1.Comparison of the efficacy of unilateral nailing combined with bone cement reinforcement and bilateral nailing in the treatment of osteoporotic thoracolumbar fractures.
Yu-Liang LOU ; Guo-Ying CHEN ; Can-Feng WANG ; Hui FEI ; Guan-Rong SUN ; Ren-Fu QUAN ; Wei LI ; Feng HONG
China Journal of Orthopaedics and Traumatology 2025;38(2):134-149
OBJECTIVE:
To compare the efficacy of percutaneous pedicle screw combined with unilateral nail placement combined with bone cement strengthening and bilateral nail placement in the treatment of osteoporotic thoracic and lumbar fractures.
METHODS:
A retrospective case-control study was used to analyze the clinical data of 78 patients with osteoporotic thoracic and lumbar fractures admitted from October 2017 to May 2019. According to the surgical method, it was divided into percutaneous pedicle screw combined with unilateral nail placement combined with unilateral bone cement strengthening group(bone cement group) and percutaneous pedicle screw combined with bilateral nail placement(screw group). In the bone cement group, 40 patients included 16 males and 24 females, with a mean age of (62.1±8.1) years old. In the screw group, 38 patients included 18 males and 20 females with a mean age of (65.1±9.3) years old. The operation time, intraoperative blood loss, length of hospital stay and postoperative complications were compared between two groups. The kyphosis Cobb angle, anterior edge height ratio, central height ratio and pain visual analogue score(VAS) were compared.
RESULTS:
All patients were followed up for 25 to 36 months. The operation time (70.1±17.3) min of the cement group was shorter than that of the screw group (78.6±18.2) min(P<0.05). There were no significant differences in intraoperative blood loss and length of hospital stay(P>0.05). The VAS in the cement group 1 year 1.5±0.5 and the latest follow-up 0.5±0.3 after operation were lower than 1 year 1.8±0.3 and the latest follow-up 0.8±0.4 in the screw group(P<0.05). The kyphosis Cobb angle, anterior edge height ratio, central height ratio in bone cement group, 1 year (6.2±1.2)°, (86.6±3.5)%, (91.1±2.5)%, the last follow-up (6.4±0.7)°, (85.5±3.3)%, (90.5±6.3)% were better than that of the screw group 1 year (6.8±1.4)°, (83.1±2.4)%, (89.9±3.4)% and the latest follow-up (7.1±1.1)°, (82.6±4.1)%, (87.6±5.9)%(P<0.05). There were 3 cases of bone cement leakage in the cement group, all of which had no clinical symptoms;and 2 cases of pedicle screws were extracted in the screw group, and the screws were removed at the last follow-up.
CONCLUSION
Percutaneous pedicle screw combined with unilateral nail placement combined with bone cement strengthening and bilateral nail placement in the treatment of osteoporotic thoracic and lumbar compression fractures in the elderly can achieve satisfactory efficacy and effectively relieve the pain of patients, but the former internal fixation system is more stable, and the long-term follow-up can effectively maintain the height of the anterior middle column and the correction of kyphosis deformity, and the incidence of chronic low back pain is lower.
Humans
;
Male
;
Female
;
Aged
;
Bone Cements
;
Middle Aged
;
Thoracic Vertebrae/surgery*
;
Lumbar Vertebrae/surgery*
;
Retrospective Studies
;
Spinal Fractures/surgery*
;
Osteoporotic Fractures/surgery*
;
Case-Control Studies
;
Bone Nails
;
Pedicle Screws
2.Comparison of efficacy of anterolateral tibial plateau fracture line and anterior tibial fenestration for the treatment of anterolateral tibial plateau column fracture combined with posterolateral column collapse.
Cheng-Fei MENG ; Guan-Qing WANG ; Cheng LUO ; Xiu-Hua LIU ; Ze-Xi LING
China Journal of Orthopaedics and Traumatology 2025;38(3):265-272
OBJECTIVE:
To compare clinical effect of anterior tibial plateau fracture line and anterior tibial fenestration reduction in treating anterolateral tibial plateau column fracture combined with posterior lateral column collapse.
