1.Study on assessment methods for acetabular cup size in total hip arthroplasty.
Jinzi WANG ; Wenju CHANG ; Pei ZHANG ; Xiang LI ; Yong ZHANG ; Shuoshuo ZHANG ; Hai DING
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(2):163-167
OBJECTIVE:
To evaluate precise assessment methods for predicting the optimal acetabular cup size in total hip arthroplasty (THA).
METHODS:
A clinical data of 73 patients (80 hips) who underwent primary THA between December 2022 and July 2024 and met the inclusion criteria was analyzed. There were 39 males and 34 females with an average age of 66.3 years (range, 56-78 years). Among them, 66 cases were unilateral THA and 7 were bilateral THAs. There were 29 patients (34 hips) of osteoarthritis, 35 patients (35 hips) of femoral neck fractures, and 9 patients (11 hips) of osteonecrosis of the femoral head. Based on anteroposterior pelvic X-ray films, three methods were employed to predict acetabular cup size, including preoperative template planning, radiographic femoral head diameter (FHD) measurement, and intraoperative FHD measurement. The predicted acetabular cup sizes from these methods were compared with the actual implanted sizes.
RESULTS:
The predicted acetabular cup sizes using the preoperative template planning, radiographic FHD measurement, and intraoperative FHD measurement were (51.25±2.81), (49.72±3.11), and (49.90±2.74) mm, respectively, compared to the actual implanted cup size of (50.57±2.74) mm, with no significant difference ( P>0.05). Regarding agreement with the actual implanted cup size, the preoperative template planning achieved exact matches in 35 hips (43.75%), one-size deviation in 41 hips (51.25%), and two-size deviations in 4 hips (5%); the radiographic FHD measurement achieved exact matches in 12 hips (15%), one-size deviation in 57 hips (71.25%), and two-size deviations in 11 hips (13.75%); and the intraoperative FHD measurement achieved exact matches in 26 hips (32.5%), one-size deviation in 52 hips (65%), and two-size deviations in 2 hips (2.5%). There were significant differences in agreement distributions between the three methods and the actual implanted cup sizes ( H=18.579, P<0.001).
CONCLUSION
The intraoperative FHD measurement, as a simple, cost-effective, and accurate method, effectively guides acetabular cup selection, reduces the risk of prosthesis wear, enhances postoperative joint stability.
Humans
;
Arthroplasty, Replacement, Hip/instrumentation*
;
Male
;
Female
;
Middle Aged
;
Acetabulum/diagnostic imaging*
;
Aged
;
Hip Prosthesis
;
Prosthesis Design
;
Femur Head/surgery*
;
Osteoarthritis, Hip/surgery*
;
Radiography
;
Femoral Neck Fractures/surgery*
;
Femur Head Necrosis/surgery*
2.Clinical study of double-channel core decompression combined with medullary cavity irrigation for non-traumatic osteonecrosis of femoral head.
Jinhui MA ; Hongxu LI ; Haoyang LIU ; Bailiang WANG ; Weiguo WANG ; Fuqiang GAO ; Wei SUN ; Liming CHENG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(4):399-405
OBJECTIVE:
To compare the effects of double-channel core decompression (CD) combined with medullary cavity irrigation with those of simple CD on progression of collapse and clinical outcomes in non-traumatic osteonecrosis of the femoral head (ONFH).
METHODS:
A retrospective analysis was conducted on the clinical data of 19 patients (30 hips) with non-traumatic ONFH who underwent double-channel CD combined with medullary cavity irrigation and admitted between January 2024 and October 2024 (CD+irrigation group). According to a 1: 2 ratio, 54 patients (60 hips) who underwent simple CD and were matched in terms of age, gender, and body mass index (BMI) were included as the control (CD group). There was no significant difference in baseline data such as age, gender, BMI, affected side, ONFH type, preoperative Association Research Circulation Osseous (ARCO) stage, bone marrow edema stage, visual analogue scale (VAS) score for pain, and Harris score between the two groups ( P>0.05). The postoperative discharge time and occurrence of complications were recorded for both groups. The VAS scores before operation and at discharge after operation were compared, and the differences between pre- and post-operation (change values) were calculated for intergroup comparison. The Harris scores before operation and at discharge and 3 months after operation were also compared. During follow-up, X-ray film, CT, and MRI were performed for reexamination. The ARCO stage and bone marrow edema stage were evaluated at 3 months after operation and compared with those before operation to determine whether there was radiological progression or relief.
