1.Study on assessment methods for acetabular cup size in total hip arthroplasty.
Jinzi WANG ; Wenju CHANG ; Pei ZHANG ; Xiang LI ; Yong ZHANG ; Shuoshuo ZHANG ; Hai DING
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(2):163-167
OBJECTIVE:
To evaluate precise assessment methods for predicting the optimal acetabular cup size in total hip arthroplasty (THA).
METHODS:
A clinical data of 73 patients (80 hips) who underwent primary THA between December 2022 and July 2024 and met the inclusion criteria was analyzed. There were 39 males and 34 females with an average age of 66.3 years (range, 56-78 years). Among them, 66 cases were unilateral THA and 7 were bilateral THAs. There were 29 patients (34 hips) of osteoarthritis, 35 patients (35 hips) of femoral neck fractures, and 9 patients (11 hips) of osteonecrosis of the femoral head. Based on anteroposterior pelvic X-ray films, three methods were employed to predict acetabular cup size, including preoperative template planning, radiographic femoral head diameter (FHD) measurement, and intraoperative FHD measurement. The predicted acetabular cup sizes from these methods were compared with the actual implanted sizes.
RESULTS:
The predicted acetabular cup sizes using the preoperative template planning, radiographic FHD measurement, and intraoperative FHD measurement were (51.25±2.81), (49.72±3.11), and (49.90±2.74) mm, respectively, compared to the actual implanted cup size of (50.57±2.74) mm, with no significant difference ( P>0.05). Regarding agreement with the actual implanted cup size, the preoperative template planning achieved exact matches in 35 hips (43.75%), one-size deviation in 41 hips (51.25%), and two-size deviations in 4 hips (5%); the radiographic FHD measurement achieved exact matches in 12 hips (15%), one-size deviation in 57 hips (71.25%), and two-size deviations in 11 hips (13.75%); and the intraoperative FHD measurement achieved exact matches in 26 hips (32.5%), one-size deviation in 52 hips (65%), and two-size deviations in 2 hips (2.5%). There were significant differences in agreement distributions between the three methods and the actual implanted cup sizes ( H=18.579, P<0.001).
CONCLUSION
The intraoperative FHD measurement, as a simple, cost-effective, and accurate method, effectively guides acetabular cup selection, reduces the risk of prosthesis wear, enhances postoperative joint stability.
Humans
;
Arthroplasty, Replacement, Hip/instrumentation*
;
Male
;
Female
;
Middle Aged
;
Acetabulum/diagnostic imaging*
;
Aged
;
Hip Prosthesis
;
Prosthesis Design
;
Femur Head/surgery*
;
Osteoarthritis, Hip/surgery*
;
Radiography
;
Femoral Neck Fractures/surgery*
;
Femur Head Necrosis/surgery*
2.Effectiveness of guide plate with mortise-tenon joint structure combined with off-axis fixation in treatment of Pauwels type Ⅲ femoral neck fractures.
Xuanye ZHU ; Lijuan CUI ; Leilei ZHANG ; Yudong JIA ; Yingjie ZHU ; Youwen LIU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(3):284-289
OBJECTIVE:
To investigate the effectiveness of using 3 hollow compression screws combined with 1 screw off-axis fixation under the guidance of three-dimensional (3D) printed guide plate with mortise-tenon joint structure (mortise-tenon joint plate) for the treatment of Pauwels type Ⅲ femoral neck fractures.
METHODS:
A clinical data of 78 patients with Pauwels type Ⅲ femoral neck fractures, who were admitted between August 2022 and August 2023 and met the selection criteria, was retrospectively analyzed. The operations were assisted with mortise-tenon joint plates in 26 cases (mortise-tenon joint plate group) and traditional guide plates in 28 cases (traditional plate group), and without guide plates in 24 cases (control group). There was no significant difference in the baseline data of gender, age, body mass index, cause of injury, and fracture side between groups ( P>0.05). The operation time, intraoperative blood loss, frequency of intraoperative fluoroscopy, incision length, incidence of postoperative deep vein thrombosis of lower extremity, pain visual analogue scale (VAS) score at 1 week after operation, and Harris score of hip joint at 3 months after operation were recorded and compared. X-ray re-examination was taken to check the quality of fracture reduction, fracture healing, and the shortening length of the femoral neck at 3 months after operation, and the incidences of internal fixation failure and osteonecrosis of the femoral head during operation.