METHODS:
Fifty-two patients with Schatzker typeⅡ tibial plateau anterolateral column fracture combined with posterolateral column collapse admitted from January 2016 to December 2021 were retrospectively analyzed and divided into two groups according to fracture reduction methods. There were 27 patients in fracture line group, including 19 males and 8 females, aged from 26 to 62 years old with an average of (43.2±11.4) years old;the time from injury to operation ranged from 4 to 8 days with an average of (5.8±1.5) days;treated with reduction and internal fixation via fracture line of lateral platform front. There were 25 patients in fenestrate group, including 13 males and 12 females, aged from 22 to 69 years old with an average of (40.8±11.1) years old;the time from injury to operation ranged from 4 to 8 days with an average of (6.0±1.4) days;treated with tibial fenestration reduction and internal fixation. The amount of bone graft, operation time, fracture healing time and complications were compared between two groups. Posterior slope angle (PSA) and posterior slope angle of the lateral tibial plateau was compared before surgery, 2 days and 6 months after surgery. The knee function was evaluated by Hospital for Speical Surgery (HSS) at 2 days and 6 months after surgery, respectively. Fracture reduction was evaluated by Rasmussen anatomic score of knee joint.
RESULTS:
Both of group were followed up from 12 to 24 months (16.0±3.4) months. No redisplacement of fracture, internal and external inversion deformity of knee joint, or instability of knee joint were found between two groups during follow-up. In fracture line group, 1 patient occurred wound fat liquefaction and 2 patients occurred lower limb intermuscular venous thrombosis occurred. In fenestration group, 1 patient occurred joint stiffness, 1 patient occurred lower limb intermuscular venous thrombosis, and 1 patient occurred superficial wound infection;there were no significant difference in complications between two groups (P>0.05). Bone graft volume, operative time and fracture healing time in fracture line group were (3.6±2.3) cm3, (123.4±18.2) min and (13.8±1.8) weeks, while in feneplast group were (4.8±1.8) cm3, (135.5±22.5) min and (15.2±2.0) weeks, respectively;the difference between two groups was statistically significant (P<0.05). The collapse depth of lateral platform articular surface at 2 days and 6 months after surgery were (0.8±0.1) and (0.9±0.1) mm in fracture line group, which were lower than those in fenestration group (0.9±0.1) and (1.1±0.1) mm, respectively (P<0.05). After 2 days and 6 months, , PSA in fracture line group were (9.4±1.5) ° and (10.1±1.9) °, respectively, which were lower than those in fenestration group (10.5±1.5) ° and (11.3±1.9) ° (P<0.05). Rasmussen anatomical scores in fracture line group at 2 days and 6 months were 16(16, 18) and 16(14, 16) points, respectively, which were better than those in fenestrated group (16, 16) and 14(14, 16) points (P< 0.05). The collapse depth, PSA and Rasmussen anatomical score between two groups were better than those before surgery (P<0.05). There was no significant difference in HSS score between two groups at 2 days after surgery (P>0.05). At six months after surgery, HSS score in fracture line group (86.7±3.6) was higher than that in fenestration group (84.1±3.91) (P<0.05). HSS score at 6 months after surgery was better than that at 2 days after surgery (P<0.05).
CONCLUSION
Both anterior tibial plateau fracture line and anterior tibial fenestration could be used to treat anterolateral tibial plateau column fracture with posterior lateral column collapse. Compared with fenestration group, transfracture line group had advantages of less intraoperative bone grafting, shorter operative time, shorter fracture healing time, better articular surface reduction effect and better knee functional recovery.
Humans
;
Male
;
Female
;
Middle Aged
;
Tibial Fractures/physiopathology*
;
Adult
;
Fracture Fixation, Internal/methods*
;
Aged
;
Retrospective Studies
;
Tibia/injuries*
;
Tibial Plateau Fractures
3.Prognostic value of quantitative flow ratio measured immediately after percutaneous coronary intervention for chronic total occlusion.
