1.Classification of Fetal Heart Rate Based on Poincare Plot and LSTM.
Mingzhu YE ; Lihuan SHAO ; Yanjun DENG
Chinese Journal of Medical Instrumentation 2021;45(3):250-255
Fetal heart rate plays an essential role in maternal and fetal monitoring and fetal health detection. In this study, a method based on Poincare Plot and LSTM is proposed to realize the high performance classification of abnormal fetal heart rate. Firstly, the original fetal heart rate signal of CTU-UHB database is preprocessed via interpolation, then the sequential fetal heart rate signal is converted into Poincare Plot to obtain nonlinear characteristics of the signals, and then SquenzeNet is used to extract the features of Poincare Plot. Finally, the features extracted by SqueezeNet are classified by LSTM. And the accuracy, the true positive rate and the false positive rate are 98.00%, 100.00%, 92.30% respectively on 2 000 test set data. Compared with the traditional fetal heart rate classification method, all respects are improved. The method proposed in this study has good performance in CTU-UHB fetal monitoring database and has certain practical value in the clinical diagnosis of auxiliary fetal heart rate detection.
Databases, Factual
;
Female
;
Fetal Monitoring
;
Fetus
;
Heart Rate, Fetal
;
Humans
;
Pregnancy
2.A fetal electrocardiogram signal extraction method based on long short term memory network optimized by genetic algorithm.
Long QIAN ; Wenbo WANG ; Guici CHEN ; Min YU
Journal of Biomedical Engineering 2021;38(2):257-267
Fetal electrocardiogram signal extraction is of great significance for perinatal fetal monitoring. In order to improve the prediction accuracy of fetal electrocardiogram signal, this paper proposes a fetal electrocardiogram signal extraction method (GA-LSTM) based on genetic algorithm (GA) optimization with long and short term memory (LSTM) network. Firstly, according to the characteristics of the mixed electrocardiogram signal of the maternal abdominal wall, the global search ability of the GA is used to optimize the number of hidden layer neurons, learning rate and training times of the LSTM network, and the optimal combination of parameters is calculated to make the network topology and the mother body match the characteristics of the mixed signals of the abdominal wall. Then, the LSTM network model is constructed using the optimal network parameters obtained by the GA, and the nonlinear transformation of the maternal chest electrocardiogram signals to the abdominal wall is estimated by the GA-LSTM network. Finally, using the non-linear transformation obtained from the maternal chest electrocardiogram signal and the GA-LSTM network model, the maternal electrocardiogram signal contained in the abdominal wall signal is estimated, and the estimated maternal electrocardiogram signal is subtracted from the mixed abdominal wall signal to obtain a pure fetal electrocardiogram signal. This article uses clinical electrocardiogram signals from two databases for experimental analysis. The final results show that compared with the traditional normalized minimum mean square error (NLMS), genetic algorithm-support vector machine method (GA-SVM) and LSTM network methods, the method proposed in this paper can extract a clearer fetal electrocardiogram signal, and its accuracy, sensitivity, accuracy and overall probability have been better improved. Therefore, the method could extract relatively pure fetal electrocardiogram signals, which has certain application value for perinatal fetal health monitoring.
Algorithms
;
Electrocardiography
;
Female
;
Fetal Monitoring
;
Humans
;
Memory, Short-Term
;
Pregnancy
;
Support Vector Machine
3.Remote monitoring of neonatal jaundice in newborns with ABO hemolytic disease.
Chuncai XU ; Yingying BAO ; Jiajun ZHU ; Yanping TENG ; Yuanyuan HE ; Ke CHENG ; Fengjuan JI ; Mingyuan WU
Journal of Zhejiang University. Medical sciences 2020;49(5):651-655
OBJECTIVE:
To explore the feasibility of remote monitoring of neonatal jaundice in newborns with ABO hemolytic disease.
METHODS:
Forty six neonates of gestational age >35 weeks with ABO hemolytic disease admitted to Women's Hospital, Zhejiang University School of Medicine from January 20th, 2020 to February 29th, 2020 were enrolled in the study (study group). The newborns were followed up at home after discharge, the transcutaneous bilirubin (TCB) levels were measured by parents using the provided device and the results were sent to the doctor by smart phone using the installed APP. Fifty six newborns with ABO hemolytic disease admitted in 2018 who received conventional outpatient follow-up after discharge served as the control group. The demographic characteristics, total serum bilirubin (TSB) level during hospitalization, number of outpatient visit and rate of re-admission due to rebound hyperbilirubinemia were compared between the two groups.
