1.Study on assessment methods for acetabular cup size in total hip arthroplasty.
Jinzi WANG ; Wenju CHANG ; Pei ZHANG ; Xiang LI ; Yong ZHANG ; Shuoshuo ZHANG ; Hai DING
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(2):163-167
OBJECTIVE:
To evaluate precise assessment methods for predicting the optimal acetabular cup size in total hip arthroplasty (THA).
METHODS:
A clinical data of 73 patients (80 hips) who underwent primary THA between December 2022 and July 2024 and met the inclusion criteria was analyzed. There were 39 males and 34 females with an average age of 66.3 years (range, 56-78 years). Among them, 66 cases were unilateral THA and 7 were bilateral THAs. There were 29 patients (34 hips) of osteoarthritis, 35 patients (35 hips) of femoral neck fractures, and 9 patients (11 hips) of osteonecrosis of the femoral head. Based on anteroposterior pelvic X-ray films, three methods were employed to predict acetabular cup size, including preoperative template planning, radiographic femoral head diameter (FHD) measurement, and intraoperative FHD measurement. The predicted acetabular cup sizes from these methods were compared with the actual implanted sizes.
RESULTS:
The predicted acetabular cup sizes using the preoperative template planning, radiographic FHD measurement, and intraoperative FHD measurement were (51.25±2.81), (49.72±3.11), and (49.90±2.74) mm, respectively, compared to the actual implanted cup size of (50.57±2.74) mm, with no significant difference ( P>0.05). Regarding agreement with the actual implanted cup size, the preoperative template planning achieved exact matches in 35 hips (43.75%), one-size deviation in 41 hips (51.25%), and two-size deviations in 4 hips (5%); the radiographic FHD measurement achieved exact matches in 12 hips (15%), one-size deviation in 57 hips (71.25%), and two-size deviations in 11 hips (13.75%); and the intraoperative FHD measurement achieved exact matches in 26 hips (32.5%), one-size deviation in 52 hips (65%), and two-size deviations in 2 hips (2.5%). There were significant differences in agreement distributions between the three methods and the actual implanted cup sizes ( H=18.579, P<0.001).
CONCLUSION
The intraoperative FHD measurement, as a simple, cost-effective, and accurate method, effectively guides acetabular cup selection, reduces the risk of prosthesis wear, enhances postoperative joint stability.
Humans
;
Arthroplasty, Replacement, Hip/instrumentation*
;
Male
;
Female
;
Middle Aged
;
Acetabulum/diagnostic imaging*
;
Aged
;
Hip Prosthesis
;
Prosthesis Design
;
Femur Head/surgery*
;
Osteoarthritis, Hip/surgery*
;
Radiography
;
Femoral Neck Fractures/surgery*
;
Femur Head Necrosis/surgery*
2.Effectiveness of guide plate with mortise-tenon joint structure combined with off-axis fixation in treatment of Pauwels type Ⅲ femoral neck fractures.
Xuanye ZHU ; Lijuan CUI ; Leilei ZHANG ; Yudong JIA ; Yingjie ZHU ; Youwen LIU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(3):284-289
OBJECTIVE:
To investigate the effectiveness of using 3 hollow compression screws combined with 1 screw off-axis fixation under the guidance of three-dimensional (3D) printed guide plate with mortise-tenon joint structure (mortise-tenon joint plate) for the treatment of Pauwels type Ⅲ femoral neck fractures.
METHODS:
A clinical data of 78 patients with Pauwels type Ⅲ femoral neck fractures, who were admitted between August 2022 and August 2023 and met the selection criteria, was retrospectively analyzed. The operations were assisted with mortise-tenon joint plates in 26 cases (mortise-tenon joint plate group) and traditional guide plates in 28 cases (traditional plate group), and without guide plates in 24 cases (control group). There was no significant difference in the baseline data of gender, age, body mass index, cause of injury, and fracture side between groups ( P>0.05). The operation time, intraoperative blood loss, frequency of intraoperative fluoroscopy, incision length, incidence of postoperative deep vein thrombosis of lower extremity, pain visual analogue scale (VAS) score at 1 week after operation, and Harris score of hip joint at 3 months after operation were recorded and compared. X-ray re-examination was taken to check the quality of fracture reduction, fracture healing, and the shortening length of the femoral neck at 3 months after operation, and the incidences of internal fixation failure and osteonecrosis of the femoral head during operation.
