1.An experimental study on distal locking of femoral intramedullary nail assisted by an intelligent orthopedic robot.
Kun WANG ; Cui XU ; Zhonghe WANG ; Junsong WANG ; Shaobo NIE ; Yanpeng ZHAO ; Wei ZHANG ; Ming HAO
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(2):129-133
OBJECTIVE:
To explore the advantages and effectiveness of the independently developed intelligent orthopedic robot-assisted distal locking of femoral intramedullary nails.
METHODS:
Thirty-two adult cadaveric femur specimens were randomly divided into two groups, with 16 specimens in each group. The experimental group used the intelligent orthopedic robot to assist in the distal locking of femoral intramedullary nail holes, while the control group used the traditional method of manual locking under X-ray fluoroscopy. The locking time, fluoroscopy times, and the success rate of first locking were recorded and compared between the two groups.
RESULTS:
The locking time of the experimental group was (273.94±38.67) seconds, which was shorter than that of the control group [(378.38±152.72) seconds], and number of fluoroscopies was (4.56±0.81) times, which was less than that of the control group [(8.00±3.98) times]. The differences were significant [ MD=73.054 (-37.187, 85.813), P=0.049; MD=1.969 (-1.437, 2.563), P=0.002]. The first locking success rate of the experimental group was 100% (16/16), which was significantly higher than that of the control group (68.75%, 11/16) ( P=0.043).
CONCLUSION
The efficiency of distal locking of femoral intramedullary nails assisted by the intelligent orthopedic robot is significantly higher than that of the traditional manual locking method under fluoroscopy, as it can markedly reduce the time required for distal locking of femoral intramedullary nails, decrease intraoperative radiation exposure, and increase the success rate of locking.
Humans
;
Fracture Fixation, Intramedullary/instrumentation*
;
Bone Nails
;
Fluoroscopy
;
Femur/diagnostic imaging*
;
Femoral Fractures/surgery*
;
Robotic Surgical Procedures/instrumentation*
;
Cadaver
;
Adult
;
Robotics
;
Male
2.Study on assessment methods for acetabular cup size in total hip arthroplasty.
Jinzi WANG ; Wenju CHANG ; Pei ZHANG ; Xiang LI ; Yong ZHANG ; Shuoshuo ZHANG ; Hai DING
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(2):163-167
OBJECTIVE:
To evaluate precise assessment methods for predicting the optimal acetabular cup size in total hip arthroplasty (THA).
METHODS:
A clinical data of 73 patients (80 hips) who underwent primary THA between December 2022 and July 2024 and met the inclusion criteria was analyzed. There were 39 males and 34 females with an average age of 66.3 years (range, 56-78 years). Among them, 66 cases were unilateral THA and 7 were bilateral THAs. There were 29 patients (34 hips) of osteoarthritis, 35 patients (35 hips) of femoral neck fractures, and 9 patients (11 hips) of osteonecrosis of the femoral head. Based on anteroposterior pelvic X-ray films, three methods were employed to predict acetabular cup size, including preoperative template planning, radiographic femoral head diameter (FHD) measurement, and intraoperative FHD measurement. The predicted acetabular cup sizes from these methods were compared with the actual implanted sizes.
RESULTS:
The predicted acetabular cup sizes using the preoperative template planning, radiographic FHD measurement, and intraoperative FHD measurement were (51.25±2.81), (49.72±3.11), and (49.90±2.74) mm, respectively, compared to the actual implanted cup size of (50.57±2.74) mm, with no significant difference ( P>0.05). Regarding agreement with the actual implanted cup size, the preoperative template planning achieved exact matches in 35 hips (43.75%), one-size deviation in 41 hips (51.25%), and two-size deviations in 4 hips (5%); the radiographic FHD measurement achieved exact matches in 12 hips (15%), one-size deviation in 57 hips (71.25%), and two-size deviations in 11 hips (13.75%); and the intraoperative FHD measurement achieved exact matches in 26 hips (32.5%), one-size deviation in 52 hips (65%), and two-size deviations in 2 hips (2.5%). There were significant differences in agreement distributions between the three methods and the actual implanted cup sizes ( H=18.579, P<0.001).
