1.Emergency reconstruction of traumatic dynamic muscle defects using functional superficial vastus lateralis chimeric perforator flap based on descending branch of lateral femoral circumflex artery.
Yuqi ZHENG ; Xiaoju ZHENG ; Haijun LI
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(9):1128-1136
OBJECTIVE:
To investigate the feasibility and clinical outcomes of emergency reconstruction of traumatic dynamic muscle defects using functional superficial vastus lateralis chimeric perforator flap based on descending branch of lateral femoral circumflex artery.
METHODS:
A retrospective analysis was conducted of 10 patients with traumatic dynamic muscle defects treated between March 2020 and April 2024. There were 8 males and 2 females, aged 23-52 years (mean, 36.7 years). Injuries included 7 cases of Gustilo type ⅢB forearm trauma (2 with flexor muscle group defects, 3 with extensor muscle group defects, and 2 with combined flexor and extensor muscle group defects), 1 case of right first metacarpal defect with concomitant thenar muscle and skin defect, 1 case of complete transection of the right upper arm musclecutaneous nerve extracted from the biceps brachii muscle, and 1 case of Gustilo type ⅢC lower-limb trauma with extensor hallucis longus and toe extensor defects. Soft tissue defects ranged from 10 cm×8 cm to 36 cm×11 cm. Preoperative musculoskeletal ultrasound of the contralateral side was used to measure cross-sectional area, length, and pennation angle of the target muscles. Based on these parameters, anterolateral thigh flaps combined with one or two superficial vastus lateralis muscle segments were designed and transplanted to the recipient sites. The grafts were used to cover wounds, reconstruct major missing muscle groups, and were fixed in place. Vascular and neural anastomoses were performed simultaneously with repair of bone and soft tissue injuries to restore limb perfusion and function. Postoperative evaluation included musculoskeletal ultrasound, electrophysiology, and dynamic assessment of muscle strength during follow-up.
RESULTS:
All transplanted muscles and flaps survived primarily without vascular or neural complications. All the 10 patients were followed up 10-38 months, with an average of 22.8 months. The muscle strength recovery reached M5 in 6 cases, M4 in 3 cases, and
Humans
;
Male
;
Adult
;
Female
;
Perforator Flap/blood supply*
;
Plastic Surgery Procedures/methods*
;
Retrospective Studies
;
Soft Tissue Injuries/surgery*
;
Middle Aged
;
Quadriceps Muscle/transplantation*
;
Femoral Artery/surgery*
;
Young Adult
;
Muscle, Skeletal/surgery*
;
Treatment Outcome
;
Forearm Injuries/surgery*
2.The clinical outcomes of using superficial circumflex iliac artery perforator flap and radial forearm free flap for reconstructing oral and maxillofacial soft tissue defects.
Changquan WANG ; Tianbin HUANG ; Shanbin GUAN ; Guangru HUANG ; Xiaoyuan CHENG ; Liushan LU
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2025;39(6):534-541
Objective:To compare the clinical outcomes of reconstruction of oral and maxillofacial soft tissue defects using superficial circumflex iliac artery perforator flap (SCIA PF) and radial forearm free flap (RFF). Methods:A retrospective analysis was conducted on 90 patients with head, neck, and maxillofacial tumors who were treated in our department from June 2019 to January 2024. Patients were divided into two groups based on the surgical method used: the SCIA group(n=45), who underwent reconstruction with SCIA PF, and the RFF group(n=45), who received RFF reconstruction. Six months postoperatively, clinical efficacy was evaluated by comparing flap swelling, flap survival rate, and patient satisfaction. Oral function was assessed using standardized scoring systems before surgery, at 1 week, 3 months, and 6 months post-surgery. Hemorheological parameters, including high-shear viscosity(shear rate 200/s), low-shear viscosity(shear rate 30/s), plasma viscosity, erythrocyte aggregation index, and erythrocyte sedimentation rate(ESR), were also measured at each time point. Results:Compared with the RFF group, the SCIA group showed significantly larger flap size, longer flap harvesting and reconstruction times, earlier nasogastric tube removal and oral intake initiation, higher scores in all aspects of oral function, reduced flap edema and faster resolution, higher flap survival rates, and greater overall satisfaction (all P<0.05). During the follow-up period (preoperative, 1 week, 3 months, and 6 months post-surgery), hemorheological indices including high-and low-shear viscosity, plasma viscosity, erythrocyte aggregation index, and ESR progressively decreased in the SCIA group (P<0.05). In the RFF group, these parameters improved significantly by 6 months postoperatively compared with preoperatively and 1-week postoperatively, with a notable decrease in erythrocyte aggregation index at 6 months (P<0.05). Conclusion:Compared with RFF, SCIA PF provides larger flaps, better functional recovery, higher patient satisfaction, improved flap survival, fewer complications, and more favorable hemorheological profiles following reconstructive surgery for oral and maxillofacial defects.
