1.Discussion on the effects of Qizhi Tongluo Prescription on renal damage in rats with membranous nephropathy based on the Shh/Gli1 signaling pathway
Yicong ZHAO ; Yuhan NIU ; Yuan LI ; Xiaowei JU ; Qian LIU ; Guodong YUAN ; Qian ZHANG ; Suzhi CHEN ; Chuchu CHEN ; Jinchuan TAN ; Fengwen YANG
International Journal of Traditional Chinese Medicine 2025;47(8):1095-1102
Objective:To observe the effects of Qizhi Tongluo Prescription on renal interstitial fibrosis in rats with membranous nephropathy based on the Shh/Gli1 signaling pathway; To explore its intervention mechanism.Methods:Totally 60 male SD rats were divided into blank group ( n=10) and model group ( n=50) using random number table method. The model of membranous nephropathy was established according to the modified Border method. The successfully modeling rats were divided into model group, benazepril group and Qizhi Tongluo Prescription low-, medium- and high-dosage groups using random number table method. Benazepril group was gavaged with benazepril hydrochloride 10 mg/kg, Qizhi Tongluo Prescription low-, medium- and high-dosage groups were gavaged with Qizhi Tongluo Prescription solution 1.22 g/kg, 2.43 g/kg and 4.86 g/kg, and blank group and model group were gavaged with equal volume of normal saline, once a day, for 4 weeks. The 24-hour urine was collected to detect the 24-hour urinary protein quantification, and the blood was taken from the abdominal aorta to detect the levels of total cholesterol (TC), triglyceride(TG), and serum albumin(ALB); the pathological changes of rat kidney were observed by light microscope and transmission electron microscope; the protein expressions of sonic hedgehog factor (Shh), zinc finger protein 1 (Gli1) and α-smooth muscle actin (SMA) in renal tissues were detected by immunohistochemistry; the protein expressions of Shh, Gli1, α-SMA, TGF-β1, Collagen Ⅳ and plasminogen activator inhibitor-1 (PAl-1) in renal tissues were detected by Western blot. Results:Compared with the model group, the quantitative level of 24-hour urinary protein of rats in each administration group decreased ( P<0.05), serum TC and TG levels increased ( P<0.05), ALB level decreased ( P<0.05), the positive expressions of Shh, Gli1, α-SMA protein in renal tissue decreased ( P<0.05), and the protein expressions of Shh, Gli1, α-SMA, Collagen Ⅳ, TGF-β1, PAI-1 in renal tissue decreased ( P<0.05). Conclusion:Qizhi Tongluo Prescription can improve renal interstitial fibrosis in membranous nephropathy rats, possibly by inhibiting the Shh/Gli1 signaling pathway to delay renal interstitial fibrosis.
2.Report of Successful Percutaneous Closure of Patent Foramen Ovale Using Fully Biodegradable Occluder Solely under Echocardiography Guidance
Yiming YAN ; Ziping LI ; Fengwen ZHANG ; Hongmei SU ; Ying'ao ZHAO ; Jing DONG ; Guangzhi ZHAO ; Wenbin OUYANG ; Xiangbin PAN
Chinese Circulation Journal 2025;40(10):1033-1035
This article reports the first case of percutaneous closure of patent foramen ovale(PFO)using a biodegradable occluder under echocardiography guidance.The patient is a 43-year-old female diagnosed with PFO-related stroke.The procedure was successfully completed under echocardiography guidance without complications.During the 48-month follow-up period,the patient experienced no recurrent strokes,and the occluder was fully degraded.