RESULTS:
Compared with the control group, the operation time, intraoperative blood loss, and frequency of intraoperative fluoroscopy reduced in the two plate groups, and the quality of fracture reduction was better, but the incision was longer, and the differences were significant ( P<0.05). The operation time and intraoperative blood loss were significantly higher in the traditional plate group than in the mortise-tenon joint plate group ( P<0.05), the incision was significantly longer ( P<0.05); and the difference in fracture reduction quality and the frequency of intraoperative fluoroscopy was not significant between two plate groups ( P>0.05). There was 1 case of deep vein thrombosis of lower extremity in the traditional plate group and 1 case in the control group, while there was no thrombosis in the mortise-tenon joint plate group. There was no significant difference in the incidence between groups ( P>0.05). All patients were followed up 12-15 months (mean, 13 months). There was no significant difference in VAS score at 1 week and Harris score at 3 months between groups ( P>0.05). Compared with the control group, the fracture healing time and the length of femoral neck shortening at 3 months after operation were significantly shorter in the two plate groups ( P<0.05). There was no significant difference between the two plate groups ( P>0.05). There was no significant difference in the incidences of non-union fractures, osteonecrosis of the femoral head, or internal fixation failure between groups ( P>0.05).
CONCLUSION
For Pauwels type Ⅲ femoral neck fractures, the use of 3D printed guide plate assisted reduction and fixation can shorten the fracture healing time, reduce the incidence of postoperative complications, and be more conducive to the early functional exercise of the affected limb. Compared with the traditional guide plate, the mortise-tenon joint plate can reduce the intraoperative bleeding and shorten the operation time.
Humans
;
Femoral Neck Fractures/diagnostic imaging*
;
Bone Plates
;
Fracture Fixation, Internal/instrumentation*
;
Male
;
Female
;
Retrospective Studies
;
Middle Aged
;
Bone Screws
;
Adult
;
Aged
;
Treatment Outcome
;
Printing, Three-Dimensional
;
Operative Time
3.Finite element analysis of adding one transverse screw for Pauwels type Ⅲ femoral neck fractures.
Luyao MA ; Xueao SUN ; Qingjun TAN ; Yanping LAN ; Xiaohu WANG ; Yunsheng YIN ; Jinhui MA
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(5):584-591
OBJECTIVE:
To investigate whether adding 1 transverse screw (TS) to the triangular parallel cannulated screw (TPCS) fixation has a mechanical stability advantage for Pauwels type Ⅲ femoral neck fractures by conducting finite element analysis on four internal fixation methods.
METHODS:
Based on CT data of a healthy adult male volunteer's femur, three Pauwels type Ⅲ femoral neck fracture models (Pauwels angle 70°, Pauwels angle 80°, and Pauwels angle 70° combined with bone defect) were constructed using Mimics 21.0 software and SolidWorks 2017 software. Four different internal fixation models were built at the same time, including TPCS, TPCS+TS, three cross screws (TCS), and TPCS+medial buttress plate (MBP). The mechanical stability of different models under the same load was compared by finite element analysis.
RESULTS:
The femoral model established in this study exhibited a maximum stress of 28.62 MPa, with relatively higher stress concentrated in the femoral neck. These findings were comparable to previous studies, indicating that the constructed femoral finite element model was correct. The maximum stress of internal fixation in finite element analysis showed that TCS was the lowest and TPCS+MBP was the highest in Pauwels angle 70° and 80° models, while TPCS+TS was the lowest and TCS was the highest in Pauwels angle 70° combined with bone defect model. The maximum displacement of internal fixation in each fracture model was located at the top of the femoral head, with TCS having the highest maximum displacement of the femur. The maximum stress of fracture surface in finite element analysis showed that TCS was the lowest and TPCS was the highest in the Pauwels angle 70° model, while TPCS+MBP was the lowest and TPCS/TCS were the highest in the Pauwels angle 80° model and the Pauwels angle 70° combined with bone defect model, respectively. The maximum displacement of fracture surfece analysis showed that TPCS+MBP was the lowest and TCS was the highest in Pauwels angle 70° and 80° models, while TPCS+TS was the lowest and TCS was the highest in Pauwels angle 70° combined with bone defect model.
CONCLUSION
For Pauwels type Ⅲ femoral neck fractures, the biomechanical stability of TPCS+TS was superior to that of TPCS alone and TCS, but it has not yet reached the level of TPCS+MBP.