Humans
;
Perforator Flap/blood supply*
;
Plastic Surgery Procedures/methods*
;
Retrospective Studies
;
Free Tissue Flaps
;
Iliac Artery/transplantation*
;
Forearm/surgery*
;
Male
;
Female
;
Soft Tissue Injuries/surgery*
;
Head and Neck Neoplasms/surgery*
;
Middle Aged
;
Treatment Outcome
;
Adult
3.Intramedullary compression device for proximal ulna fracture.
Choon Chiet HONG ; Fucai HAN ; Joshua DECRUZ ; Vinodhkumar PANNIRSELVAM ; Diarmuid MURPHY
Singapore medical journal 2015;56(2):e17-20
Proximal ulna fractures account for 20% of all proximal forearm fractures. Many treatment options are available for such fractures, such as cast immobilisation, plate and screw fixation, tension band wiring and intramedullary screw fixation, depending on the fracture pattern. Due to the subcutaneous nature of the proximal forearm, it is vulnerable to open injuries over the dorsal aspect of the proximal ulna. This may in turn prove challenging, as it is critical to obtain adequate soft tissue coverage to reduce the risk of implant exposure and bony infections. We herein describe a patient with a Gustillo III-B open fracture of the proximal ulna, treated with minimally invasive intramedullary screw fixation using a 6.0-mm cannulated headless titanium compression screw (FusiFIX, Péronnas, France).
Adult
;
Bone Screws
;
Forearm Injuries
;
surgery
;
Fracture Fixation, Internal
;
methods
;
Fracture Fixation, Intramedullary
;
methods
;
Fracture Healing
;
Fractures, Open
;
surgery
;
Humans
;
Male
;
Radius Fractures
;
Range of Motion, Articular
;
Titanium
;
Ulna Fractures
;
surgery
4.Comparison of Ultrasound-Guided Axillary Brachial Plexus Block Techniques: Perineural Injection versus Single or Double Perivascular Infiltration.
Sooyoung CHO ; Youn Jin KIM ; Hee Jung BAIK ; Jong Hak KIM ; Jae Hee WOO
Yonsei Medical Journal 2015;56(3):838-844
PURPOSE: We compared three methods of ultrasound-guided axillary brachial plexus block, which were single, and double perivascular (PV) infiltration techniques, and a perineural (PN) injection technique. MATERIALS AND METHODS: 78 patients of American Society of Anesthesiologists physical status I-II undergoing surgery of the forearm, wrist, or hand were randomly allocated to three groups. 2% lidocaine with epinephrine 5 microg/mL was used. The PN group (n=26) received injections at the median, ulnar, and radial nerve with 8 mL for each nerve. The PV1 group (n=26) received a single injection of 24 mL at 12-o'clock position of the axillary artery. The PV2 group (n=26) received two injections of 12 mL each at 12-o'clock and 6-o'clock position. For all groups, musculocutaneous nerve was blocked separately. RESULTS: The PN group (391.2+/-171.6 sec) had the longest anesthetic procedure duration than PV1 (192.8+/-59.0 sec) and PV2 (211.4+/-58.6 sec). There were no differences in onset time. The average induction time was longer in PN group (673.4+/-149.6 sec) than PV1 (557.6+/-194.9 sec) and PV2 (561.5+/-129.8 sec). There were no differences in the success rate (89.7% vs. 86.2% vs. 89.7%). CONCLUSION: The PV injection technique consisting of a single injection in 12-o'clock position above the axillary artery in addition to a musculocutaneous nerve block is equally effective and less time consuming than the PN technique. Therefore, the PV technique is an alternative method that may be used in busy clinics or for difficult cases.