RESULTS:
All incisions in both groups healed by first intention after operation, with no infection, femoral neck fracture, or other operation-related complications. All patients were followed up, and the follow-up time of the CD+irrigation group was (146.8±27.7) days, and that of the CD group was (164.3±48.2) days; there was no significant difference between the two groups ( t=1.840, P=0.069). There was no significant difference in the length of hospital stay between the two groups ( P>0.05). At discharge after operation, the VAS score of the CD+irrigation group was significantly lower than that of the CD group ( P<0.05), and the change value was significantly higher than that of the CD group ( P<0.05). The Harris scores at discharge and 3 months after operation in the CD+irrigation group were significantly higher than those in the CD group ( P<0.05). The Harris score gradually increased with time, and the differences between different time points were significant ( P<0.05). Radiological reexamination showed that there was no significant difference in the ARCO stage and the incidence of radiological progression between the two groups at 3 months after operation ( P>0.05); however, the bone marrow edema stage and the degree of bone marrow edema relief in the CD+irrigation group were better than those in the CD group, with significant differences ( P<0.05).
CONCLUSION
Double-channel CD combined with medullary cavity irrigation can significantly alleviate hip joint pain and improve joint function in patients with non-traumatic ONFH, reduce the degree of bone marrow edema in the femoral head, and delay the progression of ONFH.
Humans
;
Femur Head Necrosis/therapy*
;
Retrospective Studies
;
Male
;
Female
;
Decompression, Surgical/methods*
;
Therapeutic Irrigation/methods*
;
Adult
;
Treatment Outcome
;
Middle Aged
;
Femur Head/surgery*
3.Direct anterior craniocervical junction fenestration decompression and bone graft for the treatment of early and middle stage osteonecrosis of the femoral head: a 3-year follow-up.
Yan-Bai CHEN ; Wei-Kai QIN ; Qi YAN ; Ao-Lin SUN ; Hong-Mei ZHANG
China Journal of Orthopaedics and Traumatology 2025;38(7):680-686
OBJECTIVE:
To assess the mid-term clinical efficacy of the direct anterior approach for window decompression and bone grafting surgery in the treatment of early to mid-stage osteonecrosis of the femoral head (ONFH).
METHODS:
A retrospective analysis was performed on 40 patients (40 hips) diagnosed with osteonecrosis of the femoral head (ONFH), classified as types L1 and L2 according to the China-Japan Friendship Hospital (CJFH) classification system, and at stagesⅡ, ⅢA, and ⅢB based on the Association Research Circulation Osseous (ARCO) staging system. All patients underwent head-neck junction fenestration decompression and bone grafting via the direct anterior approach between January 2015 and May 2022, with complete follow-up data available for a minimum of three years. The ages of the patients ranged from 35 to 69 years old, with a mean of (49.13±6.14 ) years old;their body mass index (BMI) ranged from 20.02 to 27.94 kg·m-2, with a mean of (23.65±1.69) kg·m-1;the duration of the disease ranged from 13 to 36 months, with a mean of (24.55±4.14) months. Preoperative and 3-year postoperative X-ray parameters were collected, including the anterior preserved angle(APA), lateral preserved angle (LPA), and combined preserved angle (CPA). Additionally, hip joint disability and osteoarthritis outcome scores (HOOS) and Harris hip scores (HHS) were recorded.