RESULTS:
Compared with the control group, the operation time, intraoperative blood loss, and frequency of intraoperative fluoroscopy reduced in the two plate groups, and the quality of fracture reduction was better, but the incision was longer, and the differences were significant ( P<0.05). The operation time and intraoperative blood loss were significantly higher in the traditional plate group than in the mortise-tenon joint plate group ( P<0.05), the incision was significantly longer ( P<0.05); and the difference in fracture reduction quality and the frequency of intraoperative fluoroscopy was not significant between two plate groups ( P>0.05). There was 1 case of deep vein thrombosis of lower extremity in the traditional plate group and 1 case in the control group, while there was no thrombosis in the mortise-tenon joint plate group. There was no significant difference in the incidence between groups ( P>0.05). All patients were followed up 12-15 months (mean, 13 months). There was no significant difference in VAS score at 1 week and Harris score at 3 months between groups ( P>0.05). Compared with the control group, the fracture healing time and the length of femoral neck shortening at 3 months after operation were significantly shorter in the two plate groups ( P<0.05). There was no significant difference between the two plate groups ( P>0.05). There was no significant difference in the incidences of non-union fractures, osteonecrosis of the femoral head, or internal fixation failure between groups ( P>0.05).
CONCLUSION
For Pauwels type Ⅲ femoral neck fractures, the use of 3D printed guide plate assisted reduction and fixation can shorten the fracture healing time, reduce the incidence of postoperative complications, and be more conducive to the early functional exercise of the affected limb. Compared with the traditional guide plate, the mortise-tenon joint plate can reduce the intraoperative bleeding and shorten the operation time.
Humans
;
Femoral Neck Fractures/diagnostic imaging*
;
Bone Plates
;
Fracture Fixation, Internal/instrumentation*
;
Male
;
Female
;
Retrospective Studies
;
Middle Aged
;
Bone Screws
;
Adult
;
Aged
;
Treatment Outcome
;
Printing, Three-Dimensional
;
Operative Time
3.Finite element analysis of adding one transverse screw for Pauwels type Ⅲ femoral neck fractures.
Luyao MA ; Xueao SUN ; Qingjun TAN ; Yanping LAN ; Xiaohu WANG ; Yunsheng YIN ; Jinhui MA
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(5):584-591
OBJECTIVE:
To investigate whether adding 1 transverse screw (TS) to the triangular parallel cannulated screw (TPCS) fixation has a mechanical stability advantage for Pauwels type Ⅲ femoral neck fractures by conducting finite element analysis on four internal fixation methods.
METHODS:
Based on CT data of a healthy adult male volunteer's femur, three Pauwels type Ⅲ femoral neck fracture models (Pauwels angle 70°, Pauwels angle 80°, and Pauwels angle 70° combined with bone defect) were constructed using Mimics 21.0 software and SolidWorks 2017 software. Four different internal fixation models were built at the same time, including TPCS, TPCS+TS, three cross screws (TCS), and TPCS+medial buttress plate (MBP). The mechanical stability of different models under the same load was compared by finite element analysis.
RESULTS:
The femoral model established in this study exhibited a maximum stress of 28.62 MPa, with relatively higher stress concentrated in the femoral neck. These findings were comparable to previous studies, indicating that the constructed femoral finite element model was correct. The maximum stress of internal fixation in finite element analysis showed that TCS was the lowest and TPCS+MBP was the highest in Pauwels angle 70° and 80° models, while TPCS+TS was the lowest and TCS was the highest in Pauwels angle 70° combined with bone defect model. The maximum displacement of internal fixation in each fracture model was located at the top of the femoral head, with TCS having the highest maximum displacement of the femur. The maximum stress of fracture surface in finite element analysis showed that TCS was the lowest and TPCS was the highest in the Pauwels angle 70° model, while TPCS+MBP was the lowest and TPCS/TCS were the highest in the Pauwels angle 80° model and the Pauwels angle 70° combined with bone defect model, respectively. The maximum displacement of fracture surfece analysis showed that TPCS+MBP was the lowest and TCS was the highest in Pauwels angle 70° and 80° models, while TPCS+TS was the lowest and TCS was the highest in Pauwels angle 70° combined with bone defect model.