Adult
;
Anesthetics, Local/*administration & dosage/adverse effects
;
Brachial Plexus/*drug effects/*ultrasonography
;
Brachial Plexus Block/adverse effects/*methods
;
Female
;
Forearm/surgery
;
Hand/surgery
;
Humans
;
Injections
;
Male
;
Middle Aged
;
Peripheral Nerves/ultrasonography
;
Prospective Studies
;
Single-Blind Method
;
Treatment Outcome
;
*Ultrasonography, Interventional
;
Upper Extremity/innervation/*surgery
;
Vascular System Injuries/etiology
;
Wrist/surgery
5.The middle-forearm flap based on perforator of ulnar artery for electrical burn wound on the wrist .
Chu GUOPING ; Yang MINLIE ; Yu SHUN ; Qin HONGBO ; Zhao QINGGUO ; Su QINGHE ; Lyu GUOZHONG
Chinese Journal of Plastic Surgery 2014;30(5):346-348
OBJECTIVETo dicuss the application and therapeutic effect of middle-forearm flap based on perforator of ulnar artery for electrical burn wound on the wrist.
METHODSFrom Oct. 2009 to Oct. 2012, 10 cases of electrical burn wounds on the wrist were treated. A line from radialis medial epicondyle of humerus to the interior radialis pisiform bone was connected as flap axis. At the midpoint of the line, Doppler flow imaging meter was used to detect the emerging point of perforator vessel. The flap was designed and harvested. The flap was transferred reversely, with superficial vein retaining which was anastomosed with vein at recipient sites in 3 cases. The wounds in the donor sites were closed directly in 2 cases, and with skin graft in 8 cases.
RESULTSAll the 10 flaps survived completely. 7 cases without vein anastomosis underwent obvious flap edema during 2-4 days postoperatively, which resovled 1 week later. Sub-flap tissue necrosis and infection happened in 2 cases, which healed after dressing and drainage. Patients were followed up for 3-36 months with satisfactory results.
CONCLUSIONSThe middle-forearm flap based on perforator of ulnar artery has a stable and reliable blood supply. It offers a new choice for the electric burn wound on the wrist, especially at the ulnar side.
Burns, Electric ; surgery ; Forearm ; Humans ; Reconstructive Surgical Procedures ; Skin Transplantation ; Surgical Flaps ; blood supply ; transplantation ; Ulnar Artery ; Wrist Injuries ; surgery
6.Manual reduction of children's Monteggia fractures associated with anterior interosseous nerve injury.
China Journal of Orthopaedics and Traumatology 2014;27(10):862-865
OBJECTIVETo study clinical results of the manual reduction in treatment.
METHODSFrom October 2010 to April 2013,39 children with Monteggia fracture associated with anterior interosseous nerve injury were treated by manual reduction and fixation on buckling rotation backward,including 17 females and 22 males with an average age of 6.3 years old ranging from 3.2 to 11 years old. Among them, 15 cases were on the right side and 24 cases on the left. The course of disease was 40 minutes to 8 days (averaged 1.5 days). There were 7 cases with skateboard injured, 13 cases with stumble injured, 11 cases with falling injured,8 cases with air bed injured. According to Bado classification, 13 cases were type II, 22 cases were type III, 4 cases were type IV.