RESULTS:
Forty patients were followed up for a period ranging from 36 to 59 months, with a mean duration of (47.18±6.18) months. At 3 years postoperative, none of the patients underwent hip replacement surgery. The APA (73.15±19.35)°, LPA (75.35 ±21.48)°, and CPA (136.25±26.78)° at the 3-year postoperative significantly improved compared to preoperative measurements (61.93±20.54)°, (59.46±22.67)°, and (116.58±32.47)°, with statistical significance (P<0.05). The HOOS (20.37±1.39) and HHS (89.74±3.28) scores at the 3-year postoperative were significantly improved from preoperative scores (12.36±1.58) and (50.27±6.15), respectively, with statistical significance (P<0.05).
CONCLUSION
The direct anterior approach for window decompression and bone grafting surgery can relieve joint pain, improve joint function, and enhance X-ray preserved angles, effectively preventing femoral head collapse, making it an effective surgical method for treating ONFH classified as L1, L2 according to CJFH and stagesⅡ, ⅢA, ⅢB according to ARCO.
Humans
;
Middle Aged
;
Male
;
Female
;
Adult
;
Decompression, Surgical/methods*
;
Bone Transplantation
;
Femur Head Necrosis/surgery*
;
Follow-Up Studies
;
Aged
;
Retrospective Studies
4.Disastrous triad of femoral head:femoral neck fracture meeting fracture-dislocation of femoral head.
China Journal of Orthopaedics and Traumatology 2023;36(3):216-221
Femoral head and ipsilateral femoral neck fractures are serious and complicated injuries, which usually yield unsatisfactory results using conventional hip-preserving surgery. The key point of the management and prognosis mainly lies in femoral neck fractures. An apparent and consecutive relationship exists between femoral neck fractures and femoral head fracture-hip dislocation in such injuries. It is believed that disastrous triad of femoral head (DTFH) could summarize these specific injuries, and reflect the injury mechanism and prognostic characteristics. Based on our clinical observation and literature review, DTFH could be divided into three subgroups:TypeⅠ, common DTFH, in which femoral neck fractures occur following femoral head fractures-hip dislocation due to the same trauma; TypeⅡ, iatrogenic DTFH, in which femoral neck fractures come out in the caring process of femoral head fractures-hip dislocation; Type Ⅲ, stressed DTFH, in which femoral neck fractures occur after the management of femoral head fractures-hip dislocation. In the scenario, the line of femoral neck fractures locates distally to the femoral head fractures. Herein, we will discuss clinical characteristics of these types of DTFH.
Humans
;
Femoral Fractures/complications*
;
Femoral Neck Fractures/complications*
;
Femur Head/injuries*
;
Fracture Dislocation
;
Fracture Fixation, Internal/methods*
;
Hip Dislocation/surgery*
;
Prognosis
5.Imaging measurement and analysis of related indexes of variation of femoral head rotation center.
Yan-Shan SUN ; Ji-Cheng WANG ; Chang-Kun WU ; Yong-Zhi GAO ; Jiang XIN ; Yang-Yang ZHANG
China Journal of Orthopaedics and Traumatology 2023;36(3):284-288
OBJECTIVE:
To provide guidance for hip replacement by analyzing the variation of femoral head rotation center in different hip diseases.
METHODS:
A total of 5 459 patients were collected from March 2016 to June 2021, who took positive and proportional plain films of both hips for various reasons. The relative position between the rotation center of the femoral head and the apex of the greater trochanter was measured. The positive variation is more than 2 mm above the top of the great trochanter, and the negative variation is more than 2 mm below the top of the great trochanter. A total of 831 patients with variation of femoral head rotation center were collected and were divided into 4 groups according to different diseases, and the variation was counted respectively. There were 15 cases in the normal group involving 10 cases of positive variation and 5 cases of negative variation. There were 145 cases of avascular necrosis of femoral head involving 25 cases of positive variation and 120 cases of negative variation. There were 346 cases of congenital hip dysplasia involving 225 cases of positive variation(including 25 cases of typeⅠ, 70 cases of type Ⅱ, 115 cases of type Ⅲ and 15 cases of type Ⅳ), and 121 cases of negative variation(including 50 cases of crowe typeⅠ, 60 cases of typeⅡ, 10 cases of type Ⅲ and 1 case of type Ⅳ). There were 325 cases of hip osteoarthritis group involving 45 cases of positive variation and 280 cases of negative variation.
