1.Co-infection of Dirofilaria immitis and Japanese encephalitis virus in a spotted seal (Phoca largha) in the Republic of Korea
Ji Youl JUNG ; Hyun Jeong KIM ; Kyunghyun LEE ; Jun Gu CHOI ; Yeon Hee KIM ; Kyoung Ki LEE ; Young dae KIM ; ByungJae SO ; Hae Eun KANG ; Eun Jin CHOI
Journal of Veterinary Science 2019;20(6):e65-
A 10-year-old male spotted seal presented with loss of appetite and decreased activity. Grossly, the internal organs revealed several filarial nematodes in the right ventricle of the heart and the pulmonary vessels. Histopathological examination of the brain revealed moderate nonsuppurative meningoencephalitis with glial nodules and neuronophagia. Japanese encephalitis virus (JEV) of genotype I was isolated from the brain. All nematodes were identified as Dirofilaria immitis. This is the first clinical case of co-infection with D. immitis and JEV in a seal, suggesting that the seal, may be a dead-end host, like the human and horse, for JEV.
Appetite
;
Asian Continental Ancestry Group
;
Brain
;
Child
;
Coinfection
;
Dirofilaria immitis
;
Dirofilaria
;
Encephalitis Virus, Japanese
;
Encephalitis, Japanese
;
Genotype
;
Heart
;
Heart Ventricles
;
Horses
;
Humans
;
Male
;
Meningoencephalitis
;
Republic of Korea
2.Distinct Inflammation Biomarkers in Healthy Individuals and Patients with Schizophrenia: A Reliability Testing of Multiplex Cytokine Immunoassay by Bland-Altman Analysis
Ta Chuan YEH ; Hsuan Te CHU ; Chia Kuang TSAI ; Hsin An CHANG ; Fu Chi YANG ; San Yuan HUANG ; Chih Sung LIANG
Psychiatry Investigation 2019;16(8):607-614
OBJECTIVE: Since the inflammatory process has been implicated in the pathophysiology of psychiatric disorder, an important issue emerging is to assess the test-retest reliability of cytokine measurement in healthy individuals and patients with schizophrenia. The objective of the present study was to investigate the test-retest reliability of bead-based multiplex immunoassay technology (BMIT) for cytokine measurement by using a Bland-Altman plot (BAP). METHODS: Twenty healthy individuals and twenty patients with schizophrenia were enrolled, and a 17-plex cytokine assay was used to measure inflammatory biomarkers at baseline and two weeks later. The test-retest reliability was examined by BAP, 95% limits of agreement (LOA), intraclass correlation coefficient (ICC), and coefficient of repeatability (CoR). RESULTS: In the healthy controls, only interleukin (IL)-2, IL-13, IL-10, IL-17, and macrophage inflammatory protein-1β showed excellent ICC. The BAP with 95% LOA determined that 13 cytokines showed acceptable 95% LOA for a 2-week test-retest reliability, and only IL-1β, IL-12 and tumor necrosis factor (TNF)-α had significant test-retest bias. The CoR of cytokines varied significantly, ranging from 1.72 to 218.1. Compared with healthy controls, patients with schizophrenia showed significantly higher levels of IL-5, IL-13, and TNF-α and significantly lower levels of IL-4, IL-12, and interferon-gamma (IFN-γ). Of these six cytokines, IL-12 and TNF-α were considered suboptimal reliability. CONCLUSION: The findings from ICC and CoR implied that the test-retest reliability of BMIT for cytokine measurement were suboptimal. However, the BAP with 95% LOA confirmed that BMIT can reliably distinguish schizophrenia from healthy individuals in cytokine measurement, while significant within-subject variation and between-group overlapping were evident in cytokine expression.
Bias (Epidemiology)
;
Biomarkers
;
Cytokines
;
Humans
;
Immunoassay
;
Inflammation
;
Interferon-gamma
;
Interleukin-10
;
Interleukin-12
;
Interleukin-13
;
Interleukin-17
;
Interleukin-4
;
Interleukin-5
;
Interleukins
;
Loa
;
Macrophages
;
Reproducibility of Results
;
Schizophrenia
;
Tumor Necrosis Factor-alpha
3.Ectopic migration of Dirofilaria immitis in a Eurasian otter (Lutra lutra) in Korea
Ji Youl JUNG ; Kyunghyun LEE ; Hyun Ji SEO ; Yun Sang CHO ; Young Dae KIM ; Ji Hyeon KIM ; ByungJae SO ; Eun Jin CHOI
Korean Journal of Veterinary Research 2018;58(2):107-109
An 8-year-old female Eurasian otter (Lutra lutra) reared in a wetland center, died 2 h after sudden onset of astasia and dyspnea despite medical treatment. Gross examination of internal organs revealed 10 adult filarioid nematodes in the right ventricle of the heart and three between the left and right cerebral hemispheres. All nematodes were identified as Dirofilaria immitis by direct microscopy and polymerase chain reaction assay. Histopathological observation revealed multifocal hemorrhage in the cerebral subarachnoid space and focal necrosis with hemorrhagein the cerebellar parenchyma. Although rare, veterinarians should consider cerebral dirofilariasis as a differential diagnosis in unexplained neurological cases.