Finite Element Analysis
;
Humans
;
Femoral Neck Fractures/diagnostic imaging*
;
Bone Screws
;
Fracture Fixation, Internal/instrumentation*
;
Male
;
Bone Plates
;
Stress, Mechanical
;
Biomechanical Phenomena
;
Tomography, X-Ray Computed
;
Adult
;
Femur Neck/surgery*
4.Analysis of effectiveness of Holosight robot navigation-assisted percutaneous cannulated screw fixation in treatment of femoral neck fractures.
Weizhen XU ; Zhenqi DING ; Hui LIU ; Jinhui ZHANG ; Yuanfei XIONG ; Jin WU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(6):673-679
OBJECTIVE:
To investigate the effectiveness of Holosight robotic navigation-assisted percutaneous cannulated screw fixation for femoral neck fractures.
METHODS:
A retrospective analysis was conducted on 65 patients with femoral neck fractures treated with cannulated screw fixation between January 2022 and February 2024. Among them, 31 patients underwent robotic navigation-assisted screw placement (navigation group), while 34 underwent conventional freehand percutaneous screw fixation (freehand group). Baseline characteristics, including age, gender, fracture side, injury mechanism, Garden classification, Pauwels classification, and time from injury to operation, showed no significant differences between the two groups ( P>0.05). The operation time, intraoperative blood loss, fluoroscopy frequency, fracture healing time, and complications were recorded and compared, and hip function was evaluated by Harris score at last follow-up. Postoperative anteroposterior and lateral hip X-ray films were taken to assess screw distribution accuracy, including deviation from the femoral neck axis, inter-screw parallelism, and distance from screws to the femoral neck cortex.
RESULTS:
No significant difference was observed in operation time between the two groups ( P>0.05). However, the navigation group demonstrated superior outcomes in intraoperative blood loss, fluoroscopy frequency, deviation from the femoral neck axis, inter-screw parallelism, and distance from screws to the femoral neck cortex ( P<0.05). No incision infections or deep vein thrombosis occurred. All patients were followed up 12-18 months (mean, 16 months). In the freehand group, 1 case suffered from cannulated screw dislodgement and nonunion secondary to osteonecrosis of femoral head at 1 year after operation, 1 case suffered from screw penetration secondary to osteonecrosis of femoral head at 5 months after operation; and 1 case suffered from nonunion secondary to osteonecrosis of femoral head at 6 months after operation in the navigation group. All the 3 patients underwent internal fixators removal and total hip arthroplasty. There was no significant difference in the incidence of complications between the two groups ( P>0.05). The fracture healing time and hip Harris score at last follow-up in the navigation group were significantly better than those in the freehand group ( P<0.05).
CONCLUSION
Compared to freehand percutaneous screw fixation, Holosight robotic navigation-assisted cannulated screw fixation for femoral neck fractures achieves higher precision, reduced intraoperative radiation exposure, smaller incisions, and superior postoperative hip function recovery.
Humans
;
Femoral Neck Fractures/diagnostic imaging*
;
Bone Screws
;
Fracture Fixation, Internal/instrumentation*
;
Male
;
Female
;
Retrospective Studies
;
Robotic Surgical Procedures/methods*
;
Middle Aged
;
Aged
;
Adult
;
Treatment Outcome
;
Operative Time
;
Fracture Healing
;
Surgery, Computer-Assisted/methods*
;
Fluoroscopy
5.Short-to-medium-term clinical efficacy of total hip arthroplasty with Pinnacle ES constrained liner in the treatment of femoral neck fractures associated with lower limb neuromuscular disorders.
Can-Feng WANG ; Xiao-Qing WANG ; Lei HAN ; Yun-Gen HU ; Tuo WANG
China Journal of Orthopaedics and Traumatology 2025;38(11):1151-1155
OBJECTIVE:
To investigate the short-to-medium-term clinical efficacy of total hip arthroplasty(THA) with Pinnacle ES constrained liner in the treatment of femoral neck fractures(FNF) associated with lower limb neuromuscular disorders.