RESULTS:
There was significant difference in variation of femoral head rotation center among the four groups(P<0.05). There was significant difference in variation of femoral head rotation center among different types of congenital hip dysplasia(P<0.05). There were significant differences in cervical trunk angle and eccentricity among different variations of femoral head rotation center(P<0.05).
CONCLUSION
The variation of femoral head rotation center is related to cervical trunk angle and eccentricity. The variation of femoral head rotation center is an important factor in hip diseases. The variation of femoral head rotation center is different in different hip diseases. Avascular necrosis of the femoral head and osteoarthritis of the hip were mostly negative variations. With the aggravation of congenital hip dysplasia, the variation of femoral head rotation center gradually changed from negative variation to positive variation.The variation of femoral head rotation center should be paid attention to in the preoperative planning of hip arthroplasty. It is of great significance to select the appropriate prosthesis and place the prosthesis accurately.
Humans
;
Femur Head/surgery*
;
Hip Dislocation, Congenital/surgery*
;
Hip Prosthesis
;
Arthroplasty, Replacement, Hip/methods*
;
Femur/surgery*
;
Retrospective Studies
;
Treatment Outcome
6.Clinical study on core decompression in treating osteonecrosis of the femoral head of the necrotic bone-in different site.
Xu CUI ; Yang-Quan HAO ; Bo DONG ; Pu-Wei YUAN ; Yu-Fei ZHANG ; Wen-Xing YU ; Chao LU
China Journal of Orthopaedics and Traumatology 2023;36(3):289-294
OBJECTIVE:
To analyze the clinical effect of decompression and bone grafting on osteonecrosis of the femoral head(ONFH) at different sites of necrotic lesions.
METHODS:
A total of 105 patients with ARCOⅡstage ONFH admitted from January 2017 to December 2018 were retrospectively analyzed. There were 71 males and 34 females, with an average age of (55.20±10.98) years old. The mean course of all patients was(15.91±9.85) months. According to Japanese Inveatigation Committee (JIC) classification, all patients were divided into 4 types:17 cases of type A, 26 cases of type B, 33 cases of type C1 and 29 cases of type C2. All four groups were treated with decompression of the pulp core and bone grafting. Visual analogue scale(VAS) and Harris hip joint score were used before and at 3, 6, 12, and 24 months after the operation, and the collapse of the femoral head was observed by X-ray examination within 2 years.
RESULTS:
All 105 patients were successful on operation without complications, and the mean follow-up duration was (24.45±2.75) months. Harris score showed that there was no statistical difference among four groups before surgery and 3, 6 months after surgery (P>0.05);at 12 and 24 months after surgery, there were significant differences among all groups (P<0.01). There were significant differences in intragroup Harris scores at preoperative and postoperative time points among four groups (P<0.01). VAS showed that there was no statistical difference among four groups before and 3, 6 months after surgery (P>0.05);at 12 and 24 months after surgery, there were significant differences among all groups (P<0.01). There were significant differences in VAS at preoperative and postoperative time points among four groups (P<0.01). None of the patients in four groups had femoral head collapse before and 3, 6 months after surgery. At 12 months after operation, there were 3 cases of femoral head collapse in group C and 4 cases in group C2(P>0.05);At 24 months after operation, 1 case of femoral head collapse occurred in group B, 6 cases in group C1 and 8 cases in group C2(P<0.05).
CONCLUSION
Core decompression and bone grafting can improve the effect of ONFH and hip preservation. The effect of hip preservation for ONFH is closely related to the location of the osteonecrosis lesion, so the influence of the location of lesion on the effect of hip preservation should be considered in clinical treatment, so as to make better preoperative hip preservation plan.
Male
;
Female
;
Humans
;
Adult
;
Middle Aged
;
Aged
;
Retrospective Studies
;
Femur Head Necrosis/diagnosis*
;
Femur Head/surgery*
;
Treatment Outcome
;
Decompression, Surgical
;
Bone Transplantation
7.Assessment of the local blood supply when femoral neck fracture occurs:advances in the anatomy research and its clinical application.
