with Kirschner wire fixation in the treatment of humeral lateral condyle fracture (HLCF) in children.
METHODS:
A clinical data of 53 children with HLCF admitted between May 2020 and April 2023 and met selective criteria was retrospectively analyzed. Of these, 25 cases were managed with closed reduction and Kirschner wire fixation under ultrasound guidance (closed group), while 28 cases underwent open reduction and Kirschner wire fixation (open group). There was no significant difference between the two groups in terms of gender, age, cause of injury, fracture side, fracture classification, and time from injury to operation ( P>0.05). The following variables were recorded and compared between the two groups: operation time, intraoperative fluoroscopy frequency, fracture healing time, incidence of complications, and the Flynn elbow function score at last follow-up.
RESULTS:
In the closed group, the fractures were successfully reduced under ultrasound guidance, with no nerve damage reported in either group. The operation time and intraoperative fluoroscopy frequency were significantly less in the closed group than in the open group ( P<0.05). One case of infection (Kirschner wire irritation) was observed in the closed group, while 3 cases in the open group (2 of Kirschner wire irritation and 1 of incision infection). However, the difference in the incidence of infection between the two groups was not significant ( P>0.05). All patients in both groups were followed up 6-18 months (mean, 10.2 months). X-ray examinations confirmed that fractures had healed in both groups, with no significant difference in healing time ( P>0.05). During follow-up, 5 cases of lateral humeral process formation were observed in the closed group, compared to 12 cases in the open group, although this difference was not significant ( P>0.05). At last follow-up, the excellent and good rate of elbow joint function was evaluated as 96.0% (24/25) in the closed group and 92.9% (26/28) in the open group according to the Flynn scoring criteria, with no significant difference between the two groups ( P>0.05). Both groups showed no occurrence of ossifying myositis or elbow internal/external rotation.
CONCLUSION
The effectiveness of ultrasound-guided closed reduction and Kirschner wire fixation in the treatment of HLCF in children is comparable to open reduction and Kirschner wire fixation, but the former can reduce operation time and intraoperative fluoroscopy frequency, and obtain lower the incidence of complications.
Humans
;
Humeral Fractures/diagnostic imaging*
;
Bone Wires
;
Male
;
Female
;
Child
;
Retrospective Studies
;
Fracture Fixation, Internal/instrumentation*
;
Treatment Outcome
;
Child, Preschool
;
Open Fracture Reduction/methods*
;
Fracture Healing
;
Elbow Joint/surgery*
;
Adolescent
;
Closed Fracture Reduction/methods*
;
Fluoroscopy
;
Operative Time
10.Application of elbow skin fold extension line in extreme elbow flexion in ulnar Kirschner wire insertion of extended supracondylar humeral fractures in children.
Xu LIU ; Wei WU ; Yuzhou SHAN ; Guanghui YANG ; Ming CHEN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):70-74
OBJECTIVE:
To discuss the elbow skin fold extension line in Kirschner wire internal fixation of extended supracondylar humeral fractures in children.
METHODS:
The clinical data of 58 children with extended supracondylar fractures of the humerus who met the selection criteria between August 2021 and July 2024 were retrospectively analyzed. In 28 cases, needle placement of medial epicondyle of humerus was performed with the assistance of the elbow skin fold extension line (study group), and 30 cases were assisted by routine touch of the medial epicondyle of the humerus (control group). There was no significant difference in baseline data such as gender, age, side, cause of injury, Gartland type, Kirschner wire configuration, and time from injury to operation between the two groups ( P>0.05). The closed reduction rate, total operation time, time of medial humeral condyle pin placement, fluoroscopy times during medial pin placement, rate of one-time determination of medial entry point, ulnar nerve injury incidence, and fracture healing time were recorded and compared between the two groups. At the same time, the closed reduction rate of patients with the time from injury to operation ≤24 hours and >24 hours was compared. The elbow function was evaluated by Mayo elbow function score.
RESULTS:
The closed reduction rate of the study group was significantly higher than that of the control group ( P<0.05). Among all patients, the closed reduction rate of patients with the time from injury to operation ≤24 hours [73.3% (22/30)] was significantly higher than that of patients >24 hours [42.9% (12/28)] ( χ 2=5.545, P=0.019). The total operation time, medial needle placement time, and fluoroscopy times in the study group were significantly less than those in the control group, and the one-time determination rate of medial needle entry point in the study group was significantly higher than that in the control group ( P<0.05). There were 4 cases of ulnar nerve injury in the control group, and no ulnar nerve injury in the study group, but there was no significant difference in the incidence of ulnar nerve injury between the two groups ( P>0.05). All patients were followed up 6-12 months (mean, 8 months). There was no bone nonunion in both groups, and the fracture healing time of the study group was significantly shorter than that of the control group ( P<0.05). Volkmann ischemic contracture, heterotopic ossification, myositis ossificans, and premature epiphyseal closure were not observed after operation. No complications such as loosening or fracture of Kirschner wire occurred. At last follow-up, the Mayo elbow joint function score was used to evaluate function, and there was no significant difference between the two groups ( P>0.05).
CONCLUSION
In the treatment of extended supracondylar fractures of the humerus in children, the elbow skin fold extension line can help to quickly locate the medial epicondyle of the humerus, quickly insert Kirschner wire, and reduce the operation time and trauma.
Humans
;
Humeral Fractures/surgery*
;
Bone Wires
;
Male
;
Female
;
Fracture Fixation, Internal/instrumentation*
;
Retrospective Studies
;
Child
;
Elbow Joint/physiopathology*
;
Child, Preschool
;
Treatment Outcome
;
Fracture Healing
;
Ulnar Nerve/injuries*
;
Adolescent
;
Range of Motion, Articular

Result Analysis
Print
Save
E-mail