CONCLUSION
For Pauwels type Ⅲ femoral neck fractures, the biomechanical stability of TPCS+TS was superior to that of TPCS alone and TCS, but it has not yet reached the level of TPCS+MBP.
Finite Element Analysis
;
Humans
;
Femoral Neck Fractures/diagnostic imaging*
;
Bone Screws
;
Fracture Fixation, Internal/instrumentation*
;
Male
;
Bone Plates
;
Stress, Mechanical
;
Biomechanical Phenomena
;
Tomography, X-Ray Computed
;
Adult
;
Femur Neck/surgery*
4.Analysis of effectiveness of Holosight robot navigation-assisted percutaneous cannulated screw fixation in treatment of femoral neck fractures.
Weizhen XU ; Zhenqi DING ; Hui LIU ; Jinhui ZHANG ; Yuanfei XIONG ; Jin WU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(6):673-679
OBJECTIVE:
To investigate the effectiveness of Holosight robotic navigation-assisted percutaneous cannulated screw fixation for femoral neck fractures.
METHODS:
A retrospective analysis was conducted on 65 patients with femoral neck fractures treated with cannulated screw fixation between January 2022 and February 2024. Among them, 31 patients underwent robotic navigation-assisted screw placement (navigation group), while 34 underwent conventional freehand percutaneous screw fixation (freehand group). Baseline characteristics, including age, gender, fracture side, injury mechanism, Garden classification, Pauwels classification, and time from injury to operation, showed no significant differences between the two groups ( P>0.05). The operation time, intraoperative blood loss, fluoroscopy frequency, fracture healing time, and complications were recorded and compared, and hip function was evaluated by Harris score at last follow-up. Postoperative anteroposterior and lateral hip X-ray films were taken to assess screw distribution accuracy, including deviation from the femoral neck axis, inter-screw parallelism, and distance from screws to the femoral neck cortex.
RESULTS:
No significant difference was observed in operation time between the two groups ( P>0.05). However, the navigation group demonstrated superior outcomes in intraoperative blood loss, fluoroscopy frequency, deviation from the femoral neck axis, inter-screw parallelism, and distance from screws to the femoral neck cortex ( P<0.05). No incision infections or deep vein thrombosis occurred. All patients were followed up 12-18 months (mean, 16 months). In the freehand group, 1 case suffered from cannulated screw dislodgement and nonunion secondary to osteonecrosis of femoral head at 1 year after operation, 1 case suffered from screw penetration secondary to osteonecrosis of femoral head at 5 months after operation; and 1 case suffered from nonunion secondary to osteonecrosis of femoral head at 6 months after operation in the navigation group. All the 3 patients underwent internal fixators removal and total hip arthroplasty. There was no significant difference in the incidence of complications between the two groups ( P>0.05). The fracture healing time and hip Harris score at last follow-up in the navigation group were significantly better than those in the freehand group ( P<0.05).
CONCLUSION
Compared to freehand percutaneous screw fixation, Holosight robotic navigation-assisted cannulated screw fixation for femoral neck fractures achieves higher precision, reduced intraoperative radiation exposure, smaller incisions, and superior postoperative hip function recovery.
Humans
;
Femoral Neck Fractures/diagnostic imaging*
;
Bone Screws
;
Fracture Fixation, Internal/instrumentation*
;
Male
;
Female
;
Retrospective Studies
;
Robotic Surgical Procedures/methods*
;
Middle Aged
;
Aged
;
Adult
;
Treatment Outcome
;
Operative Time
;
Fracture Healing
;
Surgery, Computer-Assisted/methods*
;
Fluoroscopy
5.Relationship between cortical fragments and avascular necrosis of femoral head in young adult femoral neck fractures based on CT imaging.
