1.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
2.Research progress of unruptured intracranial aneurysm combined with intracranial or extracranial artery stenosis
Weikai WANG ; Yonggang MA ; Weibo LYU ; Peng SHI ; Guangliang FAN ; Mingfei YANG ; Chao WANG
Chinese Journal of Cerebrovascular Diseases 2025;22(2):120-126,134
Intracranial or extracranial artery stenosis is the major reason of ischemic stroke,which leads to insufficient cerebral blood flow perfusion and triggers cerebral dysfunction.The detection rate of unruptured intracranial aneurysm(UIA)combined with intracranial or extracranial artery stenosis is increasing with advances in diagnostic techniques for cerebrovascular disease.Due to the complexity of location and hemodynamic implications,there is no consensus on the treatment of UIA combined with intracranial or extracranial artery stenosis.This article summarized several types of UIA combined with intracranial or extracranial artery stenosis in terms of anatomical location,hemodynamics,and therapy strategies,aiming to provide references for clinical interventionalists.
3.Role of cumulative hemoglobin A 1c levels and insulin doses in insulin resistance-related metabolic disorders in patients with type 1 diabetes
Mei SHI ; Yan ZHANG ; Wenqi FAN ; Yan CHEN ; Yuting XIE ; Chao DENG ; Xia LI
Chinese Journal of Internal Medicine 2025;64(4):309-317
Objective:To examine the effect of cumulative hemoglobin A 1c (HbA 1c) levels and insulin dosage on insulin resistance (IR)-related metabolic disturbances in newly diagnosed patients with type 1 diabetes (T1D). Methods:This retrospective cohort study included T1D patients admitted to the Second Xiangya Hospital of Central South University from November 2015 to March 2023. Clinical data collected comprised age, sex, disease duration, insulin dosage, body mass index, waist circumference, blood pressure, HbA 1c levels, islet autoantibodies, and fasting blood lipid profiles. IR-related metabolic disturbances assessed were overweight, obesity, central obesity, hypertension, and dyslipidemia. Cox regression and cluster analyses were applied to assess the influence of cumulative HbA 1c and insulin dosage on these metabolic disturbances. Results:A total of 235 patients were included, with 97 males (41.3%) and 138 females (58.7%). The median age was 19.8 (13.3, 31.1) years, and the median follow-up duration was 30.8 (20.8, 45.6) months. During follow-up, 41.6% (72/173) of patients developed IR-related metabolic disturbances. Multivariate Cox regression analysis revealed that a cumulative HbA 1c ≥60 mmol/mol was an independent risk factor for any IR-related metabolic disturbance [ HR (95% CI): 1.739 (1.067-2.835) ] and for triglyceride abnormalities [ HR (95% CI): 3.277 (1.176-9.127)]. Additionally, a cumulative insulin dosage ≥0.5 U·kg -1·d -1 was identified as an independent risk factor for overweight, obesity, or central obesity [ HR (95% CI): 2.374 (1.059-5.323)]. Cluster analysis further identified that patients with higher levels of cumulative HbA 1c and insulin dosage, particularly those with adolescent-onset diabetes, had the highest likelihood of developing hypertension ( HR=2.460, 95% CI 1.008-6.005), overweight/obesity/central obesity ( HR=2.707, 95% CI 1.062-6.900), triglyceride abnormalities ( HR=5.495, 95% CI 1.842-16.391), high-density lipoprotein cholesterol abnormalities ( HR=11.054, 95% CI 4.107-29.751), and any IR-related metabolic disturbance ( HR=5.833, 95% CI 2.602-13.077). Conclusions:Elevated cumulative HbA 1c and insulin dosage levels in T1D patients are associated with an increased risk of developing IR-related metabolic disturbances. These findings underscore the urgent need for novel therapeutic strategies tailored to this population.
