1.Evaluation of the public health governance capacity in Jiangsu Province
Peiyu FENG ; Anning MA ; Peiwu SHI ; Qunhong SHEN ; Chaoyang ZHANG ; Zheng CHEN ; Chuan PU ; Lingzhong XU ; Zhaohui GONG ; Tianqiang XU ; Panshi WANG ; Chao HAO ; Zhi HU ; Mo HAO ; Hua WANG ; Chengyue LI
Shanghai Journal of Preventive Medicine 2026;38(2):146-152
ObjectiveTo evaluate the public health governance capacity in Jiangsu Province and provide an optimized pathway for the construction of a “strong, rich, beautiful, and high-quality” new Jiangsu. MethodsA total of 806 policy documents, 658 public information reports, and 148 research literatures related to public health governance capacity in Jiangsu Province from January 1995 to December 2023 were collected. The status of current public health goverance was assessed based on the evaluation criteria suitable for public health systems, and the strengths and the weaknesses of the system were identified. ResultsThe public health governance capability of Jiangsu Province was scored at 738.3 points, ranking 3rd nationally. Maternal health care and emergency response capacities achieved leading positions nationwide, both ranking 2nd. Jiangsu had exhibited a standardized guidance in the strategic level, a well-established management mechanism, an extensive coverage in information collection, and a scientifically established health targets setting. However, bottlenecks remained, including an unclear division of responsibilities across organizational departments, an insufficient public-health workforce, the absence of a stable growth mechanism for government funding investment, and difficulties in promptly identifying public needs. ConclusionJiangsu’s public-health system demonstrates leading nationally, yet several components remain underdeveloped. Future efforts should consolidate advantages while addressing weaknesses, further diversify content and forms, establish a stable funding increase mechanism, and clarify departmental functions, thereby providing solid health support for realizing the developmental goals of a “strong, rich, beautiful and high-quality” new Jiangsu.
2.A Pneumatic Micro-valve with Sandwich Structure Based on Micro-electro-mechanical System
Shao-Jie MA ; Wen-Bo LI ; Yu-Chen ZHU ; Zhi-Rui LI ; Bin ZHAO ; Fei FENG
Chinese Journal of Analytical Chemistry 2025;53(5):758-764
In this study,an ON/OFF type micro-valve with a sandwich(glass-silicon-glass)structure was designed and fabricated based on the micro-electro-mechanical system(MEMS)technique.The deformable membrane of this micro-valve was prepared on the silicon on insulator(SOI)substrate and sealed using Si-Si bonding and anodic bonding methods.The micro-valve had high-temperature stability and was suitable for integration with other gas chromatography components.The deformable membrane with a thickness of 10 μm was processed on the top silicon of the SOI substrate.The flow control of the micro-valve could be achieved by changing the driving pressure applied to the deformable membrane to deform it.Compared with polymer membranes,the deformable membrane prepared on the top layer silicon of SOI had better temperature stability and could be released using the deep reactive ion etching technique after silicon-silicon bonding,avoiding deformation during the preparation process.In addition,due to the small gap between the membrane and the inlet/outlet holes,the dead volume of the microvalve was very small.The test results indicated that the micro-valve achieved flow control and ON/OFF functions with good repeatability.
3.A Monolithic Integrated Gas Chromatography Chip with Gas Chromatographic Column and Helium Discharge Ionization Detector
Yu-Chen ZHU ; Shao-Jie MA ; Wen-Bo LI ; Zhi-Rui LI ; Bin ZHAO ; Fei FENG
Chinese Journal of Analytical Chemistry 2025;53(7):1064-1071
A monolithic integrated gas chromatography chip,consisting of a micro gas chromatography column(μGCC)and a micro helium discharge ionization detector(μHDID)was proposed.The chip was fabricated using micro electromechanical system(MEMS)technique,and its sensitivity was improved from two aspects.On one hand,open tubular column was selected as the separation device,and the auxiliary helium channel width of μHDID was modulated based on the microchannel width of the μGCC to match the flow rates of μHDID and μGCC.On the other hand,the electrode structure inside the μHDID collection zone was optimized,a bias electrode group around the collection electrode was constructed,and the ion collection efficiency was improved.After coating HKUST-1 as the stationary phase,the monolithic integrated gas chromatography chip could achieve baseline separation and detection of light hydrocarbon gas mixture(methane,ethane,propane,andn-butane),with a detection limit for propane as low as 25 pg.The chip could carried out test under temperature-programmed conditions,with a resolution of 9.24 for ethane and propane.