Zheng QIAO ; Zhang-Yu LIN ; Qian-Qian LIU ; Rui ZHANG ; Chang-Dong GUAN ; Sheng YUAN ; Tong-Qiang ZOU ; Xiao-Hui BIAN ; Li-Hua XIE ; Cheng-Gang ZHU ; Hao-Yu WANG ; Guo-Feng GAO ; Ke-Fei DOU
Journal of Geriatric Cardiology 2025;22(4):433-442
BACKGROUND:
The clinical impact of post-percutaneous coronary intervention (PCI) quantitative flow ratio (QFR) in patients treated with PCI for chronic total occlusion (CTO) was still undetermined.
METHODS:
All CTO vessels treated with successful anatomical PCI in patients from PANDA III trial were retrospectively measured for post-PCI QFR. The primary outcome was 2-year vessel-oriented composite endpoints (VOCEs, composite of target vessel-related cardiac death, target vessel-related myocardial infarction, and ischemia-driven target vessel revascularization). Receiver operator characteristic curve analysis was conducted to identify optimal cutoff value of post-PCI QFR for predicting the 2-year VOCEs, and all vessels were stratified by this optimal cutoff value. Cox proportional hazards models were employed to calculate the hazard ratio (HR) with 95% CI.
RESULTS:
Among 428 CTO vessels treated with PCI, 353 vessels (82.5%) were analyzable for post-PCI QFR. 31 VOCEs (8.7%) occurred at 2 years. Mean value of post-PCI QFR was 0.92 ± 0.13. Receiver operator characteristic curve analysis shown the optimal cutoff value of post-PCI QFR for predicting 2-year VOCEs was 0.91. The incidence of 2-year VOCEs in the vessel with post-PCI QFR < 0.91 (n = 91) was significantly higher compared with the vessels with post-PCI QFR ≥ 0.91 (n = 262) (22.0% vs. 4.2%, HR = 4.98, 95% CI: 2.32-10.70).
CONCLUSIONS
Higher post-PCI QFR values were associated with improved prognosis in the PCI practice for coronary CTO. Achieving functionally optimal PCI results (post-PCI QFR value ≥ 0.91) tends to get better prognosis for patients with CTO lesions.
4.Establishment and application of ultra-fast real-time PCR for Brucella detection
Zhen-na XU ; Zhi-peng WU ; Wei-bin HONG ; Zhi-shen GUAN ; Qi-ming LIN ; Zuan-lan MO ; Yi-fei YE ; Hai-yan XIE ; Min LI ; Yan-qiu ZHU ; Xiao-jun LI ; Xian-peng ZHANG
Chinese Journal of Zoonoses 2025;41(3):278-283
This study was aimed at establishing a method of ultra-fast quantitative PCR for Brucella detection.We used an exogenous recombinant plasmid as the internal reference and targeted the T4SS secretion system,an important Brucella viru-lence factor,to design specific primers and probes.The sensitivity,specificity,and repeatability of this method were evaluated,and a standard curve was constructed.The coincidence rate of detection findings with this method versus quantitative PCR was determined.This method markedly decreased the detection time to only 10 minutes.The standard curve demonstrated a good linear relationship(Y=-3.410 7x+38.357,R2=0.998 5)with a low minimum detection limit of 10 copies/μL.The method exhibited good specificity and did not specifically amplify several common clinical bacteria other than Brucella.The de-tection of three concentrations of positive plasmids yielded coefficients of variation(CVs)of 0.20%to 0.91%,thus demonstra-ting the method's excellent repeatability.Furthermore,140 clinical samples were analyzed concurrently with the fluorescence PCR method,which yielded a 100%compliance rate and consistent results.Our findings indicated that the Brucella ultra-fast quantitative PCR was ultrafast;had high sensitivity,high specificity,and good specificity;and can be used for the clinical de-tection of Brucella and emergency investigation of epidemics.Therefore,this method is valuable for the early diagnosis of Bru-cella.