3.Feasibility Exploration of Zero-ray Radiofrequency Catheter Ablation of Atrial Fibrillation Guided by Transthoracic Echocardiography Combined With Three-dimensional Mapping System
Tianjie FENG ; Guangzhi ZHAO ; Jing DONG ; Cheng WANG ; Fengwen ZHANG ; Shouzheng WANG ; Jun LIU ; Guodong NIU ; Min TANG ; Fujian DUAN ; Xiangbin PAN
Chinese Circulation Journal 2025;40(4):374-379
Objectives:To explore the feasibility of zero-ray radiofrequency catheter ablation for paroxymal atrial fibrillation under the guidance of transthoracic echocardiography combined with three-dimensional mapping system.Methods:This is a single-center prospective observational study.A total of 12 patients with paroxysmal atrial fibrillation who underwent radiofrequency catheter ablation in Fuwai Hospital,Chinese Academy of Medical Sciences from June 1,2024 to September 30,2024 were included.All patients underwent successful percutaneous puncture,atrial septal puncture under the guidance of transthoracic echocardiography,and all patients underwent left atrial modeling and discharge ablation under the guidance of transthoracic echocardiography combined with three-dimensional mapping system.The disappearance of pulmonary vein potential was confirmed after the ablation operation and as the ablation endpoint and successful ablation marker.The operation results and 1-month and 3-month follow-up results of the patients were observed.Results:There were 12 patients with paroxysmal atrial fibrillation,9 males and 3 females,aged(56.8±11.2)years,with a history of paroxysmal atrial fibrillation(4.2±2.3)years.The mean left atrial diameter was(36.5±2.5)mm,the left ventricular end-diastolic diameter was(47.8±4.1)mm,and the left ventricular ejection fraction was 55%-65%.The mean overall operation time was(102.25±14.51)min,the ultrasound operation time was(29.58±6.23)min,and the catheter operation time was(33.08±4.10)min.All patients completed circumferential pulmonary vein isolation without intraoperative complications.The hospitalization time was 2-6 days.At the 1-month follow-up after ablation,all patients showed sinus rhythm on 24-hour ambulatory electrocardiogram,and 2 patients had occasional atrial premature contractions without recurrence of atrial fibrillation.At the 3-month follow-up,two patients had occasional premature atrial contractions,and no recurrence of atrial fibrillation was recorded on the electrocardiogram of all patients.Conclusions:It is feasible to complete radiofrequency catheter ablation of paroxysmal atrial fibrillation under the guidance of transthoracic echocardiography combined with three-dimensional mapping system.
4."Two-point and two-line method" in design of free perforator flap of medial sural artery: clinical application and clinical significance
Yan ZHANG ; Yucheng LIU ; Yang CAO ; Haibo WU ; Yongtao HUANG ; Chengpeng YANG ; Fengwen SUN ; Qinfeng GAO ; Jihui JU ; Guangzhe JIN
Chinese Journal of Microsurgery 2025;48(1):55-59
Objective:To study the feasibility of design and harvest of free medial sural artery perforator flap with the "two-point and two-line method".Methods:From September 2022 to June 2023, Suzhou Ruihua Orthopaedic Hospital implemented the "two-point and two-line method" to guide preoperative perforator positioning and flap design. Thirty medial sural artery perforator flaps were successfully harvested with the method, and 21 wounds of hand and 9 of foot and ankle were reconstructed with the flaps. The size of soft tissue defects were 2.5 cm×2.5 cm-7.0 cm×14.5 cm, and the flaps size were 3.0 cm×3.0 cm-7.5 cm×15.0 cm. All donor sites were directly closed or by skin grafting. All patients were entered in 6-15 months of postoperative outpatient follow-up, and the recovery of donor and recipient sites was assessed by the comprehensive evaluation scales. The sensory function of the flaps was evaluated using the sensory function evaluation standard of British Medical Research Council (BMRC).Results:All perforators were successfully located with 47 perforators in total, and all of them were musculocutaneous perforator. It was found that there was 1 perforator in 14 flaps, 2 perforators in 15 flaps and 3 perforators in 1 flap. All 30 flaps survived after surgery, beside 2 flaps that had arterial insufficiency but survived successfully after surgical exploration. All donor sites healed in one stage. Comprehensive evaluation scale of flap was employed to evaluate the flaps and the scores were 84 points to 96 points with an average score of 92.5 points. The excellent and good grades were achieved in 27 flaps and 3 flaps, respectively, with a combined excellent and good rate at 100%. Sensation of the flaps was evaluated by BMRC with 1 flap of S 1, 17 of S 2 and 12 of S 3. Conclusion:The "two-point and two-line method" has been used in design of the perforator flap of medial sural artery. This method is simple and accurate, and is feasible and ideal in design of flaps before surgery.