METHODS:
A retrospective analysis was conducted on 16 patients who underwent primary THA using Pinnacle ES constrained liner for FNF with lower limb neuromuscular disorders and had complete follow-up data, treated between January 2020 and January 2023. There were 7 males and 9 females, with a mean age of (68.42±3.58) years old ranging from 61 to 75 years old. Among them, 10 cases had left-sided fractures and 6 had right-sided fractures;based on the Garden classification, 11 cases were type Ⅲ and 5 cases were type Ⅳ. The affected limbs were complicated with sequelae of poliomyelitis (2 cases), Parkinson's disease (2 cases), and sequelae of cerebral infarction (12 cases). All operations were performed via a posterolateral approach. Prosthesis position was evaluated using imaging data. Hip function was assessed by the Harris hip score(HHS) and Merle D'Aubigne hip score. During the follow-up period, the occurrence of complications such as prosthetic dislocation, loosening, and infection was recorded.
RESULTS:
One patient died of advanced tumor 2 years after surgery, and the remaining 15 patients were followed up for 24 to 64 months with a mean of (34.8±5.5) months. The operation time ranged from 50 to 90 minutes with a mean of (75.56±8.15) minutes, and the blood loss ranged from 150 to 200 ml with a mean of (170.32±12.56) ml. All patients achieved primary wound healing after surgery. Intraoperatively, femoral calcar splitting occurred in 2 cases, which were treated with titanium cable binding;no neurovascular injuries were observed in any case. The mean HHS increased from (18.95±2.25) preoperatively to (88.02±2.42) at the last follow-up, and the mean Merle D'Aubigne Score increased from (3.05±0.06) preoperatively to (16.65±0.93) at the last follow-up. Postoperative follow-up X-rays showed good prosthetic position, and no complications such as dislocation, prosthetic loosening, periprosthetic fracture, or deep infection occurred during the follow-up period.
CONCLUSION
Total hip arthroplasty with Pinnacle ES constrained liner is effective in the treatment of femoral neck fractures associated with lower limb neuromuscular disorders. It can significantly improve hip function, reduce the postoperative prosthetic dislocation rate, provide good initial stability, and achieve satisfactory short-to-medium-term clinical efficacy.
Humans
;
Male
;
Female
;
Middle Aged
;
Aged
;
Arthroplasty, Replacement, Hip/methods*
;
Femoral Neck Fractures/complications*
;
Retrospective Studies
;
Neuromuscular Diseases/surgery*
;
Lower Extremity
;
Treatment Outcome
6.Sparing piriformis and internus repairing externus vs. other conventional approaches for hip hemiarthroplasty: A report of early outcomes from a single UK trauma unit.
Michael APOSTOLIDES ; William THOMAS ; Darren LEONG ; Bogdan ROBU ; Nimesh PATEL
Chinese Journal of Traumatology 2025;28(5):324-329
PURPOSE:
Over 30,000 hip hemiarthroplasties for neck of femur fractures are performed annually in the United Kingdom (UK). The national recommendation is via the lateral approach, to reduce the risk of dislocation, with the potential expense of reduced function and mobility post-operatively. Muscle-sparing approaches, such as SPAIRE (sparing piriformis and internus repairing externus), have been invented to address the issue of dislocation.
METHODS:
We performed a retrospective data collection at a single center with a high annual volume of hip hemiarthroplasties over 12 months. All patients who had hip hemiarthroplasty as their primary treatment were included. Patients who passed away and were non-ambulant before their surgery were excluded from the study. Our primary outcome was the dislocation rate and secondary outcomes were the time to mobilization after surgery and the duration of surgery. Statistical analysis was performed using XLSTAT software.
RESULTS:
We identified 194 cases, and these were divided into 3 groups based on the surgical approach: SPAIRE (n = 43), lateral (n = 97), and posterior (n = 54). Groups had similar demographics and a minimum 3-month follow-up after surgery. There were no dislocations in the SPAIRE group, whereas the dislocation rate for the other 2 groups was 2.5% in the lateral and 9.1% in the posterior groups at 6 months post-surgery. There was an earlier return to mobility in the SPAIRE (1.4 day) compared to the 2 other groups ( 2 days and 2.6 days). Average surgical times were very similar among all 3 groups (74 min vs. 79 min vs. 71 min).
CONCLUSION
The SPAIRE approach seems to be safe and provides a low risk of dislocation and good post-operative function for patients undergoing hip hemiarthroplasties.