Adult
;
Animals
;
Brain
;
Cerebrum
;
Child
;
Diagnosis, Differential
;
Dirofilaria immitis
;
Dirofilaria
;
Dirofilariasis
;
Dyspnea
;
Female
;
Heart
;
Heart Ventricles
;
Hemorrhage
;
Humans
;
Korea
;
Microscopy
;
Necrosis
;
Otters
;
Polymerase Chain Reaction
;
Subarachnoid Space
;
Veterinarians
;
Wetlands
4.Disagreement between direct and indirect blood pressure measurements obtained from minipigs
Won Jae LEE ; Lisa Soyeon PARK
Korean Journal of Veterinary Research 2018;58(3):131-136
Blood pressure (BP) measurement plays a pivotal role in veterinary medicine for diagnosing cardiovascular disorders and monitoring anesthesia of animals. Although indirect BP measurement has been widely applied to monitor BP because of its convenience and non-invasiveness, it is still unclear whether indirect BP measurement is compatible with direct BP measurement in minipigs. In addition, the effect of animal posture during BP measurement is not well understood in minipigs despite its importance to cardiovascular performance. Therefore, both systolic and diastolic arterial BPs in minipigs were measured via femoral artery catheterization for direct BP measurement and using a compressive cuff as an indirect BP measurement under the dorsal or right lateral recumbent postures. Numerical values were processed by the Bland-Altman method to calculate the bias ± SD and the limits of agreement (LOA). In accordance with the American College of Veterinary Internal Medicine guidelines, the results between direct and indirect BP measurements were determined as apparent disagreements in both systolic and diastolic arterial BPs under all postures because of large bias ± SD and wide LOA. The results of the present will help prevent misinterpretation of the anesthetized patient's condition during monitoring of BP by indirect measurement.
Anesthesia
;
Animals
;
Bias (Epidemiology)
;
Blood Pressure
;
Catheterization
;
Catheters
;
Diagnosis
;
Femoral Artery
;
Internal Medicine
;
Loa
;
Methods
;
Posture
;
Swine, Miniature
;
Veterinary Medicine
5.Optimal Phase of Dynamic Computed Tomography for Reliable Size Measurement of Metastatic Neuroendocrine Tumors of the Liver: Comparison between Pre- and Post-Contrast Phases.
Jimi HUH ; Jisuk PARK ; Kyung Won KIM ; Hyoung Jung KIM ; Jong Seok LEE ; Jong Hwa LEE ; Yoong Ki JEONG ; Atul B SHINAGARE ; Nikhil H RAMAIYA
Korean Journal of Radiology 2018;19(6):1066-1076
OBJECTIVE: The reliability of size measurements of liver metastases from neuroendocrine tumors (NETs) on contrast-enhanced computed tomography (CT) phases made by different readers may be hampered due to transient, variable rim enhancement in arterial phase (AP) or portal venous phase (PVP) images. We aimed to assess the reliability of tumor size measurements in pre- and post-contrast scans. MATERIALS AND METHODS: The study coordinator selected target lesions according to Response Evaluation Criteria in Solid Tumors 1.1 guidelines in 44 consecutive patients with pathologically confirmed NET liver metastases. Two blinded readers measured the longest diameters of target lesions on pre-contrast, AP, and PVP images twice with a 4-week interval. Inter- and intra-observer agreements were evaluated using Bland-Altman plots and 95% limit of agreement (LOA) calculations. RESULTS: Of the 79 target lesions (approximate mean size of 3 cm), 45 showed rim enhancement. Inter-observer agreement assessed based on LOA was highest in pre-contrast CT images (−6.1–5.7 mm), followed by PVP (−7.9–7.1 mm) and AP (−8.5–7.4 mm) images. Intra-observer agreement showed the same trend: −2.8–2.9 mm and −2.9–2.9 mm for readers 1 and 2, respectively, on pre-contrast CT, −2.8–2.9 mm and −3.0–3.2 mm, respectively, on PVP, and −3.2–4.2 mm and −3.4–3.2 mm, respectively, on AP images. Mean tumor diameters differed significantly among the phases in the following increasing order: pre-contrast CT, PVP, and AP images. CONCLUSION: There was better inter- and intra-observer agreement in size measurements of NET liver metastases on precontrast scans than on AP and PVP scans. Pre-contrast CT may be the optimal for measuring NET liver metastases if its accuracy is proven.