CONCLUSION
The intraoperative FHD measurement, as a simple, cost-effective, and accurate method, effectively guides acetabular cup selection, reduces the risk of prosthesis wear, enhances postoperative joint stability.
Humans
;
Arthroplasty, Replacement, Hip/instrumentation*
;
Male
;
Female
;
Middle Aged
;
Acetabulum/diagnostic imaging*
;
Aged
;
Hip Prosthesis
;
Prosthesis Design
;
Femur Head/surgery*
;
Osteoarthritis, Hip/surgery*
;
Radiography
;
Femoral Neck Fractures/surgery*
;
Femur Head Necrosis/surgery*
3.Effectiveness of guide plate with mortise-tenon joint structure combined with off-axis fixation in treatment of Pauwels type Ⅲ femoral neck fractures.
Xuanye ZHU ; Lijuan CUI ; Leilei ZHANG ; Yudong JIA ; Yingjie ZHU ; Youwen LIU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(3):284-289
OBJECTIVE:
To investigate the effectiveness of using 3 hollow compression screws combined with 1 screw off-axis fixation under the guidance of three-dimensional (3D) printed guide plate with mortise-tenon joint structure (mortise-tenon joint plate) for the treatment of Pauwels type Ⅲ femoral neck fractures.
METHODS:
A clinical data of 78 patients with Pauwels type Ⅲ femoral neck fractures, who were admitted between August 2022 and August 2023 and met the selection criteria, was retrospectively analyzed. The operations were assisted with mortise-tenon joint plates in 26 cases (mortise-tenon joint plate group) and traditional guide plates in 28 cases (traditional plate group), and without guide plates in 24 cases (control group). There was no significant difference in the baseline data of gender, age, body mass index, cause of injury, and fracture side between groups ( P>0.05). The operation time, intraoperative blood loss, frequency of intraoperative fluoroscopy, incision length, incidence of postoperative deep vein thrombosis of lower extremity, pain visual analogue scale (VAS) score at 1 week after operation, and Harris score of hip joint at 3 months after operation were recorded and compared. X-ray re-examination was taken to check the quality of fracture reduction, fracture healing, and the shortening length of the femoral neck at 3 months after operation, and the incidences of internal fixation failure and osteonecrosis of the femoral head during operation.
RESULTS:
Compared with the control group, the operation time, intraoperative blood loss, and frequency of intraoperative fluoroscopy reduced in the two plate groups, and the quality of fracture reduction was better, but the incision was longer, and the differences were significant ( P<0.05). The operation time and intraoperative blood loss were significantly higher in the traditional plate group than in the mortise-tenon joint plate group ( P<0.05), the incision was significantly longer ( P<0.05); and the difference in fracture reduction quality and the frequency of intraoperative fluoroscopy was not significant between two plate groups ( P>0.05). There was 1 case of deep vein thrombosis of lower extremity in the traditional plate group and 1 case in the control group, while there was no thrombosis in the mortise-tenon joint plate group. There was no significant difference in the incidence between groups ( P>0.05). All patients were followed up 12-15 months (mean, 13 months). There was no significant difference in VAS score at 1 week and Harris score at 3 months between groups ( P>0.05). Compared with the control group, the fracture healing time and the length of femoral neck shortening at 3 months after operation were significantly shorter in the two plate groups ( P<0.05). There was no significant difference between the two plate groups ( P>0.05). There was no significant difference in the incidences of non-union fractures, osteonecrosis of the femoral head, or internal fixation failure between groups ( P>0.05).
CONCLUSION
For Pauwels type Ⅲ femoral neck fractures, the use of 3D printed guide plate assisted reduction and fixation can shorten the fracture healing time, reduce the incidence of postoperative complications, and be more conducive to the early functional exercise of the affected limb. Compared with the traditional guide plate, the mortise-tenon joint plate can reduce the intraoperative bleeding and shorten the operation time.
Humans
;
Femoral Neck Fractures/diagnostic imaging*
;
Bone Plates
;
Fracture Fixation, Internal/instrumentation*
;
Male
;
Female
;
Retrospective Studies
;
Middle Aged
;
Bone Screws
;
Adult
;
Aged
;
Treatment Outcome
;
Printing, Three-Dimensional
;
Operative Time
4.Treatment of irreducible intertrochanteric femoral fracture in elderly with proximal femoral nail antirotation combined with minimally invasive clamp reduction technique by Kocher pincers.