4.A Micro Gas Chromatographic Column with Large Surface Area Based on Anodization
Shao-Jie MA ; Wen-Bo LI ; Yu-Chen ZHU ; Bo-Xin CHEN ; Zhi-Rui LI ; Bin ZHAO ; Fei FENG
Chinese Journal of Analytical Chemistry 2025;53(10):1607-1614
A micro gas chromatographic column with mesoporous surface micro column array prepared by anodization method was proposed.A porous support layer with a characteristic pore size of about 30 nm inside the chromatographic column was prepared in situ using anodization method,and a uniform alumina stationary phase was deposited on the mesoporous support layer using atom layer deposition(ALD)technique.The existence of a mesoporous support layer increased surface area of the chromatographic column,thereby increasing the total amount of stationary phase loading and enhancing column capacity,which facilitated chromatographic separation.The test results showed that the porous support layer significantly reduced the longitudinal molecular diffusion and mass transfer resistance of the micro gas chromatographic column,and significantly increased the number of theoretical plates(n-nonane increased by 290.2%).Furthermore,column efficiency of the chromatographic column was less affected by flow rate,which was conducive to rapid separation of heavy hydrocarbon mixtures.
5.An Electronic Microbial Growth Analyzer-based Method for Rapidly Screening Viable Salmonella in Food
Ruo-Han LIANG ; Xiao-Dan PU ; Feng LU ; Xue-Ting ZHU ; Yuan-Yuan ZHANG ; Xiao-Yang WANG ; Qian-Qian YANG ; Hao LI ; Xu-Zhi ZHANG ; Chen-Zhong LI ; Shan LIU
Chinese Journal of Analytical Chemistry 2025;53(10):1694-1704
Foodborne illnesses caused by Salmonella pose significant threats to worldwide public health safety.In this study,a rapid method for screening viable Salmonella in oyster sauce and milk was developed by utilizing an electronic microbial growth analyzer(EMGA).Target food samples were diluted 10-fold with RVS broth and loaded into test tubes.Test tubes were positioned in the EMGA to determine the bacterial growth curves and the time required to reach the maximum growth rate(Tmgr).Using Salmonella typhimurium(S.typhimurium)asan model species,there was linear relationship between the logarithmic value of viable bacterial concentration(lgC)and Tmgr over the range of 5×101-5×106 CFU/mL,with a detection limit of 10 CFU/mL.For oyster sauce,the regression equation was Tmgr(min)=-80.775lg[C/(CFU/mL)]+754.96(R2=0.9907),and the recovery rates of S.typhimurium ranged from 95.2%to 119.8%,with relative standard deviations(RSD)ranging from 3.5%to 16.3%.For milk,the regression equation was Tmgr(min)=-71.922 lg[C/(CFU/mL)]+618.65(R2=0.9985),with recovery rates ranging from 98.4%to 110.6%and RSD ranging from 6.4%to 12.8%.The EMGA method required only one portable instrument,and involving only three manual steps,i.e.,dilution,transfer,and insertion.When S.typhimurium contamination reached 106 CFU/mL,the total time consumption,from the unwrapping of samples to the readout of bacterial concentration,was no more than 7 h.When applied to detection of actual oyster sauce and milk samples,the new method demonstrated strong consistency with plate counting results in positive detection rates.This method was superior to the plate counting method,which was generally considered as a gold standard,in terms of accuracy,precision,simplicity and efficiency,representing a promising alternative for the on-site screening and quantification of viable Salmonella in oyster sauce and milk products.