RESULTSThe distal forefinger showed exercise normally in 34 cases at 3 weeks after treatment, and the patients restored normal activities at 6 weeks after treatment. All patients were follow-up from 54 days to 6 months (averaged 67 days. According to Mayo elbow functional evaluation standard,the scoring result was 19.62±1.35 in activity, 45.00 ± 0.00 in pain, 9.87 ± 0.80 in stability, 25.00±0.00 in strength, 99.49 ±1.92 in total. The outcome of all patients was excellent and good evaluation results.
CONCLUSIONIf the anterior interosseous nerve injury could be identified early and treated timely, patients could gradually restore reasonable function and recover with satisfactory results. Raising understanding of anterior interosseous nerve injury can effectively reduce misdiagnosis.
Arm Bones ; injuries ; innervation ; surgery ; Child ; Child, Preschool ; Female ; Forearm Injuries ; surgery ; Fracture Fixation, Internal ; Humans ; Male ; Median Nerve ; injuries ; Monteggia's Fracture ; surgery
7.The clinical application of superficial circumflex iliac artery flaps.
Guo-Hong BAO ; Chao-Shuai HUANG ; Xiao-Ping ZHU
Chinese Journal of Plastic Surgery 2013;29(6):440-443
OBJECTIVETo investigate the clinical application of pedicled superficial circumflex iliac artery (SCIA) flaps in Burns and Plastic Surgery.
METHODS19 cases with skin and soft tissue defects were repaired with the Superficial circumflex iliac artery flaps. The defects located in the hand and forearm, the lower abdomen and perineal area, the radicle area of thigh, etc. Before the SCIA flaps were transfered to the recipient areas, 15 cases with different kinds of wounds were debrided thoroughly, 3 cases with scar were removed directly. The size of the flaps ranged from 3.0 cm x 4.5 cm to 26.0 cm x 22.0 cm, and the pedical was 5 cm to 7 cm in length.
RESULTSThe flaps in the 18 cases survived completely. Skin necrosis in the distal end of the flap appeared in 1 case, and the wound healed after the second repair. The follow-up period rang from 3 to 18 months. The apperance and function of the hand or foot was satisfactory.
CONCLUSIONSBecause the pedicled SCIA flaps can be obtain conveniently and contain sufficient blood-supply, so the flap is easy to survive and the flap can be designed in a large size. We believe it is an ideal method to use this flap to repair skin and soft tissue defects located in hands, forearms, the lower abdomen and perineal areas, the radicle area of thigh and so on.
Burns ; surgery ; Forearm ; Graft Survival ; Hand ; Humans ; Iliac Artery ; Necrosis ; Reconstructive Surgical Procedures ; Soft Tissue Injuries ; surgery ; Surgical Flaps ; blood supply ; pathology ; transplantation ; Thigh ; Wound Healing
8.Perforator flap in the middle segment of posterolateral forearm for dorsal defects at the lower forearm.
Jian LIN ; Yun-Lan YU ; He-Ping ZHENG
Chinese Journal of Plastic Surgery 2012;28(5):325-328
OBJECTIVETo discuss the feasibility of perforator flaps in the middle segment of posterolateral forearm for dorsal defects at the lower forearm.
METHODS30 specimens of adult upper limbs, perfused with red latex, were dissected. The course, origin, distribution and branches of major perforator artery in the middle segment of posterolateral forearm were observed and measured. 8 cases with dorsal defects at the lower forearm were treated with the perforator flaps.
RESULTSAll the 8 flaps survived completely with primary healing. The patients were followed up for 2-28 months with good flap texture, color and appearance.
CONCLUSIONSThe perforator flap in the middle segment of posterolateral forearm has constant and rich blood supply which is originated from the main artery. It is suitable for defects at the dorsal side of lower forearm.
Adolescent ; Adult ; Aged ; Female ; Forearm ; surgery ; Forearm Injuries ; surgery ; Humans ; Male ; Middle Aged ; Perforator Flap ; Soft Tissue Injuries ; surgery ; Young Adult
9.Reconstruction of soft-tissue defects in hands using the free proximal posterior interrosseous artery forearm perforator flaps.