4.Multimodal ultrasound of the testis in differentiating subtypes of spermatogenic dysfunction:a preliminary study
Tingting LEI ; Gaoxiang FAN ; Penglin ZOU ; Chao JIA ; Hongmei LIANG ; Jun LIN ; Rong WU ; Lianfang DU ; Zheng LI ; Qiusheng SHI
Chinese Journal of Ultrasonography 2025;34(8):678-685
Objective:To analyze the imaging features of testicular conventional ultrasonography(US),shear wave elastography(SWE),and contrast-enhanced ultrasonography(CEUS)in subtypes of spermatogenic dysfunction(focal,arrest,and exhausted),and to evaluate the diagnostic efficacy of testicular multimodal ultrasound.Methods:A prospective study enrolled 310 spermatogenic dysfunction patients(focal type group: n=77,arrest type group: n=20,exhaustive type group: n=213)and 30 healthy volunteers(control group)at Shanghai General Hospital between October 2023 and December 2024. All patients underwent preoperative testicular US,SWE,and CEUS examinations,followed by microdissection testicular sperm extraction. Ultrasound parameters were compared among groups,and receiver operating characteristic(ROC)curves were plotted to assess the diagnostic efficacy of multimodal ultrasound for different subtypes. Results:①Testicular volume:The arrest group exhibited significantly greater volume compared to the focal group and the exhausted group(all P<0.05). No statistically significant difference was observed between the arrest group and the normal group( P>0.05). ②Mean Young's modulus(Emean):The arrest group exhibited significantly lower Emean compared with both the focal and exhausted groups(all P<0.05),but showed no significant difference versus the normal group( P>0.05). ③CEUS quantitative parameters:The arrival time(AT)and time to peak(TTP)in the exhausted group were higher than those in the normal group,while the peak intensity(PI)and area under the time-intensity curve(AUC)were lower(all P<0.05). No significant differences were found in AT,TTP,or AUC among the three spermatogenic dysfunction subgroups(all P>0.05). ④CEUS perfusion patterns:The focal group predominantly exhibited a mottled pattern(70.13%,54/77). Both the arrest group(90.00%,18/20)and the normal group(93.33%,28/30)predominantly exhibited an rich pattern. The exhausted group predominantly exhibited a sparse pattern(56.34%,120/213). ⑤ROC curve analysis showed that for differentiating the arrest group from the focal type group and the exhaustive type group,the combination of Emean,testicular volume,and CEUS perfusion pattern yielded an AUC of 0.931,with a sensitivity of 95.00% and specificity of 85.86%. For differentiating the focal type group from the exhaustive type group,the combination of testicular echogenicity,CEUS perfusion pattern,and Emean yielded an AUC of 0.833,with a sensitivity of 81.82% and specificity of 75.12%. Conclusions:Multimodal ultrasonography can comprehensively characterize the imaging features of different subtypes of spermatogenic dysfunction,holding promise as a noninvasive predictive tool.
5.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
6.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
7.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
8.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
9.Efficacy and safety of intrasaccular flow disruptor in wide-necked intracranial aneurysms: a multicenter retrospective study
Xiaowen ZHANG ; Jing LI ; Xifeng LI ; Chuanzhi DUAN ; Aihua LIU ; Huaizhang SHI ; Haowen XU ; Nan MA ; Zhiqiang YAO ; Feng FAN ; Chao LIU ; Jinyi LI ; Hailong ZHONG ; Mengyan FAN ; Jiaxin WAN ; Rijin LIN ; Huixiang LIU ; Jiamei ZHANG ; Xin ZHANG ; Sheng GUAN
Chinese Journal of Neuromedicine 2025;24(1):16-22
Objective:To evaluate the efficacy and safety of intrasaccular flow disruptor in wide-necked intracranial aneurysms.Methods:One hundred and seventeen patients with wide-necked intracranial aneurysms treated with intrasaccular flow disruptor were collected from Department of Neurointervention (First Affiliated Hospital of Zhengzhou University), Department of Neurosurgery (Beijing Tiantan Hospital, Capital Medical University), Department of Cerebrovascular Surgery, Neurosurgery Center (Zhujiang Hospital, Southern Medical University), and Department of Neurosurgery (First Affiliated Hospital of Harbin Medical University) from August 2022 to March 2024. Raymond-Roy Occlusion Classification (RROC) was employed to evaluate aneurysm embolization immediately after procedure; cranial CT or MRI within 48 hours of embolization were performed to identify any new intracranial hemorrhage, subarachnoid hemorrhage, or new symptomatic cerebral infarction related to the intracranial aneurysms. Modified Rankin Scale (mRS) was used to assess the neurological function at discharge. Imaging follow-up and outpatient follow-up were performed at 6 months after embolization to evaluate the aneurysm occlusion degree and complications.Results:A total of 117 intrasaccular flow disruptors were implanted in 117 patients, with a technical success rate of 100%; 115 patients (98.3%) enjoyed successful one-time release of their disruptors, and 2 patients (1.7%) required retrieval and redirection of the disruptors before second successful attempt. Flow disruptor plus stent was performed in 13 patients (11.1%). Immediately after procedure, RROC grading I was noted in 3 patients, grading II in 51 patients and grading III in 63 patients. Cranial CT or MRI within 48 hours of embolization indicated no new intracranial hemorrhage, subarachnoid hemorrhage, or symptomatic cerebral infarction related to the intracranial aneurysms. All patients had mRS score of 0 at discharge. Eighty-three patients completed a 6-month follow-up (RROC grading I in 41 patients, grading II in 33 patients and grading III in 9 patients), without ischemic or hemorrhagic adverse events.Conclusion:The results of this study preliminarily suggest that intrasaccular flow disruptor is effective and safe in wide-necked intracranial aneurysms.