Hongwei TANG ; Yong YIN ; Yinhua MA
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(5):536-541
OBJECTIVE:
To explore the effectiveness of proximal femoral nail antirotation (PFNA) combined with minimally invasive clamp reduction technique by Kocher pincers in the treatment of irreducible intertrochanteric femoral fracture in the elderly.
METHODS:
The clinical data of 35 elderly patients with irreducible intertrochanteric femoral fractures who were treated with PFNA combined with minimally invasive clamp reduction technique by Kocher pincers between January 2016 and December 2022 were retrospectively analysed. There were 16 males and 19 females, aged from 63 to 95 years (mean, 75.2 years). The causes of injury included traffic accident in 3 cases and falling in 32 cases. The time from injury to operation was 2-11 days (mean, 3.6 days). According to AO/Orthopaedic Trauma Association (AO/OTA) classification system for intertrochanteric fractures, there were 14 cases of type A1, 18 cases of type A2, and 3 cases of type A3. According to the displacement of fracture by intraoperative fluoroscopy, there were 5 cases with only coronal displacement, 17 cases with only sagittal displacement, and 13 cases with both coronal and sagittal displacement. The operation time, intraoperative blood loss, rate of hemoglobin decline at 1 day after operation, length of hospital stay, and fracture healing time were recorded. The reduction quality of fracture during operation was evaluated according to reduction quality criteria proposed by Chang et al. The Harris scoring system was used to evaluate the hip joint function at last follow-up.
RESULTS:
The operation time was 45-105 minutes (mean, 54.4 minutes); the intraoperative blood loss was 80-300 mL (mean, 116.3 mL). The reduction quality of fracture during operation was good in 22 cases (62.9%) and acceptable in 13 cases (37.1%). The rate of hemoglobin decline at 1 day after operation ranged from 6.2% to 18.6% (mean, 10.2%); the length of hospital stay was 5-18 days (mean, 7.2 days). One case died of respiratory failure due to pulmonary infection, 2 cases were lost to follow-up, and the remaining 32 cases were followed up 6-24 months (mean, 10.6 months). All 32 patients achieved bony union and the healing time was 3-9 months (mean, 3.6 months). There was no complication such as incision infection, internal fixation failure, or coxa varus during follow-up. At last follow-up, the Harris score of hip joint was 67-96 (mean, 88.9); among them, 19 cases were excellent, 10 cases were good, 2 cases were fair, and 1 case was poor, with an excellent and good rate of 90.6%.
CONCLUSION
For the elderly patients with irreducible intertrochanteric femoral fracture, the application of PFNA combined with minimally invasive clamp reduction technique by Kocher pincers can achieve high-quality fracture reduction, which has the advantages of simple reduction operation, less trauma, and can avoid the radiation exposure of operators during maintenance reduction.
Humans
;
Male
;
Female
;
Aged
;
Minimally Invasive Surgical Procedures/methods*
;
Hip Fractures/diagnostic imaging*
;
Bone Nails
;
Aged, 80 and over
;
Retrospective Studies
;
Fracture Fixation, Intramedullary/instrumentation*
;
Middle Aged
;
Treatment Outcome
;
Fracture Fixation, Internal/instrumentation*
;
Fracture Healing
;
Femoral Fractures/surgery*
5.Finite element analysis of adding one transverse screw for Pauwels type Ⅲ femoral neck fractures.
Luyao MA ; Xueao SUN ; Qingjun TAN ; Yanping LAN ; Xiaohu WANG ; Yunsheng YIN ; Jinhui MA
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(5):584-591
OBJECTIVE:
To investigate whether adding 1 transverse screw (TS) to the triangular parallel cannulated screw (TPCS) fixation has a mechanical stability advantage for Pauwels type Ⅲ femoral neck fractures by conducting finite element analysis on four internal fixation methods.