RESULTS:
There were no significant differences between the two groups in gestational age, birth weight, delivery mode, gender, length of the first hospitalization, TSB level before phototherapy and before discharge, and the managements during the first hospitalization (all
CONCLUSIONS
The remote follow-up for neonatal jaundice at home can effectively reduce the number of outpatient visits without increasing the risk of readmission and severe neonatal hyperbilirubinemia for newborns with ABO hemolytic disease.
Bilirubin
;
Erythroblastosis, Fetal/diagnosis*
;
Female
;
Humans
;
Hyperbilirubinemia, Neonatal/diagnosis*
;
Infant, Newborn
;
Jaundice, Neonatal/diagnosis*
;
Monitoring, Physiologic/methods*
;
Phototherapy
4.Anti-disturbance Fetal Heart Rate System Based on Combined Maternal-fetal Monitoring.
Tianyi XU ; Ping CAI ; Xiaohua LIU ; Yixin MA
Chinese Journal of Medical Instrumentation 2019;43(3):162-164
The existing fetal monitor is prone to false detection in the case of high maternal interference in the second stage of labor. With this background, the article designs and implements a combined maternal-fetal fetal heart monitoring system. The system obtains the Doppler signal of the abdominal fetal heart and the blood oxygen signal of the mother's finger, and estimates the maternal interference degree in the fetal heart rate Doppler signal according to the maximum correlation value between the maternal finger blood oxygen signal and the abdominal fetal heart Doppler signal, and switches the fetal heart rate extraction algorithm between the autocorrelation method suitable for lower interference and improved template method suitable for higher interference according to the maternal interference degree. The accuracy of our method is 9.2% which is higher than that of the improved template matching method and 6.1% higher than that of the autocorrelation method.
Algorithms
;
Electrocardiography
;
Female
;
Fetal Monitoring
;
instrumentation
;
Fetus
;
Heart Rate
;
Heart Rate, Fetal
;
Humans
;
Pregnancy
;
Signal Processing, Computer-Assisted
5.Optimal template selecting combined with non-liner template matching for Doppler fetal heart rate extraction.
Tianyi XU ; Ping CAI ; Xiaohua LIU ; Yixin MA
Journal of Biomedical Engineering 2019;36(4):557-564
The ultrasound Doppler fetal heart rate measurement is the gold standard of fetal heart rate counting. However, the existing fetal heart rate extraction algorithms are not designed specifically to suppress the high maternal interference during the second stage of labor, and false detection occurrences are common during labor. With this background, a method combining time-frequency frame template library optimal selecting and non-linear template matching is proposed. The method contributes a template library, and the optimal template can be selected to match the signal frame. After the short-time Fourier transform of the signal, the difference between the signal and the template is optimized by leaky rectified linear unit (LReLU) function frame by frame. The heart rate was calculated from the peak of the matching curve and the heart rate was calculated. By comparing the proposed method with the autocorrelation method, the results show that the detection accuracy of the proposed method is improved by 20% on average, and the non-linear template matching of 23% samples is at least 50% higher than the autocorrelation method. This paper designs the algorithm by analyzing the characteristics of the interference and signal mixing. We hope that this paper will provide a new idea for fetal heart rate extraction which not only focuses on the original signal.
Algorithms
;
Female
;
Fetal Monitoring
;
Fourier Analysis
;
Heart Rate, Fetal
;
Humans
;
Pregnancy
;
Signal Processing, Computer-Assisted
;
Ultrasonography, Doppler
6.Fetal autonomic malfunction as a marker of fetal distress in growth-restricted fetuses: three case reports
Igor Victorovich LAKHNO ; Schmidt ALEXANDER
Obstetrics & Gynecology Science 2019;62(6):469-473
Fetal growth restriction (FGR) is characterized by fetal compromise and delayed neurological maturation. We report 3 cases of early FGR in the 26th week of gestation, based on hemodynamic Doppler monitoring, conventional cardiotocography, and non-invasive fetal electrocardiography (NI-FECG). Fetal heart rate variability (HRV), beat-to-beat variations, and fetal autonomic brain age scores (fABASs) were normal despite the absence of umbilical diastolic flow in the first case and the pregnancy continued to 30 weeks. NI-FECG helped achieve better fetal maturity. Fetal HRV and fABASs were low in the second and third cases. Fetal demise occurred soon in both cases. We conclude that NI-FECG could be a prospective method for the detection of fetal distress in early FGR.