Humans
;
Liver*
;
Loa
;
Neoplasm Metastasis
;
Neuroendocrine Tumors*
;
Response Evaluation Criteria in Solid Tumors
6.Seroprevalence of Dirofilaria immitis in Cats from Liaoning Province, Northeastern China.
Honglie HOU ; Lili CAO ; Wenzhi REN ; Dansheng WANG ; He DING ; Juan YOU ; Xinhua YAO ; Hang DONG ; Yanbing GUO ; Shuxian YUAN ; Xichen ZHANG ; Pengtao GONG
The Korean Journal of Parasitology 2017;55(6):673-677
The present study was performed to investigate the seroprevalence and risk factors for Dirofilaria immitis infection in cats from Liaoning province, northeastern China. From October 2014 to September 2016, sera of 651 cats, including 364 domestic cats and 287 feral cats (332 females and 319 males) were assessed. They were tested for the presence of D. immitis antigen using SNAP Heartworm RT test kit. In this population, the average prevalence was 4.5%. Age and rearing conditions (feral or domestic) were found to be associated with the prevalence of D. immitis. The prevalence was significantly higher in feral cats compared with domestic cats (8.4% vs 1.4%, P < 0.01). There was no significant difference between males and females (4.7% vs 4.2%, P>0.05), but older cats (≥3 years old) showed a statistically higher prevalence compared with younger cats ( < 3 years old) in feral populations (16.8 vs 2.4%, P < 0.01), while the difference between the age groups was not statistically significant in domestic cats (2.4% vs 0.51%, P>0.05), all these results suggest that outdoor exposure time may be one of the most important factors for D. immitis prevalence in cats. Results reveal that D. immitis are prevalence in domestic and feral cats in northeastern China, which indicates that appropriate preventive measures should be taken to decrease the incidence of feline heartworm disease in Liaoning province, northeastern China.
Animals
;
Cats*
;
China*
;
Dirofilaria immitis*
;
Dirofilaria*
;
Dirofilariasis
;
Female
;
Humans
;
Incidence
;
Male
;
Prevalence
;
Risk Factors
;
Seroepidemiologic Studies*
7.Reliability and Validity of a New Method for Isometric Back Extensor Strength Evaluation Using A Hand-Held Dynamometer.
Hee Won PARK ; Sora BAEK ; Hong Young KIM ; Jung Gyoo PARK ; Eun Kyoung KANG
Annals of Rehabilitation Medicine 2017;41(5):793-800
OBJECTIVE: To investigate the reliability and validity of a new method for isometric back extensor strength measurement using a portable dynamometer. METHODS: A chair equipped with a small portable dynamometer was designed (Power Track II Commander Muscle Tester). A total of 15 men (mean age, 34.8±7.5 years) and 15 women (mean age, 33.1±5.5 years) with no current back problems or previous history of back surgery were recruited. Subjects were asked to push the back of the chair while seated, and their isometric back extensor strength was measured by the portable dynamometer. Test-retest reliability was assessed with intraclass correlation coefficient (ICC). For the validity assessment, isometric back extensor strength of all subjects was measured by a widely used physical performance evaluation instrument, BTE PrimusRS system. The limit of agreement (LoA) from the Bland-Altman plot was evaluated between two methods. RESULTS: The test-retest reliability was excellent (ICC=0.82; 95% confidence interval, 0.65–0.91). The Bland-Altman plots demonstrated acceptable agreement between the two methods: the lower 95% LoA was −63.1 N and the upper 95% LoA was 61.1 N. CONCLUSION: This study shows that isometric back extensor strength measurement using a portable dynamometer has good reliability and validity.
Back Muscles
;
Female
;
Humans
;
Isometric Contraction
;
Loa
;
Male
;
Methods*
;
Muscle Strength Dynamometer
;
Reproducibility of Results*
8.Follow-up Study of Patients Previously Diagnosed with Lymphatic Filariasis in Korea.
Hyeng Il CHEUN ; Hee Eun SHIN ; Da Won MA ; Sung Hee HONG ; Tae Yun KIM ; Sang Eun LEE ; JungWon JU ; Yun Kyu PARK ; Tong Soo KIM ; Shin Hyeong CHO
Osong Public Health and Research Perspectives 2017;8(6):421-424
OBJECTIVES: Korea was an endemic area for lymphatic filariasis (LF), caused by the nematode parasite Brugia malayi, until the 1970s. The World Health Organization recognized Korea as LF-free in June 2008. However, it is necessary to confirm that patients that have had LF in the past still test negative, to prevent the re-emergence of LF in Korea. METHODS: We followed up a total of 83 patients who had been diagnosed with LF between 2002 and 2010 in endemic LF areas. RESULTS: Fifty-two of the 83 subjects were negative for LF, whereas 31 subjects had re-located to a different city or province, were dead, or were unaccounted for. Most subjects with negative test results still exhibited edema in the legs or the arms, and some complained of redness and swelling in the legs or ankle joints. However, we found that these symptoms were due to diseases other than LF. CONCLUSION: In this follow-up study, we did not find any evidence indicating the potential re-emergence of LF in Korea.