Humans
;
Hemiarthroplasty/methods*
;
Retrospective Studies
;
Female
;
Male
;
Aged
;
United Kingdom
;
Femoral Neck Fractures/surgery*
;
Middle Aged
;
Treatment Outcome
;
Aged, 80 and over
;
Arthroplasty, Replacement, Hip/methods*
;
Trauma Centers
;
Hip Dislocation/prevention & control*
;
Postoperative Complications/prevention & control*
7.Risk factors of perioperative deep venous thrombosis of lower extremities in elderly patients with femoral neck fracture.
Yonggang WANG ; Kai FU ; Wei ZHENG ; Qianying CAI ; Shengbao CHEN ; Changqing ZHANG ; Xianyou ZHENG
Chinese Journal of Reparative and Reconstructive Surgery 2024;38(11):1336-1339
OBJECTIVE:
To investigate the incidence of perioperative deep venous thrombosis (DVT) of lower extremities and its risk factors in elderly patients with femoral neck fracture.
METHODS:
The clinical data of 4 109 elderly patients with femoral neck fracture admitted between August 2012 and November 2020 and met the selection criteria were retrospectively analyzed. Among them, there were 1 137 males and 2 972 females; their ages ranged from 65 to 101 years, with an average of 77.0 years. The time from fracture to admission ranged from 1 to 360 hours, with an average of 35.2 hours. There were 1 858 cases of hemiarthroplasty, 1 617 cases of total hip arthroplasty, and 634 cases of internal fixation surgery. The preoperative age-adjusted Charlson comorbidity index (aCCI) was 4 (3, 5). Perioperative DVT occurred in 857 cases (20.9%). Univariate analysis was performed on age, gender, body mass index, fracture side, time from fracture to admission, operation type, anesthesia type, blood transfusion, blood pressure after admission, and preoperative aCCI in patients with and without perioperative DVT, and logistic regression analysis was used to screen the risk factors of perioperative DVT in elderly patients with femoral neck fracture.
RESULTS:
Univariate analysis showed that there were significant differences in age, gender, time from fracture to admission, operation type, and preoperative aCCI between the two groups ( P<0.05). Further logistic regression analysis showed that age>75 years, female patients, time from fracture to admission>24 hours, and preoperative aCCI>5 were risk factors for perioperative DVT ( P<0.05).
CONCLUSION
Elderly patients with femoral neck fracture have a higher incidence of perioperative DVT. The advanced aged and female patients, patients with longer fracture time and more comorbidities need to pay special attention to the prevention of perioperative DVT to minimize the occurrence of DVT during femoral neck fractures.
Humans
;
Femoral Neck Fractures/complications*
;
Female
;
Male
;
Aged
;
Venous Thrombosis/epidemiology*
;
Risk Factors
;
Aged, 80 and over
;
Retrospective Studies
;
Lower Extremity/blood supply*
;
Arthroplasty, Replacement, Hip/adverse effects*
;
Incidence
;
Fracture Fixation, Internal/methods*
;
Postoperative Complications/etiology*
;
Perioperative Period
;
Logistic Models
;
Hemiarthroplasty/adverse effects*
8.Relationship between cortical fragments and avascular necrosis of femoral head in young adult femoral neck fractures based on CT imaging.
Mang-Mang CHEN ; Xiao-Sheng CAI ; Yang-Xun LYU ; Sheng-Lei LIN ; Li-Peng HUANG ; Zhou LIN
China Journal of Orthopaedics and Traumatology 2024;37(11):1096-1100
OBJECTIVE:
To explore the effect of femoral neck cortical fragments and surfacial area on avascular necrosis(AVN) after internal fixation of femoral neck fractures based on CT imaging in young adult.
METHODS:
From January 2011 to January 2021, 218 young and middle-aged patients with femoral neck fractures were reverse triangle fixed with three cannulated lag screws, including 104 males and 114 females;aged 19 to 60 years old with a mean of (48.22±10.58) years old. The preoperative waiting time≤48 h was 155 cases, and the preoperative waiting time> 48 h was 63 cases; 68 cases were comminuted cortex of the femoral neck, 32 of them with superficial area of the comminuted cortex>25 mm2. All patients were followed up for at least 2 years, the age, gender, injury side, body mass index, injury mechanism, preoperative waiting time, operation time, Garden classification, whether femoral neck cortex fracture and size by CT analysis and complications were analyzed the correlation to the definite occurrence of AVN. The AVN group and the non-AVN group were divided according to the final efficacy results.Univariate analysis yielded significant independent variables, Multiple Logistic regression analysis was further performed to identify the independent risk factors for AVN.