Sheng-Hui WU ; Yu MIAO ; Xiao-Zhong ZHU ; Guang-Yi LI
China Journal of Orthopaedics and Traumatology 2023;36(3):294-298
The stability of internal fixation of femoral neck fractures can be obtained through surgical techniques, the configuration of screws and bone grafting, etc. However, the blood supply injury caused by fractures could not be completely reversed by the current medical management. Hence, the comprehensive evaluation of the residual blood supply of the femoral neck, to perioperatively avoid further iatrogenic injury, has become a hotspot. The anatomy of the extraosseous blood supply of the femoral neck has been widely reported, while its clinical application mostly involved the assessment of the medial circumflex femoral artery and retinacular arteries. However, further studies are needed to explore the prognosis of patients with these artery injuries, with different degrees, caused by femoral neck fractures. Direct observations of nutrient foramina in vivo are not possible with current clinical technologies, but it is possible to make reasonable preoperative planning to avoid subsequent femoral head necrosis based on the distribution features of nutrient foramina. The anatomy and clinical application studies of the intraosseous blood supply focused on the junction area of the femoral head and neck to probe the mechanism of femoral head necrosis. Thus, the intraosseous blood supply of other regions in the femoral neck remains to be further investigated. In addition, a blood supply evaluation system based on a three-level structure, extraosseous blood vessels, nutrient foramina, and intraosseous vascular network, could be explored to assist in the treatment of femoral neck fractures.
Humans
;
Femur Head Necrosis
;
Femoral Neck Fractures/surgery*
;
Femur Neck
;
Femur Head/surgery*
;
Femoral Artery
;
Fracture Fixation, Internal
9.Study on effectiveness of treating femoral neck fractures based on theory of "positive support".
Liu YANG ; Gang MO ; Lin XU ; Yang LI ; Shiqiang RUAN
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(8):958-963
OBJECTIVE:
To explore effectiveness of positive support reduction and internal fixation in the treatment of femoral neck fractures.
METHODS:
A clinical data of 74 patients with femoral neck fractures treated with hollow screw internal fixation between September 2017 and September 2021 was retrospectively analyzed. Based on the quality of fracture reduction, they were divided into positive support reduction group (group A, n=25), negative support reduction group (group B, n=21), and anatomical reduction group (group C, n=28). There was no significant difference in baseline data such as gender, age, cause of injury, disease duration, fracture side, Garden classification, and fracture line position classification between groups (P>0.05). The occurrence of complications such as early fixation failure, femoral neck shortening, non-union of fractures, and femoral head necrosis in three groups, as well as the Harris score of the hip joint were recorded and compared.
RESULTS:
All patients had primary healing of incisions after operation and were followed up more than 12 months. The follow-up time for groups A, B, and C was (21.1±5.7), (22.6±4.3), and (21.9±4.1) months, respectively; there was no significant difference between groups (P>0.05). There was no significant difference in the incidences of non-union of fractures, early internal fixation failure, and the femoral head necrosis between groups (P>0.05). The incidence and length of femoral neck shortening, and the hip Harris score at last follow-up in groups A and C were all superior to those in the group B, with significant difference (P<0.05). There was no significant difference in the above indicators between groups A and C (P>0.05).
CONCLUSION
Positive support reduction can provide a good biomechanical environment for the healing of femoral neck fractures, thereby achieving a higher fracture healing rate, reducing the occurrence of femoral neck shortening, minimizing the function of hip joint, and achieving effectiveness similar to anatomical reduction.
Humans
;
Femur Head Necrosis
;
Retrospective Studies
;
Femoral Neck Fractures/surgery*
;
Femur Neck
;
Plastic Surgery Procedures
10.Mid-term effectiveness of hip preservation in the reconstruction of ultrashort bone segments in the proximal femur with three-dimensional printed customized cementless intercalary endoprosthesis with an intra-neck curved stem.