5.Guideline for the diagnosis and treatment of vertebral refracture after percutaneous vertebral augmentation in elderly patients with osteoporotic thoracolumbar compression fractures (version 2025)
Yong YANG ; Xiaoguang ZHOU ; Qixin CHEN ; Jian CHEN ; Jian DONG ; Liangjie DU ; Shunwu FAN ; Jin FAN ; Zhong FANG ; Haoyu FENG ; Shiqing FENG ; Haishan GUAN ; Aiguo GAO ; Yanzheng GAO ; Yong HAI ; Da HE ; Dengwei HE ; Haiyi HE ; Dianming JIANG ; Xuewen KANG ; Bin LIN ; Baoge LIU ; Changqing LI ; Fang LI ; Li LI ; Fangcai LI ; Weishi LI ; Xiaoguang LIU ; Hongjian LIU ; Xinyu LIU ; Yong LIU ; Zhongjun LIU ; Shibao LU ; Xuhua LU ; Fei LUO ; Yuhai MA ; Keya MAO ; Xuexiao MA ; Bin MENG ; Xu NING ; Limin RONG ; Hongxun SANG ; Jun SHU ; Tiansheng SUN ; Dasheng TIAN ; Zheng WANG ; Bing WANG ; Linfeng WANG ; Qingde WANG ; Qinghe WANG ; Lan WEI ; Jigong WU ; Baoshan XU ; Youjia XU ; Guoyong YIN ; Jinglong YAN ; Feng YAN ; Cao YANG ; Huilin YANG ; Qiang YANG ; Bin ZHAO ; Jie ZHAO ; Yue ZHU ; Jianguo ZHANG ; Wenzhi ZHANG ; Zhongmin ZHANG ; Zhaomin ZHENG ; Yan ZENG ; Baorong HE ; Wei MEI
Chinese Journal of Trauma 2025;41(7):613-626
Vertebral refracture following percutaneous vertebral augmentation (PVA) is commonly seen in elderly patients with osteoporotic thoracolumbar compression fractures (OTLCF). It can lead to recurrent pain, loss of vertebral height, progression of kyphosis, and even neurological dysfunction, significantly impairing patients′ quality of life. Current diagnosis and treatment face multiple challenges, including high misdiagnosis rate, difficulty in choosing between surgical and non-surgical treatment options, lack of standardized surgical protocols, interference from intralesional bone cement during procedures, inadequate stability of internal fixation in osteoporotic bone, and suboptimal compliance of anti-osteoporotic therapy. Establishing a standardized diagnostic and therapeutic framework is urgently needed. To standardize the management process and improve outcomes for vertebral refractures after PVA in elderly OTLCF patients, Spinal Trauma Group of the Orthopedic Branch of Chinese Medical Doctor Association organized experts in the field to develop Guideline for the diagnosis and treatment of vertebral refracture after percutaneous vertebral augmentation in elderly patients with osteoporotic thoracolumbar compression fractures ( version 2025), based on current literature and clinical experience, and adhering to principles of scientific rigor and clinical applicability. A total of 11 recommendations were proposed, encompassing diagnosis, treatment, and rehabilitation of vertebral refracture after PVA in elderly patients with OTLCF, aiming to provide a foundation for a standardized management.