METHODS:
Based on CT data of a healthy adult male volunteer's femur, three Pauwels type Ⅲ femoral neck fracture models (Pauwels angle 70°, Pauwels angle 80°, and Pauwels angle 70° combined with bone defect) were constructed using Mimics 21.0 software and SolidWorks 2017 software. Four different internal fixation models were built at the same time, including TPCS, TPCS+TS, three cross screws (TCS), and TPCS+medial buttress plate (MBP). The mechanical stability of different models under the same load was compared by finite element analysis.
RESULTS:
The femoral model established in this study exhibited a maximum stress of 28.62 MPa, with relatively higher stress concentrated in the femoral neck. These findings were comparable to previous studies, indicating that the constructed femoral finite element model was correct. The maximum stress of internal fixation in finite element analysis showed that TCS was the lowest and TPCS+MBP was the highest in Pauwels angle 70° and 80° models, while TPCS+TS was the lowest and TCS was the highest in Pauwels angle 70° combined with bone defect model. The maximum displacement of internal fixation in each fracture model was located at the top of the femoral head, with TCS having the highest maximum displacement of the femur. The maximum stress of fracture surface in finite element analysis showed that TCS was the lowest and TPCS was the highest in the Pauwels angle 70° model, while TPCS+MBP was the lowest and TPCS/TCS were the highest in the Pauwels angle 80° model and the Pauwels angle 70° combined with bone defect model, respectively. The maximum displacement of fracture surfece analysis showed that TPCS+MBP was the lowest and TCS was the highest in Pauwels angle 70° and 80° models, while TPCS+TS was the lowest and TCS was the highest in Pauwels angle 70° combined with bone defect model.
CONCLUSION
For Pauwels type Ⅲ femoral neck fractures, the biomechanical stability of TPCS+TS was superior to that of TPCS alone and TCS, but it has not yet reached the level of TPCS+MBP.
Finite Element Analysis
;
Humans
;
Femoral Neck Fractures/diagnostic imaging*
;
Bone Screws
;
Fracture Fixation, Internal/instrumentation*
;
Male
;
Bone Plates
;
Stress, Mechanical
;
Biomechanical Phenomena
;
Tomography, X-Ray Computed
;
Adult
;
Femur Neck/surgery*
6.Analysis of effectiveness of Holosight robot navigation-assisted percutaneous cannulated screw fixation in treatment of femoral neck fractures.
Weizhen XU ; Zhenqi DING ; Hui LIU ; Jinhui ZHANG ; Yuanfei XIONG ; Jin WU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(6):673-679
OBJECTIVE:
To investigate the effectiveness of Holosight robotic navigation-assisted percutaneous cannulated screw fixation for femoral neck fractures.
METHODS:
A retrospective analysis was conducted on 65 patients with femoral neck fractures treated with cannulated screw fixation between January 2022 and February 2024. Among them, 31 patients underwent robotic navigation-assisted screw placement (navigation group), while 34 underwent conventional freehand percutaneous screw fixation (freehand group). Baseline characteristics, including age, gender, fracture side, injury mechanism, Garden classification, Pauwels classification, and time from injury to operation, showed no significant differences between the two groups ( P>0.05). The operation time, intraoperative blood loss, fluoroscopy frequency, fracture healing time, and complications were recorded and compared, and hip function was evaluated by Harris score at last follow-up. Postoperative anteroposterior and lateral hip X-ray films were taken to assess screw distribution accuracy, including deviation from the femoral neck axis, inter-screw parallelism, and distance from screws to the femoral neck cortex.
RESULTS:
No significant difference was observed in operation time between the two groups ( P>0.05). However, the navigation group demonstrated superior outcomes in intraoperative blood loss, fluoroscopy frequency, deviation from the femoral neck axis, inter-screw parallelism, and distance from screws to the femoral neck cortex ( P<0.05). No incision infections or deep vein thrombosis occurred. All patients were followed up 12-18 months (mean, 16 months). In the freehand group, 1 case suffered from cannulated screw dislodgement and nonunion secondary to osteonecrosis of femoral head at 1 year after operation, 1 case suffered from screw penetration secondary to osteonecrosis of femoral head at 5 months after operation; and 1 case suffered from nonunion secondary to osteonecrosis of femoral head at 6 months after operation in the navigation group. All the 3 patients underwent internal fixators removal and total hip arthroplasty. There was no significant difference in the incidence of complications between the two groups ( P>0.05). The fracture healing time and hip Harris score at last follow-up in the navigation group were significantly better than those in the freehand group ( P<0.05).