Hongtao SHENG ; Yuqi ZHANG ; Qi YOU ; Taojun GONG ; Zhuangzhuang LI ; Xuanhong HE ; Fan TANG ; Yong ZHOU ; Yitian WANG ; Minxun LU ; Yi LUO ; Li MIN ; Chongqi TU
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(8):970-977
OBJECTIVE:
To explore the design points of a three-dimensional (3D) printed customized cementless intercalary endoprosthesis with an intra-neck curved stem and to evaluate the key points and mid-term effectiveness of its application in the reconstruction of ultrashort bone segments in the proximal femur.
METHODS:
Between October 2015 and January 2021, 17 patients underwent reconstruction with a 3D printed-customized cementless intercalary endoprosthesis with an intra-neck curved stem. There were 11 males and 6 females, the age ranged from 10 to 76 years, with an average of 30.1 years. There were 9 cases of osteosarcoma, 4 cases of Ewing sarcoma, 2 cases of chondrosarcoma, 1 case of liposarcoma, and 1 case of myofibroblastoma. The disease duration was 5-14 months, with an average of 9.5 months. Enneking staging included 16 cases of stage ⅡB and 1 case of stage ⅢB. The distances from the center of the femoral head to the body midline and the acetabular apex were measured preoperatively on X-ray images. Additionally, the distances from the tip of the intra-neck curved stem to the body midline and the acetabular apex were measured at immediate postoperatively and last follow-up. The neck-shaft angle was also measured preoperatively, at immediate postoperatively, and at last follow-up. The status of osseointegration at the bone-prosthesis interface and bone growth into the prosthesis surface were assessed by X-ray films, CT, and Tomosynthesis-Shimadzu metal artefact reduction technology (T-SMART). The survival status of the patients, presence of local recurrence or distant metastasis, and occurrence of postoperative complications were assessed. The recovery of lower limb function was evaluated pre- and post-operatively using the Musculoskeletal Tumor Society (MSTS) scoring system, and pain relief was evaluated using the visual analogue scale (VAS) scores.
RESULTS:
The patient's femoral resection length was (163.1±57.5) mm, the remaining proximal femoral length was (69.6±9.3) mm, and the percentage of femoral resection length/total femoral length was 38.7%±14.6%. All 17 patients were followed up 25-86 months with an average of 58.1 months. During the follow-up, 1 patient died of lung metastasis at 46 months postoperatively, and the remaining 16 patients survived tumor-free. There was no complication such as periprosthetic infection, delayed incision healing, aseptic loosening, prosthesis fracture, or periprosthetic fracture. No evidence of micromotion or wear around the implanted stem of the prosthesis was detected in X-ray and T-SMART evaluations. There was no significant radiolucent lines, and radiographic evidence of bone ingrowth into the bone-prosthesis interface was observed in all stems. There was no significant difference in the distance from the tip of the curved stem to the body midline and the apex of the acetabulum at immediate postoperatively and last follow-up compared with the distance from the center of the femoral head to the body midline and the apex of the acetabulum before operation, respectively (P>0.05), and there was no significant difference in the above indexes between immediate postoperatively and last follow-up (P>0.05). The differences in the neck-shaft angle at various time points before and after operation were also not significant (P>0.05). At last follow-up, the MSTS score was 26.1±1.2 and the VAS score was 0.1±0.5, which were significantly improved when compared with those before operation [19.4±2.1 and 5.7±1.0, respectively] (t=14.735, P<0.001; t=21.301, P<0.001). At last follow-up, none of the patients walked with the aid of crutches or other walkers.
CONCLUSION
The 3D printed customized cementless intercalary endoprosthesis with an intra-neck curved stem is an effective method for reconstructing ultrashort bone segments in the proximal femur following malignant tumor resection. The operation is reliable, the postoperative lower limb function is satisfactory, and the incidence of complications is low.
Female
;
Male
;
Humans
;
Child
;
Adolescent
;
Young Adult
;
Adult
;
Middle Aged
;
Aged
;
Femur/surgery*
;
Lower Extremity
;
Bone-Implant Interface
;
Femur Head
;
Artificial Limbs

Result Analysis
Print
Save
E-mail