Mang-Mang CHEN ; Xiao-Sheng CAI ; Yang-Xun LYU ; Sheng-Lei LIN ; Li-Peng HUANG ; Zhou LIN
China Journal of Orthopaedics and Traumatology 2024;37(11):1096-1100
OBJECTIVE:
To explore the effect of femoral neck cortical fragments and surfacial area on avascular necrosis(AVN) after internal fixation of femoral neck fractures based on CT imaging in young adult.
METHODS:
From January 2011 to January 2021, 218 young and middle-aged patients with femoral neck fractures were reverse triangle fixed with three cannulated lag screws, including 104 males and 114 females;aged 19 to 60 years old with a mean of (48.22±10.58) years old. The preoperative waiting time≤48 h was 155 cases, and the preoperative waiting time> 48 h was 63 cases; 68 cases were comminuted cortex of the femoral neck, 32 of them with superficial area of the comminuted cortex>25 mm2. All patients were followed up for at least 2 years, the age, gender, injury side, body mass index, injury mechanism, preoperative waiting time, operation time, Garden classification, whether femoral neck cortex fracture and size by CT analysis and complications were analyzed the correlation to the definite occurrence of AVN. The AVN group and the non-AVN group were divided according to the final efficacy results.Univariate analysis yielded significant independent variables, Multiple Logistic regression analysis was further performed to identify the independent risk factors for AVN.
RESULTS:
By univariate analysis, the AVN and non-AVN groups were significant in injury mechanism(χ2=18.552, P=0.000), preoperative waiting time( χ2=2.065, P=0.033), Garden classification (χ2=12.598, P=0.006), comminuted cortex (χ2=16.357, P=0.000), and the superficial area of the comminuted cortex(χ2=23.371, 0.000, P=0.000). Multiple Logistic regression indicated injury mechanism high energy injury[Exp(B)=3.487, 95%CI(1.583, 10.464), P=0.002], comminuted cortex of the femoral neck[Exp(B)=2.494, 95%CI(1.315, 10.861), P=0.002];the superficial area of the comminuted cortex>25 mm2[Exp(B)=22.161, 95%CI(3.922, 1242.828), P=0.001] were independent risk factors for AVN after internal fixation of femoral neck fractures.
CONCLUSION
High energy injury mechanism, with comminuted cortex of the femoral neck and the superficial area of the comminuted cortex> 25 mm2 were independent risk factors for AVN.The larger the superficial area of the cortex fragment may suggest more complicated injury mechanism and worse outcome.
Humans
;
Male
;
Female
;
Adult
;
Femoral Neck Fractures/diagnostic imaging*
;
Tomography, X-Ray Computed
;
Middle Aged
;
Femur Head Necrosis/etiology*
;
Young Adult
;
Fracture Fixation, Internal/methods*
6.Comparative study of multiple cancellous screws versus sliding hip screws in femoral neck fractures of young adults.
Mayank GUPTA ; R-K ARYA ; Satish KUMAR ; Vijay-Kumar JAIN ; Skand SINHA ; Ananta-Kumar NAIK
Chinese Journal of Traumatology 2016;19(4):209-212
PURPOSEBoth cannulated cancellous screw (CCS) and sliding hip screw (SHS) are used in femoral neck fracture fixations, but which is superior is yet to be determined. This study was aimed to compare the clinicoradiological outcome of femoral neck fracture treated with SHS or CCS in young adults.
METHODSAdults (16e60 years) with femoral neck fracture were divided into Group 1 fixed with SHS and Group 2 fixed with three CCS after closed reduction. Pain relief, functional recovery and postoperative radiographs at 6 weeks, 3 months, 6 months and then yearly for upto 4 years were analyzed.
RESULTSGroup 1 (n=40) achieved radiological union at mean of 7.6 months, with the union rate of 87.5% (n=35), avascular necrosis (AVN) rate of 7.5% (n=3) and mean Harris Hip Score (HHS) of 86.15 at the end of 4 years. In Group 2 (n=45) these parameters were union at 7.1 months, union rate of 82.22% (n=37), AVN rate of 6.67% (n=3) and HHS of 88.65. Comparative results were statistically insignificant.
CONCLUSIONThere is no significant difference in clinicoradiological outcome between the two implants.