Xin WANG ; Jia-Dong PAN ; Hong CHEN ; Hao-Liang HU ; Sheng-Wei WANG ; Ke-Jie WANG ; Wei-Wen ZHANG
Chinese Journal of Plastic Surgery 2012;28(2):83-87
OBJECTIVETo investigate the applied anatomy of the proximal posterior interrosseous artery perforator flap (PIAP) and report the clinical results of repairing the soft tissue defects in hands.
METHODSBetween September 2007 and January 2011, 21 patients with 24 soft tissue defects in hands were repaired with the free proximal PIAP flap transplantation. The size of the flaps ranged from 2.0 cm x 1.5cm to 7cm x 5cm. The longest length of these flaps was 9 cm. 9 flaps were dissected with one additional superficial vein to anastomose with the superficial vein at the recipient sites.
RESULTS19 flaps survived completely. Bubbles and violet color happened in 4 flaps which survived finally after partial suture removal. Flap necrosis occurred in one flap. The clinical results were satisfactory after 6-25 months of following-up, and the scars at the donor sites were not obvious.
CONCLUSIONSThe free PIAP flaps have constant, reliable blood supply, and good texture. It is a good option for repairing soft-tissue defects in the hands.
Forearm ; Graft Survival ; Hand Injuries ; surgery ; Humans ; Perforator Flap ; blood supply ; transplantation ; Soft Tissue Injuries ; surgery ; Surgical Flaps
10.Repair of soft tissue defects in the upper limbs using multiple types of posterior interosseous artery flaps.
Gang LIANG ; Jian DING ; Jian-ping SUN ; Bao-cheng XU ; Yun-feng GU
Chinese Journal of Plastic Surgery 2011;27(1):23-27
OBJECTIVETo summarize the therapeutic effect of multiple types of posterior interosseous artery flaps for repair of soft tissue defects in the upper extremities.
METHODSFrom March 2003 to June 2010, 42 cases with soft tissue defects in the upper limbs resulting from burn and traumatic injuries were treated using multiple types of posterior interosseous artery flaps, including retrograde flaps and composite flaps, antegrade flaps ,and free flaps. Flap size ranged from 2.5 cm x 2.0 cm-14.0 cm x 9.0 cm. The defects in the donor sites were closed directly or covered by skin graft.
RESULTSThe conventional retrograde posterior interosseous artery flaps were used in 11 cases, the modified retrograde posterior interosseous artery flaps were used in 13 cases, the retrograde posterior interosseous artery composite flaps incorporating partial extensors were used in 2 cases, the antegrade posterior interosseous artery flaps were used in 3 cases, the free posterior interosseous artery flaps were used in 7 cases, and the free perforator flap based on the radiodorsal septocutaneous perforator of the posterior interosseous artery were used in 6 cases. Partial necrosis happened in one case at the distal portion of the flap. Muscular branch of the posterior interosseous nerve was injured in one case with conventional reverse posterior interosseous artery flaps. All the other flaps survived uneventually with no complication. All wounds were primarily healed. 32 cases were followed up for 1 to 48 months with satisfactory aesthetic and functional results both in the donor sites and in the recipient areas. The color,texture and thickness of the flaps were satisfied as well.
CONCLUSIONSThe posterior interosseous artery flap has a constant vascular anatomy and a great flexibility, which is practical and suitable for repair of Soft tissue defect in the upper extremities arising from burn and traumatic injury.
Adolescent ; Adult ; Burns ; surgery ; Female ; Forearm ; surgery ; Humans ; Male ; Middle Aged ; Retrospective Studies ; Skin Transplantation ; Soft Tissue Injuries ; surgery ; Surgical Flaps ; blood supply ; Treatment Outcome ; Young Adult

Result Analysis
Print
Save
E-mail