5.Feasibility Exploration of Zero-ray Radiofrequency Catheter Ablation of Atrial Fibrillation Guided by Transthoracic Echocardiography Combined With Three-dimensional Mapping System
Tianjie FENG ; Guangzhi ZHAO ; Jing DONG ; Cheng WANG ; Fengwen ZHANG ; Shouzheng WANG ; Jun LIU ; Guodong NIU ; Min TANG ; Fujian DUAN ; Xiangbin PAN
Chinese Circulation Journal 2025;40(4):374-379
Objectives:To explore the feasibility of zero-ray radiofrequency catheter ablation for paroxymal atrial fibrillation under the guidance of transthoracic echocardiography combined with three-dimensional mapping system.Methods:This is a single-center prospective observational study.A total of 12 patients with paroxysmal atrial fibrillation who underwent radiofrequency catheter ablation in Fuwai Hospital,Chinese Academy of Medical Sciences from June 1,2024 to September 30,2024 were included.All patients underwent successful percutaneous puncture,atrial septal puncture under the guidance of transthoracic echocardiography,and all patients underwent left atrial modeling and discharge ablation under the guidance of transthoracic echocardiography combined with three-dimensional mapping system.The disappearance of pulmonary vein potential was confirmed after the ablation operation and as the ablation endpoint and successful ablation marker.The operation results and 1-month and 3-month follow-up results of the patients were observed.Results:There were 12 patients with paroxysmal atrial fibrillation,9 males and 3 females,aged(56.8±11.2)years,with a history of paroxysmal atrial fibrillation(4.2±2.3)years.The mean left atrial diameter was(36.5±2.5)mm,the left ventricular end-diastolic diameter was(47.8±4.1)mm,and the left ventricular ejection fraction was 55%-65%.The mean overall operation time was(102.25±14.51)min,the ultrasound operation time was(29.58±6.23)min,and the catheter operation time was(33.08±4.10)min.All patients completed circumferential pulmonary vein isolation without intraoperative complications.The hospitalization time was 2-6 days.At the 1-month follow-up after ablation,all patients showed sinus rhythm on 24-hour ambulatory electrocardiogram,and 2 patients had occasional atrial premature contractions without recurrence of atrial fibrillation.At the 3-month follow-up,two patients had occasional premature atrial contractions,and no recurrence of atrial fibrillation was recorded on the electrocardiogram of all patients.Conclusions:It is feasible to complete radiofrequency catheter ablation of paroxysmal atrial fibrillation under the guidance of transthoracic echocardiography combined with three-dimensional mapping system.
6.Transcatheter Closure of Patent Ductus Arteriosus With a Fully Biodegradable Occluder Under the Sole Guidance of Transthoracic Echocardiography:a Case Report
Zizheng LIU ; Ying'ao ZHAO ; Jianing CUI ; Ning ZHOU ; Jing DONG ; Fengwen ZHANG ; Wenbin OUYANG ; Xiangbin PAN
Chinese Circulation Journal 2025;40(9):919-921
This article presents the first reported successful case of patent ductus arteriosus closure using a fully biodegradable occluder under the sole guidance of transthoracic echocardiography.Compared to traditional methods that require radiation and metal occluders,this technique,which combines echocardiography guidance with biodegradable devices,reduces iatrogenic injury and procedural risks,demonstrating favorable clinical outcomes.
7.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
8.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
9.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
10.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.

Result Analysis
Print
Save
E-mail