6.Requirements and Technical Aspects of Real world Data Governance in China's Medical Standards and Specifications
Xinmiao GUAN ; Yanzi ZHU ; Hao LIU ; Minjing LUO ; Changhao LIANG ; Feng CAO ; Zhihan LIU ; Jianguo ZHOU ; Dong ZHANG ; Yutong FEI
Medical Journal of Peking Union Medical College Hospital 2025;16(4):1008-1017
Objective To investigate the governance requirements for real world data(RWD)in China's medical standards and specifications,summarize key technical aspects of data governance,and provide refer-ences for RWD governance-related research.Methods Computerized searches were conducted in CNKI,Wan-fang Data,VIP,and SinoMed,as well as the official websites of 29 national medical societies and the National Standard Information Public Service Platform,covering all records from inception to December 12,2023.A data extraction form was developed,and the included standards and specifications were categorized according to the first six RWD governance processes outlined in the Guidelines for Real World Data Used to Generate Real-World Evidence(Trial)issued by the National Medical Products Administration:data security,data extraction,data cleaning,data transformation,data transmission and storage,and quality control.Relevant content on data governance was systematically summarized and comparatively analyzed.Results A total of 32 standards and specifications were included,comprising 15 foundational medical data standards and 17 data gov-ernance technical specifications.Among these,6 addressed data security,6 covered data extraction,5 focused on data cleaning,5 involved data transformation,6 pertained to data transmission and storage,and 4 discussed quality control.Foundational medical data standards included data description elements,terminology,and format standards,broadly covering essential data elements and meeting basic standardization needs.Data gov-ernance technical specifications primarily provided general guidelines for medical data governance,emphasizing requirements and recommendations.While requirements for data security and extraction were relatively well-de-fined,technical guidance on data transformation and quality control remained limited,and implementation pathways for data cleaning,transmission,and storage were insufficiently detailed.Conclusions As real-world evidence plays an increasingly critical role in healthcare decision-making,China's medical standards and speci-fications have established a preliminary governance framework for RWD.However,technical details and practi-cal implementation of RWD governance still require further refinement.
7.Practical challenges in role transition of medical social workers based on medical humanistic care
Hang LI ; Pengfei GUAN ; Jiahe WANG ; Fei ZHANG
Modern Hospital 2025;25(2):183-186
With the increasing emphasis on patient-centered care and psychosocial support in modern healthcare systems,the role of medical social workers has evolved from auxiliary support to comprehensive participation.They serve as crucial liaisons for the healthcare service,delivering humanistic care for patients.Specially,their service has extended beyond traditional psycho-social counseling and doctor-patient communication to encompass whole-course care,community resource coordination,and pa-tient empowerment across multiple domains.As policies promoting humanistic healthcare and holistic well-being are progressively implemented,the scope of work for medical social workers has deepened and broadened in terms of role positioning and service demands.However,they also encounter significant challenges,including role ambiguity,interprofessional collaboration barriers,and insufficient institutional support mechanisms.To address these challenges,enhanced interprofessional education,evidence-based practice implementation,and policy-driven mechanisms are essential for strengthening their clinical competencies,delinea-ting professional boundaries,and optimizing resource allocation.These synergistic approaches collectively reinforce medical social workers'integral role in advancing humanistic care models while elevating their professional stature within the evolving healthcare ecosystem.
8.Changes in the body shape and ergonomic compatibility for functional dimensions of desks and chairs for students in Harbin during 2010-2024
Chinese Journal of School Health 2025;46(3):315-320
Objective:
To analyze the change trends in the body shape indicators and proportions of students in Harbin from 2010 to 2024, and to investigate ergonomic compatibility of functional dimensions of school desks and chairs with current student shape indicators, so as to provide a reference for revising furniture standards of desks and chairs.
Methods:
Between September and November of both 2010 and 2024, a combination of convenience sampling and stratified cluster random sampling was conducted across three districts in Harbin, yielding samples of 6 590 and 6 252 students, respectively. Anthropometric shape indicators cluding height, sitting height, crus length, and thigh length-and their proportional changes were compared over the 15-year period. The 2024 data were compared with current standard functional dimensions of school furniture. The statistical analysis incorporated t-test and Mann-Whitney U- test.
Results:
From 2010 to 2024, average height increased by 1.8 cm for boys and 1.5 cm for girls; sitting height increased by 1.5 cm for both genders; crus length increased by 0.3 cm for boys and 0.4 cm for girls; and thigh length increased by 0.5 cm for both genders. The ratios of sitting height to height, and sitting height to leg length increased by less than 0.1 . The difference between desk chair height and 1/3 sitting height ranged from 0.4-0.8 cm. Among students matched with size 0 desks and chairs, 22.0% had a desk to chair height difference less than 0, indicating that the desk to chair height difference might be insufficient for taller students. The differences between seat height and fibular height ranged from -1.4 to 1.1 cm; and the differences between seat depth and buttock popliteal length ranged from -9.8 to 3.4 cm. Among obese students, the differences between seat width and 1/2 hip circumference ranged from -20.5 to -8.7 cm, while it ranged from -12.2 to -3.8 cm among non obese students.