6.Creation and Exploration of the"Organized Fill-in-the-Blank Format"Disci-pline Construction Model for Forensic Medicine in the New Era
Zhi-Wen WEI ; Hong-Xing WANG ; Jun-Hong SUN ; Hao-Liang FAN ; Hong-Liang SU ; Le-Le WANG ; Wen-Ting HE ; Zhe CHEN ; Jie ZHANG ; Xiang-Jie GUO ; Ji LI ; Geng-Qian ZHANG ; Xin-Hua LIANG ; Jiang-Wei YAN ; Qiang-Qiang ZHANG ; Cai-Rong GAO ; Ying-Yuan WANG ; Hong-Wei WANG ; Jun XIE ; Bo-Feng ZHU ; Ke-Ming YUN
Journal of Forensic Medicine 2025;41(1):25-29
Forensic medicine has been designated as a first-level discipline,presenting new opportunities and challenges for the development of forensic medicine.Since the 1980s,the establishment of foren-sic medicine discipline and the cultivation of high-level forensic talents have become hot topics in the development of forensic medicine in China.Since the 13th Five-Year Plan,the forensic team of Shanxi Medical University has been aiming at the forefront,proposing the development goals of"Five First-class"and the discipline development path"Six Major Achievements".It has selected benchmark disci-plines,identified gaps in disciplinary development,unified thoughts,formulated completion timelines,concentrated superior resources,assigned tasks to individuals,and created an"Organized Fill-in-the-Blank Format"forensic medicine discipline construction model with the characteristics of the new era.The construction model of forensic medicine has achieved good results in the goals,discipline frame-work,scientific research,talent cultivation,discipline team and platform construction,forming a rela-tively complete discipline construction and management system,and accumulating valuable experience for the construction of first-level discipline and high-level talent cultivation of forensic medicine.
7.Validation and Forensic Application of a Domestic Human DNA Quantitative De-tection Kit
Jing CHEN ; Ya-Ping WANG ; Yun-Peng FENG ; Xiao-Xin HU ; Zhen-Jun JIA ; Hong-Di LIU ; An-Xin YAN ; Yong-Jiu LI ; Zhu PENG ; Zhi-Fang LIU ; Jian-Gang CHEN
Journal of Forensic Medicine 2025;41(3):252-259
Objective To verify the efficacy of a domestic human DNA quantification kit based on real-time fluorescence quantitative PCR in detecting the total human DNA concentration,male DNA concen-tration in mixed male/female DNA samples,the degree of DNA degradation and inhibitor tolerance.Methods Samples with different concentrations,different male/female ratios,different concentrations of inhibitors,and different degradation degrees were tested using the domestic human DNA quantification kit based on real-time fluorescence quantitative PCR.This kit was compared with a similar product on the market and was applied to the detection of DNA from real cases.Results This human DNA quan-tification kit can effectively detect human DNA as low as 0.001 65 ng/μL,and 6.25 pg/μL of male DNA in mixed samples with a male-to-female ratio of 1∶15 000.Even when the sample contains as high as 400 ng/μL of humic acid or 1 000 μmol/L of hemin alone,the DNA concentration can still be accurately detected.The degradation index can effectively characterize the degradation degree of the sample.This kit has been successfully applied in forensic practice.Conclusion This human DNA quan-tification kit is accurate and reliable in detection.It can accurately reflect the degradation of DNA and inhibitor tolerance.It has good performance in quantitative accuracy,determination of the male/female ratio in mixed samples,and inhibitor tolerance.It has application potential in forensic case examination.
8.Detection of Ketamine and Norketamine Using an Aptamer-Functionalized Gra-phene Oxide Fluorescent Sensor
Li-Xia WEI ; Bo LIU ; Xiao-Yuan YANG ; Xi ZHANG ; Yi-Feng LAN ; Chao ZHANG ; Juan JIA ; Dan ZHANG ; Zhi-Wen WEI ; Ke-Ming YUN ; Zhe CHEN
Journal of Forensic Medicine 2025;41(4):326-339
Objective To construct an aptamer-functionalized carboxylated graphene oxide(CGO)fluo-rescent sensor to achieve highly sensitive and specific detection of ketamine(KET)and its metabolite norketamine(NK)using an aptamer capable of simultaneously recognizing KET and NK.Methods A specific aptamer for simultaneous recognition of KET and NK was screened using graphene oxide-sys-tematic evolution of ligand by exponential enrichment(GO-SELEX)and molecular docking tech-niques.The aptamer,labeled with Cy5 fluorescence,was chemically conjugated to CGO to construct an aptamer-functionalized CGO fluorescent sensor.By optimizing detection conditions,including the mass concentration of CGO,aptamer concentration,reaction temperature,and incubation time,quantita-tive analysis of the target analytes was achieved using the ratio of fluorescence intensity changes be-fore and after target addition.The stability of the sensor in biological matrices was evaluated by moni-toring fluorescence intensity changes over incubation time in blank blood and urine,in comparison with the traditional physical adsorption-based CGO fluorescent sensor.Spiked recovery experiments in blank blood and urine were conducted to compare performance with that of HPLC-MS/MS.Results A specific aptamer A5 was selected and chemically conjugated with CGO to construct the aptamer-functionalized CGO fluorescent sensor.Under optimized conditions,the proposed fluorescent sensor ex-hibited a linear detection range of 1.0-5.0 ng/mL for KET,with a limit of detection(LOD)of 0.86 ng/mL;while for NK,the linear detection range was 1.0-5.0 ng/mL,with an LOD of 0.70 ng/mL.Com-pared with the CGO fluorescent sensor constructed via physical adsorption,this sensor demonstrated greater stability in blood and urine.The spiked recovery rates of KET and NK in blank blood and urine ranged from 81.50%to 110.03%,exhibiting detection performance comparable to that of HPLC-MS/MS.Conclusion The aptamer screening method offers a novel approach for selecting aptamers tar-geting drugs and their metabolites.The constructed aptamer-functionalized CGO fluorescent sensor pro-vides an efficient and reliable strategy for the high-performance detection of KET and NK.
