1.Treatment of Chronic Inflammatory Demyelinating Polyneuropathy
Eun Kyoung LEE ; Sooyoung KIM ; Eunhee SOHN
Journal of the Korean Neurological Association 2025;43(2):83-89
Chronic inflammatory demyelinating polyneuropathy (CIDP) is a chronic autoimmune disease of the peripheral nervous system, primarily treated with corticosteroids and intravenous immunoglobulin as first-line therapies. Early treatment yields better outcome before nerve damage caused by the immune response. Once axonal damage has progressed, immunotherapy becomes ineffective, making early intervention crucial. Additionally, as treatment responses vary among patients, it is essential to assess treatment efficacy objectively and tailor therapy accordingly. Since there are currently no biomarkers that accurately reflect disease status, regular physical examinations are necessary to evaluate treatment effectiveness and adjust maintenance therapy. This review outlines the current clinical guidelines for the treatment of CIDP and explores emerging therapeutic options, including neonatal Fc receptor inhibitors and complement pathway inhibitors.
2.Study on the Necessity and Methodology for Enhancing Outpatient and Clinical Education in the Department of Radiology
Soo Buem CHO ; Jiwoon SEO ; Young Hwan KIM ; You Me KIM ; Dong Gyu NA ; Jieun ROH ; Kyung-Hyun DO ; Jung Hwan BAEK ; Hye Shin AHN ; Min Woo LEE ; Seunghyun LEE ; Seung Eun JUNG ; Woo Kyoung JEONG ; Hye Doo JEONG ; Bum Sang CHO ; Hwan Jun JAE ; Seon Hyeong CHOI ; Saebeom HUR ; Su Jin HONG ; Sung Il HWANG ; Auh Whan PARK ; Ji-hoon KIM
Journal of the Korean Society of Radiology 2025;86(1):199-200
3.Treatment of Chronic Inflammatory Demyelinating Polyneuropathy
Eun Kyoung LEE ; Sooyoung KIM ; Eunhee SOHN
Journal of the Korean Neurological Association 2025;43(2):83-89
Chronic inflammatory demyelinating polyneuropathy (CIDP) is a chronic autoimmune disease of the peripheral nervous system, primarily treated with corticosteroids and intravenous immunoglobulin as first-line therapies. Early treatment yields better outcome before nerve damage caused by the immune response. Once axonal damage has progressed, immunotherapy becomes ineffective, making early intervention crucial. Additionally, as treatment responses vary among patients, it is essential to assess treatment efficacy objectively and tailor therapy accordingly. Since there are currently no biomarkers that accurately reflect disease status, regular physical examinations are necessary to evaluate treatment effectiveness and adjust maintenance therapy. This review outlines the current clinical guidelines for the treatment of CIDP and explores emerging therapeutic options, including neonatal Fc receptor inhibitors and complement pathway inhibitors.
4.Study on the Necessity and Methodology for Enhancing Outpatient and Clinical Education in the Department of Radiology
Soo Buem CHO ; Jiwoon SEO ; Young Hwan KIM ; You Me KIM ; Dong Gyu NA ; Jieun ROH ; Kyung-Hyun DO ; Jung Hwan BAEK ; Hye Shin AHN ; Min Woo LEE ; Seunghyun LEE ; Seung Eun JUNG ; Woo Kyoung JEONG ; Hye Doo JEONG ; Bum Sang CHO ; Hwan Jun JAE ; Seon Hyeong CHOI ; Saebeom HUR ; Su Jin HONG ; Sung Il HWANG ; Auh Whan PARK ; Ji-hoon KIM
Journal of the Korean Society of Radiology 2025;86(1):199-200
5.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
6.Erratum: Correction of Text in the Article “The Long-term Outcomes and Risk Factors of Complications After Fontan Surgery: From the Korean Fontan Registry (KFR)”
Sang-Yun LEE ; Soo-Jin KIM ; Chang-Ha LEE ; Chun Soo PARK ; Eun Seok CHOI ; Hoon KO ; Hyo Soon AN ; I Seok KANG ; Ja Kyoung YOON ; Jae Suk BAEK ; Jae Young LEE ; Jinyoung SONG ; Joowon LEE ; June HUH ; Kyung-Jin AHN ; Se Yong JUNG ; Seul Gi CHA ; Yeo Hyang KIM ; Youngseok LEE ; Sanghoon CHO
Korean Circulation Journal 2025;55(3):256-257
7.Impact of adding preoperative magnetic resonance imaging to ultrasonography on male breast cancer survival: a matched analysis with female breast cancer
Jeongmin LEE ; Ka Eun KIM ; Myoung Kyoung KIM ; Haejung KIM ; Eun Sook KO ; Eun Young KO ; Boo-Kyung HAN ; Ji Soo CHOI
Ultrasonography 2025;44(1):72-82
Purpose:
The study investigated whether incorporating magnetic resonance imaging (MRI) alongside ultrasonography (US) in the preoperative evaluation is associated with differing survival outcomes between male and female breast cancer patients in a matched analysis. Additionally, clinicopathological prognostic factors were analyzed.
Methods:
Between January 2005 and December 2020, 93 male and 28,191 female patients who underwent breast surgery were screened. Exact matching analysis was conducted for age, pathologic T and N stages, and molecular subtypes. The clinicopathological characteristics and preoperative imaging methods of the matched cohorts were reviewed. Disease-free survival (DFS) and overall survival (OS) were assessed using Kaplan-Meier analysis, and Cox proportional hazards regression analysis was used to identify prognostic factors.
Results:
A total of 328 breast cancer patients (61 men and 267 women) were included in the matched analysis. Male patients had worse DFS (10-year DFS, 70.6% vs. 89.2%; P=0.001) and OS (10-year OS, 64.4% vs. 96.3%; P<0.001) than female patients. The pathologic index cancer size (hazard ratio [HR], 2.013; 95% confidence interval [CI], 1.063 to 3.810; P=0.032) was associated with worse DFS, whereas there were no significant factors associated with OS. Adding MRI to US for preoperative evaluation was not associated with DFS (HR, 1.117; 95% CI, 0.223 to 5.583; P=0.893) or OS (HR, 1.529; 95% CI, 0.300 to 7.781; P=0.609) in male patients.
Conclusion
Adding breast MRI to US in the preoperative evaluation was not associated with survival outcomes in male breast cancer patients, and the pathologic index cancer size was associated with worse DFS.
8.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
9.Erratum: Correction of Text in the Article “The Long-term Outcomes and Risk Factors of Complications After Fontan Surgery: From the Korean Fontan Registry (KFR)”
Sang-Yun LEE ; Soo-Jin KIM ; Chang-Ha LEE ; Chun Soo PARK ; Eun Seok CHOI ; Hoon KO ; Hyo Soon AN ; I Seok KANG ; Ja Kyoung YOON ; Jae Suk BAEK ; Jae Young LEE ; Jinyoung SONG ; Joowon LEE ; June HUH ; Kyung-Jin AHN ; Se Yong JUNG ; Seul Gi CHA ; Yeo Hyang KIM ; Youngseok LEE ; Sanghoon CHO
Korean Circulation Journal 2025;55(3):256-257

Result Analysis
Print
Save
E-mail