RESULTS:
By univariate analysis, the AVN and non-AVN groups were significant in injury mechanism(χ2=18.552, P=0.000), preoperative waiting time( χ2=2.065, P=0.033), Garden classification (χ2=12.598, P=0.006), comminuted cortex (χ2=16.357, P=0.000), and the superficial area of the comminuted cortex(χ2=23.371, 0.000, P=0.000). Multiple Logistic regression indicated injury mechanism high energy injury[Exp(B)=3.487, 95%CI(1.583, 10.464), P=0.002], comminuted cortex of the femoral neck[Exp(B)=2.494, 95%CI(1.315, 10.861), P=0.002];the superficial area of the comminuted cortex>25 mm2[Exp(B)=22.161, 95%CI(3.922, 1242.828), P=0.001] were independent risk factors for AVN after internal fixation of femoral neck fractures.
CONCLUSION
High energy injury mechanism, with comminuted cortex of the femoral neck and the superficial area of the comminuted cortex> 25 mm2 were independent risk factors for AVN.The larger the superficial area of the cortex fragment may suggest more complicated injury mechanism and worse outcome.
Humans
;
Male
;
Female
;
Adult
;
Femoral Neck Fractures/diagnostic imaging*
;
Tomography, X-Ray Computed
;
Middle Aged
;
Femur Head Necrosis/etiology*
;
Young Adult
;
Fracture Fixation, Internal/methods*
10.Surgical treatment for ipsilateral femoral neck and shaft fracture.
Bang DOU ; Wen-Qian MA ; Tao QIN ; Wei ZHU ; Ya-Hui DAI ; Xiao-Bin XU
China Journal of Orthopaedics and Traumatology 2023;36(3):203-208
OBJECTIVE:
To retrospectively analyze efficacy of single structure internal fixation and double structure internal fixation in the treatment of ipsilateral femoral shaft and neck fracture, and analyze their indications.
METHODS:
From June 2015 to December 2020, 21 patients with ipsilateral femoral shaft and femoral neck fracture were treated, including 14 males and 7 females, aged 23 to 69 years old with an average of(38.1±12.9) years old. According to different femoral shaft fracture sites, some patients were fixed with cephalomedullary implant for both femoral neck and the femoral shaft(single structure, InterTan or PFNA Ⅱ), some patients were fixed with cannulated screws for the femoral neck and a retrograde locking nail for the femoral shaft (dual structure), and postoperative function and complications were recorded during follow-up. In 10 cases of single-structure fixation, the femoral necks were all basicervical fractures, and the femoral shaft fractures were located in the proximal isthmus;11 cases were double-structure fixation, 9 cases in 11 were basal type of femoral neck, 2 cases in 11 were neck type, and the femoral shaft fractures were located in the isthmus and the distal isthmus.
RESULTS:
All patients were followed up for 12 to 27 months. No femoral head necrosis, deformity, delay or nonunion occurred in the patients with single-structure fixation, and no delayed union or nonunion occurred in femoral shaft fractures;At the final follow-up, Harris score of patients with single-structure fixation was 91.8±4.1, with 8 cases were excellent and 2 cases were good. The fractures of patients with dual-structure fixation achieved good union without femoral head necrosis, except 1 case of femoral shaft fracture had delayed union;At the final follow-up, Harris score of patients with dual-structure fixation was 92.4±5.9, 7 cases were excellent, 3 cases were good, and 1 case was fair.
CONCLUSION
Good reduction and fixation is the key to the treatment of such fractures. Both the single-structure fixation and the dual-structure fixation are good methods, and it should be selected according to the locations of femoral shaft and femoral neck fractures. Single-structure fixation is a good choice for femoral shaft fractures located at the proximal isthmus and basal femoral neck fractures. For isthmus and distal femoral shaft fractures combined with ipsilateral femoral neck fractures, dual-structure fixation is recommended.
Male
;
Female
;
Humans
;
Young Adult
;
Adult
;
Middle Aged
;
Aged
;
Femur Neck
;
Retrospective Studies
;
Femoral Neck Fractures/complications*
;
Femoral Fractures/complications*
;
Fracture Fixation, Internal/methods*
;
Femoral Fractures, Distal
;
Treatment Outcome
;
Fracture Fixation, Intramedullary/methods*

Result Analysis
Print
Save
E-mail