9.Toxicokinetics of Chlorfenapyr and Its Metabolites in Rats
Wen-Yan LI ; Jin-Feng ZHAO ; Wei-Chen LIU ; Shi-Jing LÜ ; Jia-Xin ZHANG ; Xu-Dong ZHANG ; Zhi-Wen WEI ; Ke-Ming YUN ; Chao ZHANG
Journal of Forensic Medicine 2025;41(4):380-386
Objective To establish a chromatography-tandem mass spectrometry method for detecting chlorfenapyr and its metabolite tralopyril in blood,and to investigate the toxicokinetics in rats.Methods Chlorfenapyr(8 mg/kg)was administered orally to rats,and blood samples were collected from rats'canthus vein at 5 min,15 min,30 min,1 h,3 h,6 h,12 h,24 h and 48 h after administration.The blood samples were extracted using 100 μL of 5%formic acid solution and 400 μL of acetonitrile.Chlorfena-pyr was qualitatively and quantitatively detected by triple quadrupole gas chromatography-tandem mass spectrometry(GC-MS/MS)and tralopyril was detected by triple quadrupole liquid chromatography-tandem mass spectrometry(LC-MS/MS).The DAS 3.0 software was used to fit the toxicokinetic equa-tions and calculate the toxicokinetic parameters.Results Chlorfenapyr was detectable from 5 min to 24 h with a peak time of 1 h.Tralopyril was detectable from 15 min to 48 h with a peak time of 3 h.The toxicokinetic process of chlorfenapyr in rat blood conformed to a first-order absorption one-compartment open model,with the toxicokinetic equation described as C=e-0.265t-e-0.175t.Tralopyril con-formed to the first-order absorption three-compartment model,and the toxicokinetic equation was C=47 361.069e-2.209t-35 404.962e-1.486t+11 956.363e-0.512t.In the equations,C stands for the concentration of the target substance in the blood,e is the natural constant(≈2.718 28),and t stands for time.Conclu-sion This study optimized the detection method for chlorfenapyr and its metabolite tralopyril in blood.The toxicokinetic equations and parameters of chlorfenapyr and tralopyril can provide a reference for the estimation of oral intake time of chlorfenapyr.
10.Important factors affecting depression:modulatory effects of Cx43 on neuroinflammation
Xuan ZENG ; Zi-han YAN ; Zhi-feng TIAN ; Hong-bin WANG ; Qi-di AI ; Mei-yu LIN ; Xuan LIU ; Nai-hong CHEN ; Song-wei YANG ; Yan-tao YANG
Chinese Pharmacological Bulletin 2025;41(11):2027-2031
Numerous studies have shown that depression is main-ly associated with the abnormal expression of connexin 43(Cx43)in astrocytes(Astro)and its mediated dysfunction of gap junction(GJ).However,the molecular mechanism of post-translational modifications targeting Cx43 to regulate neuroin-flammation-associated depression is still unclear.Post-transla-tional modifications of Cx43 mainly include phosphorylation of specific amino acid sites by PKC,PKA,PKG,MAPK and PTK,and protein degradation of Cx43 through the K48/K63 polyubiq-uitylation and deubiquitination pathways,which ultimately lead to protein degradation through K48/K63 polyubiquitination and deubiquitination.These modifications are ultimately involved in the regulation of neuroinflammatory responses through the associ-ation of GJ function.In this paper,we systematically review the role of Cx43 post-translational modifications in neuroinflamma-tion,with the aim of further exploring the potential application of targeting these modifications to modulate the inflammatory re-sponse mechanism in improving depressive symptoms.

Result Analysis
Print
Save
E-mail