Brain
;
Cardiotocography
;
Electrocardiography
;
Embryonic and Fetal Development
;
Female
;
Fetal Death
;
Fetal Development
;
Fetal Distress
;
Fetus
;
Heart Rate, Fetal
;
Hemodynamics
;
Methods
;
Pregnancy
;
Prospective Studies
7.Reviving external cephalic version: a review of its efficacy, safety, and technical aspects
Obstetrics & Gynecology Science 2019;62(6):371-381
Currently, the rate of cesarean sections being performed in Korea is approximately 40%, with Korea ranking 4th among the Organization for Economic Co-operation and Development countries with respect to cesarean deliveries. Breech presentation at term is an important indication for cesarean section among other factors, including medicolegal concerns and pregnancies in women of advanced maternal age. Term breech presentation is associated with a higher fetal mortality rate than that associated with a cephalic presentation. Therefore, in Korea, most of these women deliver by cesarean section to avoid the complications of vaginal breech delivery. However, cesarean section is itself associated with considerable obstetric morbidity and sometimes, mortality. External cephalic version (ECV) is a useful method to reduce the cesarean section rate in women with breech presentation and therefore to reduce the incidence of breech presentation at delivery. Studies have shown that routine use of ECV reduces the cesarean section rate by approximately two-thirds in term pregnancies with breech presentation. ECV is accepted as a safe, efficacious, and cost-effective method and is recommended by both the American College of Obstetricians and Gynecologists and the Royal College of Obstetricians and Gynecologists in all pregnancies with term breech presentation, if not contraindicated. In Korea, although most clinicians are aware of the option of ECV, their relative lack of experience in performing the procedure and fear of complications render them hesitant to perform ECV. This review is aimed at guiding obstetricians by describing the efficacy, safety concerns, and technical aspects of this procedure.
Breech Presentation
;
Cardiotocography
;
Cesarean Section
;
Female
;
Fetal Mortality
;
Humans
;
Incidence
;
Korea
;
Maternal Age
;
Methods
;
Mortality
;
Pregnancy
;
Version, Fetal
8.Fetal Doppler to predict cesarean delivery for non-reassuring fetal status in the severe small-for-gestational-age fetuses of late preterm and term.
Ji Hye JO ; Yong Hee CHOI ; Jeong Ha WIE ; Hyun Sun KO ; In Yang PARK ; Jong Chul SHIN
Obstetrics & Gynecology Science 2018;61(2):202-208
OBJECTIVE: To evaluate the significance of fetal Doppler parameters in predicting adverse neonatal outcomes and the risk of cesarean delivery due to non-reassuring fetal status, in severe small for gestational age (SGA) fetuses of late preterm and term gestation. METHODS: Fetal brain and umbilical artery (UmA) Doppler parameters of cerebroplacental ratio (CPR) and UmA pulsatility index (PI) were evaluated in a cohort of 184 SGA fetuses between 34 and 41 weeks gestational age, who were less than the 5th percentile. The risks of neonatal morbidities and cesarean delivery due to non-reassuring fetal status were analyzed. RESULTS: Univariate analysis revealed that abnormal CPR was significantly associated with cesarean delivery due to non-reassuring fetal status (P=0.018), but not with neonatal morbidities. However, abnormal CPR did not increase the risk of cesarean delivery due to non-reassuring fetal status in multivariate logistic regression analysis. Abnormal CPR with abnormal PI of UmA was associated with low Apgar score at 1 minute (P=0.048), mechanical ventilation (P=0.013) and cesarean delivery due to non-reassuring fetal status (P < 0.001), in univariate analysis. It increased risk of cesarean delivery for non-reassuring fetal status (adjusted odds ratio, 7.0; 95% confidence interval, 1.2–41.3; P=0.033), but did not increase risk of low Apgar score or mechanical ventilation in multivariate logistic regression analysis. CONCLUSION: Abnormal CPR with abnormal PI of UmA increases the risk of cesarean delivery for non-reassuring fetal status, in severe SGA fetuses of late preterm and term. Monitoring of CPR and PI of UmA can help guide management including maternal hospitalization and fetal monitoring.
Apgar Score
;
Brain
;
Cardiopulmonary Resuscitation
;
Cesarean Section
;
Cohort Studies
;
Female
;
Fetal Monitoring
;
Fetus*
;
Gestational Age
;
Hospitalization
;
Humans
;
Infant, Newborn
;
Infant, Small for Gestational Age
;
Logistic Models
;
Odds Ratio
;
Pregnancy
;
Respiration, Artificial
;
Umbilical Arteries
9.Effect of Structured Bed Exercise on Uterine Contractions, Fetal Heart Rate Patterns, and Maternal Psychophysical Symptoms of Hospitalized High-Risk Pregnant Women: A Randomized Control Trial.