Conclusion
Current furniture standards basically satisfy hygienic requirements; however, in the case of exceptionally tall and obese students, ergonomic accommodations such as adaptive seating allocation or personalized adjustments are recommended to meet hygienic requirements.
9.The first human case of Clinostomum complanatum infection in China
FANG Zhengming ; LEI Jiahui ; GUAN Fei
China Tropical Medicine 2025;25(1):124-
A 32-year-old female patient experienced a foreign body sensation in her esophagus on the evening of September 22, 2024, after consuming undercooked grass carp at a restaurant in Wuhan. Esophagoscopy conducted at the hospital revealed no abnormalities. Three days later, she had a stabbing pain in the pharynx. On October 8, upon self-examination, she noticed a red brown worm exhibiting stretching and contracting movements attached near the uvula in her pharynx and then went to the hospital. During the removal of the worm, the doctor observed the ulcers on the mucous membrane. Serological antibody tests for seven common human parasitic worms, including Schistosoma japonicum, Paragonimus westermani, Clonorchis sinensis, cysticercus of Taenia solium, sparganum, hydatid cyst, and Trichinella spiralis, were all negative. The isolated worm was reddish brown, measuring 4 mm in length and 2 mm in width. Staining with hydrochloric carmine dye revealed a morphology consistent with Clinostomum complanatum (Rud., 1819), characterized by an oral sucker at the anterior end, a pharynx connecting to intestinal branches, and two intestinal branches extending to the posterior end of the body with small sub-branches. The ventral sucker, larger than the oral sucker, was located at the front 1/4 of the body. A pair of testes were arranged longitudinally in the mid-posterior part, with an ovary located between the two testes and a uterus located above the upper testis. A comprehensive search of 188 databases comprising more than 460 million full-text articles through the library of Huazhong University of Science and Technology confirmed the first reported case of Clinostomum complanatum infection in humans in China.
10.The historical evolution of Chinese physiology textbooks.
Yan FENG ; Xiao ZHAI ; Xin WANG ; Feng YANG ; Liang ZHU ; Guo-Chao SUN ; Ning WANG ; Jun ZHANG ; Jing XIAO ; Wei-Wei LIU ; You-Fei GUAN
Acta Physiologica Sinica 2025;77(1):1-12
This article systematically reviews the characteristics and trends of the writing, editing, publication and promotion of physiology textbooks in China from the late 19th century to the present, focusing on the introduction, development and innovation of Chinese physiology textbooks. The development of physiology textbooks in China is divided into four main stages: the introduction and initial development of physiology textbooks from the late 19th century to 1925; the localization and diversification of textbooks from 1926 to 1949, after the establishment of the Chinese Physiological Society; the exploratory phase of textbook construction after the founding of the People's Republic of China from 1949 to 1976; the formation and innovation of the textbook development process from 1977 to the present, following the restoration of the college entrance examination. For each phase, the article not only records the historical development of physiology textbooks, but also analyzes the evolution of their content, writing styles and the interaction with the social and political contexts. The article summarizes the characteristics and experiences of all these four phases. Special attention is given to the comprehensive statistical analysis of physiology textbooks published since the restoration of the college entrance examination and Economic Reform and Opening-up in 1977, revealing the changes in the number, publication trends and academic features of textbooks during this period. Finally, the article presets the future development of physiology textbooks in China, proposing that textbook writing should integrate aspects such as ideological and political education, medical humanities, basic and clinical medicine, health education, scientific research and international exchange and collaboration. The article also advocates for the application of new technologies and methods, such as artificial intelligence, virtual teaching models and knowledge graphs, to support "personalized learning". This research provides a systematic reference for the study of the history of medical education and offers theoretical support for the future innovation of physiology textbook in China.
Humans
;
China
;
History, 19th Century
;
History, 20th Century
;
History, 21st Century
;
Physiology/education*
;
Textbooks as Topic/history*


Result Analysis
Print
Save
E-mail