Adolescent ; Adult ; Bone Screws ; Female ; Femoral Neck Fractures ; diagnostic imaging ; physiopathology ; surgery ; Humans ; Male ; Middle Aged ; Osteonecrosis ; epidemiology ; Postoperative Complications ; epidemiology ; Prospective Studies ; Recovery of Function ; Young Adult
7.Malunion in displaced intracapsular fracture of femoral neck: A rare case.
Nikhil VERMA ; M P SINGH ; Rehan Ul HAQ ; Aditya N AGGARWAL ; Anuj JAIN
Chinese Journal of Traumatology 2015;18(5):307-310
Intracapsular fracture of femoral neck is treated by anatomical reduction (preferably closed) and cannulated cancellous lag screw fixation. Malunion of these fractures have been described in the coronal plane (coxa valga or coxa vara). We reported a case of young adult patient with displaced intracapsular fracture of femoral neck that had malunited in sagittal plane with callus formation with excellent functional outcome. The radiographs revealed intracapsular fracture of femoral neck right side (Garden type 4 and Pauwel type 3). The patient was operated and closed reduction and internal fixation with three cannulated cancellous screws was performed. The postoperative radiograph revealed a loss of reduction in the lateral view. Due to this technical error, the patient was counselled for revision fixation for which he refused. At 9 months we observed union of the fracture in the displaced position by callus formation. Harris hip score at 2 years was 96 that indicate excellent functional outcome and the radiographs did not reveal any evidence of avascular necrosis of femoral head. We advised revision surgery to our patient as he had increased chances of implant failure and nonunion. However he refused the revision surgery and was continued with the suboptimal reduction. However, the fracture united and that too with callus formation, which is not a described phenomenon in neck of femur fracture.
Adult
;
Bone Screws
;
Femoral Neck Fractures
;
diagnostic imaging
;
physiopathology
;
surgery
;
Fracture Fixation, Internal
;
Humans
;
Male
8.Simultaneous bilateral fractures of the femoral neck caused by high energy: A case report and literature review.
You-Shui GAO ; Zhen-Hong ZHU ; Chang-Qing ZHANG
Chinese Journal of Traumatology 2015;18(5):304-306
Simultaneous bilateral fractures of the femoral neck are rare injuries, which are reportedly induced by low-speed energy with predisposing factors including systemic diseases, medications and eclamptic seizures. Those caused by high energy are even rarer. High energy-induced bilateral fractures of the femoral neck conceive of high incidence of mortality and present great challenges in the early management. We report one case of a 52-year-old man with simultaneous bilateral fractures of the femoral neck which resulted from a motor pedestrian accident. One-stage closed reduction and internal fixation was done following the emergent resuscitation and neurosurgical management for concomitant brain injuries. The fractures united. There was no pain in the hips, and they had a normal range of motion. The treatment protocol, mechanism of the injury and possible postoperative complications were discussed to expand a comprehensive understanding about these infrequent types of fractures.
Femoral Neck Fractures
;
diagnostic imaging
;
etiology
;
surgery
;
Fracture Fixation, Internal
;
adverse effects
;
Humans
;
Male
;
Middle Aged
;
Postoperative Complications
;
etiology
;
Tomography, X-Ray Computed
9.Management of neglected femoral neck fracture in above knee amputated limb: A case report.
Umesh MEENA ; Ramesh MEENA ; Balaji S ; Sahil GABA
Chinese Journal of Traumatology 2015;18(6):370-372
The treatment of an above knee amputee who has sustained a fracture of the femoral neck is a chal- lenging situation for both the orthopedic surgeon and the rehabilitation team. These fractures may be managed acutely either by reduction and internal fixation or by endoprosthetic replacement based on the same criteria as in any other patient with otherwise intact limbs.We present a neglected case treated successfully with valgus osteotomy. We conclude that these fractures should be treated with the same urgency and expertise as similar fractures in non-amputees as long-term survival and good quality of life can be expected.
Adult
;
Amputation
;
Femoral Neck Fractures
;
diagnostic imaging
;
surgery
;
Fracture Fixation, Internal
;
methods
;
Humans
;
Leg
;
surgery
;
Male

Result Analysis
Print
Save
E-mail