Young Jeoum KIM ; Young Joo PARK
Asian Nursing Research 2018;12(1):1-8
PURPOSE: This study examined the effect on uterine contraction frequency (UCF), blood pressure (BP), heart rate (HR), fetal heart rate (FHR) patterns and psychophysical symptoms (physical discomfort, anxiety, and depression) of structured bed exercise (SBE) in hospitalized high-risk pregnant women prescribed bed rest. METHODS: Forty-five hospitalized high risk pregnant women at >24 weeks of pregnancy prescribed bed rest were randomly assigned to the experimental or control group. From January to May 2014, data were collected using electronic fetal monitoring and patient monitoring of UCF, BP, HR and FHR patterns, and psychophysical symptoms were measured using the antenatal physical discomfort scale, state-trait anxiety scale, and Edinburgh postnatal depression scale. RESULTS: UCF, BP, HR, and FHR patterns (rate, variability, acceleration, and deceleration) did not differ significantly between the experimental and control groups. The experimental group showed a significant increase in baseline FHR after SBE within the normal range, and after SBE, it reduced to the FHR before SBE. The variability, acceleration and deceleration of FHR before and after SBE did not differ significantly between two groups. Moreover, there was no statistically significant difference before and after SBE in the experimental group. Also, the experimental group showed statistically significant decreases in physical discomfort score. However, there were no significant differences in depression and anxiety score between two groups. CONCLUSIONS: SBE in hospitalized high-risk pregnant women under bed rest did not increase the risk to the fetus, and relieved physical discomfort and anxiety. Therefore, SBE should be considered as a nursing intervention in hospitalized high-risk pregnant women.
Acceleration
;
Anxiety
;
Bed Rest
;
Blood Pressure
;
Cardiotocography
;
Deceleration
;
Depression
;
Depression, Postpartum
;
Female
;
Fetal Heart*
;
Fetus
;
Heart Rate
;
Heart Rate, Fetal*
;
Humans
;
Monitoring, Physiologic
;
Nursing
;
Pregnancy
;
Pregnancy, High-Risk
;
Pregnant Women*
;
Reference Values
;
Uterine Contraction*
10.Effect of Music Intervention on Maternal Anxiety and Fetal Heart Rate Pattern During Non-Stress Test.
Myung Ok OH ; Young Jeoum KIM ; Cho Hee BAEK ; Ju Hee KIM ; No Mi PARK ; Mi Jeong YU ; Han Sol SONG
Journal of Korean Academy of Nursing 2016;46(3):315-326
PURPOSE: The purpose of this cross-over experimental study was to examine effects of music intervention on maternal anxiety, fetal heart rate pattern and testing time during non-stress tests (NST) for antenatal fetal assessment. METHODS: Sixty pregnant women within 28 to 40 gestational weeks were randomly assigned to either the experimental group (n=30) or control group (n=30). Music intervention was provided to pregnant women in the experimental group during NST. Degree of maternal anxiety and fetal heart rate pattern were our primary outcomes. State-trait anxiety inventory, blood pressure, pulse rate, and changes in peripheral skin temperature were assessed to determine the degree of maternal anxiety. Baseline fetal heart rate, frequency of acceleration in fetal heart rate, fetal movement test and testing time for reactive NST were assessed to measure the fetal heart rate pattern. RESULTS: The experimental group showed significantly lower scores in state anxiety than the control group. There were no significant differences in systolic blood pressure and pulse rate between the two groups. Baseline fetal heart rate was significantly lower in the experimental group than in the control group. Frequency of acceleration in fetal heart rate was significantly increased in the experimental group compared to the control group. There were no significant differences in fetal movement and testing time for reactive NST between the two groups. CONCLUSION: Present results suggest that music intervention could be an effective nursing intervention for alel viating anxiety during non-stress test.
Acceleration
;
Anxiety*
;
Blood Pressure
;
Cardiotocography
;
Female
;
Fetal Heart*
;
Fetal Movement
;
Heart Rate
;
Heart Rate, Fetal*
;
Humans
;
Music*
;
Nursing
;
Pregnancy
;
Pregnant Women
;
Skin Temperature

Result Analysis
Print
Save
E-mail