CONCLUSION
Compared to freehand percutaneous screw fixation, Holosight robotic navigation-assisted cannulated screw fixation for femoral neck fractures achieves higher precision, reduced intraoperative radiation exposure, smaller incisions, and superior postoperative hip function recovery.
Humans
;
Femoral Neck Fractures/diagnostic imaging*
;
Bone Screws
;
Fracture Fixation, Internal/instrumentation*
;
Male
;
Female
;
Retrospective Studies
;
Robotic Surgical Procedures/methods*
;
Middle Aged
;
Aged
;
Adult
;
Treatment Outcome
;
Operative Time
;
Fracture Healing
;
Surgery, Computer-Assisted/methods*
;
Fluoroscopy
7.The value of ultrasonography in predicting the outcomes of simple long bone fractures treated by closed intramedullary nail fixation.
Tilak Rommel PINTO ; Chiranjeevi Srinivasa GOWDA ; Anston Vernon BRAGGS ; Kiyana MIRZA ; Aravinda HEGDE K
Chinese Journal of Traumatology 2025;28(3):181-186
PURPOSE:
Ultrasonography has been used increasingly in orthopaedic practice credited to its low cost, easy accessibility, non-invasiveness, reproducibility, and safety from radiation. The purpose of this study was to test the validity and efficacy of ultrasonography as an adjunct in the assessment of fracture healing in long bones treated with intramedullary interlocking devices and its predictive value in determining the need for a secondary surgical procedure.
METHODS:
This was a descriptive longitudinal study of 40 skeletally mature patients from November 2016 to February 2019, who sustained long bone fractures of the tibia or femur treated using intramedullary interlocking nails. Patients with comminuted and segmental fracture patterns were excluded from the study. Each patient was evaluated at 6- and 12-week post-surgery using standard orthogonal radiographs and ultrasonography to assess fracture healing. Patients were then followed up until fracture union. Quantitative data was analyzed using frequency statistics and descriptive data with inferential statistics.
RESULTS:
Ultrasonography predicted 87.5% union and 12.5% delayed or non-union as early as 6 weeks after surgery, while radiographs predicted 22.5% union as late as 3 months of follow-up. The sensitivity and specificity of ultrasonography in assessing fracture healing were 100% and 97.2%, respectively, with a positive predictive value of 80.0%. Vascular resistance index was less than 0.5 in all patients who developed delayed or non-union.
CONCLUSION
Ultrasonography is able to predict fracture outcomes much earlier than standardized radiographs with comparable sensitivity and specificity. Vascular resistance index is an objective parameter in assessing callus quality and predicting fracture outcomes.
Humans
;
Fracture Fixation, Intramedullary/methods*
;
Male
;
Female
;
Ultrasonography/methods*
;
Adult
;
Fracture Healing
;
Tibial Fractures/diagnostic imaging*
;
Middle Aged
;
Femoral Fractures/diagnostic imaging*
;
Longitudinal Studies
;
Bone Nails
;
Young Adult
;
Predictive Value of Tests
;
Aged
;
Treatment Outcome
;
Adolescent
8.Relationship between cortical fragments and avascular necrosis of femoral head in young adult femoral neck fractures based on CT imaging.
Mang-Mang CHEN ; Xiao-Sheng CAI ; Yang-Xun LYU ; Sheng-Lei LIN ; Li-Peng HUANG ; Zhou LIN
China Journal of Orthopaedics and Traumatology 2024;37(11):1096-1100
OBJECTIVE:
To explore the effect of femoral neck cortical fragments and surfacial area on avascular necrosis(AVN) after internal fixation of femoral neck fractures based on CT imaging in young adult.