10.Neuroform Atlas stent-assisted coil embolization for middle cerebral artery bifurcation aneurysms: a multicenter retrospective study
Mengyan FAN ; Jing LI ; Chuanzhi DUAN ; Huaizhang SHI ; Aihua LIU ; Xiaochuan SUN ; Feng FAN ; Jinyi LI ; Chao LIU ; Haowen XU ; Linyu WANG ; Zhiqiang YAO ; Hailong ZHONG ; Xiaowen ZHANG ; Rijin LIN ; Jiaxin WAN ; Nan ZHANG ; Huixiang LIU ; Jiamei ZHANG ; Sheng GUAN
Chinese Journal of Neuromedicine 2025;24(2):141-146
Objective:To evaluate the efficacy and safety of Neuroform Atlas stent-assisted coil embolization in patients with middle cerebral artery bifurcation aneurysms.Methods:A retrospective analysis was performed; the clinical data of 46 patients with middle cerebral artery bifurcation aneurysms accepted Neuroform Atlas stent-assisted coil embolization in First Affiliated Hospital of Zhengzhou University, Beijing Tiantan Hospital Affiliated to Capital Medical University, First Affiliated Hospital of Harbin Medical University, Zhujiang Hospital of Southern Medical University and First Affiliated Hospital of Chongqing Medical University from January 2022 to March 2024 were collected. There were 28 ruptured aneurysms (60.87%) and 18 unruptured aneurysms (39.13%). Follow-up was performed for more than 3 months; Raymond-Roy grading was used to evaluate the aneurysm embolization immediately after embolization and during follow-up; perioperative hemorrhagic or ischemic complications were recorded; modified Rankin Scale (mRS) was used to evaluate the prognosis of the patients at discharge and during follow-up (mRS score≤2: good prognosis, and mRS score>2: poor prognosis).Results:Coil embolization was successful in all 46 patients. DSA immediately after embolization showed that 41 patients (89.13%) had completely occluded aneurysms (Raymond-Roy grading I), 2 patients (4.35%) had residual aneurysm neck (Raymond-Roy grading Ⅱ) and 3 patients (6.52%) had partially occluded aneurysms (Raymond-Roy grading Ⅲ). Perioperative complications occurred in 5 patients, including 2 with postoperative cerebral infarction, 1 with hydrocephalus, 1 with postoperative pneumonia leading to respiratory failure, and 1 with stent thrombosis during embolization. Both at discharge and 3 months after embolization, 43 patients (93.48%) had good prognosis and 3 patients (6.52%) had poor prognosis. No obvious ischemic complications (such as stent restenosis) or hemorrhagic complications (such as re-rupture of the aneurysms) were found in all patients. Thirty patients (65.22%) had imaging follow-up for 6-12 months: 26 (86.67%) had Raymond-Roy grading I, 3 (10.00%) had Raymond-Roy grading II, and 1 (3.33%) had Raymond-Roy grading III.Conclusion:Neuroform Atlas stent-assisted coil embolization has good short-term efficacy and high safety in middle cerebral artery bifurcation aneurysms, but long-term follow-up observation is still needed to verify its efficacy.

Result Analysis
Print
Save
E-mail