Ankle Joint
;
Arm
;
Brugia malayi
;
Edema
;
Elephantiasis, Filarial*
;
Follow-Up Studies*
;
Humans
;
Korea*
;
Leg
;
Parasites
;
World Health Organization
9.Measurement of Corneal Power and Astigmatism Using Placido-based Videokeratography and Comparison with Other Keratometers.
Yung Hui KIM ; Ying LI ; Hyo Seok LEE ; Kyung Chul YOON
Journal of the Korean Ophthalmological Society 2016;57(12):1874-1881
PURPOSE: In the present study, the repeatability and reproducibility of the corneal power and astigmatism measurements using placido-based video keratography were evaluated and the agreement with other keratometers were compared. METHODS: This prospective study included 45 patients (45 eyes) scheduled to undergo cataract surgery between November 2015 and January 2016. Three sets of corneal power and astigmatism were measured using placido-based video keratometer (Keratograph® 5M), automatic keratometer (KR-8900®), manual keratometer (B×L manual keratometer®), Placido-scanning-slit keratometer (ORBscan II®), Scheimpflug keratometer (Pentacam®), and low coherence interferometry (Lenstar LS900®). Reliability of each device was analyzed using the coefficient of variation, standard deviation and intraclass correlation coefficient. Repeated measures analysis of variance was used to analyze the interdevice comparison of mean absolute difference. The agreement between the devices was evaluated with 95% limits of agreement (LoA) and Bland-Altman plots. RESULTS: The mean corneal power, astigmatism and power vector analysis (J₀, J₄₅) were not significantly different among devices (p > 0.05). In the Bland-Altman plot analysis, the 95% LoA of corneal power, J₀, and J45 when comparing Keratograph® 5M with others ranged from -0.78 to 0.55 D, from -0.42 to 0.45 D, and from -0.39 to 0.47 D, respectively. CONCLUSIONS: Keratograph® 5M showed good repeatability and reproducibility of corneal power and astigmatism measurements and was interchangeable with other keratometers.
Astigmatism*
;
Cataract
;
Corneal Topography*
;
Humans
;
Interferometry
;
Loa
;
Prospective Studies
10.Comparison of Anterior Segment Measurements between Dual and Single Scheimpflug Camera.
Youngju AN ; Hyojin KIM ; Choun Ki JOO
Journal of the Korean Ophthalmological Society 2016;57(7):1056-1062
PURPOSE: To assess the degree of agreement of two rotating Scheimpflug cameras, Galilei G6 and Pentacam HR, in measuring corneal refractive power (K), anterior chamber depth (ACD), and central corneal thickness (CCT). METHODS: Measurement agreement was assessed in 40 eyes of 40 outpatients at our hospital. Measurements of anterior and posterior corneal refractive power (K), ACD, and CCT were compared between the Galilei G6 and Pentacam HR. RESULTS: For Galilei G6 (4 mm), Pentacam HR (3 mm) and Pentacam HR (4 mm), the anterior corneal refractive powers (K) were 44.35 ± 1.38 D, 44.09 ± 1.32 D, and 44.12 ± 1.35 D, respectively, and the posterior corneal refractive powers (K) were 6.39 ± 0.23 D, 6.45 ± 0.23 D, 6.45 ± 0.22 D. The differences in the results were statistically significant. The average ACD measurements using Galilei G6 and Pentacam HR were 3.26 ± 0.42 mm and 3.17 ± 0.42 mm, respectively, and the average CCT measurements were 556.65 ± 30.12 µm and 553.78 ± 29.42 µm. The differences in the measurements were statistically significant. In addition, ACD 95% limits of agreement (LoA) between Galilei G6 and Pentacam HR were in the range of -0.14~0.32 mm, and CCT 95% LoA were in the range of -12.54~18.29 µm. CONCLUSIONS: There were significant differences in measurements of anterior and posterior corneal refractive power (K), ACD, and CCT between the two cameras. Agreement analysis suggests that Galilei G6 and Pentacam HR should not be used interchangeably.
Anterior Chamber
;
Humans
;
Loa
;
Outpatients

Result Analysis
Print
Save
E-mail