METHODS:
From January 2011 to January 2021, 218 young and middle-aged patients with femoral neck fractures were reverse triangle fixed with three cannulated lag screws, including 104 males and 114 females;aged 19 to 60 years old with a mean of (48.22±10.58) years old. The preoperative waiting time≤48 h was 155 cases, and the preoperative waiting time> 48 h was 63 cases; 68 cases were comminuted cortex of the femoral neck, 32 of them with superficial area of the comminuted cortex>25 mm2. All patients were followed up for at least 2 years, the age, gender, injury side, body mass index, injury mechanism, preoperative waiting time, operation time, Garden classification, whether femoral neck cortex fracture and size by CT analysis and complications were analyzed the correlation to the definite occurrence of AVN. The AVN group and the non-AVN group were divided according to the final efficacy results.Univariate analysis yielded significant independent variables, Multiple Logistic regression analysis was further performed to identify the independent risk factors for AVN.
RESULTS:
By univariate analysis, the AVN and non-AVN groups were significant in injury mechanism(χ2=18.552, P=0.000), preoperative waiting time( χ2=2.065, P=0.033), Garden classification (χ2=12.598, P=0.006), comminuted cortex (χ2=16.357, P=0.000), and the superficial area of the comminuted cortex(χ2=23.371, 0.000, P=0.000). Multiple Logistic regression indicated injury mechanism high energy injury[Exp(B)=3.487, 95%CI(1.583, 10.464), P=0.002], comminuted cortex of the femoral neck[Exp(B)=2.494, 95%CI(1.315, 10.861), P=0.002];the superficial area of the comminuted cortex>25 mm2[Exp(B)=22.161, 95%CI(3.922, 1242.828), P=0.001] were independent risk factors for AVN after internal fixation of femoral neck fractures.
CONCLUSION
High energy injury mechanism, with comminuted cortex of the femoral neck and the superficial area of the comminuted cortex> 25 mm2 were independent risk factors for AVN.The larger the superficial area of the cortex fragment may suggest more complicated injury mechanism and worse outcome.
Humans
;
Male
;
Female
;
Adult
;
Femoral Neck Fractures/diagnostic imaging*
;
Tomography, X-Ray Computed
;
Middle Aged
;
Femur Head Necrosis/etiology*
;
Young Adult
;
Fracture Fixation, Internal/methods*
9.Deformity Correction Using the "Sandwich" Technique for a Non-Union Hoffa Fracture.
Wilson Wy THAM ; Yuet Peng KHOR ; Yu Han CHEE
Annals of the Academy of Medicine, Singapore 2019;48(2):63-66
Adult
;
Bone and Bones
;
diagnostic imaging
;
injuries
;
Femoral Fractures
;
surgery
;
therapy
;
Foot Deformities, Acquired
;
diagnosis
;
etiology
;
therapy
;
Fracture Fixation, Intramedullary
;
adverse effects
;
methods
;
Fractures, Ununited
;
diagnostic imaging
;
etiology
;
surgery
;
Humans
;
Intra-Articular Fractures
;
diagnostic imaging
;
surgery
;
Male
;
Radiography
;
methods
;
Reoperation
;
methods
;
Treatment Outcome
10.Clinics in diagnostic imaging (184). Fat embolism syndrome (FES).
Dinesh R SINGH ; Ashish CHAWLA ; Wilfred Cg PEH
Singapore medical journal 2018;59(3):159-162
A 23-year-old Indian man presented with shortness of breath and new-onset confusion along with a rash on his chest on Postoperative Day 2, following internal fixation of his femur fracture. Although computed tomography pulmonary angiography was negative for filling defects in the pulmonary vasculature, it showed mosaic attenuation changes with some interlobular septal thickening. Magnetic resonance imaging of the brain showed patchy signal abnormalities, predominantly in the grey-white matter junction region with extensive susceptibility artefacts, consistent with petechial haemorrhages. The laboratory work-up showed thrombocytopenia and anaemia. A diagnosis of fat embolism syndrome was established, based on the clinical presentation combined with laboratory and imaging findings. The clinical and imaging features of fat embolism syndrome are discussed.
Brain
;
pathology
;
Dyspnea
;
Embolism, Fat
;
diagnostic imaging
;
Femoral Fractures
;
diagnostic imaging
;
Humans
;
Hypoxia
;
India
;
Magnetic Resonance Imaging
;
Male
;
Pulmonary Embolism
;
Thrombocytopenia
;
Tomography, X-Ray Computed
;
Young Adult

Result Analysis
Print
Save
E-mail