1.A preliminary study on the diagnostic value of ultrasonography in ischiofemoral impingement syndrome
Anqi ZHAO ; Suhong SHEN ; Jiahao FU ; Pai XU ; Zhuo FU ; Fengqin GENG ; Weihua QI ; Wenjing GUO
Chinese Journal of Sports Medicine 2025;44(5):375-380
Objective To explore the diagnostic value of ultrasonography in ischiofemoral impinge-ment syndrome(IFI).Methods Fifty-six patients who underwent hip MRI with confirmed IFI diagnosis and completed ultrasonography examinations were enrolled as the IFI group,including 44 females and 12 males.Twenty healthy volunteers were concurrently recruited as the control group,consisting of 10 females and 10 males.The control group underwent ultrasonography examinations of bilateral hip joints,whiletheischialfemoralspace(IFS)andquadratusfemoristhickness(QFT)of both groups were measured and recorded.Then measurements were compared within(by laterality and gender)and between the two groups using independent-samples t-tests.Moreover,receiver operating characteristic adults,males exhibited significantly higher IFS and QFT values than females(P<0.05).Within the IFI group,males with affected hips had significantly higher IFS than females(P<0.05),while no sig-nificant differences were observed in QFT between different genders(P>0.05).Moreover,affected hips in the IFI group showed significantly narrower IFS and thicker QFT compared to both contralateral hips and the control group(P<0.001).In addition,the diagnostic cut-off values of IFS and QFT for ultrasound diagnosis of IFI were 22.93 mm and 16.48 mm,respectively.At these thresholds,the ar-eas under the curve(AUC)were 0.997 and 0.977,with sensitivities of 97.8%and 91.8%,and speci-ficities of 98.4%and 97.8%,respectively.Conclusion Ultrasound can serve as a reliable diagnostic technique for IFI,where narrowing of the IFS and thickening of the QFT should raise suspicion of this condition.
2.A preliminary study on the diagnostic value of ultrasonography in ischiofemoral impingement syndrome
Anqi ZHAO ; Suhong SHEN ; Jiahao FU ; Pai XU ; Zhuo FU ; Fengqin GENG ; Weihua QI ; Wenjing GUO
Chinese Journal of Sports Medicine 2025;44(5):375-380
Objective To explore the diagnostic value of ultrasonography in ischiofemoral impinge-ment syndrome(IFI).Methods Fifty-six patients who underwent hip MRI with confirmed IFI diagnosis and completed ultrasonography examinations were enrolled as the IFI group,including 44 females and 12 males.Twenty healthy volunteers were concurrently recruited as the control group,consisting of 10 females and 10 males.The control group underwent ultrasonography examinations of bilateral hip joints,whiletheischialfemoralspace(IFS)andquadratusfemoristhickness(QFT)of both groups were measured and recorded.Then measurements were compared within(by laterality and gender)and between the two groups using independent-samples t-tests.Moreover,receiver operating characteristic adults,males exhibited significantly higher IFS and QFT values than females(P<0.05).Within the IFI group,males with affected hips had significantly higher IFS than females(P<0.05),while no sig-nificant differences were observed in QFT between different genders(P>0.05).Moreover,affected hips in the IFI group showed significantly narrower IFS and thicker QFT compared to both contralateral hips and the control group(P<0.001).In addition,the diagnostic cut-off values of IFS and QFT for ultrasound diagnosis of IFI were 22.93 mm and 16.48 mm,respectively.At these thresholds,the ar-eas under the curve(AUC)were 0.997 and 0.977,with sensitivities of 97.8%and 91.8%,and speci-ficities of 98.4%and 97.8%,respectively.Conclusion Ultrasound can serve as a reliable diagnostic technique for IFI,where narrowing of the IFS and thickening of the QFT should raise suspicion of this condition.
3.Investigation on Health Impact of Noise Created by House Decoration in Residential Quarters
Baoxiang WEI ; Xiaojuan GENG ; Fengqin TANG ;
Journal of Environment and Health 1992;0(02):-
Objective To provide scientific basis for the investigation, prevention,control and administration of house decoration noise Methods The equivalent noise levels (Leq),and the levels of noise dose (D L) in decorated houses,next door houses and outdoor environment were measured during different periods such as morning,noon,afternoon and evening in one day, as well as the health effects of noise in 3 residential quarters were investigated Results The Leqs levels during per 10 minutes were 79 6~104 7 dB(A) in decorated house The individuals exposure D L of decoration workers were 90%~180% The Leqs during per 20 minutes were 70 9~76 4 dB(A) in next door houses and 63 4~76 5dB(A) in the neiboaring residential building and office building 6~45 meters far from the decoration noise sources The annoyance rate among 149 residents was high and reached 89 8% The mental labourers revealed significantly higher annoyance rate compared with that of physical labourers Conclusion The health effects of decoration noise on occupational individuals and residents shouldnt be ignored

Result Analysis
Print
Save
E-mail